Analog Annunciator Unit SACO 16 A3. Product Guide

Similar documents
Annunciator Unit SACO 16 D1. Product Guide

Annunciator unit. Application

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

REA 105 Arc Protection Module. Operator s Manual

SPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No.

Panel Mounted Fault Annunciator Series

AO Annunciator Module

SACO 16D3 Annunciator unit. User s manual and Technical description

Universal fault annunciator for panel mounting

Panel Mounted Fault Annunciator Series

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Window facia fault annunciators

1. General Safety Block diagram Description of operation Connections Commissioning...11

Parameterisable compact fault annunciator with permanent display

VAMP 121. Arc protection unit. User manual

VAMP 120 & 121. Arc flash detection units. Product picture

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

02/11/2015

02/11/2015

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

M1000 Alarm Annunciator

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Universal controller for panel mounting Models CS6S, CS6H, CS6L

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Panel Mounted Fault Annunciator Series

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

FireNET Plus Wiring Instructions

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MATERIAL AND EQUIPMENT STANDARD FOR ALARM AND PROTECTIVE SYSTEMS FIRST EDITION MAY 2006

Process Alarm Solutions

1.7. Insulation fault evaluators EDS460/490 EDS461/491

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

CTT8 TEMPERATURE MONITOR DEVICE

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Insulation fault evaluator EDS460-DG

PTE0705 Electric Fence Monitor

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

MSM - Expansion modules

ME 3011C / Alarm Indication / Quick Reference Guide

Intelligent addressable fire alarm control panel

AIS750 Series Alarm Annunciator

S304 and S305 Dust Emission Monitors. User Manual. Distributor

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

HTC-915-CONT. Heat-Trace Control system

MO n : 12JMC rév A

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

I/A Series 716C 1/16 DIN Temperature Controller

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Type TEC, Transformer Electronic Control System

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Multi-Gas-Controller MGC2

/8 DIN Level Indicator

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

20 Light Remote Annunciator

Installation, Operating and Maintenance Manual

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Danfoss gas detection units

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

M2500 Engine Controller Installation Manual

Remote alarm indicator and test combination MK2430

SET Installation and Operating Instructions. Level switch for one sensor

TCM-2 Thyristor Control Module DATA SHEET

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Operating Manual MS220DA

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

On the job around the clock 24/7: Fire detection systems

NGC-20-C-E and NGC-20-CL-E

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Alarm Modules Section E

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Monitoring Devices 11/1

Application, Installation, Operation & Maintenance Manual

Universal Input Digital Panel Meter With Bargraph, NA3

Vocia VACIE. Reference Guide

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

NGC-20-C-E and NGC-20-CL-E

Model A1600 Series Annunciator

RS485 MODBUS Module 8AI

VACIE REFERENCE GUIDE REVISION 1.2.6

SET-2000 Hi Level/Oil

DRAFT 20 October 2014

Transcription:

Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full choice of 26 standardized fieldselectable channel input signal types Four alarm/trip levels per channel; two low set and two high set points The last thirty events with time markings stored for local presentation Bar graph, curve or numerical display of set and measured parameter values Extensive data communication via the serial interface and the SPA bus Parameter selection and adjustment from front panel or via serial interface Sophisticated hardware and software selfsupervision system for maximum operational reliability under the most demanding environmental conditions Powerful software support for parameterization of the relay, for reading measured and recorded values, events, etc., and for storing readings Member of the SPACOM product family and ABB s Distribution Automation system CE marking according to the EC directive for EMC Application The analog annunciator unit is used in a variety of applications requiring monitoring of analog quantities such as temperature, current, voltage, power, etc. in power plants, substations and industry. The equipment is also used in off-shore installations. For temperature measurement standard Pt or Ni sensors are used. For measuring electrical quantities measuring transducers with standard ma or V outputs are employed. The annunciator units can be used as independent stand-alone units, or they can be integrated via a fibre-optic bus to form complete supervision, event sequence reporting and data acquisition systems. 3

