CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Similar documents
ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

THERMAL RADIATORS INSTALLATION INSTRUCTIONS AND USER GUIDE RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E

INGENIUM INGENIUM INGENIUM. or using this appliance for the first time.

NIGHT STORAGE HEATERS

ELECTRIC DESIGNER RADIATORS

200W Frostwatch Radiant Heater Operation Manual

instructions OIL FILLED RADIATOR V V and V551225

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

Instruction Manual. OLSBERG High-line heater

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

3KW ELECTRIC FAN HEATER

INSTALLATION & USER INSTRUCTIONS

Combined Storage and Fan Heater

2.8KW ELECTRIC FAN HEATER

How to install and use your storage heater

OPERATING INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

WALL MOUNTED ELECTRIC FIREPLACE (heat blowing from the front series)

DIGITAL MODULATING BOILERS

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Imperial Electric Fires

Imperial Electric Fires

MICATHERMIC PANEL HEATER

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

TSR Electric Storage Heaters

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

5KW ELECTRIC FAN HEATER

MHG201 Gas Hob Manual for Installation, Use and Maintenance

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

HAVERLAND APP. The first self-programmable radiator and control from anywhere in the world INSTRUCTION MANUAL.

Oil Panel Heater Instructions for Use

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Glass Kettle. Pour la version française veuillez consulter notre site de web

INSTALLATION & USER INSTRUCTIONS

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

INSTRUCTION MANUAL. This product is only suitable for well insulated spaces or occasional use.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Oil Filled Radiator. Model: SH60010 (all colours) Help line: This product is only suitable for well insulated spaces or occasional use

15KW ELECTRIC FAN HEATER

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Use & Care Manual Contemporary Electric Fires

INSTRUCTIONS AND WARRANTY

PH1000T PH1500T PH2000T

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

30KW ELECTRIC FAN HEATER

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Portable Electric Patio Heater User's manual

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

OPERATING INSTRUCTIONS

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

JUNEAU JUN. 08/51193/0 Issue 0

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

Installation and Maintenance Instructions XPG170 Electric Fires

Electric Cooker. Important Please read these instructions fully before installing or using

Instructions Manual CTB CTB 9407

Operating and installation instructions

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

ECOLEC PANEL HEATERS GENERAL NOTES.

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

OPERATING & MAINTENANCE INSTRUCTIONS

User and maintenance manual

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance


MeacoDry ABC Range Dehumidifiers

EVG Extractors. Manual for Installation, Use and Maintenance

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

ECHK90 & ECPK90 Extractors Manual for Installation, Use and Maintenance

FIGARO. 08/52543/0 (UK) Issue 1

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

INSTALLATION & USER INSTRUCTIONS

EN Instruction on mounting and use

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

INSTALLATION & USER INSTRUCTIONS

ST E /ST E / ST E / ST E ST E / ST E / ST E

Electric Cooker. Important Please read these instructions fully before installing or using

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Electric Cooker. Important Please read these instructions fully before installing or using

Lumiglo Fast Boil Kettle

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLATION & USER INSTRUCTIONS

CERAMIC FAN HEATER URBAN

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Use & Care Manual Inset Electric Fires

Transcription:

INSTALLATION INSTRUCTIONS AND USER GUIDE CSH COMBINED STORAGE HEATERS CSH12 CSH18 CSH24 CSH12A CSH18A CSH24A Please read these instructionscarefullybefore installing or using this appliance for the first time.

