Fireboxes: (NL)FB32C, (NL)FB36C, FB42C, (NL)UV32C, CGFB32C and CGFB36C Series. Stoves: CSDBN, SDVB, MSDVB MSTD, CDV, S39T and S26T Series

Similar documents
GA3650TB Blower Accessory

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

FIREPLACE INSTALLATION

UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION INSTRUCTIONS

DIRECT-VENT FIREPLACE

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

Summer Breeze Heater Service Manual

Installation Instructions

BF5000NT BF5000 EF2604 SF2603 DF2603

DIRECT VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS CD32M-LS AND CD32MB-LS

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Viking Installation Guide

DIRECT-VENT FIREPLACE

User s Manual and Operating Instructions

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

#555 CIRCULATING FAN KIT

Installation Instructions

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS

User s Manual and Operating Instructions

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL. NATURAL GAS TUDOR MODELs (V)T36NA SERIES. PROPANE/LP GAS TUDOR MODELs (V)T36PA SERIES

Over the Range Convection Microwave Oven. Installation Instructions. Model: OTR111SU TINSEB399WRRZ

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

DIRECT-VENT FIREPLACE

PVK-80 Power Vent - Installation Instructions -

Undercounter Refrigeration

Installation Instructions Part No , Part No Part No

Installation Instructions

Installation Instructions

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

READ AND SAVE THESE INSTRUCTIONS

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

CAST IRON STOVE AND B-VENT (FREESTANDING FIREPLACE HEATER) BURNER SYSTEM

IMPORTANT SAFETY INFORMATION

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

SS1095 Ice Maker.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

ELECTRIC STOVE HEATER Models: FS2213B

EF3003 SF3003 DF3003

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Installation Instructions

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

CONSTANT SUCTION UNIT

Ceiling Fan Blade Arm Replacement

WOOD STOVE SERVICE MANUAL

OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

PARTS & SERVICE MANUAL

Installation Instructions

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

ELECTRIC FLAT PANEL FIREPLACE HEATER

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Electric Dryers Instructions 01

ST. KITTS CEILING FAN

CGDV32NR and CTDV32NR-HA

Downdraft Ventilation

Owner s Guide and Installation Manual

Service Manual. Model Number: DF2426 DF2550 DFG2562 BF9000. UL Part Number to

Wall Hanging Mode. Pedestal Mode

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

Water Distiller Service Manual

LENTEK WARRANTY. Directions For Use

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4G ZDP48N6R ZDP48N6D

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

INSTALLATION INSTRUCTIONS

Eldex Column Heater. Operator s Manual

V SERIES HDR GAS RANGES

Installation Instructions

Installation. Built-in Full Height Wine Cellar VCWB301

Service Manual. Model Number: DF2426 DF2550 DFG2562 BF9000. UL Part Number to

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

INSTALLATION INSTRUCTIONS

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

EF5528RKD Freestanding Electric Fireplace

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

CR24 INSTALLATION INSTRUCTIONS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Service Manual 26 Self Trimming Fireplace Model Number: DF2608 DF2622 NBDF2608

Installation Instructions

Transcription:

GA3750A Accessory Installation Instructions For Use With: Fireboxes: (NL)FB32C, (NL)FB36C, FB42C, (NL)UV32C, CGFB32C and CGFB36C Series Vent-Free Fireplaces: VSGF28, VYGF33, VTGF33, VCGF30, VSGF33, FPV33, CGFP28, LFP33 Series and (CG)EFP33 Series Direct-Vent Fireplaces: (E)BDV, BHDV, DVF(E)34, DVFH34, CDV and CHDV Series Stoves: CSDBN, SDVB, MSDVB MSTD, CDV, S39T and S26T Series WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. (Check your appliance owner s manual for specific applications and additional instructions.) Parts included with this kit: Part No. Description Quantity with speed control and 6-foot cord. 1 Instruction Sheet 1 103650-01 Knob 1 103651-01 Lock Nut 1 M11084-38 #8 x 3/8" sheet metal screws 5 101629-01 Plastic Hole Bushings 2 101584-05 Wiring Diagram Decal 1 Tools Required Pliers Phillips driver If any of these pieces are missing or damaged or if the installation instructions for your fireplace or stove are not included in this manual, contact the dealer where you purchased this kit or DESA at 1-866-672-6040 for referral information. Save this manual for future reference. For more information, visit www.desatech.com

