Antares Warewash Dispensing System

Similar documents
Antares Warewash Dispensing System

SPRITE Warewash Dispensing System

Sprite III Warewash Dispensing System

Sprite III (Alpha) Warewash Dispensing System

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

DEMA TITAN II WAREWASH CONTROL T.812 & T.813 SERIES

D3000. Installation & Setup Guide

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

NS1000E Installation & Troubleshooting

DR30 MAX Warewash Chemical Dispenser Dispensing technology by Seko UK

FLOW CONTROLLER TYPE S/601

WAREMAX SERIES. Dosing Systems for Commercial Dishmachines. Contents. WAREMAX Series Dishwasher systems. 4 Priming and Delime Mode.

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Chem-Trak Jr. Instruction Manual

DEMA I /23/18. detergent and. responds to. rinse triggers. of a pressure indicating. plumbing

Digital Marine Exhaust Temperature Alarm

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

DEMA Nitro Ware Wash Chemical Dispensing

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTRUCTION MANUAL FOR DEMA CHEMASTER TM DM-813-LLL-1T, DM-813-LLL-2T, DM-813-DLL-1T and DM-813-DLL-2T

How to Install D3000

DEMA CHEMASTER WAREWASH SYSTEM INSTALLATION AND OPERATIONS MANUAL

THX-DL Data Logger USER & INSTALLATION MANUAL V

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual

DEMA TITAN WAREWASH CONTROL T-812 & T-813 SERIES

DEMA Nitro Express Ware Wash Chemical Dispenser

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

COMMERCIAL WASHERS MODELS T-300/350/400/450/600/650/750/900/950/1200/1450 VENDED C-SERIES CONTROL

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

FCD-wire Contents. List of Figures

Service Manual Models: 1.0, 1.3, and 1.5

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Added password for IP setup page : Password must be in IP format!

Installation, Operation & Maintenance Manual. Wash System

EasyTronic III MANUAL SERVICE

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Laundry & Warewash Product Catalog

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

Introduction. OM-THA2

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

Advisor Advanced Mobile Application User Manual

Laptop / PC Programming Manual

Memcom Emergency Telephone

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Dryer Moisture Systems Inc. Dryer Master GM 2. Product Manual. Revision 1.0 January, 2007 Revision 1.01 March, Prepared by:

HYDRIM M2 WASHER-DISINFECTOR

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Revised 10/3/2002. Ellis Intellitrol Washer Control Operation Manual

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Marco Beverage Systems Ltd.

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Follett Performance Plus

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

Ice Rink (Single and Dual Configurations) Custom Control Features

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

CONTENTS. Safety. 4. NOBODY READS THIS STUFF 4.1 Spare Parts 4.2 Technical Support 4.3 Specifications 4.4 Keypad Navigator.

MicroPulse Washer Northpoint Parkway Acworth, GA

Process & TeMPerATUre UniversAl input DigiTAl MeTers

EXPERT TRI-STAR. Temperature controller. User s Manual

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Entero Voice Alarm system.

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

S/601 Controller Installation Manual

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

LineGuard 2300 Program User Manual (FloBoss 107)

TWLC - Tempered Water Logic Controller. The Intelligent Control

AMANA PHWT-A200 THERMOSTAT

Pioneer Z100 Smart Thermostat Operating and Installation Manual

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Operation and Maintenance Manual

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Operation and Maintenance Manual

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Warewash Systems. innovation > technology > future

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Service Parts

microflex Blowdown Controller for Boilers Measures Conductivity, Temperature, Make-up Water Meter and Interlock

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Retro Fit Rinse Pump Rev B

SCAN20 Series Gas Detection Controller

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

- Data Brochure Snow Detector & Melting Control 665

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Analogue Addressable Fire Panels FP1500. Manual for Installation, Configuration and Commissioning

Transcription:

