AIS750 Series Alarm Annunciator

Similar documents
AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

SIL725 Safety Annunciator

Series 725 Programmable Alarm Annunciator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

DRAFT 20 October 2014

X11CA COMPUTER ANNUNCIATORS

System 9000TS Sequence of Events Recorder

Model A1700 Series Annunciator

AN-3100D Annunciator

Model A1600 Series Annunciator

Model A2100 Series Annunciator

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Complex alarming made simple

System 9000TS Sequence of Events Recorder

On the job around the clock 24/7: Fire detection systems

Annunciator Unit SACO 16 D1. Product Guide

Two-Channel Gas Controller

Annunciator unit. Application

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

21-light Remote Annunciator. Owner s Manual

ME 3011C / Alarm Indication / Quick Reference Guide

PolyGard 2-channel Gas Controller MGC-03

ESP TECHNOLOGIES LIMITED

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

X16PDM P R O G RAMMABLE

Control and Annunciator Panels. Compact systems of signalling and control

4 & 8-POINT ANNUNCIATORS Instruction Manual

Variable Frequency Drive SERIES MP800 VFD

Carbon Monoxide Transmitter

Across-the-Line SERIES MP300 Combined Manual and Automatic

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Soft Start Series MP700 Solid State, Reduced Voltage

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

725 Series Alarm Annunciator Rev 24. RTK Series 725 Annunciator

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

725B Configuration Software Manual

System 9000TS Event Recorder

Annuciator Logic Controllers

ESSEX ENGINEERING CORPORATION

Panel Mounted Fault Annunciator Series

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Universal fault annunciator for panel mounting

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

USER MANUAL FOR OPERATING SYSTEM

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

AO Annunciator Module

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

20 Light Remote Annunciator

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Technical data MTL process alarm equipment. September 2016 INM RTK725 range rev 30. MTL RTK725 range. Alarm Annunciator

Window facia fault annunciators

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

CLEANROOM MONITOR CR3A Network - Installation Instructions

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANEL

Panel Mounted Fault Annunciator Series

CTT8 TEMPERATURE MONITOR DEVICE

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

MO n : 12JMC rév A

Commercial and Light Industrial Fire Alarm Control Panel

M1000 Alarm Annunciator

I/A Series 716C 1/16 DIN Temperature Controller

Analog Annunciator Unit SACO 16 A3. Product Guide

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

PTE0705 Electric Fence Monitor

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

IF-L/RF Protection Switch

ACTIVE INFRARED BARRIER

MODEL DESCRIPTION PAGE

PowerLogic Branch Circuit Power Meter (BCPM)

NU2 Smart Power Supply (SPS) Manual

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

SmartAlarm Annunciator

NETWORK FIRE ALARM CONTROL PANEL. Features

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

APPLICATION DATA SHEET

Multi-Gas-Controller MGC2

Gas Controller Module GC-06

Oxygen (O2) Single-Point Gas Detection System

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

M2500 Engine Controller Installation Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Sequence of operation

Honeywell SLATE ICM Platform

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

SEL-2523 Advanced Annunciator Panel

HRX Technical Manual. Version 1.2

Transcription:

Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual & software fi eld confi gurable Full function, fl exible and reliable Alarm sequence to ISA-S18.1 Five different cell sizes Nine different output types Optional bi-colour windows Individual channel Repeat Relay Shallow installed depth (145mm) Integral or remote control pushbuttons Backlit Illumination by LED modules in different colours Field selectable Input setting (NC or NO, Dry Contact or Voltage) AIS750 Cat V1.0 Master RS485 APEX Automation Solutions Up to 7 Annunciators www.annunciator.ca