Installing Accessory in a 32" Firebox Notice: If a log set is currently installed in the firebox, disconnect log set from gas supply and remove from firebox. Contact a qualified service person to do this. Notice: Not all 24" vent free gas logs can be installed in a 32" firebox with a blower. Please refer to your gas log owner s manual for log sizing requirements. Note: Appearance of firebox may vary slightly depending on model. 1. Remove the firebox bottom: a. Remove the 4 screws that secure the bottom of the firebox (see Figure 1). b. Carefully raise and remove the firebox bottom from the firebox. WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury. 2. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor. 3. Attach green ground wire from power cord to blower housing using screw provided (see Figure 2). Tighten screws securely. 4. Place the blower against lower rear wall of firebox wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 2). Using 2 screws provided, mount blower and tighten screws securely. 5. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight. 6. Locate the plastic hole plug installed in the 3/8" diameter opening in the lower right side of the firebox front panel (see Figure 2). Remove the plastic plug and discard. 7. Place speed control against inner wall of front panel, pushing the plastic control shaft forward through the opening (see Figure 3). 8. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft (see Figure 3). Figure 1 - Removing from Firebox Bottom Exhaust Port Top Mounting Tab Lower Rear Wall of Firebox Wrapper Floor Supports Plastic Hole Plug Figure 2 - Mounting to Firebox Note: Appearance of fireplace may vary by model. Speed Knob Shaft Lock Nut Figure 3 - Attaching Speed 2 www.desatech.com 108319-01D

Installing Accessory in a 32" Firebox 9. Plug in blower power cord. a. If your firebox is installed as a freestanding unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1 /2" hole in the floor support on the exit side. Install the second plastic bushing provided into the 1 1 /2" hole in the outer casing through which the power cord will exit (see Figure 4). Route power cord through both plastic bushings and plug the power cord into a 3-prong grounded wall receptacle near the firebox. b. If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner s manual for instructions on wiring the duplex outlet. CAUTION: Never touch the blower wheel while in operation. 10. Turn on power to duplex outlet if previously turned off per the warning in step 1, page 2. 11. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. 12. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower. 13. Replace bottom of firebox. Note: Make sure the back of the firebox bottom slides under the rear of the firebrick (lift the firebrick up if necessary.) 14. Reattach firebox bottom using 4 screws removed in step 1, page 2. Note: Discard the remaining hardware items. 15. Install the log set heater according to the installation instructions supplied with the heater. operating the blower Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions. INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX NOTICE: If a log set is installed in the firebox, disconnect log set from gas supply and remove from firebox. Contact a qualified service person to do this. Note: Appearance of firebox may vary depending on model. 1. If firebrick is installed, carefully lift and remove the concrete firebrick floor from the firebox (see Figure 5). Some model fireboxes require that you remove the side and rear panels first. Follow the directions below to remove the side and rear firebrick panels for those fireboxes. Plastic Bushing Figure 4 - Installing Plastic Bushing for Power Cord Firebrick Floor Figure 5 - Removing Firebrick Floor from Firebox 108319-01D www.desatech.com 3

INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX a. Using a Phillips screwdriver, remove the screw and retainer bracket at the top of the brick liner panel on the left side. Carefully remove the left panel from the firebox (see Figure 6). b. Repeat the removal steps for the brick liner panel on the right side. c. Remove the screw and retainer bracket at the top of the brick liner panel at the rear of the firebox. IMPORTANT: Do not let panel fall after bracket has bee removed. Carefully remove the rear panel from the firebox (see Figure 7). d. Carefully lift and remove the concrete firebrick floor from the firebox if installed (see Figure 5, page 3). 2. Remove the firebox bottom. a. Remove the 4 screws that secure the bottom of the firebox (see Figure 8). b. Carefully raise and remove the firebox bottom from the firebox. WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with the blower installation. Failure to do this may result in serious injury. Retainer Bracket 3. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor. 4. Attach green ground wire from power cord to blower housing using screw provided (see Figure 9). Tighten screws securely. Retainer Bracket Back Panel Figure 7 - Removing Back Panel from Firebox Figure 8 - Removing Firebox Bottom Exhaust Port Top Mounting Tab Left Panel Figure 6 - Removing Left Panel from Firebox Lower Rear Wall of Firebox Wrapper Figure 9 - Mounting to Firebox 4 www.desatech.com 108319-01D