Antares Warewash Dispensing System Quick Start Guide Antares Series Online and downloadable Product Manuals and Quick Start Guides are available at www. HydroSystemsCo.com Please check online for the latest version of this Quick Start Guide and Full Reference Manual. Mechanical Installation Wall Mounting 1. Choose an installation location that is: Close to the product containers. At a reasonable height for easy maintenance access and does not interfere with opening of doors. Away from any direct sources of steam, water spray, and high temperatures. Close enough to the dish machine electrical control panel to allow dispenser wiring without use of an external junction box (not provided) wherever possible. Wire harness is 11.5 feet. 2. Using mounting bracket as a template, mark holes to drill into mounting surface. For sheet metal mounting with screws and nuts, drill 1/4 (6 mm) holes. For wall anchors, drill holes as appropriate for anchors used. 3. Attach mounting bracket to mounting surface with hardware provided. 4. Hang unit on bracket.! WARNING: The Antares dispensing system is intended to be installed by experienced installers in accordance with all applicable electrical and plumbing codes. All dish machine and dispenser power must be disconnected during installation and/or any time the dispenser cabinet is opened. Mounting Bracket Back of Unit Hang unit from this lip on to Mounting Bracket Figure 1-1 Mounting Bracket NOTE: Always use proper lockout tagout procedures when servicing the dispenser. P/N 10096881 Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 1

Electrical Installation Probe Wiring (Probe Mode) Rubber Gasket Retaining Nut Lock Washer 1. Route the probe wire to the probe location. If you need to extend the probe wire, use high quality corrosion resistant (waterproof is best) butt splices with a good quality crimping tool. 2. Strip wire ends and crimp on the ring terminals provided. 3. Connect the ring terminals to the probe with nuts and lock washers provided. Be sure that connections are tight and secure. 4. For optional rinse temperature probe installation, please refer to instructions provided in kit. 5. For optional tank temperature probe installation, please refer to instructions provided in kit. Dish Machine Tank Wall Plastic Washer Rubber Gasket Nut Ring Terminal Figure 2-1 Probe Wiring Sequence Nut Main Power Wiring Connect the blue wire to one side of the voltage source. Connect the brown wire to the other line of the voltage source. See figure 2-2. Signal Wiring The detergent and rinse signal inputs are optically isolated and accept voltage from 24-240VAC or 24VDC. See figures 2-3 and 2-4. Brown Blue Main Power Line Line (+)Yellow (-) White/Yellow Line Detergent Signal 24-240 VAC~50/60Hz or 24 VDC (+) Violet (-) White/Violet Line Rinse Signal 24-240 VAC~50/60Hz or 24 VDC Figure 2-2 Main Power Connections Figure 2-3 Detergent Signal Wiring Diagram Probe or Probeless Mode NOTE: If an external optional device will be used, you must supply your own wire. Figure 2-4 Rinse Signal Wiring Diagram Programming Menus, Screens, and Setup Keypad, Menus, and Symbols The keypad is designed for easy operation. Directional keys (Up, Down, Left, Right) let you navigate through menus. The Enter key allows you to enter commands and choices as well as start or stop actions, and the Back key takes you to your previous screen. Keypad Buttons Selection Box Edit Value Arrows Scroll Arrows Flashing Bars BACK ENTER UP/DOWN LEFT/RIGHT P/N 10096881 Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 2

Programming Menus, Screens, and Setup FINAL RINSE TIME Rinse Pump RPM Settings Guide MLS DESIRED PER RACK 1 1.5 2 2.5 3 3.5 4 4.5 5 6 20 30 40 50 60 8 15 23 30 38 45 53 60 10 12 18 24 30 36 42 48 54 60 12 10 15 20 25 30 35 40 45 50 14 9 13 17 21 26 30 34 39 43 15 8 12 16 20 24 28 32 36 40 16 8 11 15 19 23 26 30 34 38 18 7 10 13 17 20 23 27 30 33 20 6 9 12 15 18 21 24 27 30 PUMP RMP SETTINGS Alarm Messages DETERGENT OVERFEED STOP! CHANGE THE PRODUCT CONTAINER BEFORE CLEARING Detergent Overfeed Stop Alarm MACHINE CLEAN! PERFORM A DE-LIME CYCLE ON THE WASHER Machine Clean Alarm COND PROBE FAULTY! CHECK DET PROBE FOR DAMAGE OR FOULING Conductivity Probe Faulty Alarm COND PROBE FAULTY! DO YOU WISH TO SWITCH TO PROBELESS MODE < YES NO> Conductivity Probe Faulty Alarm SQUEEZE TUBES NEED TO BE CHANGED! Squeeze Tube Change Alarm CHANGE TANK! RACKS RUN SINCE LAST INITIAL FILL HAS BEEN EXCEEDED Change Tank Alarm LOW RINSE TEMPERATURE Low Rinse Temperature Alarm PUMP 1 JAM CHECK DISPENSER Pump Jam Alarm CONDUCTIVITY PROBE NOT CALIBRATED Probe Not Calibrated Alarm P/N 10096881 Hydro Systems Company, Inc. 2014 HydroSystemsCo.com Toll Free: 1.800.543.7184 3

