State University of New York College at Oneonta Contingency Plan for Incidents Involving Hazardous Materials and Waste

Similar documents
State University of New York College at Oneonta Contingency Plan for Incidents Involving Hazardous Materials and Waste

Contingency Plan for Hazardous Materials and Waste Releases

This plan, its contents, and emergency notification procedures shall be made available to all appropriate university employees.

IYRS School of Technology & Trades RCRA CONTINGENCY PLAN Bristol Facility 40 CFR 265 Subpart D 29 CFR Emergency Evacuation

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Hazardous Materials Protection and Contingency Plan for Carnegie Mellon University Doha Campus

HAZARDOUS WASTE CONTINGENCY PLAN

ANGELO STATE UNIVERSITY HAZARDOUS CHEMICAL STORAGE & SPILL CONTINGENCY PLAN

5.0 CONTINGENCY PLAN. It is necessary to amend the plan if:

WESTERN CONNECTICUT STATE UNIVERSITY HAZARDOUS WASTE CONTINGENCY PLAN PROCEDURE E-115

SPILL PREVENTION AND RESPONSE PLAN

These telephone numbers are provided as a general aid to emergency notification. Be advised that additional agencies may be required to be notified.

Application: Response procedures for major and minor spills, including: organic solvents acids bases dry chemicals mercury hydrofluoric acid

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

Fire Prevention and Protection Plan

Emergency Evacuation Plan. Kettering Labs. School of Engineering

Evacuation Fire Safety Program

Contingency Plan Dangerous Waste WAC

Emergency Action Plan for

FIRE PREVENTION PLAN EMERGENCY ACTION

Emergency Action Plan For Alumni Center 1507 Dana Avenue

Office of Research Safety Laboratory Safety Manual 215 Chemical Spill Response

Harvard University - OEB Glasshouse Emergency Evacuation Plan

Alfred University. Emergency Response Plan for Hazardous Materials Release

Emergency Evacuation Plan South Patterson Building (SPB)

Emergency Action Fire Prevention Plan

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Contingency Planning for the Household Hazardous Waste Facility

Kaufert Laboratory Building Emergency Plan

Emergency Action Plan for Sycamore House 3818 Winding Way

Xavier Field Office Emergency Action Plan. For. Xavier Field Office Dana Avenue

EMERGENCY RESPONSE PLAN

Department of Veterinary Medicine

Emergency Guidelines Part II. North Campus

General Safety Training

Research and Graduate Studies Department. Policy Number: 215 Laboratory Safety Date: 1/12/2001 Supersedes: New Chemical Spill Response Page: 1 of 11

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Emergency Preparedness Guide

SAFE WORK PROCEDURE. List the Hazards and risk controls as per risk assessment. assessment reference:

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

Emergency Evacuation Procedures

General Safety Training

El Segundo Fire Department. Unified Program (UP) Form CONSOLIDATED CONTINGENCY PLAN I. FACILITY IDENTIFICATION

School EMERGENCY PLAN

University of Pittsburgh. Scaife Hall 3550 Terrace Street Occupant Information

Emergency. Quick Reference Guide

Emergency Action Plan. Revised: 1/22/2018

EMERGENCY PREPAREDNESS: EVACUATIONS

Emergency Notification Plan. Developed By: Cleveland State University Police Department Office of Emergency Management

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

BUILDING EMERGENCY ACTION PLAN. for Your Building Name

Emergency Response Cart Guide

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Moe Pond Dam Emergency Action Plan

EMERGENCY LOCK DOWN PROCEDURE

Protocol for Chemical Spills. By Gordon Krueger Environmental Safety Specialist University of Northern Iowa Environmental Health and Safety

DUNCAN STUDENT CENTER. Emergency Action Plan

LAKE COUNTY SCHOOL DISTRICT

SCALES NW EMERGENCY ACTION PLAN

Board Policy 6819 Fire Safety and Prevention Plan

This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials.

EMERGENCY PROCEDURES FOR WCSD SCHOOLS AND SITES

Pesticide Emergencies: Contingency Planning 1

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Department of Chemistry Emergency Action Plan

Sam Houston State University Emergency Protocol Quick Reference Guide

Emergency Procedures Protocol

Each department is responsible for determining shutdown procedures for equipment consistent with common safety practices.

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

CAMPUS EMERGENCIES CAMPUS EMERGENCIES WHAT TO DO IN THE EVENT OF A CAMPUS EMERGENCY

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

Emergency Plan. Chemistry and Chemical Biology. Clark Hall Building 22. Revision 1 January

Emergency or Incident Response

RCRA Emergency/Contingency Plan

Haecker Hall Building Emergency Plan

CHEMICAL HYGIENE PLAN (CHP)

The Overfield School Emergency Plan

Emergency Action Plan Program

University of Maryland FIRE EVACUATION PLAN

The University of Washington Nanofabrication Facility (WNF) at Fluke Hall 125 Fluke Hall Seattle, WA 98195