110/115 V.A.C. White Green Off Variable Fan Switch On White Motor INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX 5. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 9, page 4). Using 2 screws provided, mount blower and tighten screws securely. 6. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight. 7. Locate the plastic hole plug installed in the 3/8" diameter opening in the lower right side of the firebox front panel (see Figure 10). Remove the plastic plug and discard. 8. Place speed control against inner wall of front panel, pushing the plastic control shaft forward through the opening. 9. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft (see Figure 11). 10. Turn on power to duplex outlet if previously turned off per the warning in column 1, page 4. 11. Plug in blower power cord. a. If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1 /2" hole in the floor support on the exit side. Install the second plastic bushing provided into the 1 1 /2" hole in the outer casing through which the power cord will exit (see Figures 10 and 12). Route power cord through both plastic bushings and plug the power cord into a wall receptacle near the firebox. b. If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner s manual for instructions on wiring the duplex outlet. 12. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing. CAUTION: Never touch the blower wheel while in operation. 13. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 12). Plastic Hole Plug 1 1 /2" Hole Plastic Bushing Figure 10 - Installing Plastic Bushing for Power Cord Locknut Speed Shaft Knob Figure 11 - Attaching Speed to Firebox Floor Supports Wiring Diagram Decal 12 in Front of 1 1 /2" Hole Figure 12 - Location of Wiring Diagram Decal 108319-01D www.desatech.com

INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX 14. Replace and reattach firebox bottom using 4 screws removed in step 2 (see Figure 8, page 4). 15. If previously removed, carefully replace the firebrick side panels and/or floor in the firebox (see Figure 5, page 3 and Figures 6 and 7, page 4). 16. Install the log set heater according to the installation instructions supplied with the heater. WARNING: A qualified service person must install heater. Follow all local codes. Note: Discard the remaining hardware items. Operating the Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions. Installing Accessory in Model SVFBC Freestanding Stove Notice: Shut off gas heater during the following blower installation. 1. Remove top panel of stove by removing three screws from under top lip on each side of stove (see Figure 13). 2. Facing front of stove, carefully slide top panel forward until it is completely removed from stove (see Figure 13). 3. Disconnect power cord wires from blower motor (if connected) (see Figure 14). 4. Disconnect green ground wire from blower housing (if connected) by removing screw holding wire terminal (see Figure 14). 5. Install one plastic bushing provided in blower kit into the 1 1 /2" hole in the left rear of firebox floor. Access hole through the rectangular opening in the rear panel (see Figure 15). 6. Remove the two blower mounting brackets from the rear panel by removing two screws each (see Figure 16, page 7). 7. Attach the two mounting brackets to blower housing using four screws provided in blower kit (2 for each bracket) (see Figure 16, page 7). Tighten screws securely. Place blower assembly temporarily on top of firebox. 8. Working from the rear of the stove, place entire power cord, including speed control housing, in lower control compartment. 9. Route ends of 3-wire power cord up from the lower control compartment through the plastic bushing, then up to the upper cavity of stove (see Figure 17, page 7). 10. Attach the terminal ends of the white and black power cord wires to the terminals on the blower motor (see Figure 14). Push firmly. Figure 13 - Removing Stove Top Panel White Powercord Wire Green Ground Wire Figure 14 - Removing Wires from Bushing Powercord Wire Figure 15 - Installing Bushing 6 www.desatech.com 108319-01D

Installing Accessory in Model SVFBC Freestanding Stove 11. Attach the terminal end of the green power cord wire to the front tab of the blower housing using screw provided (see Figure 14, page 6). 12. Using the four screws previously removed, mount blower assembly to stove by reattaching blower brackets to rear panel (see Figure 16). Tighten screws securely. 13. Install plastic control knob onto output shaft of speed control housing (see Figure 17). Place speed control housing just inside control compartment door in front of stove (see Figure 17). 14. Using two screws provided in blower kit, mount blower speed control housing to mounting tab in left side of lower control compartment (see Figure 18). 15. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 16. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 6. 17. Peel off the backing paper and stick the supplied wiring diagram decal on the stove floor as shown in Figure 18. 18. Plug power cord into a convenient 3-prong grounded wall receptacle near the stove. WARNING: Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Bracket Firebox Top Speed Housing Power Cord Knob Figure 16 - Removing Brackets from Stove and Attaching to WARNING: Never attempt to service heater while it is plugged in, operating or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater. If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105 C wire or it s equivalent. Speed Housing Figure 17 - Installing Housing WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 120 Vac. 60 Hz.. 78 Amps 110/115 V.A.C. Green White Variable Fan Switch Wiring Diagram Decal Figure 18 - Routing Power Cord 108319-01D www.desatech.com Off On White DESA Heating Products, Bowling Green, KY Motor

