Warm Line IV Fluid Warmer Portable and light weight Only warms IV fluids not transfusion fluids Convenient strap to hang on a IV pole Temperature displayed appears either in Fahrenheit or Celsius Overheating Temperature protection Table of Contents General Information......................... 2 Precautions................................ 2 Warnings.................................. 2 Introduction............................... 3 Working Principle.......................... 3 Main Technical Specifications................ 3 Composition of Product..................... 4 Product Illustraion......................... 4-5 User s Operation............................ 6 Maintenance............................... 6 Equipment Alert............................ 7 Warranty.................................. 8 Troubleshooting and Solution................ 8 Specifications............................... 8 2
General Information The Warm Line IV Fluid Warmer is a dry- heat device. This unit is designed to warm IV fluids safely through the heating plate. The Warm Line does not control the fluid flow rate. Fluids can be warmed to temperatures between 96º-104º F (35.5ºC-40ºC) at flow rates up to 320ml/hr. The IV warmer is not recommended for blood because it can reach 104ºF. Precautions Save this Manual for Future Reference IMPORTANT: Before using the Warm Line IV Fluid Warmer, please read and understand this User s Guide and the SAFETY PRECAUTIONS prior to use. If you have any questions, please contact Jorgensen Laboratories at 1-800-525-5614. Electromagnetic Interference- The Warm Line IV Fluid Warmer uses Radio Frequency (RF) energy for its internal function. The RF emissions are very low and are not likely to cause interference with nearby electronic equipment. If interference is detected with other devices and the Fluid warmer, do the following: Remove interfering device from the room Plug the IV Fluid Warmer into an isolated outlet Increase separation between the fluid warmer and the interfering device Warnings Failure to follow the warnings could result in the administration of air to the patient which could cause death or serious injury. All Air must be purged from the fluid lines prior to connection of the patient. Monitor the fluid lines to insure they are air free. Never administer fluids if there are air bubbles in the line between the drip chamber and the patient connection. Prohibit from using the IV Fluid Warmer around water as it can cause electrical shock The IV Fluid warmer shall be used under the guidance of medical staff and shall not be used with heat sensitive medications. Unauthorized personnel should not dismantle the machine. The IV Fluid Warmer heating plate is hot, do not touch the plate as it can result in injuries. Do not flush or emerge the IV Fluid Warmer in any fluid, or cleaning solutions. 2
Introduction The use of room temperature (70ºF/21ºC) IV fluids in a patient suffering from shock, or susceptibility to hypothermia should be avoided. Ideally fluids should be administered as close to body temperature as possible for better therapeutic results. Working Principle The Warm Line IV Fluid Warmer is an indirect heating device (dry warmer). The IV fluids are heated as the fluids pass through the channel of the warmer. Main Technical Specifications Environmental conditions of transportation and storage Ambient Temperature: -40~+55ºC Relative Humidity: 80% Environmental conditions of transport and storage Ambient temperature 5~40ºC Relative humidity: 80% Power Supply: AC 110 ± 11V or AC 220V ± 23V Frequency: 60Hz ±1Hz or 50Hz ± 1Hz Input power 70W Temperature Controlling: Liquid temperature at the entrance: 15ºC ~ 25ºC or 59ºF ~ 77ºF Liquid temperature at the exit: 35ºC ~ 46ºC or 95ºF ~ 114.8º F Note: The data measured is under the conditions of 20ºC ± 2ºC for the liquid temperature in entrance and (54-66) drops/min for the fluid speed Displaying error of temperature: 2ºC or 3.6ºC Note: The displaying error measured is under the conditions of surrounding temperature for (20 ± 2) ºC, (20 ± 2) ºC for the liquid temperature in entrance and (54-66) drops/min for the fluid speed. Safety: The power supply will be automatically cut off when the heating plate reaches 47ºC + 2ºC/116.6ºF + 3.6ºF. A buzzer alarm will sound and red-guided light illuminates 3
Suitable speed of infusion fluid: 40 ~ 80 drops/min (2-5.3ml/min) Fuse: T 500mAL 250V size 3.9 X 11mm Max. Weight: < 600g Composition of Product The IV Fluid Warmer is composed of four parts: 1. Heating Source: the component that heats the liquid flowing through the warmer, including heating parts and the aluminum plate used for the installation of the IV fluid tubing. 2. Power Supply: supplying power to temperature measuring and controlling circuits. 3. Control Module: the circuits for temperature measurement, temperature displaying and heating parts controlling. 4. Shell Body: including upper cover and lower cover. A A. LCD Display: displaying fluid temperature B. C/ F Switch button: the button is used to convert temperature between Celsius or Fahrenheit. C. Alarm Indicator: red LED light will glimmer if the heating plate reaches or exceeds 47ºC, meanwhile the warmer gives audible alarm. The alarm will stop automatically when the temperature of the heating plates goes back to normal. B C D E D. Power Indicator: indicates the power of the warmer is connected when the LED light is green. D. Run Indicator: indicates the warmer is running when the LED light is yellow. 4
