Ventilation Basics How Do Your Pigs Feel? Amy Woods, DVM Rensselaer Swine Services, P.C.

Similar documents
SowBridge. Basic Environmental Factors & Their Effects on Pigs. Importance of Ventilation for Pig Comfort

Basic Ventilation Considerations for Livestock or Poultry Housing

Design and Management. Managing Your Unseen Employee: The Ventilation System

Control Strategies and Considerations for Livestock and Other Farm Buildings

EVALUATION OF SWINE FACILITIES VENTILATION

9/5/12. Emergency Thermostats Is this your override thermostat? Verify Emergency Equipment. Routine Test and Written History of Test

ENVIRONMENTAL CONTROL FOR CONFINEMENT LIVESTOCK HOUSING

Heat Exchangers in Swine Facilities

Facility Maintenance and Modernization

Ventilate Your Swine Nursery Building

Manure Pit Ventilation in Confinement Livestock Buildings

Considering Filtration. Austin Baker Ventilation Director Hog Slat, Inc

Dairy Housing Ventilation Options for Free-Stall Barns H.K. House, P.Eng.

Managing Your Unseen Employee: The Ventilation System. The Pig and It s Environment. Keeping Pigs Eating in Hot Weather

HOG FINISHING FACILITY PERFORMANCE

Outline. Mixing fans / Cooling fans. Ventilation means air must. Ventilation. Energy Efficiency for Animal Housing. Environmental Control Systems

GENERAL OBSERVATIONS FROM THE PHES EVALUATIONS TO DATE AVERAGE ANNUAL PROPANE USE

Natural Ventilation for Poultry

TPA 2018 Educational Seminar

Construction, Insulation, and Ventilation of Game Bird Facilities 1

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Acknowledgements. Copyright 2005, Aviagen, Inc., all rights reserved.

Chore-Time Fan Guide For Tunnel and Other Applications

Cooling Swine. Extension Bulletin E-1748 February 1987 (Reprint) HOUSING. Heat Dissipation

FAN VENTILATION PRINCIPLES AND RATES

Energy Efficient Houses. The majority of electricity is used by: tunnel fans during hot weather, and, by lights during cold weather.

In-Field Quantification of Fan Performance in Tunnel-Ventilated Freestall Barns ABSTRACT INTRODUCTION

, 'I... " ENTILATION FOR SWINE / I / / I / I / UNIVERSITY OF flunois / I / SGRICULTUR~.uBRM~ '" ""'... I I \ / I I. , I \ CIRCULA~~G COpy I 1// 1\\

Field Performance Evaluation of a Ventilation System: A Swine Case Study

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

Novel Livestock Housing Webinar A Novel Approach to Confined Calf Barn Ventilation

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Manual Supplement. Product/System Title: Premium Clean Room Monitor. Contents of this manual supplement include:

Select an agricultural ventilation fan for the

Open Cooling Tower. Equipment Layout Guide

Minimum Ventilation to Maximise Broiler Farm Performance. Ing.. Winfridus Bakker Cobb-Vantress

Platinum Touch/Rotem One Touch

Please note: 1. The farm case studies in the following pages are in no particular order. 2. The order the case studies appear in the following pages

Selecting an Environmental Test Chamber

Aerating Farm -Stored Grain

Bosch 80% AFUE Gas Furnace BGS80 Model

Field Start-Up Sheet Direct Fired Gas Equipment

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Evaporative Cooling Systems

Heat loss: the Reason for Heating

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Because you want reliability, versatility, and value in one complete electronic control package

Well Insulated Houses: Helping to Stay Warm in Winter and Cool in Summer

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

VENTILATING AND HEATING SMALL LIVESTOCK ROOMS

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Positive Pressure Filtered Swine Facilities

Cumberland Heating Systems

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

MBPA Home Performance FIELD DATA COLLECTION FORM

Cooling Systems for Georgia Dairy Cattle. Dr. John W. Worley, Extension Engineer

OPERATION MANUAL OPERATION MANUAL FREE. instructional videos are available online at: youtube.com IMPORTANT SAFETY INFORMATION DO NOT DISCARD