I. PREPAREDNESS, PREVENTION, AND CONTINGENCY SECTION

WESTCHESTER PUBLIC LIBRARY EMERGENCY POLICY. Revised January 12, 2017

2.1 WHAT TO DO IN THE EVENT OF AN ACCIDENT OR EMERGENCY

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

VICI. Emergency Evacuation Plan

FIRE EMERGENCY POLICY

MIT Emergency Response Guide

EMERGENCY TELEPHONE NUMBERS

Emergency Guidebook WEAPONS ON CAMPUS ACTIVE SHOOTER BOMB THREAT FIRE / EXPLOSION CRIME REPORTING EVACUATION HAZMAT SPILL HIGHWAY HOSTAGE SITUATION

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Liberal Arts and Humanities. Building # 275. Emergency Evacuation Plan

HUDSON VALLEY COMMUNITY COLLEGE BUILDING EMERGENCY ACTION PLAN FOR OUTSIDE EMERGENCY ASSISTANCE: DIAL 911 TO REACH THE SARATOGA CTY POLICE & FIRE

Alpha: Cindy Avitia High School School Safety Plan (Updated August 13, 2018)

Chemical Spill Control

4. The Whitman College Chemical Hygiene Officer is Fred Miller, Manager, Environmental Health and Safety.

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

Emergency Response Guide for Laboratories

Campus Emergency Response Plan Standard Operating Procedure

Transcription:

Facilities and Safety 322 West Street State University of New York Oneonta, New York 13820-4015 (607) 436-3224 Fax: (607) 436-2568 State University of New York College at Oneonta Contingency Plan for Incidents Involving Hazardous Materials and Waste In order to reduce hazards to employees and property in the event there is an incident involving hazardous waste materials on campus, the College at Oneonta has developed the following contingency plan. Scope of the Plan This plan will be implemented if a fire, explosion, or release of hazardous waste which threatens public health or the environment occurs at the College at Oneonta. Emergency Response Actions When a hazardous chemical spill, leak or fire is noticed by anyone, first call University Police. If it is in a classroom the professor in charge of the classroom should be notified. If this is not possible, the chairman of the chemistry department will be notified. If the spill is not in a classroom University Police will notify Facilities. If the spill or leak is deemed serious, the appropriate floor or the building itself will be evacuated. This will be accomplished by activating the fire alarm system, or picking up any of the red phones in the hallway near the labs or storage area. A professor can evacuate a classroom or the entire building as deemed necessary. The Red Phone phones are a direct connection to University Police and are tested annually by University Police while doing the Blue Phone checks. 1. If possible, shut off any sources of ignition and/or the source of the spill without endangering yourself. 2. Evacuate the immediate area, closing the doors behind you (unless there is a natural gas leak). 3. Proceed to the nearest available exit by following exit signs. 4. Call the University Police at 3550 they are staffed 24/7. Be prepared to provide the following information: Your name, the specific location of the spill, the name of the substance spilled, and the quantity spilled. 5. Do not return for any reason once you are clear of the building

6. Wait outdoors for University Police and/or the Facilities and Safety Department or Radiation Safety Officer to arrive, and identify yourself to them. The University Police representative in charge will notify the Oneonta Fire Department and/or Police Department if necessary. University Police will call Tom Rathbone and Norman Payne at 436-3224. Upon arrival, the University Police representative must determine whether or not the imminent or actual incident could threaten human health or the environment. Next, it will be determined whether the incident will be contained within the building, with the perimeter of the college campus or will have any affect outside the perimeter of the college. The college office of Facilities and Safety will act as response coordinators: Primary Coordinator: Secondary Coordinator: Norm Payne Asst. Dir Facilities and Safety 131 Angel Drive, Oneonta, NY 13820 Office 436-2021; Home - 432-1856; Cell - 434-5941 Tom Rathbone AVP Facilities Rte 35, Maryland, NY 12116 Office 436-3224; Home - 607-286-9415; Cell - 435-121 Even when it is determined that the incident will be contained within the college s boundaries or the quantity released is below the reporting threshold, the Oneonta Fire Department will be notified as soon as possible. Oneonta Fire Department 432-2222 If the incident has the potential to go outside the College s boundaries, then the following notifications might be made as determined by the Director of Facilities Otsego County Emergency Services 547-4225 Fox Hospital 431-5000 New York State Spill Hotline 1-800-457-7362 (Alternate) 1-800-457-2200 National Response Center 1-800-424-8802 The following information should be provided: name and telephone number of reporter; name and address of facility; time and type of incident (e.g., release, fire); name and quantity of materials(s) involved, to the extent known; the extent of injuries, if any; and the possible hazards to human health, or the environment, outside the facility. Direction and Control University Police offices in Alumni Hall will serve as a command post for all emergencies on the site. 2

