Heat Exchanger Module for Industrial Applications

Similar documents
PCH/new Series. High performance, total flexibility

Rapid. Suspended Warm Air Heater. Caring for the environment!

PCH Heating Condensing Module for Air Handling and Roof Top Units

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

PK-N Floor Standing Heater

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Use, Installation and Maintenance Manual EMS-N/GH, EMS-K/GHK, EMS-R/GHR Warm Air Heater Module

Floor Standing Warm Air Heater series PK

APEN GROUP SPA is a leading manufacturer of heating systems, who is active both in national and international ambits.

Max-3 Steel Shell Boiler

Importance of a Draught Regulator

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

Waste/Multi Oil Boilers from Flexiheat

Originators of the Flexible Water Tube design

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

INSTALLATION AND OPERATION MANUAL

Floor Standing Warm Air Heater PKE-SPORT

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

The ultimate in air handling units: directly and indirectly fired

NEW. Quality and efficiency made of experience! Oil- and gas heated boilers for the professionals manifold proven.

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

The ultimate in air handling units: directly and indirectly fired

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

ORT6WXA ORT9WXA Slide-out Rangehoods

PWM expansion valves 2028

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Operating, Installation and Maintenance Manual PRH Warm Air Heater Module 2 stages

Prextherm Rsw High efficiency steel pressurised boilers

INDUSTRIAL MICRODIFFUSION OIL BURNERS

UltraOil Condensing Oil Boiler

V-Line. Nozzle-mix line burner

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

USERS MANUAL FOR GAS BOILERS

Capri R CH only, oil-fired, cast iron boiler

STATIONARY HEATERS 2011/

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

The ultimate in air handling units: directly and indirectly fired

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

... UDSA - UDSBD Gas fired unit heaters...

TopGas Wall Hung Condensing Gas Boiler

Series LV AIRFLO. In-duct firing line burner

ENERGY TOP. Condensing boiler solutions

COMPACT VENTILATION UNITS DUPLEX R5

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

PREEVA air handling unit

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

ERGONOMICS AND CLEANING EXPERIENCE AND PASSION AT YOUR SERVICE

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

ACCUMULATION OF EUROPEAN CLASS

The iqe Boiler Range. Combination and System T Boilers.

Gas-fired unit heaters for indoor installation

INDITHERM. Low temperature gas burners

1 - High-velocity gas burners

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Gas heaters and convectors ROBUR

Wall-hung boilers. Spare parts catalogue. ecotec plus

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

RHC & RHCE gas fired heating coils

ROTARY DRYER CONSTRUCTION

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

PORTABLE HEATERS MCS GROUP.

PORTABLE HEATERS FOR PROFESSIONAL use

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Product catalogue Pleszew, 2015

Mynute Green Condensing Wall-Hung Boilers

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

User, Installation, and Maintenance Manual

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

PORTABLE HEATERS FOR PROFESSIONAL USE

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Eco Angus Wood Pellet Boilers

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Pioneers of heating with biomasses

Capri B Cast iron combination oil-fired boiler with water tank

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

The WCGH High Efficiency Commercial Water Heater with Storage Tank

N 700 BOILING PANS ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

TECHNICAL DATA MOBILE WASTE INCINERATOR

PELLETS & WOOD HYBRID FIREPLACES

ENTROPIE boiler TT100-01

WARNING FIRE OR EXPLOSION HAZARD.

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Transcription:

G0 Heat Exchanger Module for Industrial Applications

EQUIPMENT for industrial processes Wide product range, High efficiency, Custom design Manufacturing processes often require different forms of heating, as for heat treatment and drying processes, which use air as a heat carrier. Apen Group has more than 45 years of experience in the study and production of hot air generators for drying equipment. Our Investments in R&D projects for the development and construction of energy efficient systems, allow the industrial customer to benefit from: reliable products, energy-saving advantages and low maintenance requirements which help to reduce the operating costs. Process safety and equipment s lifespan is guaranteed by high quality resistant materials and design. ApenGroup is able to supply an extended range of heat exchangers and to fulfill customized requirements. Our design department is able to support the customer in finding the optimal solution in any planning phase. Application Fields Coating and Painting Drying of food processes. Drying processes for components Ceramics drying processes Textile and clothes drying Heating in concrete making for construction industry Agricultural products drying as for Cereals and Tobacco. Textile and clothes drying Coating and painting Coating and painting Ceramics drying processes 2

