DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

Similar documents
ELITE Series Variable Capacity

ELITE Series Variable Capacity

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

14 AC x

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A - Two-Stage Compressor

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

2 shp 13 lc 1 36 t - 1 a

T S A 048 S 4 N 4 1 T

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

T P A 120 S 4 S N 1 Y

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

T P A 048 S 4 N 4 1 T

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Visit us at For the latest technical information,

MERIT SERIES Up Flow / Horizontal

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

CB X 32 mv

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TECHNICAL SPECIFICATIONS

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

13 GEP A L P - 1 A

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

The XP21 raises the bar for efficiency and comfort.

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

An air conditioner that redefines comfort and efficiency.

C22FC Bulletin # October 1993 Supersedes May 1993

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

The XC21 delivers the ultimate in comfort.

cool and comfortable Air Conditioners

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

complete comfort Heat Pumps

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

RGE 13 A T - 1 A

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Ruud Achiever Series Air Conditioners

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

XP21 The most quiet and efficient heat pump you can buy*

Commercial High-Efficiency Condensing Units

C22 Bulletin # October 1993 Supersedes May 1993

A heat pump that redefines comfort and efficiency.

Lennox 8 Series Single Zone - R-410A

complete comfort Heat Pumps

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

The XC17 is an efficiency expert.

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

PAJ3. Product Specifications

TECHNICAL SPECIFICATIONS

complete comfort Heat Pumps

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Commercial High-Efficiency Condensing Units

The XP17 provides comfort without comparison.

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data. Fig. 1 - Unit 50VR -A

Transcription:

PRODUCT SPECIFICATIONS AIR CONDITIONERS XC25 DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology Bulletin No. 210658 November 2017 Supersedes August 2017 * icomfort S30 Thermostat SEER up to 26.00 2 to 5 Tons Cooling Capacity - 22,000 to 59,500 Btuh MODEL NUMBER IDENTIFICATION x c 25-036 - 230-1 Refrigerant Type X = R-410A Unit Type C = Air Conditioner Minor Revision Number Voltage 230 = 208/230V-1ph-60hz Series Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons * icomfort Communicating Thermostat required. Not furnished - Order separately.

FEATURES B CONTENTS AHRI System Matches... 15 Dimensions... 13 Electrical Data... 11 Features... 2 Field Wiring... 12 Installation Clearances... 12 Model Number Identification... 1 Optional Accessories... 11 Sound Data... 12 Specifications... 11 Sunsource Home Energy System - Components... 7 D C K J E I M L G H F WARRANTY Compressor - Ten year limited warranty in residential installations and five years in non-residential installations. All other covered components - Ten years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 210/240-2008 Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by ETL, NEC, and CEC. Units are ETL certified for the U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. For expanded ratings, see www.lennoxpros.com. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. XC25-2 to 5 Ton Air Conditioner / Page 2 APPLICATIONS SEER up to 26.00. 2 through 5 ton. Single phase power supply. Sound levels as low as 59 db. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers tab sections for data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job. NOTE - The XC25 can only be matched with icomfort Communicating variable-speed indoor furnaces and air handlers.

B A C D E F FEATURES REFRIGERATION SYSTEM R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table. Outdoor Coil Fan with SilentComfort Technology Specially-designed, SilentComfort fan guard uses Passive Vortex Suppression to reduce air noise. Constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. Specially designed fan blades reduce operating sound levels. Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan service access accomplished by removal of fan guard. Variable-Speed Outdoor Coil Fan Motor With Integrated Control Outdoor coil fan motor with integrated control is programmed for variable capacity operation. Fan speed is directly controlled by the icomfort communications between the outdoor unit icomfort Communicating control and the icomfort Communicating thermostat. Fan motor is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. G H Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. Hi-Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular-sieve bead type drier. Optional Accessories Expansion Valve Kits Must be ordered separately and field installed on certain indoor units. See TXV Usage table on page 14. Chatleff style fitting. Freezestat Installs on or near the discharge line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Recommended for extra protection during low ambient operation. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory. Suction line fully insulated. L15 lines are stubbed at both ends. See Specifications table for selection. Not available for -060 model and must be field fabricated. NOTE - The XC25 is a variable capacity air conditioner utilizing variable speed compressor technology. With the variable speed compressor and variable pumping capacity, additional consideration must be given to refrigerant piping sizing and application. Please refer to the Installation Instructions or Service Literature for Line Set Requirements and Refrigerant Piping Guidelines. XC25-2 to 5 Ton Air Conditioner / Page 3

I FEATURES PRECISE COMFORT TECHNOLOGY The Variable Capacity Compressor and DC Inverter Control is an integrated system that operates together to reduce overall energy usage when compared to conventional air conditioners. Variable Capacity Scroll Compressor Operates on a variable frequency determined by the DC Inverter Control to vary capacity based on the cooling load required. Features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. J DC Inverter Control Converts AC line voltage into filtered variable DC voltage. Provides continuous compressor operation, while adjusting the capacity according to indoor temperature. Adjusts compressor output in increments as small as 1%. The accurate sensing of cooling load prevents frequent changes in capacity and ensures efficient, economical operation. Power Factor Correction (PFC) circuit monitors the DC bus for high, low and abnormal voltage conditions to protect the compressor. Two LEDS (red and green) indicate inverter operating status and aid in troubleshooting. Noise filter reduces unwanted electromagnetic interference (EMI). Integrated on the control for 024 and 036 models, external to the control for 048 and 060 models. The inverter reactor (mounted separately) adds inductance to the line between the inverter and the compressor to limit current rise and protect the compressor. Top Cap Thermal Sensor Switch Located on top of the compressor casing. Discontinues compressor operation in case of abnormal operating conditions. Compressor Sound Dampening System A polyethylene compressor cover containing a 2 inch thick batt of fiberglass insulation for better sound dampening. All open edges are sealed with a one-inch wide hook and loop fastening tape. Crankcase Heater Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. XC25-2 to 5 Ton Air Conditioner / Page 4