Installing Accessory in Model SVFBC Freestanding Stove 19. Using speed control knob, turn blower on and check for operation. 20. All remaining parts from blower kit may be discarded. Operating the Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Installing Accessory in 32 Fireplace systems Notice: Shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this. Notice: Not all 24" vent free gas logs can be installed in a 32" firebox with a blower. Please refer to your gas log owner s manual for log sizing requirements. Note: Appearance of firebox or burner system may vary depending on model. 1. Remove fireplace screen per the instructions in operation manual supplied with fireplace. 2. If logs are installed, carefully remove the logs and set aside, noting the properly mounted location of each. 3. Remove screws that attach log base assembly to fireplace. Carefully lift up log base assembly and remove from fireplace, taking care to pull flexible gas line through the access holes (see Figure 19). CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates. 4. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor. 5. Attach green ground wire from power cord to blower housing using screw provided (see Figure 18). Tighten screws securely. 6. Place the blower against lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 20). Using 2 screws provided, mount blower and tighten screws securely. 7. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight. 8. Place control knob provided on plastic control shaft of speed control. Green Ground Wire Log Base Flexible Gas Line Figure 19 - Removing Log Base from Fireplace Exhaust Port Top Mounting Tab Lower Rear Wall of Firebox Figure 20 - Mounting to Firebox 8 www.desatech.com 108319-01D

Installing Accessory in 32" Fireplace systems 9. Mount the speed control on the front leg of the left floor support bracket using 2 screws provided (see Figure 21). Note: Some remote ready fireplace models have the gas control located near the left floor support bracket. For these models, mount the blower speed control onto the right floor support bracket. 10. Plug in blower power cord. a. If your fireplace system is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1.5" hole in the floor support bracket on the exit side (see Figure 22). Install the second plastic bushing provided into the 1.5" hole in the outer casing through which the power cord will exit. Route power cord through both plastic bushings and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox. b. If your fireplace system installation is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wiring the duplex outlet. Note: A qualified installer must make all electrical connections. Left Floor Support Bracket 11. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing. CAUTION: Never touch the blower wheel while in operation. 12. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control (Figure 23, page 10). 13. Replace log base assembly in fireplace. Feed flexible gas supply line into fireplace base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Note: If firebrick is installed, make sure the back of the firebox bottom slides under the rear panel of the firebrick (lift the firebrick up if necessary). IMPORTANT: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates. 14. Reattach log base assembly to fireplace with screws removed in step 3, page 8. Note: Discard the remaining hardware items. 15. Install logs and fireplace screen per instructions in operating manual provided with fireplace. WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only parts specifically approved with this heater may result in damage or personal injury. Knob Speed Shaft Figure 21 - Attaching Speed to Firebox Right Floor Support Bracket Plastic Bushing Figure 22 - Installing Plastic Bushing for Power Cord 108319-01D www.desatech.com 9

Installing Accessory in 32" Fireplace systems 16. Connect gas supply to fireplace per instructions in operating manual provided with fireplace. WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. WARNING: Never attempt to service heater while it is plugged in, operating or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater. If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105 C wire or it s equivalent. WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 110/115 V.A.C. Green White 120 Vac. 60 Hz.. 78 Amps DESA, Bowling Green, KY Variable Fan Switch Off On Wiring Diagram White Motor 101584-05 Installing blower accessory IN freestanding stove series SDV, MSD, MSTD, CDV OR CSDBN IMPORTANT: Read all installation instructions before installing blower. NOTICE: Shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this. Installing the 1. Remove 4 hex bolts securing rear cover to back of stove body (see Figure 24). 2. Separate bottom cover from rear cover by loosening the 8 mounting screws (see Figure 24). 3. Align the holes in the top mounting tabs of blower with the holes in wall of rear cover (see Figure 25, page 11). Using the 4 screws provided, mount blower and tighten screws securely. 4. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor. 5. Attach green ground wire from power cord to blower housing using screw provided (see Figure 25, page 11). Tighten screw securely. 6. Make sure all wire connections to terminals on blower motor are securely attached and that the screw retaining the green ground wire is tight. Rear Cover Figure 23 - Location of Wiring Diagram Decal 3" from Operating the Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions. (Note: Stove Body May Vary by Model) Figure 24 - Removing/Installing Rear Cover 10 www.desatech.com 108319-01D