Home Screen NOVA CONTROLS Racks: 00 PROBE Cond: WTemp: Setpt: RTemp: Signl: 1 0 Pump: DET RIN SAN Alarm: ** LOWDET 1.0 USER MENU USER PRIME PUMPS DE-LIME CYCLE MAX DETERGENT TIME MANUAL INITIAL CHRG ACCESSED BY PRESSING ANY OTHER NAVIGATION KEY 1.1 1.2 SET PRIME PUMP 1.1.1 PRIME 1.2.1 1.1.2 SET PRIME PUMP D <EXIT START DE-LIME THIS WILL STOP ALL OPERATION CONTINUE? DE-LIME CYCLE TIME REMAINING: 09:59 <EXIT 1.3 MAX DET TIME 05:00 MM:SS <EXIT RESET> 1.4 MANUAL CHARGE DO YOU WISH TO START MANUAL INITIAL CHARGE? 1.4.1 MANUAL CHARGE TIME REMAINING: 199 SEC <EXIT 2.0 PROGRAM MENU MANAGER REPORTS INSTALLER MENU 2.1 MGR PASSWORD <0123> 2.2 INSTL PASSWORD 2.2.1.1.1 DETERGENT CNTRL PROBE PROBELESS 2.2.1.1.5 2.2.1.1.9 DISP RINSE TEMP ACCESSED BY PRESSING BACK KEY REPORT DATE FROM: <2012-01-01> REPORT DATE TO: <2012-05-28> REPORT NAME <REPORT> <01234> UNITS - MEASURE SAE/IMPERIAL (LB/OZ) METRIC (KG/ML) 2.1.1 2.1.2 2.1.3 2.2.1 INSTALLER MENU CONFIG SETTINGS PROGRAM SETTINGS SETTINGS INSTALLER SERVICE INITIAL SYSTEM SETUP DATA TRANSFER 2.2.1.1 CONFIG SET- TINGS DETERGENT CNTRL MACHINE TYPE DETERGENT TYPE OPTION UNITS OF MEASURE <AUTO SWITCH MODE> 2.2.1.2, 2.2.1.3, 2.2.1.4, 2.2.1.5, 2.2.1.6 >>> CONTINUE ON FOLLOWING PAGES User Menu/ Program Menu DISP LIVE COND DISP RINSE TEMP USER PRIME PUMPS INITIAL CHARGE <CONV RACK TIME> 2.2.1.1.2 MACHINE TYPE DOOR CONVEYOR ALTERNATE DOOR 2.2.1.1.6 AUTO SWITCH MODE 2.2.1.1.3 2.2.1.1.4 DETERGENT TYPE LIQUID CAPSULE OPTION OFF INTERNAL EXTERNAL BOTH 2.2.1.1.7 2.2.1.1.8 DISP LIVE COND CONVEYOR TIME <00 SEC> 2.2.1.1.10 2.2.1.1.11 2.2.1.1.12 2.2.1.1.13 USER PRIME LIMITED 30 SEC INITIAL CHARGE AUTOMATIC MANUAL PULSE FEED OFF -NO PULSE FEED 1-ON 9-OFF 50% SPT 1-ON 9-OFF 70% SPT 2-ON 6-OFF 50% SPT 2-ON 6-OFF 80% SPT (DEFAULT) 4-ON 4-OFF 70% SPT 6-ON 4-OFF 80% SPT 3 RD PRODUCT RUN RINSE DETERGENT

