Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-940/940F. Picture:

Similar documents
Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-68/68A/118/118A. Picture:

Service Manual. FILE No.HMRSM

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

DOUBLE DOOR FREEZER.

Deep Freezer-upright

REFRIGERATOR M E D I C A L.

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator

-86 Ultra Low Temperature Freezer

Biomedical Freezer 37 38

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Mega Top Sandwich Prep Table Manual

Combined Refrigerator and Freezer Operation Manual

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Upright Chromatography Refrigerators

4 Blood Bank Refrigerator

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Refrigerators. Upright Blood Bank. i.series Horizon Series

Pharmaceutical Refrigerator Operation Manual Model: HYC-260 HYC-360 HYC-290 HYC-390

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Undercounter Refrigerator Operation Manual

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

TABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1

Platelet bags constant shaking for long periods of time.

Pharmacy Refrigerator

MEDICAL REFRIGERATORS

VWR Laboratory Refrigerators and Freezers

Vaccine & Pharmacy Upright Glass Door Refrigerators

Freezers. Laboratory & Plasma. i.series Horizon Series

REFRIGERATOR P H A R M A C Y.

-1050C FREEZER NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Commodity Description

Laboratory & Pharmacy Refrigerators

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Protect your research

Operation Manual. Pharmaceutical Refrigerator HYC-68/68A

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

HYC-950L. Medical refrigerator M.R.C LTD. OFFICES: HAGAVISH 3, HOLON P.O.B. 111, HOLON 58100, ISRAEL TEL: FAX:

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Laboratory refrigerators and freezers

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

For machines with refrigerant R600a. For machines with refrigerant R134a. Exploded diagram and spare parts list. Click. Click.

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

Multi-Lab REFRIGERATORS Frigidere medicale

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

Service Manual For BAPT1, BAPT2, BAPT3 BAUR1, BAUR2, BAUR3, BAUF1, BAUF2

SERVICE MANUAL. Refrigerator MODEL: HA10TG31SW HA10TG31SB HA10TG31SS WARNING. Haier Group

SERVICE MANUAL REFRIGERATION

Glass Doors, Hinged Bottom Mounts

THERMOELECTRIC WINE COOLER. Operation Manual. Model No: CCVB 25T UK

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

THERMOELECTIRC WINE COOLER

Upright freezer V 60Hz ccl 4. Block condenser Aspera compressor grp. 38. Upright freezer compr. grp 38. Version: Date: Initials: Description:

Product Specifications Sheets

Platelet Storage. i.series Horizon Series

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Service Manual For MCR27S, MCR48S, MCR72S, MCR27U, MCR48U, MCR72U MCF27U, MCF48U, MCF72U. Visit us on the web at

SERVICE MANUAL REFRIGERATION

Platelet Storage. i.series Horizon Series

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Cardinal Health Refrigerators and Freezers. Keeping your samples safe

Slimline. Laboratory refrigerators and freezers

TECHNICAL MANUAL F49-S, F49-SH F72-S, F72-SH R49-S, R49-SH, R49-G R72-S, R72-SH, R72-G - 1 -

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

FN-510DW. FN-651NW same as FN510DW FR-650NT.. FN-650NT.. FR-650NW.. FN-650NW.. FR-651NT.. FN-651NT.. FN-651NW FR-651NW.. FN-510DW

Installation, Operation and Service Manual

Ultra-Low Temperature Chest Freezers

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Advance Blood Storage system from Meditech

Freezer Operation Manual

Reach In Refrigerators Bottom Mount

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Technical Manual Binair Monobloc Heat Pump

SERVICE MANUAL REFRIGERATION

HEAT PUMP WATER HEATER

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

Versatile new products for multiple applications and specialty conditions. New Products Catalog

Portable Air Conditioner USER MANUAL

1.1 Setup Installation

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Laboratory Refrigerator/Deep Freezer TC 802

Biomedical Freezer & Refrigeration Solutions

Keeping your samples safe

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

PORTABLE AIR CONDITIONER MODEL NO: AC7000

Stainless steel refrigerators & freezers

Pharmacy. Refrigerators and Freezers MEET STATE AND FEDERAL GUIDELINES

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

! WARNING CAUTION DANGER WARNING CAUTION

Mobile Type Air Conditioner

Transcription:

Service Manual Pharmacy Refrigerator(2~8 ) Model:HYC-940/940F Picture:

Content 1. Definition of the Model... 3 2. Appearance and Parts... 3 3. Product Technical Parameters... 5 4. Electrical parts and circuit diagram... 8 5. Spare parts of cooling system... 9 6. Spare part list and exploded view... 11 7. Instruction of operation... 15 8. Troubleshooting... 19 2

1. Definition of the Model HYC-940&940F Service Manual H(Haier)Y(Pharmacy)C(Refrigerator)-940(Capacity is 890L) H(Haier)Y(Pharmacy)C(Refrigerator)-940F(capacity is 890L,foaming door) 2. Appearance and Parts HYC-940 3

HYC-940F 4

3. Product Technical Parameters 1.HYC-940(220-240V~/50Hz): Model HYC-940 Type upright glass door air-cooling Climate class N(10 ~32 ) Temp. range 2~8 Capacity (L) 890L Interior 1030x590x1425 Dimensions(W D H) Exterior 1130x755x1980 Dimensions(W D H) Net /Gross weight(kg) 227/279 Exterior/Interior Material SPCC Power Supply 220-240V~/50Hz Rated Power/Current 850W/4.5A Controller Microprocessor Qty of sensor 5pcs Alarm type Buzzer,light,remote Alarm content High& low temp.,sensor error,power failed,low battery, door Ajar Foot and wheel 2 feet & 4 wheels Test hole 1 Shelf Shelves :12pcs Lamp LED(9W) Door and lock Glass door (with heater)+lock Defrosting Auto defrosting+ Forced defrosting (with heater) Tank mouth heater Yes Safety mode Sensor failed SM 5

2.HYC-940(220-240V~/60Hz): Model HYC-940 Type upright glass door air-cooling Climate class N(10 ~32 ) Temp. range 2~8 Capacity (L) 890L Interior 1030x590x1425 Dimensions(W D H) Exterior 1130x755x1980 Dimensions(W D H) Net /Gross weight(kg) 227/279 Exterior/Interior SPCC Material Power Supply 220-240V~/60Hz Rated Power/Current 770W/4.5A Controller Microprocessor Qty of sensor 5pcs Alarm type Buzzer,light,remote Alarm content High& low temp.,sensor error,power failed,low battery, door Ajar Foot and wheel 2 feet & 4 wheels Test hole 1 Shelf Shelves :12pcs Lamp LED(9W) Door and lock Glass door (with heater)+lock Defrosting Auto defrosting+ Forced defrosting (with heater) Tank mouth heater Yes Safety mode Sensor failed SM 3.HYC-940(115V~/60Hz): Model HYC-940 Type upright glass door air-cooling Climate class N(10 ~32 ) Temp. range 2~8 Capacity (L) 890L Interior 1030x590x1425 Dimensions(W D H) Exterior 1130x755x1980 Dimensions(W D H) Net /Gross weight(kg) 227/279 Exterior/Interior SPCC Material Power Supply 115V~/60Hz 6

4.HYC-940F: HYC-940&940F Service Manual Rated Power/Current 850W/11A Controller Microprocessor Qty of sensor 5pcs Alarm type Buzzer,light,remote Alarm content High& low temp.,sensor error,power failed,low battery, door Ajar Foot and wheel 2 feet & 4 wheels Test hole 1 Shelf Shelves :12pcs Lamp LED(9W) Door and lock Glass door (with heater)+lock Defrosting Auto defrosting+ Forced defrosting (with heater) Tank mouth heater Yes Safety mode Sensor failed SM Model HYC-940 Type upright glass door air-cooling Climate class N(10 ~32 ) Temp. range 2~8 Capacity (L) 890L Interior 1030x590x1425 Dimensions(W D H) Exterior 1130x755x1980 Dimensions(W D H) Net /Gross weight(kg) 227/279 Exterior/Interior SPCC Material Power Supply 220-240V~/50Hz Rated Power/Current 600W/3A Controller Microprocessor Qty of sensor 5pcs Alarm type Buzzer,light,remote Alarm content High& low temp.,sensor error,power failed,low battery, door Ajar Foot and wheel 2 feet & 4 wheels Test hole 1 Shelf Shelves :12pcs Lamp LED(9W) Door and lock Foaming Door + LOCk Defrosting Auto defrosting+ Forced defrosting (with heater) Tank mouth heater Yes Safety mode Sensor failed SM 7