K FEATURES CONTROLS icomfort Communicating Control Advanced control communicates information about various operating parameters in the air conditioner to the icomfort Communicating Thermostat to constantly maintain the highest level of comfort, performance and efficiency available. Auto Configuration - On start-up the control automatically sends a description of the unit to the icomfort Communicating Thermostat to automatically configure the features available. Control also features: Seven-Segment Display shows information about outdoor unit type and capacity and also displays alerts for common fault conditions (electrical and mechanical). Low voltage protection prevents compressor operation when voltage is not within the specified range. High and low pressure switch monitoring with provisions for lockout. Five-Strike lockout protection protects compressor. Liquid line temperature and sensor monitoring. EEPROM storage of all local configurations. Non-volatile memory storage of 100 alarm codes with display of last 10 codes for troubleshooting. Built-in low ambient control. Low Ambient Operation The air conditioner can operate down to 0 F outdoor air temperature. NOTE - A freezestat is recommended for extra protection during low ambient operation. Climate IQ Technology Optimizes dehumidification settings for specific climates to improve home comfort during cooling operation. icomfort Wi-Fi Thermostat Settings: Dry - The system supplies higher indoor airflow at all compressor capacities, increasing efficiency by operating at a higher sensible to total ratio. Moderate - The system supplies indoor airflow that balances efficiency and comfort. Humid - The system supplies lower indoor airflow at all compressor capacities, improving humidity removal by operating at a lower sensible to total ratio. icomfort S30 Thermostat Setting: Climate IQ (Auto) - Dry, Normal, Basic and Humid modes are automatically set based on the difference between the measured relative humidity and the relative humidity setting. All modes are selected on the icomfort Communicating Thermostat. Outdoor Air Temperature Sensor Used with icomfort Communicating Thermostats. Sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. Sensor is auto-detected when connected to thermostat. REQUIRED COMPONENTS NOTE - The XC25 Air Conditioner can only be used with an icomfort Communicating Thermostat. icomfort S30 Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S30 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. Dealer Dashboard features online real-time monitoring of installed icomfort systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7 in. high definition color display (measured diagonally). Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring. Remote outdoor temperature sensor (furnished with outdoor unit) allows the thermostat to display outdoor temperature. High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S30 Thermostat Product Specifications bulletin in the Controls section for more information. XC25-2 to 5 Ton Air Conditioner / Page 5

FEATURES REQUIRED COMPONENTS (continued) icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. Dealer Dashboard features online real-time monitoring of installed icomfort systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring. Remote outdoor temperature sensor (furnished with outdoor unit) allows the thermostat to display outdoor temperature. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. L M CABINET Heavy-gauge steel construction Pre-painted cabinet finish. Compressor and control box located in a separate compartment, insulated with thick fiberglass insulation. Compartment provides protection from the weather and keeps sound transmission at a minimum. Control box is conveniently located with all controls factory wired. Large removable panel provides service access. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture. PermaGuard Unit Base Durable zinc-coated base section resists rust and corrosion. SmartHinge Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Suction and liquid line service valves and gauge ports are located inside the cabinet. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. XC25-2 to 5 Ton Air Conditioner / Page 6

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS Solar Modules Future Modules Standard Outlet Communication Gateway Broadband Internet Connection Performance Monitoring Website Air Conditioner or Heat Pump Unit SYSTEM OVERVIEW All Dave Lennox Signature Collection air conditioners and heat pumps are equipped at the factory for upgrading to the SunSource Home Energy System. Units can be upgraded at the time of installation or in the future. Solar energy is first used to meet cooling/heating demands. When the cooling/heating system is not operating, the system powers lighting, appliances and other electronic devices in the home. And in some locations, any surplus power is sent back to the utility company for a possible credit (check with your local utility company for availability). The SunSource system consists of the following components: Lennox Solar Sub-Panel field installed in a Dave Lennox Signature Collection air conditioner or heat pump unit. SolarWorld Pre-Engineered Kits consisting of: SolarWorld Solar Modules (1 to 16 may be used to vary the amount of electricity generated). Enphase Microinverter that converts Direct Current to Alternating Current. Enphase Envoy Communications Gateway for solar power performance monitoring. Roof Mounting Components Electrical Panel Wiring from the roof mounted solar modules is routed to the outdoor unit. From there power travels to the home electrical service panel using the existing outdoor unit power wiring. NOTE - Refer to separate Product Specifications Bulletin for the SunSource Home Energy System for more detailed information. See section Solar - Kits/ Accessories. Also refer to SunSource Home Energy System Applications and Design Guidelines Manual (Corp. 1312-L2) for complete information on designing, sizing and installing a complete system. APPROVALS The SunSource Home Energy System meets the requirements for federal tax credit eligibilty listed under the U.S. Emergency Economic Stabilization Act of 2008, covering 30% of the cost of the solar modules, including installation. LENNOX SOLAR SUB-PANEL The Lennox Solar Sub-Panel replaces the factory piping panel on the outdoor unit and provides circuit breaker protection and power entry for both HVAC (line) and solar power wiring. Sub-Panel is equipped with separate circuit breakers for both HVAC (line) voltage and solar power. Equipped with pigtail connections for easy field wiring. Sub-Panel is an ETL listed accessory. Split design (upper/lower panel) allows installation on different size outdoor units. Sub-Panel is furnished with three separate lower panels. See Outdoor Unit Usage table for correct lower panel size. NOTE - Sub-Panel is not backwards compatible with older non Solar-Ready Dave Lennox Signature Collection outdoor units. Disconnects for HVAC (line) and solar power wiring are not furnished and must be field provided. XC25-2 to 5 Ton Air Conditioner / Page 7