1. WARNING Please read these instructions before installing or using this appliance for the first time. The warranty of the combined storage heater will not cover any damage caused by non observance of any of these instructions. This Guide must be kept and given to any new owner. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be made by children without supervision. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. Neither the connecting cable nor any other object must come into contact with the hot unit. Check that the voltage shown on the rating plate on the heater is the same as the voltage of the supply to which connection is to be made. WARNING: In order to avoid overheating, do not cover the heater. Do not use this heater to dry clothes. Do not place objects in contact with the heater. The installation of the heater should be carried out by qualified electricians. Should the heater be moved and reinstalled it is essential that the work is carried out by qualified electricians. Never open a charged heater. If during any reinstallation the thermal insulation shows any sign of damage, it is necessary for the faulty part to be removed and replaced by an identical part. The use of storage heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. The air outlet grill at the top of the heater cabinet and the air inlet at the bottom of the heater are provided to ensure the most efficient operation of the appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered. This heater should be switched off at the isolating switch before any repair work is carried out. This action should also be taken during the times of the year when heat is not required. The installation of the heaters must be carried out in such a way that each pole can be disconnected from the supply having a contact separation of at least 3 mm. The storage heater should not be installed just below an electrical socket. The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls. This appliance must be earthed. The nominal charging time of this storage heater must be controlled by means of a programmer. The installation must be carried out in accordance with the current electrical regulations. After installation a survey of the first charging cycle should be carried out to ensure that the main input thermostat switches off. Ventilate the room during this first cycle. Before carrying out any work inside the appliance, the heater must be disconnected from the electricity supply. The presence in the air of particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater. To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater. EN: WARNING: In order to avoid overheating do not cover the heater. 1

2. INTRODUCTION Storage heaters are designed to take advantage of the considerable economical benefits of any restricted hour electricity tariff. These heaters consume electricity only during the night, but due to the highly efficient storage medium, give you a truly economical 24 hours of comfort temperatures. Model Voltage V Input kw Convector kw Max. Hours ON Charge kwh Bricks Weight kg CSH12 230/240 1.6/1.7 0.9/1.0 8 / 7 12.8 /11.9 8 80 54 18.5 73 CSH18 230/240 2.4/2.55 1.4/1.5 8 / 7 19.2/17.85 12 117 76.5 18.5 73 CSH24 230/240 3.2/3.4 1.6/1.75 8 / 7 25.6/23.8 16 154 99 18.5 73 CSH12A 230/240 1.6/1.7 0.9/1.0 8 / 7 12.8 /11.9 8 80 54 18.5 73 CSH18A 230/240 2.4/2.55 1.4/1.5 8 / 7 19.2/17.85 12 117 76.5 18.5 73 CSH24A 230/240 3.2/3.4 1.6/1.75 8 / 7 25.6/23.8 16 154 99 18.5 73 L cm W cm H cm The input control operates a highly sensitive thermostat which regulates the amount of heat stored. The discharge is by convection heat which can be partially controlled by use of the output control. It is important that the correct rating of heater is installed to provide the selected level of heat. This will ensure the best possible running costs against other fuels. To reduce transport problems, the heater casings and storage bricks are packed separately. The bricks are packed in sets of two. You should be aware that Storage heaters, when fully charged, can have high surface temperatures. 3. INSTALLING THE COMBINED STORAGE HEATER 1. Chose the right place to install the heater. It is necessary that a minimum clearance of 50 cm is allowed to ensure the best heating results. Always maintain a minimum clearance of 50 cm from the heater to any combustible materials such as furniture and curtains. 2. Open the carton at the indicated side and fix the feet (Fig.1) without removing the heater casing. The screws are in the accessories bag. Turn the carton upside down to allow the heater to stand on its feet and remove the carton. Check that it is the correct model and that it is in good condition. Fig.1 2

3. Take off the front panel by removing the two screws at the bottom of the heater. 4. Set the heater in the selected installation area and mark the fixing points on the wall using a pencil. Use the heater fixing holes as a template and mark the wall through the fixing holes. 5. Drill the required holes into the wall. 6. Fix the heater to the wall. Please note the weight of the heater is taken by the feet, the wall fixing screws are only to prevent the heater overturning. If there is any doubt as to the strength of the wall please consult an expert. Storage heaters are very heavy and the installer must ensure that they are securely fixed and that there is no possibility of them overturning. 7. Connect the heater using the enclosed wiring diagram. Ensure that all connections are firm. The restricted supply leads must be connected to a supply controlled by means of a programmer. The unrestricted supply leads must be connected to a 24 hours supply. Use silicone covered wire. Fig.2 Do not leave any remaining wire inside the heater. Do not connect the convector element yet. 8. Remove the inner front panel with the attached convector element. WARNING: At the other side of this front panel there is a breakable thermal insulation panel. Both sides must be handled with care. Avoid touching the insulation and the convector element. 9. Do not disconnect the electrical elements. Remove the packaging then lift and recline the elements. 3