Design The channels of the analog annunciator unit measure voltage, current and resistance via sensors or transducers in the process. Further, contact signals can be wired to the input channels. The signal type can be separately set for each channel. The channel inputs are galvanically separated from earth and from the digital part of the annunciator electronics, but the channels are galvanically interconnected. This arrangement facilitates the supervision and the indication of earth faults in the transducers or the transducer wiring. The alarm channel inputs accept the following signal levels: 0 5 ma, 1 5 ma, 0 20 ma and 4 20 ma, 0 1 V, 0 5 V, 1 5 V, 0 10 V and 2 10 V. The following standard sensors types can be used for temperature measurement: Pt 100, Pt 250, Pt 1000, Ni 100, Ni 120, Ni 250, Ni 1000. Further, any Pt or Ni signal within the range 65 1000 Ω, potentiometric signal within the range 0 200 Ω, 0 500 Ω, 0 1 kω, 0 2 kω, 0 2.5 kω, 0 10 kω can be used and scaled. For the resistance sensors two- or three-wire connection can be used. In addition, the input channels can be activated by a making or a breaking contact. The values measured can be shown as numerical values, bar graphs or curves on the dot matrix display on the front panel. The same information can also be read by a superior system via the serial interface. The content of the event sequence register can be read on the display. The total system can be configured by means of the push-buttons and the display on the front panel, or via the serial interface. When a measured signal exceeds or falls below the set start value of the channel a visual indication is obtained on the alarm panel. At the same time the acoustic alarm output contact picks up and, if configured, a group alarm relay operates. The event thus generated is stored in the event register. Any information generated in the annunciator unit can be read by a hierarchically superior system via the serial interface. Data communication The relay is provided with a serial interface on the rear panel. By means of a bus connection module type SPA-ZC 17/S or SPA- ZC 21/S the relay can be connected to the fibre-optic SPA bus. The bus connection module type SPA-ZC 21/S is powered from the host relay, whereas the bus connection module SPA-ZC 17/S is provided with a built-in power unit, which can be fed from an external secured power source. The relay communicates with higher-level data acquisition and control systems over the SPA bus. Self-supervision The annunciator incorporates a sophisticated self-supervision system which increases the availability of the device and the reliability of the system. The self-supervision system continuously monitors the hardware and the software of the equipment. The system also supervises the operation of the auxiliary supply module and the electronics voltages generated by the module. Auxiliary supply voltage The auxiliary supply of the relay is obtained from an internal plug-in type power supply module. Two auxiliary power module versions are available: type SPGU 240A1 for the supply voltage range 80 265 V ac/dc and type SPGU 48B2 for the supply voltage range 18 80 V dc. The power supply module forms the internal voltages required by the annunciator. 4

Technical data Table 1: Annunciator channels Number of channels per annunciator unit 16 Selectable transducer signal types Scaling types Signal filtering, selectable time basis for 0 90% step response Set-point values per channel Channel starting delay at set-point value transition Channel resetting delay at set-point value resetting Deadband setting range, on a per channel basis Measuring accuracy Transducer supply Transducer supervision, measuring mode Transducer circuit earth-fault supervision Transducer oscillation supervision Reference channel function Reference value deviation set-point values Recording of change in value to be measured 0 5 ma, 1 5 ma, 0 20 ma, 4 20 ma 0 1 V, 0 5 V, 1 5 V, 0 10 V, 2 10 V Pt 100, Pt 250, Pt 1000 Ni 100, Ni 120, Ni 250, Ni 1000 One selectable Pt or Ni signal within the range 65 1000 Ω, potentiometric signal within the range 0 200 Ω, 0 500 Ω, 0 1 kω, 0 2 kω, 0 2.5 kω, 0 10 kω, contact function linear or non-linear 0.3 s, 1 s or 5 s two HI and two LO set-points or one HI and one LO plus one rise time and one fall time set-point 0 255 s 0 255 s 0 100 per mille 0.5% of scale range 24 V dc ±10%, max. 320 ma Fully selectable upper and lower transducer signal limit values Integrated with a sensitivity of 5 10 kω Selectable 1 255 events/s. Can even be set out of function Any channel may be used as reference channel. The reference value may also be the average value of the measurement value of channels 2 16 Two selectable set-point values, one upper and one lower, separately given at 33% and 83% of the measuring range. Between these given set-point values the set-point values are interpolated and outside the given set-point values the set-point values are extlrapolated from the given set-point values Selectable setting value for size of change to be stored as an event in the event sequence register Table 2: Realarm functions Permanently groupable realarm output relays Audible alarm output Self-supervision system output Relay contact rated current/max. breaking current Six relays with one NO contact per relay. The contacts may be given NC function by means of jumpers One relay with one NO contact (NC contact by jumper) One relay with one NO contact (NC contact by jumper) 3 A/250 V ac or dc 5