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS SOLAR MODULE Captures solar energy to convert into AC power through the Enphase Microinverter. Laminated solar module structure consists of the solar glass, two ethylene vinyl acetate (EVA) sheets, the solar cell matrix and a back sheet. Thick low-iron safety glass withstands extreme weather conditions and heavy snow loads. Solar modules are ETL/Intertek listed for the US and Canada to UL Standard 1703 and meet National and Canadian Electrical Code requirements. Solar Module Frame Available in black or clear anodized silver frame with cast aluminum corner keys. Low profile with extended flange. Compatible with top-down and bottom-up mounting methods. Eight grounding locations (Four corners of the frame and four locations along the length of the module in the extended flange). Extended cable lengths for easier installation. ENPHASE MICROINVERTER Converts Direct Current (DC), captured by a solar module, to Alternating Current (AC) power. Each solar module is paired with one Enphase Microinverter. Installed beneath each solar module on the roof. Enphase Microinverters operate independently from each other allowing solar modules that are not shaded or dirty to operate with optimum performance. Supports low-light and low-voltage operation. SYSTEM MONITORING Enphase Envoy Communications Gateway (Communications Booster Furnished) The Enphase Envoy Communications Gateway monitors microinverter (on solar modules) performance and can be connected to a broadband internet connection to send data to the Enphase Enlighten web site for online monitoring by the homeowner. The Enphase Envoy Communications Gateway is not required, but must be used if system performance monitoring is desired. Limited system monitoring is also available locally with the Enphase Envoy Communications Gateway and a personal computer if no internet connection is available. Various Event Messages are also available when monitoring the system via a personal computer locally. Contents - (1) Enphase Envoy Communications Gateway, (1) Communications Booster, (1) 6 ft. power cord, (1) 10 ft. Ethernet cable, communications booster. CSA (US/C) listed. The Enphase Envoy Communications Gateway includes a Communications Booster which may or may not be needed depending upon how far the Envoy is away from the solar modules. Communications Booster Ethernet bridge signal booster for the Enphase Envoy Communications Gateway. Booster is only needed if the communications gateway is installed and signal is not strong enough in the installed location. Allows the unit to be plugged into an outlet closer to the distribution panel, yet still plug into the broadband router. Enphase Enlighten Performance Monitoring Website Powered by the Enphase Envoy Communications Gateway, the Enphase Enlighten Performance Monitoring website allows the homeowner to keep track of home energy usage and see environmental benefits in real time. Also aids in troubleshooting any solar-related issues. See demos, view reference installations and other additional information at: http://enlighten.enphaseenergy.com/ XC25-2 to 5 Ton Air Conditioner / Page 8

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS ROOF MOUNTING COMPONENTS D C E G I B H F B C D E F G H I Rails - Provides a mounting surface for Solar Modules in portrait orientation using associated hardware. Serrations on sides of rails provide a secure and stable mating surface for hardware (L-Brackets, Rail Splice Ground Jumper, Ground Lug). Available in 122 in. (3099 mm) and 162 in. (4115 mm) lengths. Rail Splice Bar Connector - For connecting two lengths of rail together. No fasteners required. Pin on center of splice leaves a gap between rails to allow for thermal expansion. Top Clamp Assembly (Silver or Black) - M8 T40 bolt with channel nut, bolt positioning retainer and serrated module clamping washer. Inserts into rail slot to secure modules and set spacing in-between each one. End Clamp Aluminum Spacer (Silver or Black) - Used with Top Clamp Assembly for securing the end of module mounting row. Composition Roof Mount/Flashing (Mil Aluminum or Bronze) - Provides roof mounting surface for mounting system. Size - 12 x 12 in. (305 x 305 mm). Base block, hanger bolt and hardware furnished. Adds 1-1/4 in. (32 mm) height below the L-Bracket. L-Bracket - Clear anodized aluminum with serrated mating surface. Fastens rail to Roof Mount/Flashing. Has two 1 in. (25 mm) slots that provide adjustment from 2-1/2 to 3-1/2 in. (64 to 89 mm). Wire Clip (not shown) - Provides wire management for solar array wiring. Fastens to edge of rail. For 10 AWG. Ground Lug (not shown) - Tin plated, WEEB 8.0, layin type. Mounts to corner of solar module. Rail-Equipment Ground WEEB 8.0 Lug - T-bolt slides into rail for secure connection. Rail Splice Ground Jumper - WEEB 8.0, preassembled with T-bolts. Electrically bonds rails together. Required at each rail splice. Rooftop Junction Box (not shown) - Soladeck JBox with flashing. Used to transition from the AC- Interconnection cable to wiring/conduit to the outdoor unit. ETL-listed weather-tight enclosure. Passthru Kit (not shown) - Used with Rooftop Junction Box. One-branch AC passthru kits. Contains all necessary wiring hardware. ENPHASE ENGAGE CABLE COMPONENTS Enphase Engage Cable - The Engage Cable (shown with connector) is a 12 AWG cable with pre-installed connectors (portrait aligned) that plug into the Microinverter. Four wire cable (240V single-phase). Enphase Engage Cable Terminator - Each Engage Cable is terminated at a junction or combiner box. The opposite end of the cable must be terminated with an Engage Cable Terminator cap. Enphase Engage Disconnect Tool - Specialized tool that disconnects the Engage Cable from a Microinverter or watertight sealing cap. Enphase Engage Water-tight Sealing Cap - Use when open connections on the Engage Cable are not mated to a Microinverter. ENPHASE MICROINVERTER MOUNTING L-Bracket and associated hardware to mount microinverter to rail. XC25-2 to 5 Ton Air Conditioner / Page 9

SUNSOURCE - PRE-ENGINEERED KITS ORDERING SunSource Pre-Engineered Kits are available for composition shingle roofs, standing seam roofs, trapezoid metal roofs, flat tile roofs and S tile roofs. See the Sunsource Home Energy System Product Specifications bulletin for complete Pre-Engineered Kits ordering instructions and the Ordering Process Flowchart/Worksheet. The Installation Package contains the appropriate number of required Rails, Splices, Brackets, Clamps, Clips and assorted hardware (nuts/bolts/washers) for the installation. NOTE The Lennox Solar Sub-Panel for the outdoor unit must be ordered separately. See below for ordering information. Lennox Solar Sub-Panel Order one per outdoor unit. Replaces the outdoor unit piping panel and provides the connection between the solar modules and outdoor unit. 62E02 LENNOX SOLAR SUB-PANEL - OUTDOOR UNIT USAGE Outdoor Unit Model No. Lower Sub-Panel Height - in. (mm) 27 (686) XC25 (all aizes) X XC25-2 to 5 Ton Air Conditioner / Page 10