Containment During an emergency, the coordinator must take all reasonable measures necessary to ensure that fires, explosions, and releases do not occur, recur, or spread to other hazardous waste at the facility. These measures must include, where applicable, stopping processes and operations, collecting and containing released waste, and removing or isolating containers After the notification of a release shall be to control or stop the release of the hazardous material from the premises. Spill equipment is located in the Heating Plant above the tool room. Spedi Dri ( a clay based absorbent) is located in the Biology Outside Hazardous waste storage area, the Garage and the Grounds building. This can be used to stop the spread of most hazardous spills. Safety Data Sheets for the chemicals are available on-line using a link from the facilities web page (on campus only). Specific procedures regarding first aid, spill/leak procedures, fires, explosions, toxicity, personal protection, environmental effects, and transportation are outlined for each chemical in the manufacturer s Safety Data Sheet. The Facilities director may elect to contract removal services from a licensed chemical disposal company. Contact any one of the following companies: Clean Harbors 518-434-0149 Environmental Products & Svc 518-465-4000 Safety Kleen 520-783-1068 Suppression Appropriate fire extinguishers are provided proximate to hazardous material handling locations. In addition, the following suppression systems exist. The extinguishers are checked monthly by a representative from University Police. The following are locations/ size and type of fire suppression equipment: Science II: Off line Human Ecology: Outside Connex box- just inside the door 5 lb CO2 MOC: Paint shop- on wall by 55 gallon drum 5 lb CO2 On wall outside paint shop 10 lb ABC Biology Outside Volatile Storage area: 5lb CO2 inside the door in cabinet. Also inside loading dock door Fine Arts: Oil Painting Studio 320 on right wall as you walk in/ 10 lb/ ABC Campus Evacuation In the event that you are notified by text, or voicemail to evacuate the campus due to an emergency, the primary evacuation route for emergencies on campus will be down Ravine Parkway to West Street. The secondary evacuation route for emergencies is down Bugbee road to East street, the alternate route is to travel up Bugbee road, past the maintenance operations center to West Street. The siren on top of the Milne Library means to shelter in place- do not evacuate when you hear this. 3

Emergency Spill Equipment Absorbent pads and booms are located in the Heating Plant above the tool room. The Heat Plant is staffed 24 hours a day allowing access to them. Quantity Type of Equipment Location 12 Skum Skimmer Heating Plant Loft 1 Recycled Cloth 25lb box Heating Plant Loft 250 15 x19 oil pads Heating Plant Loft 20 Blue sock 8 dia by 10 length Heating Plant Loft 70 White Sock 4 dia by 10 length Heating Plant Loft 70 Spill Control Pillows Heating Plant Loft 1 Spill Berm: 10ft straight section Heating Plant Loft 2 Spill Berm: 90 degree bend Heating Plant Loft 11 Oil Dri 40lb bag Heating Plant Loft 7 Fyber Soak 55lb Container Heating Plant Loft A mercury vacuum is located in the back HUEC. This specialized vacuum is to be used for clean up when a thermometer is broken that contained mercury. There are still some labs that require the use of mercury thermometers due to temperatures. The use of these thermometers are limited. A small chemical spill kit is located in HUEC 228 under the fume hood. This kit is to be used to contain small lab spills after consulting with the professor in direct supervision of the lab to determine the product spilled and the amount, Use the Safety Data Sheet to determine the proper protective equipment. The contents of this 5 gallon pail are: StarDust all purpose absorbent, Acid neutralizer, Base neutralizer, Mercury absorbent, Gloves, Plastic bag, MSDS for Stardust. After the Incident Immediately after an emergency, the emergency coordinator must provide for treating, storing, or disposing of recovered waste, contaminated soil or surface water, or any other material that results from a release, fire, or explosion at the facility. The emergency coordinator must ensure that, in the affected area(s) of the facility; that no waste that may be incompatible with the released material is treated, stored, or disposed of until cleanup procedures are completed; and that all emergency equipment listed in the contingency plan is cleaned and fit for its intended use before operations are resumed. The emergency coordinator must notify the commissioner, and appropriate State and local authorities, that the facility is in compliance with paragraph (8) of this subdivision before operations are resumed in the affected area(s) of the facility. Whenever this plan is used, a record must be kept of the time, date, and details of any incident that requires implementing the contingency plan. Within 15 days after the incident, a written report on the incident must be submitted to the commissioner. The report must include: name, address, and telephone number of the owner or operator; name, address, and telephone number of the facility; date, time, and type of incident (e.g., fire, explosion); 4

name and quantity of material(s) involved; the extent of injuries, if any; an assessment of actual or potential hazards to human health or the environment, where this is applicable; and an estimated quantity and disposition of recovered material that resulted from the incident. Reviewed: March 2012 January 2014 February 2015 January 2016 Additional information for the Hazardous Waste book: Job title for each position at the facility related to hazardous waste management and name of employee filling each job: Job title: Assistant Director of Facilities and Safety Employee: Norman Payne The Assistant Director of Facilities and Safety oversees the collection and removal of hazardous waste from the campus; contracts with vendors authorized to accept hazardous waste; submits annual reports to DEC as required on or before March 1 of each year; trains campus personnel in the proper procedures for handling hazardous waste, universal waste and aerosols, as well as the procedures for cleaning or reporting a hazardous waste spill. The Assistant Director of Facilities and Safety will attend training as follows: Hazardous Waste training every year per 40 CFR 265.16.and DOT Hazardous Material Shipping is every 3 yrs per 49 CFR 171.8. 5