4. Electrical parts and circuit diagram No. Part code Name QTY Specification Applicable models 1 0074090955 Display board 1 2 0074091548 Control board 1 940 3 0074091548A Control board 1 940F 4 0074091549 Power board 1 7 0074091430A Battery 1 12V/4AH 9 0074091590 LED light 6 10 0074000186 Transformer for door 2 AC/55V 940(220V) heater 11 0074091342 Transformer for door 2 AC/55V 940(115V) heater 11 0070812074 Glass door(right) 1 AC/55V/115W 940 12 0070812035 Glass door (left) 1 AC/55V/115W 940 13 0074090544 Condenser fan motor 3 EBM/19W 940(220V) 14 0074091557 Condenser fan motor 3 ADDA/34W 940(115V) 15 0075030020A Condenser fan motor 2 EBM/30W 940(220V) 16 0074091408 Condenser fan motor 2 EBM/30W 940(115V) 17 0070107553 Condenser fan motor 2 blade(φ200/28 /SUCTION AIR) Circuit diagram with blade(115v) 8

5. Spare parts of cooling system No. Part Code Name QTY Specification Remark 1 0074000248 Compressor 1 EMBR FFI12HBK 940(220-240V~/50Hz) 2 0074000202 Compressor 1 SC12G 940(220-240V~/60Hz) 3 0074091328 Compressor 1 SC12G 940(115V~/60Hz) 4 0270700156 evaporator 1 \ 940(220-240V~/50Hz) 5 0060732673 evaporator 1 \ 940(220-240V~/60Hz) 6 0060732673 evaporator 1 \ 940(115V~/60Hz) 7 0070702086 Condenser 1 \ 8 0070700780 Drier filter 1 9 0073010002A R134a - Qty:R134a 9

蒸发器 Evaporator HYC-940&940F Service Manual Condenser 冷凝器 Drier 干燥过滤器 filter Capillary 毛细管 Suction 回气管 tube Exhaust 排气管 tube Compressor 压缩机 Oil for compressor 压机油 10

6. Spare part list and exploded view HYC-940 Exploded View: HYC-940 (220-240V~/50Hz)spare part list: No Code Name QTY No Code Name QTY 1 0074000248 Compressor 1 22 0070107920 Fan cover 1 2 0070702086 Condenser 1 23 0070401235 Light switch 1 3 0070702085 Exhaust tube 1 24 0070506744 Display film 1 4 0070107923A Frame assembly 1 25 0070203522 Display support 1 5 0270101277 Water collecting box 1 26 0074090955 Display board 1 6 0070401182 Power cord 1 27 0070108114 Front cover 1 7 0070107949 caster 4 28 0270101162 Fan-motor support 1 8 0270101164 Air duct board 2 29 0074090544 Inner fan-motor 3 11

9 0070105097 右 0070105098 左 Upper hinge 2 30 0270100312 Electric box 1 Beam of the temp. 10 0070107926 measurement box 2 31 0270700156 Evaporator 1 11 0070107065 Shelf bar 8 32 0074091548 Control board 1 Temp. measurement 12 0070204066 box 2 33 0074091549 Power board 1 13 0270102070 Lower hinge(left) 1 0270102071 Lower hinge(right) 1 34 0072040045 Wire joint box 1 Back board of air 14 0270100869 Shelf 12 35 0270102040 duct 1 15 0070201732C Price content bar 12 36 0270100313 Electric box 2 1 16 0074091590 LED light 6 37 0270101010 Clips of battery 1 17 0070203322A Light cover 2 38 0074091430A Battery 1 18 0070203323 Door seal 2 39 0075030020 Condenser fan 2 19 0070812074 Right glass door 1 0070812035 Left glass door 1 40 0074000186 transformer 2 Mechanical 20 0070402262C Temp. sensor 1 41 0274000087A thermostat 1 21 0270100042 Clips of shelf 48 HYC-940 (220-240V~/60Hz) spare part list: No Code Name QTY No Code Name QTY 1 0074000202 Compressor 1 22 0070107920 Fan cover 1 2 0070702086 Condenser 1 23 0070401235 Light switch 1 3 0070702085 Exhaust tube 1 24 0070506744 Display film 1 4 0070107923A Frame assembly 1 25 0070203522 Display support 1 5 0270101277 Water collecting box 1 26 0074090955 Display board 1 6 0070401182 Power cord 1 27 0070108114 Front cover 1 7 0070107949 caster 4 28 0270101162 Fan-motor support 1 8 0270101164 Air duct board 2 29 0074090544 Inner fan-motor 3 0070105097 Upper hinge(right) 1 9 0070105098 Upper hinge(left) 1 Beam of the temp. 30 0270100312 Electric box 1 10 0070107926 measurement box 2 31 0060732673 Evaporator 1 11 0070107065 Shelf bar 8 32 0074091548 Control board 1 Temp. measurement 12 0070204066 box 2 33 0074091549 Power board 1 13 0270102070 Lower hinge(left) 1 0270102071 Lower hinge(right) 1 34 0072040045 Wire joint box 1 Back board of air 14 0270100869 Shelf 12 35 0270102040 duct 1 15 0070201732C Price content bar 12 36 0270100313 Electric box 2 1 12