SPECIFICATIONS General Data Connections (sweat) Model No. XC25-024 XC25-036 XC25-048 XC25-060 Nominal Tonnage 2 3 4 5 Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 Suction line (o.d.) - in. 7/8 7/8 7/8 1-1/8 Refrigerant 1 R-410A charge furnished 13 lbs. 10 oz. 10 lbs. 12 oz. 14 lbs. 8 oz. 12 lbs. 9 oz. Outdoor Coil Outdoor Fan Net face area - sq. ft. Outer coil 27.21 27.21 27.21 27.21 Inner coil 26.36 26.36 26.36 26.36 Tube diameter - in. 5/16 5/16 5/16 5/16 No. of rows 2 2 2 2 Fins per inch 22 22 22 22 Diameter - in. 26 26 26 26 No. of blades 5 5 5 5 Motor hp 1/3 1/3 1/3 1/3 Cfm - Max. Speed 2925 4100 4220 4385 Min. Speed 1950 1950 3020 3020 Rpm - Max. Speed 490 650 675 700 Min. Speed 350 350 500 500 Watts - Max. Speed 75 157 185 212 Min. Speed 32 32 82 82 Shipping Data - lbs. - 1 pkg. 303 303 330 330 ELECTRICAL DATA Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 2 Maximum overcurrent protection (amps) 25 30 50 50 3 Minimum circuit ampacity 14.9 19.5 32.9 34.1 Compressor Rated load amps 10.3 14.0 24.7 25.7 Locked rotor amps 18 18 29 29 Power factor 0.97 0.98 0.99 0.99 Outdoor Fan Motor - Full load amps 2.0 2.0 2.0 2.0 REQUIRED COMPONENTS - ORDER SEPARATELY icomfort S30 Thermostat 12U67 icomfort Wi-Fi Thermostat 10F81 4 Discharge Air Temperature Sensor 88K38 OPTIONAL ACCESSORIES - ORDER SEPARATELY 5 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 6 Refrigerant Line Sets L15-65-30 L15-65-40 L15-65-50 Field Fabricate NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Used with the icomfort Communicating Thermostats for optional service diagnostics. 5 Freezestat is recommended for low ambient operation. 6 Refer to the Installation Instructions or Service Literature for Line Set Requirements and Refrigerant Piping Guidelines. XC25-2 to 5 Ton Air Conditioner / Page 11

SOUND DATA Unit Model Octave Band Linear Sound Power Levels db, re 10-12 Watts - Center Frequency - Hz Operation 125 250 500 1000 2000 4000 8000 1 Sound Rating Number (SRN) (dba) 024 036 048 060 Min. 49.0 49.0 46.3 45.1 38.2 37.7 33.8 59 Max. 54.0 56.3 56.9 53.4 46.7 45.2 37.4 70 Min. 48.1 50.4 50.6 43.1 34.9 33.9 30.5 59 Max. 58.0 62.5 63.8 60.4 54.2 48.7 41.8 73 Min. 52.2 55.8 57.2 52.2 45.5 39.3 39.1 66 Max. 58.5 62.2 65.0 61.5 55.3 49.8 43.1 74 Min. 54.1 55.1 54.5 51.1 44.4 38.6 38.0 64 Max. 58.9 61.9 64.3 61.1 55.2 49.0 42.6 74 1 Sound Rating Number according to ANSI/AHRI Standard 270-2008. SRN is the overall A-Weighted Sound Power Level, (LWA), db (100 Hz to 10,000 Hz). INSTALLATION CLEARANCES - INCHES (MM) NOTES - One of these three sides must be 36 in. (914 mm). One of the two remaining sides may be 12 in. (305 mm). The remaining side may be 6 in. (152 mm). Service Clearance 30 in. (762 mm) See Notes See Notes Service See Notes 48 in. (1219 mm) clearance required on top of unit 24 in. (610 mm) required between two units See Notes FIELD WIRING DISCONNECT SWITCH (By Others) B LENNOX AIR CONDITIONER ICOMFORT COMMUNICATING THERMOSTAT (REQUIRED) C D DISCONNECT SWITCH (By Others) A LENNOX HEATING UNIT OR AIR HANDLER UNIT A - Two Wire Power (not furnished) B - Two Power (not furnished) See Electrical Data C - Four Wire Low Voltage RSBus (not furnished) 18 ga. minimum D - Four Wire Low Voltage RSBus (not furnished) 18 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. XC25-2 to 5 Ton Air Conditioner / Page 12

DIMENSIONS - INCHES (MM) UNIT SUPPORT FEET 16-7/8 (429) 26-7/8 (683) 8-3/4 (222) 3-3/4 (95) TOP VIEW 3-1/8 (79) 30-3/4 (781) TOP VIEW BASE SECTION (Large Base) 4-5/8 (117) 39-1/2 (1003) 35-1/2 (902) DISCHARGE AIR HIGH VOLTAGE ELECTRICAL INLET (024, 036) SUCTION LINE INLET 47 (1194) 4-1/2 (114) HIGH VOLTAGE ELECTRICAL INLET (048, 060) LIQUID LINE INLET 18-1/2 (470) LOW VOLTAGE ELECTRICAL INLET 8 (203) 1 (25) SIDE VIEW ACCESS VIEW XC25-2 to 5 Ton Air Conditioner / Page 13

TXV USAGE Use this table for C33, C35, CH23, CH33, CH35 and CR33 Field Installed TXV Match-Ups. Outdoor Unit Model No. XC25-024 XC25-036 XC25-048 XC25-060 Order No. 12J18 12J19 12J20 12J20 CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. C33, C35, CH33 and CH35 coils - Factory installed orifice must be replaced with the expansion valve listed. CR33 and CH23 coils - Use the expansion valve listed. MOST POPULAR MATCHES Outdoor Unit Model No. XC25-024 XC25-036 XC25-048 XC25-060 Indoor Unit Model No CBX40UHV-024 CBX40UHV-036 CBX40UHV-048 CBX40UHV-060 AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. XC25-2 to 5 Ton Air Conditioner / Page 14