Technical Specification General Supply Voltage: Standard system: 12VDC Nominal Also available in 24VDC, 48VDC, 125-250V AC/DC Supply Current Per Alarm Point: Quiescent: 5mA (at 12VDC) LEDs: H11: 24mA (at 12VDC) H21, H12, V21: 12mA (at 12VDC) : 6mA (at 12VDC) Relay: 10mA per relay (at 12VDC) Additional 100mA current is required for Interface Module, Pushbutton/Buzzer Module, Common Relay and Buzzer and Serial Communication Module Environment: Operating temperature: -20 to 60ºC Storage temperature: -20 to 80 C Humidity 0-95% RH, non condensing Protection: Front Panel: IP41 Enclosure: IP20 Optional silicon cover for more protection up to IP65 Weight: Approximately 0.3 kg per H11 window Connection Terminals: - Two-part removable screw type 2 - Maximum wire size: 2.5 mm Operating Mode - Standard (Stand-alone) Mode - Serial Mode (serial communication) System Setup - In Stand-alone Mode: By DIP switches - In Serial Mode: Through ALCON Pushbuttons, Reset, Test and Mute pushbuttons are supported by the system with two choices; Remote and/or Integral pushbuttons Display Confi guration: - One single large window: (H11 type): 75x50mm (WxH) - Two medium window: (H21 type): 75x25mm (WxH) (H12 type): 37.5x50mm (WxH) (V21 type): 50x37.5mm (WxH) - Four small window: ( type): 37.5x25mm (WxH) Number of LED(s) per LED module: 2 Number of LED module per Alarm Point: H11: 4 LED modules H21, H12, V21: 2 LED modules : 1 LED module LED Module Color: - Yellow, Red, Green, White - Bi-color option is available with special order Legends: - Laser Engraved & color fi lled - Printed translucent fi lm Services No special tools are required to replace system modules. Backlit LED Illumination Each window is backlit by an almost unlimited life time plug-in universal LED Modules. Each easy removable LED Module has two 120 high bright LEDs. These LEDs provide Yellow, Red, Green and White bright lights visible even in the most ambient luminescent conditions.

Inputs All inputs are optically isolated. System accepts NO/NC, Dry Contact/Voltage (confi gurable by jumper settings for each alarm point). Option of voltage input from fi eld, PLC or personal computer can be supplied with contact voltages of 24, 48, 125 and 250V (AC or DC). Isolation and Polarity: - Each input is optically isolated up to 2000VAC - All inputs are bipolar and can accept AC or DC voltages Alarm Inputs: - Wet (voltage supplied) or dry (voltage free) contacts. Field Selectable for each individual channel - ly Open (NO) or ly Close (NC). Field Selectable for each individual channel - Dry Contact and 24V(DC or AC) are standard inputs and other voltages are optional as below - Other input Voltages; 48V,125V and 250V (DC or AC) Response Time: - Standard unit: 25ms milliseconds - Made to order from 1ms to 2s Field Selectable Parameters A vast range of system parameters are available to be confi gured by user, such as; alarm sequence, individual input type (dry contact/voltage), alarm group (critical/non critical), repeat relay setting,... There are two options to confi gure these parameters; - By DIP switches (in Stand-alone mode) - Through ALCON software (in Serial mode) Auxiliary Relay (Repeat Relay) Each alarm point can be supplied with an individual repeat relay. The repeat relays can be set to follow Input or Output. NO and NC contacts are available for each repeat relay. Com. Module Logic Card Repeat Relay Module Plug-in LED Modules System Modules System Modules Backplane Modules Interface Module Outputs Supported outputs: - Light Output - Critical Audible Relay - Non-critical Audible Relay - Critical/Non-critical Buzzer - Group Relay - Common Relay - Auxiliary (Repeat) Relay (can be set to follow Input or Output) - Common Alarm Relay - First-up Relay Relay Rating: - 1A@24VDC - 0.5A@ 120VAC Alarm Sequences System supports all ISA-S18.1/1979 (R1985) sequences including: - Manual Reset (M) - Automatic Reset (A) - Automatic Reset First Out (F3A) - Automatic Reset First Out (F1A) - Manual Reset First Out (F2M-1) - Ringback (R) - No Lock In These sequences are Field Selectable for each Alarm Controller. For example for H21 window type, two channels have the same sequence. Multi-drop Connection Multi-drop RS485 communication is available as an option. Up to 7 Annunciators can be connected together and to other devices. Each character represents 8 bit binary data in hexadecimal format. All characters are framed with No Parity bit and one stop bit. Communication AIS750 supports port Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet et and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet, AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open,... Visit www.annunciator.ca for updated specifi cation