Table 3: External control inputs Audible alarm reset Alarm acknowledge Alarm channel reset Remote testing Control of unit into LOCAL mode Control of unit into REMOTE mode Clock synchronization NO contact circuit NO contact circuit NO contact circuit NO contact circuit NO contact circuit NO contact circuit NO contact circuit, pulse length > 100 ms, 48 V dc, 4 ma Table 4: Data communication Transmission mode Coding Data transfer, selectable Electrical/optical bus connection module, powered from the host unit Electrical/optical bus connection module, powered from the host unit or from an external power source for plastic core cables for glass fibre cables for plastic core cables for glass fibre cables Fibre-optic serial bus ASCII 4800 or 9600 Bd SPA-ZC 21BB/S SPA-ZC 21MM/S SPA-ZC 17BB/S SPA-ZC 17MM/S Table 5: Auxiliary supply modules Type of module SPGU 240A1 rated voltages U n 110/120/230/240 V ac 110/125/220 V dc operative range 80 265 V ac/dc SPGU 48B2 rated voltages U n 24/48/60 V ac operative range 18 80 V dc Power consumption under quiescent/operation ~20 W/~30 W conditions Table 6: Tests and standards Test voltages Test voltages Environmental conditions Between channel and control inputs and annunciator case, supply inputs and relay outputs Dielectric test voltage (IEC 60255-5) 500 V, 50 Hz, 1 min Impulse test voltage (IEC 60255-5) 1 kv, 1.2/50 µs, 0.5 J HF test voltage (IEC 60255-5) 1 kv, 1 MHz Between supply inputs and case, relay outputs and case, supply inputs and relay outputs between themselves Dielectric test voltage (IEC 60255-5) 2 kv, 50 Hz, 1 min Impulse test voltage (IEC 60255-5) 5 kv, 1.2/50 µs, 0.5 J HF test voltage (IEC 60255-5) 2.5 kv, 1 MHz Ambient service temperature range -10 +55 C without matrix display Ambient service temperature range, -10 +45 C including matrix display Long term damp heat withstand <95%, +40 C, 56 d/a (IEC 60068-2-3) Ambient transport and storage -20 +55 C temperature range Degree of protection by enclosure when IP 54 panel-mounted Weight of annunciator unit ~4.5 kg 6

Block diagram Auxiliary supply 1:st 2:nd Transducer supply and cable shield connection 16 transducer connections Remote ackn., reset, test, local/remote control and synchronizing inputs Group alarm 1...6, audible alarm and internal supervision outputs 24 V 48 V 48 V Internal supply, analogue Internal supply, logics CPU Audible alarm Internal supervision SPA-bus connection Man-machine interface Fig. 1 Block diagram 7

Mounting and dimensions Flush mounting 226 30 285 251 229 34 214 ±1 162 136 139 ±1 Panel cut-out dim16d3 Fig. 7 Flush-mounting relay case (dimensions in mm) Semi-flush mounting a b Raising frame SPA-ZX 301 SPA-ZX 302 SPA-ZX 303 a 211 171 131 b 74 114 154 SFM16D3 Fig. 8 Semi-flush mounting relay case (dimensions in mm) Mounting in 19 inch cabinets and frames An ancillary mounting plate, height 4U (~177 mm), is recommended to be used when the aciators are to be mounted in 19 inch frames or cabinets. The ancillary mounting plate type SPA-ZX 104 accommodates three units, type SPA-ZX 105 two units and type SPA-ZX 106 one unit. SPA-ZK304 +0,4 482,6 0 (19") SPA-ZK305 21,5 101,6 7 +0,4 177 0 (4U) Fig. 9 Mounting cabinets and frames (dimensions in mm) 304_5dim 8

Ordering Table 10: When ordering, please specify: Ordering information Ordering example 1. Type designation and quantity SACO 16A3, 5 pieces 2. Order number RS 812 016-AA 3. Auxiliary voltage U aux = 110 V dc 4. Accessories - 5. Special requirements - Table 11: Order numbers Analog annunciator unit SACO 16A3 Analog annunciator unit SACO 16A3R without a dot matrix display on the front panel The last two letters of the order number indicate the auxiliary voltage U aux of the annunciator unit as follows: RS 812 016-AA, -BA RS 812 015-AA, -BA AA equals U aux = 80 265 V ac/dc BA equals U aux = 18 80 V dc References Table 12: Additional information Analogue input annunciator, User s manual and Technical description 1MRS751015-MUM 9

ABB Oy Distribution Automation P.O. Box 699 FI-65101 Vaasa, FINLAND Tel +358 10 22 11 Fax +358 10 224 1094 www.abb.com/substationautomation