AHRI SYSTEM MATCHES NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or Capacity SEER EER Furnace No. Device Air Handler AHRI Reference XC25-024-230 TXV 22400 25 16 C35-30/36C SLP98UH090XV36C 8248284 XC25-024-230 TXV 23000 25 16.5 C35-30A SL280UH070XV36A 8248280 XC25-024-230 TXV 22800 25 16 C35-30B EL296UH045XV36B 8248281 XC25-024-230 TXV 22800 25.5 16 C35-30B EL296UH070XV36B 8248282 XC25-024-230 TXV 23000 25 16.5 C35-30B SL280UH090V36B 8248056 XC25-024-230 TXV 22800 25.5 16 C35-30B SLP98UH070XV36B 8248283 XC25-024-230 TXV 23000 24.5 16 C35-36A SL280UH070V36A 8248057 XC25-024-230 TXV 23000 24.5 16 C35-36B EL296UH045XV36B 8248285 XC25-024-230 TXV 23000 25.5 16 C35-36B EL296UH070XV36B 8248058 XC25-024-230 TXV 23200 25.5 16.5 C35-36B SL280UH090V36B 8248286 XC25-024-230 TXV 23000 25.5 16 C35-36B SLP98UH070XV36B 8248059 XC25-024-230 TXV 22800 24.5 16 CBX32MV-024/030 7042645 XC25-024-230 TXV 23000 25.5 16.5 CBX32MV-036 7042646 XC25-024-230 TXV 23000 26 16.5 CBX40UHV-024 7042643 XC25-024-230 TXV 23000 25 16.5 CBX40UHV-030 7042644 XC25-024-230 TXV 22400 23.5 15.5 CH23-51 EL296UH045XV36B 7042727 XC25-024-230 TXV 22400 24 15.5 CH23-51 EL296UH070XV36B 7042728 XC25-024-230 TXV 22400 24 16 CH23-51 SL280UH070V36A 7042729 XC25-024-230 TXV 22400 24.5 16 CH23-51 SL280UH090V36B 7042730 XC25-024-230 TXV 22400 24 15.5 CH23-51 SLP98UH070XV36B 7042731 XC25-024-230 TXV 22000 24.5 15.5 CH33-19 SL280UH070XV36A 7042734 XC25-024-230 TXV 23000 25 16 CH33-31B EL296UH045XV36B 7042688 XC25-024-230 TXV 23000 25.5 16 CH33-31B EL296UH070XV36B 7042689 XC25-024-230 TXV 23000 25 16.5 CH33-31B SL280UH070V36A 9063066 XC25-024-230 TXV 23200 26 16.5 CH33-31B SL280UH090V36B 7042690 XC25-024-230 TXV 23000 25.5 16 CH33-31B SLP98UH070XV36B 7042691 XC25-024-230 TXV 22800 24 16 CH33-42B EL296UH045XV36B 7042692 XC25-024-230 TXV 22800 24.5 16 CH33-42B EL296UH070XV36B 7042693 XC25-024-230 TXV 23000 25 16.5 CH33-42B SL280UH090V36B 7042694 XC25-024-230 TXV 22800 24.5 16 CH33-42B SLP98UH070XV36B 7042695 XC25-024-230 TXV 23200 26 16.5 CH33-43C EL296UH090XV36C 7042696 XC25-024-230 TXV 23200 26 16.5 CH33-43C SLP98UH090XV36C 7042697 XC25-024-230 TXV 23000 25 16.5 CH35-30A SL280UH070V36A 10041106 XC25-024-230 TXV 23000 25 16 CH35-30B EL296UH045XV36B 7295826 XC25-024-230 TXV 23000 25.5 16 CH35-30B EL296UH070XV36B 7295828 XC25-024-230 TXV 23200 26 16.5 CH35-30B SL280UH090V36B 7295830 XC25-024-230 TXV 23000 26 16 CH35-30B SLP98UH070XV36B 7295831 XC25-024-230 TXV 23000 25 16.5 CH35-42B SL280UH090V36B 10259353 XC25-024-230 TXV 22800 24 16 CR33-30/36B SLP98DF070XV36B 9829646 XC25-024-230 TXV 22800 24 16 CR33-48B EL296DF045XV36B 7042683 XC25-024-230 TXV 22800 23 15.5 CR33-48B EL296DF070XV48B 7042684 XC25-024-230 TXV 22800 23.5 16 CR33-48B SL280DF090V48B 7042685 XC25-024-230 TXV 22800 24 16 CR33-48B SLP98DF070XV36B 7042686 XC25-024-230 TXV 23000 24 16 CR33-48C SLP98DF090XV36C 7042687 XC25-024-230 TXV 22400 25 16 CX35-30/36C SLP98UH090XV36C 8248292 XC25-024-230 TXV 23000 25 16.5 CX35-30A SL280UH070V36A 10230594 XC25-024-230 TXV 23000 25 16.5 CX35-30A SL280UH070XV36A 8248287 XC25-024-230 TXV 22800 25 16 CX35-30B EL296UH045XV36B 8248288 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air.all ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. XC25-2 to 5 Ton Air Conditioner / Page 15