Program Menu/Program Settings 2.2.1.2 P (PROBE DETERGENT CONTROL) PROG SETTINGS DETERGENT SETPNT DETERGENT SPEED RINSE PUMP SPEED RINSE FEED OPTION RINSE DELAY TIME THIRD PROD SPEED 2.2.1.2.1 2.2.1.2.1.1 2.2.1.2.1.2 DET SETPOINT MANUAL ADD ENTER SETPNT MANUAL ADD PROD TANK READING: ENTER SET POINT <> USE TANK READING TANK READING: SET POINT: 2.2.1.2.2 2.2.1.2.2.1 2.2.1.2.2.2 RINSE PUMP SPD RINSE PUMP SPD TEST PUMP 20.5 RPM 00.0 RPM 20.5 RPM 2.2.1.2.3 RINSE FEED OPT RINSE ON RINSE RINSE ON DET 2.2.1.2.4 RINSE DELAY TIME < SEC> 2.2.1.2.5 2.2.1.2.5.1 2.2.1.2.5.2 3 RD PRODUCT SPD 3 RD PRODUCT SPD 3 RD PRODUCT SPD 110 RPM 00.0 RPM 110 RPM 2.2.1.2 PL (PROBELESS DETERGENT CONTROL) PROG SETTINGS DET INITIAL CHARGE DETERGENT DOSE DET DOSE INTRVAL LOW DET THRSHLD RINSE PUMP SPEED RINSE FEED OPTION RINSE DELAY TIME 3 RD PROD PUMP SPEED 2.2.1.2.1 PL DET INIT CHARGE 012 SEC 2.2.1.2.2 PL DET DOSE 02 SEC 2.2.1.2.3 PL DET DOSE INTRVL 1 RACKS 2.2.1.2.4 PL LOW DET THRSHLD 00 RACKS 2.2.1.2.5 PL 2.2.1.2.5.1 PL 2.2.1.2.5.2 PL RINSE PUMP SPD RINSE PUMP SPD TEST PUMP 20.5 RPM 00.0 RPM 20.5 RPM 2.2.1.2.6 PL RINSE FEED OPT RINSE ON RINSE RINSE ON DET 2.2.1.2.7 PL RINSE DELAY TIME < SEC> 2.2.1.2.8 PL 2.2.1.2.8.1 PL 2.2.1.2.8.2 PL 3 RD PRODUCT SPD 110 RPM 3 RD PRODUCT SPD 00.0 RPM TEST PUMP 110 RPM

Program Menu/ Alarm Settings 2.2.1.3 2.2.1.3.1. 2.2.1.3.1.1 2.2.1.3.1.1.1 LOW DET LOW DET SETTINGS LOW DET/OVERFEED MACHINE CLEAN PROBE FAULTY CHANGE SQZ TUBE CHANGE TANK LOW RINSE TEMP RACKS RUN LOW: 0 SETTING: 0 0 2.2.1.3.2 2.2.1.3.2.1 MACH CLEAN RK 100 2.2.1.3.3 2.2.1.3.3.1 2.2.1.3.3.2 COND PROBE MIN COND PROBE MAX PROBE FAULT RACK RACKS 2.2.1.3.4 CHG TUBE TIME 180 DAYS 2.2.1.3.5 CHG TANK RACK 00 RACKS 2.2.1.3.6 LOW RINSE TEMP 150 DEG F

Program Menu/ Installer Service 2.2.1.4 2.2.1.4.1. INSTALLER SERVICE SERVICE PUMPS VIEW AMOUNT PUMPED CLEAR DATA LOG SERVICE PUMPS VIEW PUMP CONFIG NAME PUMPS PUMP CALIBRATION PRIME PUMP ENTER PRODUCT COSTS TUBE REPLACEMENT SET PUMP TYPE SET PUMP PRODUCT SET PUMP INSTALL 2.2.1.4.1.1 VIEW PUMP CONFIG TYPE PROD INST P1 SOL DET YES P2 PUMP RIN YES P3 PUMP SAN NO 2.2.1.4.1.2 2.2.1.4.1.2.1 SELECT PUMP NAME PUMP (P1) 2.2.1.4.2 PUMPED (GAL.) 18.5 26.2 38.0 2.2.1.4.3 CLEAR DATA LOG WARNING! ALL LOGS WILL BE CLEARED <DETERGENT> 2.2.1.4.1.3 2.2.1.4.1.3.1 2.2.1.4.1.3.2 2.2.1.4.1.3.2.1 2.2.1.4.1.3.2.1.1 PUMP CALIBRATION PUMP CALIBRATION PUMP CALIBRATION CALIBRATE ML REV VIEW CALIBRATION CALIBRATE 0.300 0.125 0.200 2.2.1.4.1.4 2.2.1.4.1.4.1 SET PRIME PUMP PRIME CALIBRATE STOP PUMP AT 8 OZ. WARNING! PLACE CONTAINER AT OUTPUT!.00 2.2.1.4.1.5 2.2.1.4.1.5.1 PRODUCT COSTS P3 COSTS/GAL <0.00> 2.2.1.4.1.6 2.2.1.4.1.6.1 TUBE REPLACEMENT P3 DATE CHANGED <2013-01-05> <OK EXIT> 2.2.1.4.1.7 2.2.1.4.1.7.1 SELECT PUMP SET PUMP TYPE SOLENOID PUMP 2.2.1.4.1.8 2.2.1.4.1.8.1 SELECT PUMP SET PRODUCT DET RINSE SAN 2.2.1.4.1.9 2.2.1.4.1.9.1 SELECT PUMP PUMP INSTALL NO YES