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

Ventilating Pig Buildings

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

EDSTROM Cooling Systems for Swine

EqUIPMENT LAYOUT MANUAL

Owner s Manual Super-Slim Four-Way Cassette

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

ACME ACME ENGINEERING & MANUFACTURING PB100 SPC-D INLET CONTROLLER. ACME ENGINEERING & MANUFACTURING CORP. PO BOX 978 Muskogee, OK 74402

Introduction to Fans. The Basics of Fan Principles and Terminology

AIR SHOWERS CAP701 SERIES

Desiccant Dehumidification - Effective Strategy for Drying Concrete Slabs

V ENTILATION V IEWS. News, opinions, ideas and technical advice from the ventilation specialists at Air Vent

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

USER S INFORMATION MANUAL

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

and SHUTTERS Made to Work. Built to Last.

Environmental Control for Today s Milking Center

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

SMART+ PRODUCTS Infrared Heater. Safety Notice

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019

Fan Selection. and Energy Savings

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

DESICCANT DEHUMIDIFIER

Energy Saving Fact Sheet Agriculture & Horticulture

Green Flag Level Two Survey: Indoor Air Quality Program

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Packaged Gas/Electric

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Healthy, comfortable and energy-efficient ventilation

WHITE PAPER.

GLOBAL FINISHING SOLUTIONS

KIC Air Curtains. Technical Guide

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Greener Finisher Barns Could Reduce Emissions and Improve the Bottom Line.

Environmental Control for Greenhouse Tomatoes

Advanced Installation and Configuration Instructions

Environmental Control for Greenhouse Tomatoes

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

HE-B Series Commissioning Report & User Guide

Transcription:

Ventilation Basics How Do Your Pigs Feel? Amy Woods, DVM Rensselaer Swine Services, P.C.

Purposes of Ventilation Control temperature and humidity Control dust and gas levels Provide adequate oxygen Provide optimal animal environment and worker comfort

Temperature Control 100 Recommended Effective Environmental Temperature* For Pigs Effective Environmental Temperature* ( o F) 90 80 70 60 50 10 25 40 55 70 85 100 115 Pig Weight (lbs.) 130 145 160 175 190 205 220 235 250 * The effective environmental temperature (EET) is the actual air r temperature adjusted for effects of draft, flooring type, building insulation n and supplemental cooling. The EET is what pigs really feel.

Factors Affecting Effective Environmental Temperature Environmental Factor Draft 30 ft/min (0.34 mph) 90 ft/min (1.0 mph) 300 ft/min (3.4 mph) Building insulation High Moderate Poor Change in EET ( 0 F) -7-13 -18-1 -3-13 Environmental Factor Flooring Type Straw Lying mat Plastic coated wire Plastic slats Dry concrete Uncoated steel wire Wet concrete Cooling Systems Cool cells Change in EET ( 0 F) +7 +5-7 -7-9 -9-18 -5 Fogger/mister -6 Drip coolers -10 Sprinkler -10

Measuring Temperature High/low thermometers Know how to read! Remember to reset! Lowest Temperature (52 o F) Highest Temperature (82 o F) Also remember to rely on the behavior of the pigs as an indicator of their comfort!!! Current Temperature (70 o F)

Temperature Probe Placement Temperature probes Ensure proper placement Near pig level Not in front of inlet or heater Not in PVC tube

Relative Humidity Goal: 50-70% Can be measured with a thermohydrometer Only measure when minimum ventilation is running May have probes attached to controllers Probes do not last long in barn environments and are therefore inaccurate

Relative Humidity Effects RH too high Condensation apparent on pipes, etc. Increased bacterial load Under-ventilation RH too low Excess dust and gas levels Increased LP costs due to over-ventilation ventilation