EQUIPMENT for industrial processes Product Types Combustion chambers series G0 (heat exchangers) are manufactured in 12 different capacities ranging from 50 kw to 1170 kw of output, depending on the construction type, and can be fired either with gas or liquid fuels. Applications for AHUs and Rooftop (standard application: low t needs) G0XXXX and G0XXXX-TF series include basic models conceived to work in standard operating plants, i.e. common air handling units where temperatures differentials are not too high and air flow rates are consistent enough ( t values ranging from 20 to 35 C ). TF series differs from basic series because of its built-in front flue gas exhaust, installed on the same side as the burner, to ease installation in specific cases. Applications Processing Machinery (special application: hi t needs) G0XXXX-2 and G0XXXX-310 have been designed for special working conditions, such as process plants, painting or drying cabinets, or high static pressures of air). G0XXXX-2 exchangers can stand high pressure (up to 2,500 Pa) thanks to their solid construction and highresistance materials, while the advanced materials used for G0XXXX-310 exchangers allow these units to work at very high air temperatures (up to 280 C) or with high temperature differentials. Textile and clothes drying Industry Drying of food processes Ceramics drying processes 3

G0 series / Heat Exchangers Technical Features AISI 430 and AISI 310 stainless steel combustion chamber, with wide exchange surface Flame inversion furnace with three-pass, fully welded, flue gas layout. High efficiency heat exchanger made of AISI 441 stainless steel with low carbon content. The exchanger is formed by a streamlined tube bundle with conic section with an aerodynamic profile(low pressure drops in air circuit and high efficiency) Patented tube heat exchanger (Patent n. MI94U00260). Efficiency up to 94,6%. In compliance with all EC existing regulations. 4

Why choose G0? Reliability Quality Technology Ecology Security Advanced construction methods Efficiency up to 102% These are just some of the features that make ApenGroup s heat exchanger modules the excellence of the heating system. Choosing the Burner The following types of burners can be installed with GO modules Modulation Two stages (high/low flame) ON/OFF Gh modules can be installed with burners produced by main burner manufactures on the market. High efficiency exchanger modules can only be matched to gas burners. 5

GO / Features Table of materials The following table shows naming correspondence and content for steel types used in the heat exchangers G0: Other materials and/or requirement will be evaluated according to specific requests. Table of stainless steel materials USA EN FORMULA AISI 430 1.4016 X6 Cr17 AISI 310 1.4845 X8 CrNi 25-21 AISI 441 1.4509 X2 CrTiNb 18 AISI 304 1.4301 X5 CrNi 18-10 Condensate Drain When exchangers series G0 are assembled into Roof Top or air handling units that feature high air flow rates and minimum heat drop, a condensate drain system from the exchanger must be provided. All exchangers include five fittings for condensate drain. These fittings are installed on front, back, left and right manifold and on the bottom wall of back flue pipe. Condensate is allowed only if a gas burner is installed: it must be totally absent when oil burners are used. Condensate Drain Standard on the back ( A request on the front ). 6

GO / Assembling the module into the units AIR FLOW NOT ALLOWED The module can be installed into air heating units either vertically or horizontally. Air can be blown in two ways: PARALLEL FLOW: cold air flows from colder to warmer end of the exchanger (tube bundle). COUNTER-CURRENT FLOW: cold air flows from warmer to colder end of the exchanger (combustion chamber). You can choose the solution that best suits your needs. PARALLEL FLOW COUNTER-CURRENT FLOW: AIR FLOW NOT ALLOWED Modules in PARALLEL Assembling one or more modules When required power output exceeds max output or is below minimum output of a single exchanger, multiple G0xxxx modules can be assembled into a single AHU, RTU or process heater unit, thus covering any range of required output. Using convenient precautions, modules can be assembled either in series or in parallel and air flow can be parallel or counter-current to heat flow. Modules in series 7