IV INFUSION TUBE F G H I F. Adjustable Suspension Belt: to hang the warmer on an infusion pole or another support and is adjustable. G. Heating Plate: conduct heat to the IV fluid tube inside the tube channel, which the infusion fluid is warmed. H. Tube Channel: the IV fluid tubing is placed in the S -Shape channel, which is 4mm depth and 4mm width. I. Magnetic Door Closure: keeps the door closed tightly with magnetic force, and prevent heat from leaking from the plates. J. Power Cord: 110V/220V Ac power supply K. Front cover J K 5
User s Operation Operation Steps: 1. Hang the warmer on the IV pole, adjust the strap to the appropriate length Note: If the infusion pump is being used, it should be placed slightly under the IV line s exit from the pump. 2. Open the door, place the IV line ( 4mm) into the S-shaped groove on the heating plate. Once the IV line is placed in the groove, close the door. 3. Plug the power cord into a properly grounded outlet. The power indicator light will be green, indicating the warmer has been turned on. 4. Press the grey button on the front panel to switch the temperature between Fahrenheit and Celsius. 5. The warmer will start to warm up immediately once it is plugged in. The run indicator will flash Yellow when the device is heating up and will go off when the heating plate reaches approximately 105ºF (41ºC). The warmer will automatically turn on again once the temperature inside the warmer decreases. 6. The displayed temperature value on the LCD Display is the temperature at the exit of the warmer. 7. When finished using the warmer, remove the power cord from the outlet. Clean the surface of the IV Fluid Warmer. Using a cloth wipe the unit with 70-75% solution of Isopropyl Alcohol and water to clean and sterilize the unit. (75% is the maximum strength recommended) Important: A backup system with the warmer is independent of the main controller. If the heating plate exceeds a temperature of 117ºF (47ºC) the alarm indicator will light up and the system will immediately interrupt the power to the heaters. Maintenance 1. The surface of the device should be kept clean 2. The heating surface should be cleaned before/after use to prevent cross infection. 3. The surface of the warmer should be protected from contacting or hitting with sharp objects, which may cause damages of the warmer and the infusion tube, thus may cause patients infection. 4. Keep the Warm Line IV Warmer dry. Any liquid into the warmer can cause significant damage. 5. Make sure the device is secured to the IV Pole or other support before Operation. 6
Equipment Alert The IV fluid warmer must be unplugged when not in use Note: Failure to do so could result in electrical failure Do not immerse in cleaning/sterilization solution Note: Do not submerge or soak unit. It is fluid resistant, not fluid proof For grounding reliability of the Fluid Warmer, plug only into a properly grounded outlet. Isolation of the power supply can only be achieved by disconnecting the cord from the main power supply. The length of the IV line between the patient and warmer should be limited. If over 10 from the patient heat loss will occur. The warmer is designed to be IV Pole mounted with the hanging belt, is adjustable Do not wrap cord around the IV Fluid Warmer. May cause mal function or cord damage may result from improper storage. See picture below. 7
Warranty Warm Line IV Fluid Warmer has a one-year warranty, this includes defects in materials and workmanship under normal use. The warranty does not cover any damages due to misuse of the machine. Please contact Jorgensen at 800-525-5614 if any defects occur during the one-year warranty period. After the warranty period Jorgensen Laboratories will provide service/repairs. Troubleshooting and Solution Trouble Possible Cause Solution LED doesn t turn on 1. No AC Power 2. Broken LED 1. Check AC Power 2. Change LED No heating Non-stop heating 1. Control circuit fails 2. Warmer fails Non-stop heating 1. Contact Jorgensen for Service 2. Contact Jorgensen for Service Contact Jorgensen for Service Specifications Suggested Operating Temp. 68 77 F (20 25 C) Relative Humidity 80% Maximum Power Requirement 110VAC/60HZ Power Consumption 70 Suitable speed of Infusion fluid 40-80 drops (2-5.3 ml/min) Dimensions 7.7 x 3.5 x 2.2 190 x 100 x 60 mm Weight 1.32 lbs. (0.6 kg) 8