Ventilation Curve At lower temperatures, ventilation rate is based entirely on moisture control This is when the minimum ventilation fans only are running After reaching the setpoint,, ventilation is based on heat removal Additional stages of fans turn on

Mechanical Positive pressure Types of Ventilation Force air into barn through distribution tube Negative pressure/exhaust Natural Tunnel Sidewall or attic inlets May also utilize circulation fans

Ventilation Changes With The Seasons Multiple ways to ventilate a single barn Tunnel in hot weather Natural in mild weather Bring air through inlets in cold weather Minimum ventilation Ventilate based on moisture removal Maximum ventilation Ventilate based on heat removal

cfm Requirements Cfm/hd Cold Weather Mild Weather Hot Weather Sow & Litter 20 80 500 Prenursery 12-30# 2 10 25 Nursery 30-75# 3 15 35 Grower 75-150# 7 24 75 Finisher 150# + 10 35 120 Sows & Boars 12 50 300

Approximate Fan Capacity Fan Diameter 12 18 20 24 36 48 Approximate cfm 2,000 3,000 4,000 6,000 10,000 20,000

Fans Must Be Fully Operational Keep them clean A layer of dust on the fan and louvers can decrease fan efficiency by 20% Keep motors and belts maintained Shield fans from prevailing winds Decreased efficiency if fans must work against wind forces

Inlets Needed Place inlets no closer than 16 ft apart and no further than 24 ft apart Inlets should be no farther than 75 ft from the fan 1 ft 2 inlet for every ~800 cfm Ensure that airflow from inlets is not obstructed within the barn Airflow is dependant on inlet location, not fan location

Sidewall inlets OK for buildings up to 35-40 ft. wide Ceiling inlets Required for sufficient air movement in wider barns Inlet Locations

Effective Inlet Openings Remember that calculated inlet opening is often not equal to the effective inlet opening Wire screens = 80% Dirty soffits Plugged soffits

Other Inlets Ridge vents Doors Holes in curtains Sagging curtains Cracks in walls Non-operational operational fans Pits Especially if no dividers between rooms

Make Sure Natural Ventilation Is Not Obstructed Objects near a barn will block air movement for a distance of 3-43 4 times the obstacle s s height 80 ft 20 ft

Inlet Air Velocity Goal: 800 1000 ft/min If to much inlet opening for current fan capacity, velocity will decrease Air drops too soon and creates drafts on the pigs Want to have incoming air dump onto dunging areas in winter and sleeping areas in summer

Inadequate Inlet Openings Starved fans Burn up fan motors Increased static pressure Pressure difference between inside and outside the barn Measured with a manometer

Static Pressure Goal: 0.04-0.1 in. water Static pressure directly related to inlet air velocity Static Pressure (in. H2O) 0.03 0.04 0.05 0.06 0.07 Air Velocity (fpm) 600 700 800 900 1000

Know Your Controller All are different Read the manual Variable stages Temperature curves Understand the settings Bandwidth Differential Offset

Bandwidth Bandwidth = Temperature difference (in degrees) between minimum and maximum speed for variable speed fans Should always be at least 1 o Set wider as pigs grow and cfm requirements increase Set higher in winter to allow barn time to respond to changes before activating next stage

Differential And Offset Used for single speed fans and heaters Differential = heater/fan run time (in degrees) Offset = # degrees heater goes off under setpoint or # degrees for fan to come on over setpoint Offset + differential = heater on or fan engages next stage Offset = heater turns off or fan turns on

Offset Differential Set point Heat off Heat on

Variable Stages Stage 2 cfm Stage 1 Min. Set Point Bandwidth 1 Offset 2 Bandwidth 2 Temperature

Preparing Barns For Winter Cover fans Make sure to disconnect power supply first! Unexpected warmer days may make the fan turn on and burn up the motor when covered. Open baffles if changing from natural or tunnel ventilation to attic/sidewall inlets Clean all inlets Make sure heaters are working and pilot lights are lit

THE END Any Questions Or Comments?