Window/Cell Configuration The AIS750 is modular and window based designed. It is manufactured from 75x50mm windows which can be assembled in an array to provide the number of rows and columns required to suit individual panel designs. Each cell within the annunciator is able to contain either; - One single large window (H11 type): 75x50mm (WxH) - Two medium cells: (H21 type): 75x25mm (WxH) (H12 type): 37.5x50mm (WxH) (V21 type): 50x37.5mm (WxH) - Four small cells: ( type): 37.5x25mm (WxH) H11 H12 H12 V21 V21 H21 H21 75mm 37.5mm Calulation of overall and cutout sizes is very easy by using the following formulas: 40mm 20mm 50mm Overall Size Calculation of H11, H21, H12 and : Width (mm)= C x 75 + 37 +_ 0.5 Height (mm)= R x 50 + 37 +_ 0.5 Cutout Size Calculation of H11, H21, H12 and : Width (mm)= C x 75 + 33 +_ 0.5 Height (mm)= R x 50 + 33 +_ 0.5 32.5mm 25mm Overall Size Calculation of V21: Width (mm)= C x 50 + 37 +_ 0.5 Height (mm)= R x 75 + 37 +_ 0.5 65mm Cutout Size Calculation of V21: Width (mm)= C x 50 + 33 +_ 0.5 Height (mm)= R x 75 + 33 +_ 0.5 Visit the below link for Lens Replacement demonstration http://www.youtube.com/watch?v=hfd0d7uofgm C: Number of 75x50mm Windows in one row R: Number of 75x50mm Windows in one column

Alarm Sequences Manual Reset (Sequence Code M) Auto Reset (Sequence Code A) No Lock In to Ak ld Reset S: d to P: S: d to S: d Manual Reset First Out (Sequence F2M-1) Auto Reset First Out (Sequence F3A) Reset Mute S: d Subsequent to S: Subsequent Alarm First to S: First Alarm to S: Subsequent Alarm V: Fast Flashing P: S: Subsequent d Subsequent to First out Reset First to S: First Alarm V: Intermittent Fast Flashing (First-out Reset) Mute (First-out Reset) S: First Silenced First-out Reset S: First d Legends: P: Process S: Sequence V: Visual AA: Alarm Audible RA: Ringback Audible

Alarm Sequences Ring Back (Sequence Code R) Auto Reset First Out (Sequence Code F1A) With No Subsequent Alarm State Reset S: Ringback V: Slow Flashing return A to normal R to A R to P: S: d A R V: Fast Flashing A R to Subsequent to S: d (First-out Reset) (First-out Reset) First to Legends: P: Process S: Sequence V: Visual AA: Alarm Audible RA: Ringback Audible Visit the below links for Manual Reset & Auto Reset demonstrations http://www.youtube.com/watch?v=xgyib4a5poe http://www.youtube.com/watch?v=j7n6rersviq Order Number Model # Number of Windows in a Column (wide) Signal Voltage V0: Dry Contact V1: 24VDC/AC V2: 48VDC/AC V3: 125VDC/AC V4: 250VDC/AC V5: Others (Specify) Pushbutton & Buzzer Module 1: With 0: Without AIS750 03 04 H21 V1 1 N 1 0 Number of Windows in a Row (high) Window type Auxiliary Relay 1: With 0: Without Serial Comm. 1: With 0: Without

Optional Features Integral Pushbutton & Buzzer Module (option) Standard AIS750 Series Annunciator supports four remote Pushbuttons (, Reset, Test, Mute) and two Horns. As an option, an integral Pushbutton & Buzzer Module can be fi tted in the bottom right window. Auxiliary (Repeat) Relay Module (option) Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) which plugs into Logic Card and provides the user with a dry contact (potential free) contact per alarm channel for use with 3rd party devices. These repeat relays can be confi gured to operate in accordance with one of the following. - Input Follower: The relay changes state each time there is a change to the associated signal input contact. - Output (display) Follower: The relay changes state on alarm and faithfully follows the display window. Serial Communication (option) For serial communication with other Annunciators, controllers, computers, devices,... or to operate in Serial mode, a Communication Card (Com. Module) plugs into Interface Module to support RS485 and RS232 networks (selectable). Distributed by: Phone: +1 289 597 APEX(2739) Fax: +1 289 597 2200 Email: mail@annunciator.ca Web: www.apexannunciator.com 3-350 John Street, Thornhill, L3T 5W6, Ontario, Canada