AHRI SYSTEM MATCHES NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or Capacity SEER EER Furnace No. Device Air Handler XC25-2 to 5 Ton Air Conditioner / Page 16 AHRI Reference XC25-024-230 TXV 22800 25.5 16 CX35-30B EL296UH070XV36B 8248289 XC25-024-230 TXV 23000 25 16.5 CX35-30B SL280UH090V36B 8248290 XC25-024-230 TXV 22800 25.5 16 CX35-30B SLP98UH070XV36B 8248291 XC25-024-230 TXV 23000 24.5 16 CX35-36A SL280UH070V36A 8248060 XC25-024-230 TXV 23000 24.5 16 CX35-36B EL296UH045XV36B 8248293 XC25-024-230 TXV 23000 25.5 16 CX35-36B EL296UH070XV36B 8248294 XC25-024-230 TXV 23200 25.5 16.5 CX35-36B SL280UH090V36B 8248295 XC25-024-230 TXV 23000 25.5 16 CX35-36B SLP98UH070XV36B 8248061 XC25-036-230 TXV 34000 22 13 C35-30/36B SLP98UH070XV36B 8248296 XC25-036-230 TXV 34200 22.5 13.5 C35-30/36C SLP98UH090XV36C 8248297 XC25-036-230 TXV 35400 22.5 14 C35-36A SL280UH070V36A 8248247 XC25-036-230 TXV 35200 22.5 13.5 C35-36B EL296UH045XV36B 8248298 XC25-036-230 TXV 35400 23 14 C35-36B EL296UH070XV36B 8248248 XC25-036-230 TXV 35600 23.5 14.5 C35-36B SL280UH090V36B 8248043 XC25-036-230 TXV 35600 22.5 14.5 C35-36B SL280UH090V48B 8248044 XC25-036-230 TXV 35400 23 14 C35-36B SLP98UH070XV36B 8248249 XC25-036-230 TXV 35400 22.5 14 C35-48B EL296UH045XV36B 8248250 XC25-036-230 TXV 35600 23 14 C35-48B EL296UH070XV36B 8248251 XC25-036-230 TXV 35800 23 14.5 C35-48B SL280UH090V36B 8248045 XC25-036-230 TXV 35600 22.5 14.5 C35-48B SL280UH090V48B 8248046 XC25-036-230 TXV 35600 23 14 C35-48B SLP98UH070XV36B 8248047 XC25-036-230 TXV 35600 23.5 14.5 C35-48C EL296UH090XV36C 8248252 XC25-036-230 TXV 35800 23 14.5 C35-48C EL296UH090XV48C 8248048 XC25-036-230 TXV 35600 23.5 14.5 C35-48C SLP98UH090XV36C 8248253 XC25-036-230 TXV 35800 23 14.5 C35-48C SLP98UH090XV48C 8248254 XC25-036-230 TXV 35800 23 14.5 C35-49C EL296UH090XV36C 8248255 XC25-036-230 TXV 35800 22.5 14.5 C35-49C EL296UH090XV48C 8248256 XC25-036-230 TXV 35800 23 14.5 C35-49C SLP98UH090XV36C 8248257 XC25-036-230 TXV 35800 22.5 14.5 C35-49C SLP98UH090XV48C 8248258 XC25-036-230 TXV 35400 22.5 14.5 C35-50/60C EL296UH090XV36C 8248259 XC25-036-230 TXV 35600 22.5 14.5 C35-50/60C EL296UH090XV48C 8248260 XC25-036-230 TXV 35400 22.5 14.5 C35-50/60C SLP98UH090XV36C 8248261 XC25-036-230 TXV 35600 22.5 14.5 C35-50/60C SLP98UH090XV48C 8248262 XC25-036-230 TXV 34800 23 14 CBX32MV-036 5947287 XC25-036-230 TXV 35000 23 14 CBX40UHV-036 5947286 XC25-036-230 TXV 34600 22 13.5 CH23-51 EL296UH045XV36B 5947350 XC25-036-230 TXV 34600 22 13.5 CH23-51 EL296UH070XV36B 5947351 XC25-036-230 TXV 34600 22.5 14 CH23-51 EL296UH090XV36C 5947355 XC25-036-230 TXV 34800 22 14 CH23-51 EL296UH090XV48C 5947356 XC25-036-230 TXV 34800 22.5 14 CH23-51 SL280UH090V36B 5947352 XC25-036-230 TXV 34800 22 14 CH23-51 SL280UH090V48B 5947353 XC25-036-230 TXV 34800 22 14 CH23-51 SL280UH090XV48B 6108164 XC25-036-230 TXV 34600 22 13.5 CH23-51 SLP98UH070XV36B 5947354 XC25-036-230 TXV 34600 22.5 14 CH23-51 SLP98UH090XV36C 5947357 XC25-036-230 TXV 34800 22 14 CH23-51 SLP98UH090XV48C 5947358 XC25-036-230 TXV 34600 21 13 CH33-36A SL280UH070V36A 8930523 XC25-036-230 TXV 34600 23 14 CH33-36C SLP98UH090XV36C 8283553 XC25-036-230 TXV 34800 22 13.5 CH33-42 EL296UH045XV36B 5947359 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air.all ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

AHRI SYSTEM MATCHES NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or Capacity SEER EER Furnace No. Device Air Handler AHRI Reference XC25-036-230 TXV 34800 22.5 13.5 CH33-42 EL296UH070XV36B 5947360 XC25-036-230 TXV 35000 22.5 14 CH33-42 SL280UH090V36B 5947361 XC25-036-230 TXV 35000 22 14 CH33-42 SL280UH090V48B 5947362 XC25-036-230 TXV 35000 22 14 CH33-42 SL280UH090XV48B 6108165 XC25-036-230 TXV 34800 22.5 13.5 CH33-42 SLP98UH070XV36B 5947363 XC25-036-230 TXV 35800 23.5 14.5 CH33-43 EL296UH090XV36C 5947364 XC25-036-230 TXV 35800 23 14.5 CH33-43 EL296UH090XV48C 5947365 XC25-036-230 TXV 36000 23 14 CH33-43 SL280UH090V36B 8326607 XC25-036-230 TXV 35800 23.5 14.5 CH33-43 SLP98UH090XV36C 5947366 XC25-036-230 TXV 35800 23 14.5 CH33-43 SLP98UH090XV48C 5947367 XC25-036-230 TXV 36000 23 14 CH33-43B SLP98UH070XV36B 9105792 XC25-036-230 TXV 35400 22.5 14 CH33-44/48 EL296UH045XV36B 5947368 XC25-036-230 TXV 35400 22.5 14 CH33-44/48 EL296UH070XV36B 5947369 XC25-036-230 TXV 35600 23 14.5 CH33-44/48 SL280UH090V36B 5947370 XC25-036-230 TXV 35600 22.5 14.5 CH33-44/48 SL280UH090V48B 5947371 XC25-036-230 TXV 35600 22.5 14.5 CH33-44/48 SL280UH090XV48B 6108166 XC25-036-230 TXV 35400 22.5 14 CH33-44/48 SLP98UH070XV36B 5947372 XC25-036-230 TXV 35600 22.5 14.5 CH33-48 EL296UH090XV36C 5947373 XC25-036-230 TXV 35600 22.5 14.5 CH33-48 EL296UH090XV48C 5947374 XC25-036-230 TXV 35600 22.5 14.5 CH33-48 SLP98UH090XV36C 5947375 XC25-036-230 TXV 35600 22.5 14.5 CH33-48 SLP98UH090XV48C 5947376 XC25-036-230 TXV 34000 21 13 CH35-36A SL280UH070V36A 10304763 XC25-036-230 TXV 35000 22.5 14 CH35-42B SL280UH090V36B 10259354 XC25-036-230 TXV 35000 22.5 14 CH35-42B SL280UH090V48B 10259355 XC25-036-230 TXV 35800 23 14 CH35-42C EL296UH090XV36C 7164593 XC25-036-230 TXV 36000 23 14 CH35-42C EL296UH090XV48C 7164594 XC25-036-230 TXV 35800 23 14 CH35-42C SLP98UH090XV36C 7164595 XC25-036-230 TXV 36000 23 14 CH35-42C SLP98UH090XV48C 7164596 XC25-036-230 TXV 35400 22 13 CH35-48B EL296UH045XV36B 7164597 XC25-036-230 TXV 35600 23 14 CH35-48B EL296UH070XV36B 7164598 XC25-036-230 TXV 35800 23 14 CH35-48B SL280UH090V36B 7164599 XC25-036-230 TXV 35800 22 14 CH35-48B SL280UH090V48B 7164600 XC25-036-230 TXV 35600 23 14 CH35-48B SLP98UH070XV36B 7164601 XC25-036-230 TXV 35600 22 14 CH35-48C EL296UH090XV36C 7164602 XC25-036-230 TXV 35800 22 14 CH35-48C EL296UH090XV48C 7164603 XC25-036-230 TXV 35600 22 14 CH35-48C SLP98UH090XV36C 7164604 XC25-036-230 TXV 35800 22 14 CH35-48C SLP98UH090XV48C 7164606 XC25-036-230 TXV 34600 22 13 CR33-30/36 SL280DF090V48B 10190797 XC25-036-230 TXV 34400 22 13 CR33-30/36B SLP98DF070XV36B 9100730 XC25-036-230 TXV 35000 22 14 CR33-48 EL296DF045XV36B 5947344 XC25-036-230 TXV 35000 21.5 13.5 CR33-48 EL296DF070XV48B 5947345 XC25-036-230 TXV 35200 22 14 CR33-48 SL280DF090V48B 5947346 XC25-036-230 TXV 35000 22.5 14 CR33-48 SLP98DF070XV36B 5947347 XC25-036-230 TXV 35000 23 14 CR33-48 SLP98DF090XV36C 5947348 XC25-036-230 TXV 35000 22.5 14 CR33-48 SLP98DF090XV48C 5947349 XC25-036-230 TXV 34200 22.5 13.5 CX35-30/36C SLP98UH090XV36C 8248049 XC25-036-230 TXV 35400 22.5 14 CX35-36A SL280UH070V36A 10265941 XC25-036-230 TXV 35400 22.5 14 CX35-36A SL280UH070XV36A 8248263 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air.all ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. XC25-2 to 5 Ton Air Conditioner / Page 17

