V80-H Multistage Pump Instruction Manual

Similar documents
VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - Rain2Main Automatic Rainwater Controller

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

PRESSURE ASSEMBLIES WITH ONE PUMP

Classic Heater Pool Controller

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

SELF-PRIMING JET PUMPS

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

KADO LUX LED EXHAUST FAN 200

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

DIRTY WATER SUBMERSIBLE PUMP

PJ130S High Pressure Cleaner

OPERATION & MAINTENANCE INSTRUCTIONS

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

APW-VAP-150P High Pressure Cleaner Operator Manual

Super Super Super Works Super Super Works

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

Instructions for installation and use English. More documents on: H B /09

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

DIRTY WATER SUBMERSIBLE PUMP KIT

Classic Heater Spa Pool Controller

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

NON-SUBMERSIBLE WATER PUMP

Sunbeam Tower Fan with Night Mode

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

SUBMERSIBLE DIRTY WATER PUMP

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

SAFETY AND OPERATING MANUAL

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

STEAM MOP S3251NZGN OWNER S GUIDE

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

ISSY GLIDE VANITY UNIT

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Installation and Operating Instructions for Davey BF Series Pressure Booster Systems with Flow Switch Control

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

SAFETY AND OPERATING MANUAL. All-in-One blower/ vac/mulcher WG502E

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMPS

CLEAN WATER SUBMERSIBLE PUMP

PoolSweepa FloorCova Pool Cleaner. Operating Instructions

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

LC Series - Light Commercial Pump Station Installation and Operation Manual

DIRTY WATER SUBMERSIBLE PUMP

OPERATING & MAINTENANCE MANUAL

BLOW DRY & GO HAIR KIT

100 Series Maxi Internal Filters

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

X1 series Submersible Drainage Pump

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Flomate Mains Boost Pump Installation & Maintenance Instructions

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

2 IN 1 SUBMERSIBLE PUMP

Electrical Mini Tank Water Heater anual, and Warranty nformation

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

MODEL 7000 SUCTION UNIT

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

MILLI CUBE HEATED TOWEL RAIL 825 X 600

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Convection Panel Heater

Built in Electric Ceramic Hob. Instruction Manual

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Portable Air Conditioner

AC-12200E Portable Air Conditioner

WET & DRY WORKSHOP VAC

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

CONSTANT PRESSURE PUMP

User Guide Vax Careline: AU: NZ:

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

INTRODUCTION SPECIFICATIONS. Pump Flow Curve

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Operating Instructions

Submersible Grinder Pump Type ABS Piranha S10 - PE125

Transcription:

V80-H Multistage Pump Instruction Manual

PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and suction performances. TABLE OF HYDRAULIC PERFORMANCE 50 45 40 CONSTRUCTION 35 Pump Casing Motor Bracket Impeller Diffusors X5 CrNi 1810 (AISI 304) stainless steel Die-cast aluminium Technopolymer with X5 CrNi 1810 (AISI 304) stainless steel shim ring Technopolymer Head (m) 30 25 20 V80-H V80-H + V-PC Shaft X12 CrNiS 1809 (AISI 416) stainless steel 15 Mechanical Seal Counterface Graphite Ceramic 10 Seal Holder Plate GFN2V Noryl 5 O-ring NBR 70 Shore 0 0 10 20 30 40 50 60 70 80 90 100 l/min USAGE LIMITATIONS Type of liquid: clean water with no suspended solids or abrasive material Maximum liquid temperature: 50 O C Maximum/Minimum ambient temperature: 40 O C / 5 O C Maximum recommended suction height: 7m with foot valve Maximum operating pressure: 7 bar WARRANTY You have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property. This warranty does not include faults caused by Unsuitable or improper use Incorrect installation Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences MOTOR Enclosed, externally ventilated Level of protection IP44 Class F insulation Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding Thermal protection built into the motor winding Speed of rotation 2850 rpm Suitable for continuous use To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect. PUMP PERFORMANCE Model PUMP DIMENSIONS Nominal power Absorbed power Voltage Amp µf Q L/1 0 20 40 60 80 HP kw HP kw m3/h 0 1.2 2.4 3.6 4.8 V80-H 0.75 0.55 1.1 0.8 1~230V 4 12.5 Model C D A SUCTION PORT Dimensions (mm) Discharge head in meters OUTLET PORT 45 36 28 17 1 A B C D Suction Port Outlet Port kg V80-H 129 370 182 176 1 F 1 F 8 B Weight