G0 /Technical Data Model G07580 G07680 G07780 G07880 Type of Appliance B23 Ec Approval 0694BP0758 Nox Class 4-5 with Gas Burner LOW NOx min >91% max min >91% max min >91% max min >91% max Furnace Heat Input KW 24,8 34,0 49,5 43,0 61,3 86 68,5 100,5 137,0 96,0 131,4 195,0 Useful Heat KW 23,5 31,0 43,6 40,4 56,0 75,2 64,3 91,9 120,1 90,2 120,3 171,0 Combustion Efficiency % 94,8 91,2 88,1 94,0 91,3 87,9 94,0 91,4 87,7 94,0 91,4 87,7 Chimney Loss - Burner On % 5,2 8,8 11,9 6,0 8,7 12,1 6,0 8,6 12,3 6,0 8,6 12,3 Chimney Loss - Burner Off % < 0,1 < 0,1 < 0,1 < 0,1 Casing Losses % 1,83 1,64 1,46 1,26 Furnace Pressure Pa 7 15 17 11 18 25 14 30 40 13 28 50 Furnace Volume m 3 0,06 0,12 0,24 0,37 Minimum Airflow *2 m 3 /h 1.350 1.800 2.500 2.350 3.250 4.350 3.700 5.300 6.900 5.200 6.900 9.850 Max Pressure *3 800 800 800 800 Max Air Temperature *4 120 120 120 120 Model G07980 G08080 G08180 G08280 Type of Appliance B23 Ec Approval 0694BP0758 Nox Class 4-5 with Gas Burner LOW NOx min >91% max min >91% max min >91% max min >91% max Furnace Heat Input KW 115 202,5 230,0 154,0 252,0 310,0 185,0 309,0 380,0 260 398 508 Useful Heat KW 108,1 184,7 205,9 145,0 230,2 275,0 173,9 282,1 335,9 245 364 450 Combustion Efficiency % 94,0 91,2 89,5 94,0 91,3 88,7 94,0 91,3 87,7 94,4 91,5 88,6 Chimney Loss - Burner On % 6,0 8,8 10,5 6,0 8,7 12,3 6,0 8,7 12,3 5,6 8,5 11,4 Chimney Loss - Burner Off % <0,1 <0,1 < 0,1 < 0,1 Casing Losses % 1,16 1,17 1,02 1,03 Furnace Pressure Pa 10 32 40 10 36 50 15 45 60 28 85 120 Furnace Volume m 3 0,52 0,76 1,06 1,55 Minimum Airflow *2 m 3 /h 6.200 10.600 11.850 8.350 13.200 15.800 10.000 16.200 19.300 14.050 20.900 25.800 Max Pressure *3 Pa 800 800 800 800 Max Air Temperature *4 C 120 120 120 120 Notes: 1) Efficiency - The efficiency rate is obtained with air flow rates at t of 35 K with inlet air temperature at 15 C. For different applications, ask our technical dipartment. 2) Minimum air flow rate - Minimum air flow rate has been calculated for a t value of 50 K, suitable for process plants or special applications. For more demanding requirements, where t > 50 K, see further information on efficiency levels. 3) MAX pressure - Max pressure is valid for models coded as G0xxxx and G0xxxx-TF; for models with G0xxxx-2 and Gxxxx-310 coding, max pressure is 2.500 Pa. 4) Air MAX temperature - It is valid for all models but G0xxxx-310, whose max value is 270 C. 8