16 0074091590 LED light 6 37 0270101010 Clips of battery 1 17 0070203322A Light cover 2 38 0074091430A Battery 1 18 0070203323 Door seal 2 39 0075030020 Condenser fan 2 19 0070812074 Right glass door 1 0070812035 Left glass door 1 40 0074000186 transformer 2 20 0070402262C Temp. sensor 1 41 0274000087A 21 0270100042 Clips of shelf 48 Mechanical thermostat 1 HYC-940 (115V~/60Hz) spare part list: No Code Name QTY No Code Name QTY 1 0074091328 Compressor 1 22 0070107920 Fan cover 1 2 0070702086 Condenser 1 23 0070401235 Light switch 1 3 0070702085 Exhaust tube 1 24 0070506744 Display film 1 4 0070107923A Frame assembly 1 25 0070203522 Display support 1 5 0270101277 Water collecting box 1 26 0074090955 Display board 1 6 0070401182 Power cord 1 27 0070108114 Front cover 1 7 0070107949 caster 4 28 0270101162 Fan-motor support 1 8 0270101164 Air duct board 2 29 0074091557 Inner fan-motor 3 0070105097 Upper hinge(right) 1 9 0070105098 Upper hinge(left) 1 Beam of the temp. 30 0270100312 Electric box 1 10 0070107926 measurement box 2 31 0060732673 Evaporator 1 11 0070107065 Shelf bar 8 32 0074091548 Control board 1 Temp. measurement 12 0070204066 box 2 33 0074091549 Power board 1 13 0270102070 左 Lower hinge(left) 1 0270102071 右 Lower hinge(right) 1 34 0072040045 Wire joint box 1 Back board of air 14 0270100869 Shelf 12 35 0270102040 duct 1 15 0070201732C Price content bar 12 36 0270100313 Electric box 2 1 16 0074091590 LED light 6 37 0270101010 Clips of battery 1 17 0070203322A Light cover 2 38 0074091430A Battery 1 18 0070203323 Door seal 2 39 0074091408 Condenser fan 2 19 0070812074 Right Glass door 1 0070812035 Left glass door 1 40 0074091342 transformer 2 Mechanical 20 0070402262C Temp. sensor 1 41 0274000087A thermostat 1 21 0270100042 Clips of shelf 48 HYC-940 F: 13

HYC-940F spare part list: No Code Name QTY No Code Name QTY 1 0074000248 Compressor 1 21 0270100042 Clips of shelf 48 2 0070702086 Condenser 1 22 0070107920 Fan cover 1 3 0070702085 Exhaust tube 1 23 0070401235 Light switch 1 4 0070107923B Frame assembly 1 24 0070506744 Display film 1 5 0270101277 Water collecting box 1 25 0070203522 Display support 1 6 0070401182 Power cord 1 26 0074090955 Display board 1 7 0070107949 caster 4 27 0070108114 Front cover 1 Fan-motor 8 0270101164 Air duct board 2 28 0270101162 support 1 9 0070105097 Upper hinge(right) 1 0070105098 Upper hinge(left) 1 Beam of the temp. 29 0074090544 Inner fan-motor 3 10 0070107926 measurement box 2 30 0270100312 Electric box 1 14