Installing blower accessory IN freestanding stove series SDV, MSD, MSTD, CDV OR CSDBN 7. Place speed control on left inside of rear cover and push the plastic control shaft through opening (see Figure 25). 8. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the side of rear cover. Place control knob provided onto shaft (see Figure 25). 9. Plug in blower power cord. 10. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing. CAUTION: Never touch the blower wheel while in operation. 11. Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover as shown (see Figure 25). 12. Connect or reconnect gas supply following instructions given in the owner s manual supplied with your fireplace. WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. 13. Reattach bottom cover to rear cover with 8 screws (see Figure 25). Make sure that you don t pinch any wires during reassembly. 14. Secure rear cover to back of stove chassis (see Figure 25). 15. Plug in the power cord when ready to use. WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only parts specifically approved with this heater may result in damage or personal injury. Knob Lock Nut Assembly Shaft Green Ground Wire Speed Rear Cover Power Cord Mounting (Included in Hardware Pack) Wiring Diagram Decal Exhaust Port Figure 25 - Installing Optional Accessory Operating the Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air through the openings in the top of the stove body. The blower features a variable control which allows you to select the speed you desire. The blower helps distribute heated air from the fireplace. Periodically check the openings of the stove top and remove any dust, dirt or other obstructions that will hinder the flow of air. 108319-01D www.desatech.com 11

Installing blower accessory in directvent FIREPLACE series bhdv, (E)bdv, ddv, hdv, CDV, CHDV, DVF(E) or DVFH IMPORTANT: Read all installation instructions before installing blower. NOTICE: Shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this. IMPORTANT: For clarity, gas valve assembly and grate/burner assembly are not shown in Figures 24 and 25. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines. 1. Open lower louver panel as shown in Figure 26. 2. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor. Lower Rear Wall of Firebox Wrapper Assembly Exhaust Port Green Ground Wire Lower Louver Panel Figure 26 - Mounting to Firebox 3. Attach green ground wire from power cord to blower housing using screw provided (see Figure 26). Tighten screw securely. 4. Place the blower under the firebox and against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Figure 26). Using the two screws provided, mount blower and tighten screws securely. 5. Be sure all wire terminals on blower are attached securely. Make sure the screw retaining the green wire is tight. 6. Remove screws securing the plate containing the ON/OFF switch to the bottom of the firebox and set aside. 7. Place speed control against the back of this plate and push the plastic control shaft through opening (see Figure 27). 8. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the plate. Place control knob (provided) onto shaft (see Figure 27). 9. Replace plate containing switches and tighten screws securely. 10. Plug in blower power cord. a. If your fireplace system is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install one plastic bushing (provided) into the 1 1 /2" hole in the outer casing through which the power cord will exit. Install the second plastic bushing (provided) into the floor support bracket if exiting through the right side (see Figure 28, page 14). Route power cord through (both) plastic bushing(s) and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox. Shaft Knob Speed Locknut Switch Plate Figure 27 - Attaching Speed to Firebox 12 www.desatech.com 108319-01D

Installing blower accessory in directvent FIREPLACE series bhdv, (E)bdv, ddv, hdv, CDV, CHDV, DVF(E) or DVFH b. If your fireplace system installation is recessed and/or pre-wired, a qualified installer must make all electrical connections for the outlet kit included with the fireplace. 11. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing. Wiring Diagram Decal Plastic Bushing CAUTION: Never touch the blower wheel while in operation. 12. Peel off the backing paper and stick the supplied wiring diagram decal on the outer casing bottom approximately 3" to the right of the blower speed control (Figure 28). Figure 28 - Installing Plastic Bushing for Power Cord and Locating Wiring Diagram Decal WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only parts specifically approved with this heater may result in damage or personal injury. 13. Connect or reconnect gas supply following instructions given in the owner s manual supplied with your fireplace. WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. 108319-01D www.desatech.com 13

NOTES 14 www.desatech.com 108319-01D

NOTES 108319-01D www.desatech.com 15

2701 Industrial Drive, P.O. Box 90004 Bowling Green, KY 42102-9004 Technical Service Department 1-866-672-6040 www.desatech.com 108319 01 NOT A UPC 108319-01 Rev. D 01/06