G0 / Technical Data Model G083080 G08480 G08580 G08680 Type of Appliance B23 Ec Approval 0694BP0758 Nox Class 4-5 with Gas Burner LOW NOx min >91% max min >91% max min >91% max min >91% max Furnace Heat Input KW 320 515 670 397 677 818 447 865 1028 617 865 1170 Useful Heat KW 301 471 592 374 619 730 422 792 920 583,7 792 1049,5 Combustion Efficiency % 94,3 91,5 88,4 94,3 91,4 89,3 94,4 91,6 89,5 94,6 91,6 89,7 Chimney Loss - Burner On % 5,7 8,5 11,6 5,7 8,6 10,7 5,6 8,4 10,5 5,6 8,4 10,5 Chimney Loss - Burner Off % < 0,1 < 0,1 < 0,1 < 0,1 Casing Losses % 0,97 1,00 1,01 1,01 Furnace Pressure Pa 21 80 110 25 92 120 28 98 130 53 154 205 Furnace Volume m 3 1,79 4,78 5,58 5,58 Minimum Airflow *2 m 3 /h 17.300 27.050 33.950 21.450 35.500 41.900 24.200 45.450 52.750 24.200 45.450 52.750 Max Pressure *3 Pa 800 800 800 800 Max Air Temperature *4 C 120 120 120 120 Notes: 1) Efficiency - The efficiency rate is obtained with air flow rates at t of 35 K with inlet air temperature at 15 C. For different applications, ask our technical dipartment. 2) Minimum air flow rate - Minimum air flow rate has been calculated for a t value of 50 K, suitable for process plants or special applications. For more demanding requirements, where t > 50 K, see further information on efficiency levels. 3) MAX pressure - Max pressure is valid for models coded as G0xxxx and G0xxxx-TF; for models with G0xxxx-2 and Gxxxx-310 coding, max pressure is 2.500 Pa. 4) Air MAX temperature - It is valid for all models but G0xxxx-310, whose max value is 270 C. 9

G0 / Dimensioni OC H2 H4 H3 OF L2 L L1 B H1 MODEL Size Chimney Weight TF series L* B H ØF ØC H1 H2 L1 Kg H3 H4 L2 G07580 660 400 710 270 120 170 350 115 40 294 215 140 G07680 940 515 815 468 150 165 480 83 50 200 222 140 G07780 1000 665 980 620 180 250 575 130 80 280 300 140 G07880 1230 750 1070 680 180 260 650 160 110 370 300 140 G07980 1400 870 1205 785 250 275 770 202 130 385 400 140 G08080 1625 910 1340 865 250 290 860 220 177 390 400 140 G08180 1850 955 1340 865 250 290 860 220 195 400 400 140 G08280 2060 1150 1560 1060 300 335 1040 210 264 405 405 140 G08380 2380 1150 1620 1060 300 335 1070 300 376 415 405 140 G08480 2755 1355 1940 1280 350 435 1270 355 520 450 450 140 G08580** 3130 1480 2155 1455 400 495 1375 550 610 500 500 140 * Thickness of gaskets and burner plate is not included in L value (overall dimensions). ** In G08580 model, L value refers to the distance between combustion chamber bottom and burner fitting. In fact, unlike in other models, in G08580 model the combustion chamber protrudes beyond flue hood on the back. Note: the diameter of the chimney is intended as nominal diameter; the fireplace is provided as a female attachment, the inner diameter is 3 mm larger than the nominal diameter, for example the nominal diameter of 250 mm corresponds to an internal diameter of 253 mm. 10

G0 / Dimensioni L L1 CH CV OF H2 H H1 MODEL Size B TF series L* B H ØF H1 H2 L1 CH CV G07580-310 760 400 710 270 170 350 200 120 120 G07680-310 1040 515 815 468 165 480 200 150 150 G07780-310 1100 665 980 620 250 575 200 180 180 G07880-310 1330 750 1070 680 260 650 200 210 210 G07980-310 1500 870 1205 785 275 770 200 210 210 G08080-310 1725 910 1340 865 290 860 200 250 250 G08180-310 1950 955 1340 865 290 860 200 250 250 G08280-310 2160 1150 1560 1060 335 1040 200 300 300 G08380-310 2480 1150 1620 1060 335 1070 200 300 300 G08480-310 2855 1330 1940 1280 435 1270 200 400 250 G08580-310** 3230 1480 2155 1455 495 1375 200 400 250 * Thickness of gaskets and burner plate is not included in L value (overall dimensions). ** In G08580-310 model, L value refers to the distance between furnace bottom and burner fitting. In fact, unlike in other models, in G08580 model the furnace protrudes beyond flue hood on the back. 11

www.apengroup.com APEN GROUP S.p.A. 20060 Pessano con Bornago (MI) - Italy Via Isonzo, 1 (ex Via Provinciale, 85) Phone +39-02-95.96.93.1 Fax +39-02-95.74.27.58 www.apengroup.com apen@apengroup.com Specifications in this catalogue are subject to change without notice.