11 0070107065 Shelf bar 8 31 0270700156 Evaporator 1 12 0070204066 Temp. measurement box 2 32 0074091548A Control board 1 0270102070 Lower hinge(left) 1 13 0270102071 Lower hinge(right) 1 33 0074091549 Power board 1 14 0270100869 Shelf 12 34 0072040045 Wire joint box 1 Back board of 15 0070201732C Price content bar 12 35 0270102040 air duct 1 16 0074091590 LED light 6 36 0270100313 Electric box 2 1 17 0070203322A Light cover 2 37 0270101010 Clips of battery 1 18 0270200538G Door seal 2 38 0074091430A Battery 1 19 0270803220 Right Foaming door 1 0270803082 Left Foaming door 1 39 0075030020 Condenser fan 2 20 0070402262C Temp. sensor 1 40 7. Instruction of operation Display panel Definition : Light:the switch of light which is in the cabinet. Indicator light for upper and lower temp.(green):distinguish upper and lower temp. (Upper and lower temp. light together means the average value of the temperature); Power indicator light(red): light means power on,flash means main power failed; Alarm indicator light(red): light flashing means alarm happened; Silence :suspend current sound alarm, but this operation cannot cancel remote alarm; Temp. Tran.:alternate the value between upper and lower temp.; Alarm test:check whether it has alarm or not; Cal. & sensor& Cal. cancel:auxiliary button for other operation. 15

Definition Of Combination Key: Sensor + Cal. cancel :setup the temperature(press at least for 5s) Temp. tran. + Cal. :calibrate the value of the five sensors(press at least for 10s) Silence + Alarm test :Factory reset (Press at least for 10s) Cal. : a. During the U-disk was inserted in,press Cal. to query the status of data exporting; b. Press Cal. at least for 10s,to set up the system time of USB board; c. After exporting the data from USB port,press Cal. for 10s to save and exit,the display panel will show the temperature of the cabinet. a. Instructions of Parameter adjustment Content Operating steps Display After turning on the power,shortly press Alarm test button Alarm test The buzzer rings 3times,and the alarm light flash 3 times, it means normal; 1.Press sensor + Cal. cancel for 5s Setup temp. 2.pres Cal. cancel to rise the value,or press sensor to reduce the value 3.After setup the vale,no operation,parameters will be saved and exit setting after 5s. 1.Press sensor + Cal. cancel for 5s 2.Follow the first step(under displaying the set value of temp. and flashing status)in3s, press Cal. For 10s Ordinary 3.When it shows SHE,In4 seconds,press Cal. Cancel or sensor,to choose the parameters current parameter,and show the value of the current parameter. 4.If no any operation,auto jump to next parameter after 4 seconds. 5.After showing all the parameter,if no operation for 10s,system will save and exit to standby status 1.Under standby, press temp. tran. + Cal. for 10 s 2.Press Sensor to show the D-value; 3.Press Cal. cancel to choose the current D-value; Calibrate the 4.Press Alarm test,to show the adjustment range parameters 5. Press cal. cancel or sensor to adjust the calibrate the D value 6.After calibration,press Cal or wait for 5s will back to D-value list 7.After calibrating all D-values,within 5s no operation, it will save the parameter and back to standby. b. Parameter definition b.1 Ordinary parameter list If it displays E5,it means low battery or the battery switch is off Display the set value of temp. and flashing Display the set value of temp. and flashing Display:SEH Display SHE s value Display next Code Display D1 D1-D2-D3-D4-D5-D1 Display the value of the sensor Display the adjust range of the sensor D1~D5 16