INSTALLATION Please pay careful attention to the following warnings signs and indications. Only qualified, licensed personnel should install pump. The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IP44 rated products. These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation. Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions. The pump is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive environment or near combustible matter. Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor from heat damage during operation. If the supply cord is damaged, it must be replaced by the manufacturer, it s service agent or similarly qualified persons in order to avoid a hazard Children should be supervised do ensure they do not play with the appliance GENERAL INSTALLATION 1. Fitting an Auto Pressure Control or Mains Water Switch Over Device If you are using a Vada Auto Pressure Control or a Mains Water Switch Over Device with your pump, connect it either directly to the top of the pump or in a suitable position in line with the delivery piping. For further instructions on connecting these devices, please refer to the manual supplied with your unit. Ensure that the power lead remains disconnected until you have completed the installation process. 2. Locating the Pump Find a location for your pump as close to your water source as possible. Ensure that this location is stable, dry and on a separate footing from your home. To do this you can mount the pump on a concrete base. 3. Power Source Arrange for an electrician to install a 10A weatherproof outdoor power point near the pump if there is not one there already. 4. Suction This is the most important part of the installation as errors will cause significant problems for the system in performance and longevity. A gate valve must be installed at the water source outlet. To maintain optimum performance from your pump, the suction pipe should be: Kept to the shortest length practical. Re-enforced crush resistant (non-collapsible) hose or pipe. All fittings should be air tight. Pipes should be equal to or larger than the diameter of the suction/inlet port. When pumping from a well/pit etc. a foot valve should be installed on the suction pipe. Optional: Fitted with a suction Strainer/Filter* *In-line strainers/filters are only recommended for pumps fitted with a Vada Auto Pressure Control or a Mains Water Switch Over Device. Regular maintenance is required to keep them clean and provide maximum pump pressure. 5. Discharge The length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipe work should be supported independently of the pump. If you want to test that the pump is operating correctly prior to having the plumbing connected, attach a hose with a trigger nozzle to the top of the pump or the connected discharge hoses/pipes. 6. Pump Priming Ensure that there is at least 200mm of water in your tank, (i.e. that the tank outlet is covered, and the pump will not draw any air into the system). Open the gate valve on the water source. Check for any leaks, and repair these if necessary. PREPARING FOR INSTALLATION Inspect your pump, ensuring that it is well packaged and has not been damaged in transport. If the pump is damaged, report it to the Reece branch where the pump was purchased. Make sure the suction piping is completely air tight and is laid so that there can be no air locks. Warranty of these pumps is void unless they are operated in accordance with these instructions. If no leaks are present, remove the priming plug to open the priming port on the top of the pump case. If the tank is above the level of the pump, water will start to run out of this port. Replace the priming plug carefully. Your pump is now ready to run. If the tank water level is below the level of the pump, you will need to fill the pump body and suction line. Remove the priming plug and fill the pump body and suction line using a funnel. PUMP PROTECTION The pump should be protected from the weather, floods, chemicals, dust, vermin and insects. It is recommended that the pump be housed in a weather proof, well vented enclosure.

ELECTRICAL INSTALLATION SERVICE AND MAINTENANCE This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. The pump must be supplied by an outlet protected by a residual current device or earth leakage circuit breaker with a maximum rated residual current of 30mA Pump should only be serviced by qualified personnel. For best results, use only genuine service parts. Be sure to prime pump before starting. Liquid may be HOT, release pressure with care before servicing. The pump is supplied with: A fixed cable featuring a weatherproof IEC socket A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug. If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug. If you are installing a Vada Auto Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device. Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced component life or seriously damage pump and voids warranty. For additional protection, the pump must be supplied from an outlet protected by a residual current device RCD (also known as an Earth Leakage Circuit breaker ELCB) with a maximum rated residual current of 30mA. OPERATION To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor and remove plug from power outlet before working on pump or motor. GENERAL CARE AND MAINTENANCE Under normal conditions VADA pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor. If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place. TROUBLE SHOOTING GUIDE Symptom Cause Remedy The pump operator or owner must be provided with this owner s manual. This must be read before operation, and followed during operation. Ensure that your pump is filled with water before operating. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor for heat damage during operation. DO NOT RUN PUMP DRY Ensure that your pump is primed before operating The motor will not start, no water is pumped No electricity Ensure that the pump is connected to a live outlet Motor protection tripped Defective condenser Shaft blocked Verify the cause and reset the switch. If the thermal circuit breaker has tripped wait for the system to cool down Replace the condenser Verify the cause and unblock the pump The motor runs but no water is pumped The pump is sucking air Makes sure that the joints are airtight The pump rotates in the wrong direction Check that the level of liquid has not dropped below the minimum priming level. Reset the direction of rotation START-UP/OPERATION Open all valves in the suction and discharge lines. When the power is turned on, the pump will start to pump water. Without an Auto Pressure Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off. Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that came with your unit. The system is now ready for use. If no water is delivered, check the troubleshooting section. The pump stops after running for a short period of time because the thermal motor circuit breaker trips The power supply does not conform with the data on the nameplate A solid object is blocking the impellers The liquid is too thick Check the voltage on the power supply cable leads Call 1800 032 566 for your nearest Reece branch Call 1800 032 566 for your nearest Reece branch. You may need a different type of pump