Program Menu/ Systems Setup 2.2.1.5 SYSTEM SETUP EDIT INST PASSWORD EDIT MGR PASSWORD EDIT ACCOUNT NAME EDIT MACHINE NAME EDIT COMPANY NAME EDIT MACH NAME EIDIT CONTACT NAME SET LCD CONTRAST SET DATE & TIME CLEAR SETTINGS VIEW SOFTWARE ID VIEW SERIAL NUM SIGNAL DSP EXIT SOL ELECTRIC COST/KWH WATER CST/K UNITS FULL KW PWR USAGE IDLE KW PWR USAGE WATER VOL/WASH COND RANGE MAX 2.2.1.5.1 2.2.1.5.9 2.2.1.17 INSTL PASSWORD <0123> 2.2.1.5.2 2.2.1.5.10 MGR PASSWORD <0123> DATE & TIME <0-00-00> <00:00> YYYY-MM-DD HH:MM CLEAR SETTINGS WARNING! ALL SETUPS WILL BE CLEARED TO FACTORY DEFAULTS! 2.2.1.5.10.1 2.2.1.18 CLEAR SETTINGS ARE YOU SURE? 2.2.1.5.3 2.2.1.5.11 2.2.1.19 ACCOUNT NAME SOFTWARE ID WATER VOL/WASH ANTARES DM6 <RESTAURANT-087> P/N: NN-NNNNN-NNN REVN NNNN FULL KW PWR IDLE KW PWR 2.2.1.5.4 2.2.1.5.12 MACHINE NAME SERIAL NUMBER <KITCHEN 01> 12345678901234 2.2.1.5.5 2.2.1.5.13 COMPANY NAME SIGNAL DSP <NOVA CONTROLS> 2.2.1.5.6 2.2.1.5.14 EDIT MANF NAME EXT SOL < > 0 2.2.1.5.7 2.2.1.5.15 EDIT CONTACT NAME ELECTRIC CST/KWH < > 0.00 2.2.1.5.8 2.2.1.5.16 LCD CONTRAST WATER CST/K UNITS 5 0 0.00

Program Menu/ Data Transfer 2.2.1.6 DATA TRANSFER WRITE REPORTS READ SETUP 2.2.1.6.1 2.2.1.6.1.1 WRITE SETUP UPDATE FIRMWARE REPORT DATE REPORT DATE FROM: TO: 2013-01-01 2.2.1.6.2 2.2.1.6.2.1 2.2.1.6.2.2 SETUP FILE STD DOOR SETUP STD CONVEYOR BOBS BURGERS PUB AND GRUB JOES CAFE 2.2.1.6.3 2.2.1.6.3.1 SETUP FILE < V W X Y Z > INSERT USB DRIVE 2013-05-28 WARNING THIS WILL OVERWRITE EXISTING SETTINGS AND FORMULAS WARNING NAME EXISTS! OVERWRITE EXISTING FILE? 2.2.1.6.1.2 2.2.1.6.1.2 REPORT NAME <UVWXYZ> INSERT USB DRIVE ERROR UNABLE TO READ FILE WARNING NAME EXISTS OVERWRITE EXISTING FILE NAME? 2.2.1.6.4 2.2.1.6.4.1 UPDATE FIRMWARE UPDATE FIRMWARE STOP!!! DO NOT PROCEED WITHOUT PC UPDATE PROGRAM CONNECT PC AND BEGIN UPDATE 3.0 SECTION 3.1 DETERGENT OVERFEED STOP! CHANGE THE PRODUCT CONTAINER BEFORE CLEARING 3.2 MACHINE CLEAN! PERFORM A DE-LIME CYCLE ON THE WASHER 3.3. COND PROBE FAULTY! CHECK DET PROBE FOR DAMAGE OR FOULING 3.4 COND PROBE FAULTY! DO YOU WISH TO SWITCH TO PROBELESS MODE < YES NO> 3.5 SQUEEZE TUBES NEED TO BE CHANGED! 3.6 CHANGE TANK! RACKS RUN SINCE LAST INITIAL FILL HAS BEEN EXCEEDED 3.7 LOW RINSE TEMPERATURE 3.8 PUMP 1 JAM CHECK DISPENSER 3.9 CONDUCTIVITY PROBE NOT CALIBRATED