10. Place the storage bricks carefully, with the flat side facing the back of the heater. Arrange two rows of bricks (Fig.3). 11. Fix the elements in their original position. Place the other two rows of bricks with the knobs face to face. Fig.3 12. Refit the inner front panel. If the bricks have been fitted correctly you will find no difficulty in refitting the panel (Fig.4). 13. Connect the convector element using the two free fast-on terminals. Follow the enclosed diagram. Fig.4 14. Attach the front panel and fix it at the bottom edge with the two screws provided. 4

4. USING THE COMBINED STORAGE HEATER The two controls at the right top of the heater govern the input and output functions of the storage heater. Both are printed with the numbers 1 to 5. Fig.5 The input control allows you to select the amount of heat you wish to store during the night. During mild weather, it is normal to set your input control in a medium position. In cooler weather, the control could be set at 5 to give maximum heat retention. The stored heat will be delivered to the room by both radiant and convection methods. The convection heat can be regulated by using the output control. This control governs the continuous flow of convection heat from the outlet grill. All combined storage heaters have an exclusive feature which makes it unnecessary to close the output control at night. The outlet grill will close automatically at the beginning of the overnight charge 5. USING THE CONVECTOR Switch on the convector by setting the switch placed at the lower left side of the heater marked is marked 0. When the convector is generating heat, the neon indicator on the switch will be illuminated. o to -. The off position The convector is fitted with an adjustable thermostat, which enables room temperature to be controlled by adjusting the setting accordingly when the convector is on. Turn the thermostat control to the maximum (fully clockwise) and when the desired temperature has been reached, turn the thermostat slowly to the left (counter clockwise) until the luminous indicator switches off. By leaving in this position, the heater will automatically maintain the selected temperature. It is recommended to switch off the convector at the beginning of the overnight charge. IMPORTANT for models CSH12A, CSH18A and CSH24A The direct acting convector element should be switched off prior to the storage heaters night time charge period engaging. This is to avoid the possibility of the automatic charge regulator reducing the total charge taken, due to it reading a high room temperature. 6. MAINTENANCE OF YOUR COMBINED STORE HEATER This storage heater does not require any special care. During the first few charges you may be aware of an unusual odour. This is normal and if it happens please ventilate the room until the odour disappears. If dust accumulates on the heater surface it can be removed using a wet cloth when the heater is cold. Do not use solvents or abrasive products. 5

7. WIRING DIAGRAMS R1, R2, R3, R4... Heating elements CE... Convector element with built in thermal cut out RAC... Accelerating resistance C... Switch Tc... Charge control thermostat PE... Earth Ts... Safety cut out L... Phase Ta... Ambient thermostat N... Neutral R1, R2, R3, R4... Heating elements CE... Convector element with built in thermal cut out RAC... Accelerating resistance C... Switch Tc... Charge control thermostat PE... Earth Ts... Safety cut out L... Phase Tl... Temperature limiter N... Neutral Ta... Ambient thermostat IMPORTANT This equipment is supplied with a main connector. All the wires must be coloured in accordance with the following code: Green & Yellow Earth Blue Neutral Brown - Live 6

The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. These instructions are only valid in the EU member states. Supplier: ELNUR UK Ltd. Telephone +44(0)1942 670119 www.elnur.co.uk info@elnur.co.uk Manufactured by: ELNUR S.A. Travesía de Villa Esther, 11 28110, ALGETE Madrid Telephone +34 916281440 As part of the policy of continuous product improvement the manufacturer reserves the right to alter specifications without notice. 10299150 R1