AHRI SYSTEM MATCHES NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or Capacity SEER EER Furnace No. Device Air Handler XC25-2 to 5 Ton Air Conditioner / Page 18 AHRI Reference XC25-036-230 TXV 35200 22.5 13.5 CX35-36B EL296UH045XV36B 8248264 XC25-036-230 TXV 35400 23 14 CX35-36B EL296UH070XV36B 8248265 XC25-036-230 TXV 35600 23.5 14.5 CX35-36B SL280UH090V36B 8248050 XC25-036-230 TXV 35600 22.5 14.5 CX35-36B SL280UH090V48B 8248051 XC25-036-230 TXV 35400 23 14 CX35-36B SLP98UH070XV36B 8248266 XC25-036-230 TXV 35400 22.5 14 CX35-48B EL296UH045XV36B 8248267 XC25-036-230 TXV 35600 23 14 CX35-48B EL296UH070XV36B 8248268 XC25-036-230 TXV 35800 23 14.5 CX35-48B SL280UH090V36B 8248052 XC25-036-230 TXV 35600 22.5 14.5 CX35-48B SL280UH090V48B 8248053 XC25-036-230 TXV 35600 23 14 CX35-48B SLP98UH070XV36B 8248054 XC25-036-230 TXV 35600 23.5 14.5 CX35-48C EL296UH090XV36C 8248269 XC25-036-230 TXV 35800 23 14.5 CX35-48C EL296UH090XV48C 8248055 XC25-036-230 TXV 35600 23.5 14.5 CX35-48C SLP98UH090XV36C 8248270 XC25-036-230 TXV 35800 23 14.5 CX35-48C SLP98UH090XV48C 8248271 XC25-036-230 TXV 35800 23 14.5 CX35-49C EL296UH090XV36C 8248272 XC25-036-230 TXV 35800 22.5 14.5 CX35-49C EL296UH090XV48C 8248273 XC25-036-230 TXV 35800 23 14.5 CX35-49C SLP98UH090XV36C 8248274 XC25-036-230 TXV 35800 22.5 14.5 CX35-49C SLP98UH090XV48C 8248275 XC25-036-230 TXV 35400 22.5 14.5 CX35-50/60C EL296UH090XV36C 8248276 XC25-036-230 TXV 35600 22.5 14.5 CX35-50/60C EL296UH090XV48C 8248277 XC25-036-230 TXV 35400 22.5 14.5 CX35-50/60C SLP98UH090XV36C 8248278 XC25-036-230 TXV 35600 22.5 14.5 CX35-50/60C SLP98UH090XV48C 8248279 XC25-048-230 TXV 47500 19 13 C35-48B SL280UH090XV48B 8248198 XC25-048-230 TXV 47500 19.5 13 C35-48C EL296UH090XV48C 8248036 XC25-048-230 TXV 48000 19 13 C35-48C EL296UH090XV60C 8248199 XC25-048-230 TXV 48000 19 13 C35-48C EL296UH110XV48C 8248200 XC25-048-230 TXV 47500 19 13 C35-48C EL296UH110XV60C 8248037 XC25-048-230 TXV 48000 19 13 C35-48C SL280UH090V60C 8248038 XC25-048-230 TXV 48000 19 13 C35-48C SL280UH110V60C 8248201 XC25-048-230 TXV 47500 19.5 13 C35-48C SLP98UH090XV48C 8248202 XC25-048-230 TXV 48000 19 13 C35-48C SLP98UH090XV60C 8248203 XC25-048-230 TXV 47500 19 13 C35-48C SLP98UH110XV60C 8248204 XC25-048-230 TXV 48000 19 13 C35-49C EL296UH090XV48C 8248205 XC25-048-230 TXV 48000 19 13 C35-49C EL296UH090XV60C 8248206 XC25-048-230 TXV 48000 19 13 C35-49C EL296UH110XV48C 8248207 XC25-048-230 TXV 48000 19 13 C35-49C EL296UH110XV60C 8248208 XC25-048-230 TXV 48000 19 13.5 C35-49C SL280UH090V60C 8248209 XC25-048-230 TXV 48000 18.5 13 C35-49C SL280UH110V60C 8248210 XC25-048-230 TXV 48000 19 13 C35-49C SLP98UH090XV48C 8248211 XC25-048-230 TXV 48000 19 13 C35-49C SLP98UH090XV60C 8248212 XC25-048-230 TXV 48000 19 13 C35-49C SLP98UH110XV60C 8248213 XC25-048-230 TXV 47500 20 13 C35-50/60C EL296UH090XV48C 8248214 XC25-048-230 TXV 47500 20 13 C35-50/60C EL296UH090XV60C 8248215 XC25-048-230 TXV 47500 20 13 C35-50/60C EL296UH110XV48C 8248216 XC25-048-230 TXV 47500 19.5 13 C35-50/60C EL296UH110XV60C 8248217 XC25-048-230 TXV 47500 20 13 C35-50/60C SL280UH090V60C 8248218 XC25-048-230 TXV 47500 19.5 13 C35-50/60C SL280UH110V60C 8248219 XC25-048-230 TXV 47500 20 13 C35-50/60C SLP98UH090XV48C 8248220 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air.all ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