No. Parameter Name Adjust range 1 SEH Upper limit of setting temp. Upper limit;20 2 SEL Lower limit of setting temp. Lower 3 AOF Temp. different control of compressor (set value+0.5)±aof limit:-5 4 ALH Alarm for high temp. Upper Default value HYC-940 0.5~3.0 0.5 limit:20 5 ALL Alarm for low temp. Lower b.2 Adjustment list of temperature sensor value limit:-5 NO. Parameter Name Adjust range 8 2 10 2 Default value HYC-940 1 D1 Upper temperature sensor -2.0~+2.0 0 2 D2 Lower temperature sensor -2.0~+2.0 0 3 D3 Control temperature sensor -2.0~+2.0 0 4 D4 Defrosting temperature sensor -2.0~+2.0 0 5 D5 Alarm temperature sensor -2.0~+2.0 0 c. Special function c.1 Defrosting function HYC-940&940F Service Manual Remark Remark Auto defrosting:inner fan motor is working,compressor stop,then start defrosting function. Forced defrost: Start conditions :in stably status,before the compressor start,inspect the temp of defrosting sensor, if the temperature is lower than -0.25, the forced defrosting function will work. Defrosting status:inner fan motor and compressor stopped. Exit conditions:meet any conditions as follows: (a) Upper or lower display temp 5.6 (b) Defrosting for 20min. (c) Temperature of Control sensor or alarm sensor 7 Notice: twice defrosting time is 24hours,After forced defrosting, compressor start working,delay 3min the inner fan-motor begin to work. C.2 Safety mode for failed sensor C.3 USB storage function If the control sensor is damage,the compressor will work for 5 min and stop for 5min. content Operation steps Display Data export Set time 1.plug the usb flash disk into the usb port 2.press cal to query the status 1.press cal for at least 10s 2.press sensor or cal cancel to change the parameter USb means exporting ALL-done Show 1P 1P-2P-3P-4P-5P-1P 3.press cal choose the current parameter and display the value Show the value of 4.press sensor or cal cancel to rise or decrease the value t until proper 5.press cal save and back parameter 1P~5P 17

6.set all the parameter,press cal for at least 5s,or no operation for 10s save and exit. Notice: 1P to 5P means year, month, day, hour, minute. C.4 Self-inspection for alarm function Press alarm test button to simulate all alarm functions, make sure the buzzer,light and remote contacts work fine. d.the alarm Code Alarm Code Name Alarm type Troubleshooting E1 Upper sensor failed Buzzer &light &code Inspect upper sensor Sensor error E2 Lower sensor failed Buzzer &light &code Inspect lower sensor E3 Control sensor failed Buzzer &light &code Inspect control sensor E4 Defrosting sensor failed Buzzer &light &code Inspect defrost sensor Door open High or low temp. N/A Door open for 10min Buzzer &light Inspect door switch or close N/A The upper or lower temp. beyond the range Buzzer &light door Power failure N/A Power failed Power light &buzzer & alternate display temp. Inspect power Battery E5 Low battery or switch is off Buzzer &light &code Inspect battery or switch Remote alarm N/A Above all will trigger the remote alarm. - - Notice: For the low battery alarm, please check it by manual, Press Alarm test button, if the display panel show E5, it means the battery is poor or damaged. e.special considerations for installation 1. If the freezer includes USB board,please adjust the system time of the USB board; 2. If the freezer includes printer, Please adjust the system time of the printer; 3. The blood bank freezer is Air cooling freezer, when put the goods into the freezer, not too dense, make sure the airflow can go through the shelves; 4. The freezer has 4 wheels and 2 feet, After installation, make the two feet back to the earth, keep the freezer stably ; 18

8. Troubleshooting 1.Replace PCB (1)The PCB is fixed at the top of the cabinet, the display board is behind the front cover. Electric box (2)Remove the screws and open the cover of the electric box, the control board and power board is fixed in the electric box. Power board Control board (3)There is a oblong hole under the control board,we can push out the display panel through this hole. Display board Hole for cable 2.The position of the sensor (1) Upper and lower temperature probe is put in the measurement box. We can pull out the probe directly. Upper temp. sensor Lower sensor temp. 19

(2)Remove the inner fan cover,the control sensor and alarm sensor is behind the cover. HYC-940&940F Service Manual Upper sensor Inner door cover (3)Remove the fan motor support,we can find the evaporator, the defrosting sensor is behind the evaporator. Evaporator Inner support fan Defrosting sensor 3.Defrosting heater The defrosting heater is fixed on the evaporator. Defrosting heater 4. Mechanical thermostat (1)the main body of the thermostat is fixed beside the transformer which is protected by a plastic bag, the probe of the thermostat is fixed beside the inner fan. Main body of thermostat Probe thermostat of (2)the red wire is connected with H& C point,the yellow-green wire is connected with the earth. 20

5.The position of the cooling system (1) Compressor is on the top of the freezer. HYC-940&940F Service Manual Electric box Condenser The power box Compressor (2) The pipe of beside the compressor: maintenance tube is used for recharging the cooling system. Suction tube Drier filter Maintenance tube Exhaust tube 9. Test curve 21

Inspired living Haier Medical & Laboratory Products Co., Ltd. Room 403D, Brand Building, Haier Industrial Park, No.1 Haier Road Qingdao China Website: www.haiermedical.com 22