AHRI SYSTEM MATCHES NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or Capacity SEER EER Furnace No. Device Air Handler AHRI Reference XC25-048-230 TXV 47500 20 13 C35-50/60C SLP98UH090XV60C 8248221 XC25-048-230 TXV 47500 19.5 13 C35-50/60C SLP98UH110XV60C 8248222 XC25-048-230 TXV 48000 20.5 13.5 CBX32MV-048 5947379 XC25-048-230 TXV 48500 20.5 13.5 CBX32MV-060 5947380 XC25-048-230 TXV 48500 21 13.5 CBX40UHV-048 5947377 XC25-048-230 TXV 48500 20.5 13.5 CBX40UHV-060 5947378 XC25-048-230 TXV 47000 20 13 CH23-65 SL280UH090V60C 10260324 XC25-048-230 TXV 47500 20 13 CH33-48C SLP98UH090XV60C 8086945 XC25-048-230 TXV 48500 20.5 13 CH33-49 EL296UH090XV48C 5947464 XC25-048-230 TXV 48500 20.5 13 CH33-49 EL296UH090XV60C 5947465 XC25-048-230 TXV 48500 20.5 13 CH33-49 EL296UH110XV48C 5947466 XC25-048-230 TXV 48500 20.5 13 CH33-49 EL296UH110XV60C 5947467 XC25-048-230 TXV 48500 20.5 13.5 CH33-49 SL280UH090V60C 5947468 XC25-048-230 TXV 48500 20.5 13.5 CH33-49 SL280UH090XV60C 6108188 XC25-048-230 TXV 48500 20.5 13 CH33-49 SL280UH110V60C 5947469 XC25-048-230 TXV 48500 20.5 13 CH33-49 SL280UH110XV60C 6108189 XC25-048-230 TXV 48500 20.5 13 CH33-49 SLP98UH090XV48C 5947470 XC25-048-230 TXV 48500 20.5 13 CH33-49 SLP98UH090XV60C 5947471 XC25-048-230 TXV 48500 20.5 13 CH33-49 SLP98UH110XV60C 5947472 XC25-048-230 TXV 48000 20.5 13 CH33-50/60C EL296UH090XV48C 5947473 XC25-048-230 TXV 48000 20 13 CH33-50/60C EL296UH090XV60C 5947474 XC25-048-230 TXV 48000 20.5 13 CH33-50/60C EL296UH110XV48C 5947475 XC25-048-230 TXV 48000 20 13 CH33-50/60C EL296UH110XV60C 5947476 XC25-048-230 TXV 48500 20 13.5 CH33-50/60C SL280UH090V60C 5947477 XC25-048-230 TXV 48500 20 13.5 CH33-50/60C SL280UH090XV60C 6108170 XC25-048-230 TXV 48000 20 13 CH33-50/60C SL280UH110V60C 5947478 XC25-048-230 TXV 48000 20 13 CH33-50/60C SL280UH110XV60C 6108171 XC25-048-230 TXV 48000 20.5 13 CH33-50/60C SLP98UH090XV48C 5947479 XC25-048-230 TXV 48000 20 13 CH33-50/60C SLP98UH090XV60C 5947480 XC25-048-230 TXV 48000 20 13 CH33-50/60C SLP98UH110XV60C 5947481 XC25-048-230 TXV 48000 20 13 CH33-60D EL296UH135XV60D 5947482 XC25-048-230 TXV 48000 20 13.5 CH33-60D SL280UH135V60D 5947483 XC25-048-230 TXV 48000 20 13 CH33-60D SLP98UH135XV60D 5947484 XC25-048-230 TXV 48500 20 13.5 CH33-62D EL296UH135XV60D 5947485 XC25-048-230 TXV 48500 20 13.5 CH33-62D SL280UH135V60D 5947486 XC25-048-230 TXV 48500 20 13.5 CH33-62D SLP98UH135XV60D 5947487 XC25-048-230 TXV 48000 20 13 CH35-48C SL280UH090V60C 10259356 XC25-048-230 TXV 48000 20 13 CH35-51C EL296UH090XV48C 7164581 XC25-048-230 TXV 48000 20 13 CH35-51C EL296UH090XV60C 7164582 XC25-048-230 TXV 48000 20 13 CH35-51C EL296UH110XV48C 7164583 XC25-048-230 TXV 48000 20 13 CH35-51C EL296UH110XV60C 7164584 XC25-048-230 TXV 48000 20 13 CH35-51C SL280UH090V60C 7164585 XC25-048-230 TXV 48000 20 13 CH35-51C SL280UH110V60C 7164586 XC25-048-230 TXV 48000 20 13 CH35-51C SLP98UH090XV48C 7164587 XC25-048-230 TXV 48000 20 13 CH35-51C SLP98UH090XV60C 7164588 XC25-048-230 TXV 48000 20 13 CH35-51C SLP98UH110XV60C 7164589 XC25-048-230 TXV 48000 20 13 CH35-60D EL296UH135XV60D 7164590 XC25-048-230 TXV 48000 20 13 CH35-60D SL280UH135V60D 7164591 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air.all ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. XC25-2 to 5 Ton Air Conditioner / Page 19