Patient Compartment Light

Similar documents
Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

SUMMARY OF ANTIMICROBIAL ACTIVITY

Add the Power of Indigo-Clean Disinfecting Technology to your Facility Lighting

THE THREATS YOU CAN T SEE. THE DIFFERENCE YOU CAN.

256 Century Q is a no-rinse neutral ph disinfectant cleaner that disinfects and cleans in one labor saving step.

Specialist Cleaning System & Long Lasting Residual Disinfection Solution

Continuous Environmental Disinfection for Surgical Suites. Don t Just Clean... Indigo-Clean. Designed and manufactured in the USA

GERMICIDAL ULTRAVIOLET FIXTURES

GERMICIDAL ULTRAVIOLET IRRADIATORS

CLINI SAFE. The safest choice for Health Care Establishments NEW PRODUCT FEATURES. 5 Cleaning methods. Fire reaction: A1

Intensive UV light means not a chance for germs!

Model D24-1S. Model D24-2S

SBS Design Considerations for Autoclave Sterilization

ONE-STEP DETERGENT DISINFECTANT

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

PACKETS - Open and pour contents into.25 gallons of water (or equivalent dilution). Keep packets in box until ready to use.

Inside your life! LG Innotek's innovative technologies will take you to a safe, convenient and enjoyable future. 7 th, May 2018

The revolutionary single-use system

The Latest Innovations in Hand Washing Technology

A comparative study of different hand drying methods: paper towel, warm air dryer, jet air dryer.

CEILING SYSTEMS. [ Between us, ideas become reality.] Bioguard. The Anti-Bacterial Coating

ULTRAVIOLET PORTABLE AREA SANITIZER

Optional / Ergonomic Accessories for Clean-Air & Containment Cabinets

Ultraviolet PCR Cabinets and Workstations

Model RS72. Model RSCS280A. Model RSM2680

ULTRAVIOLET WATER TREATMENT

HPL and solid grade (Compact) through-colour laminate

ULTRAVIOLET INDIRECT AIR DISINFECTION

Guide To Ozone Laundry Systems

english industrial sanitizing with ecological dry steam

HEPA/UV3 Sterilizing PCR Workstation and Cabinet

Narrow Spectrum Lighting Healthcare, Research and Cleanroom Applications

Cleaning & Sanitising Food processing industry. Replacing synthetic cleaners & sanitisers by natural alternatives

10 Second Machine. 10 Seconds to Better Health Ozone Faucet Systems by Cashido Corporation

SilvaClean Antimicrobial Laundry Additive

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Tru-D Rapid Room Disinfection

Elers Medical Antimicrobial

Introducing the most technically advanced indoor air treatment system

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Filmop A-B PLUS. Anti-Bacterial System

Certified Management System EN ISO EN ISO 9001

GRU-V Air Purifier. Product Manual

SANITIZER Applicable for SFS16, SFS17, SFS18, CP1617, CP1603, CP1605

Perfect Air Purifiers

Bacteria in Household Sponges: A study testing which physical methods are most effective in decontaminating kitchen sponges

UV Irreversible Indicators Product Code: UVI-001

HPL and solid grade (Compact) through-colour laminate

UVDI-360. Get the Facts Straight on UV Disinfection. Room Sanitizer

Integrated Ozone technology based solution For Hospital

intuitive, intelligent, interactive

Installation and Operating Instructions. Rev. 3/24/17. Continuous Antimicrobial Air Cleaner

OZONE DISINFECTION. No other system disinfects laundry more effectively or efficiently

SYSTEM A NEW LEVEL OF CLEAN EXTEND REDUCE OPTIMIZE

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators

Safety Manual Section 15 Radiation Safety

BPICE White Paper Rev_

or

UV measurements for medical applications using SiC photodiodes

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

MagnaWand Cleaning Wand

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

Ultraviolet Air Disinfection Equipment

UVC in the Operating Room.

Purelight XD UV Light Wand. User s Guide

European Tissue Symposium (ETS)

Galaxy Ultra HD-LED Operating Theatre Lights

MODEL NO. UNIT PRICE FOB SIZE UV A 1/2GPM (6 WATT)

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

CLEANING AND DISINFECTANT WIPES

_Sanitizer FS_ _7_8722_.pdf This product contains no phosphorus.

A prescription for efficient building management

Create Clean Air. The specialists in Indoor Air Quality

5. Drain excess liquid and allow to air dry. KEEP OUT OF REACH OF CHILDREN DANGER

Development of Liquid Food Pasteurization Equipment Using Far-infrared Radiation Heating

CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Water Filter. cover. start button. reminder of cartridge replacement. remainder of life of a cartridge it is time to replace a cartridge

Cross Contamination within the Lyndhurst Fire Station. Nicholas Martin Lieutenant Lyndhurst Fire Department 5301 Mayfield Road

In 2013, a lifecycle and cost analysis was conducted in a university setting comparing

Team grup. Risk management during the production of mineral water. Presentation at the 3 rd SAFOODNET seminar. Urban Wiik.

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

safefood for life Quiz

Comfort, Energy & Health Solutions

ULTRAVIOLET SANITARY CONDIT IONERS

DISINFECTING 99.9% KILLS. 1.7 OZ (47 g) Wet Floor Cloth WET MOPPING CLOTHS. Tuscan Lavender & Jasmine KEEP OUT OF REACH OF CHILDREN CAUTION:

What Lies Beneath: The Science Behind Contamination

TEMPORARY FOOD FACILITY RESOURCE GUIDE

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Rugged LED shelter lighting

Instructions for Easygel Method

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

H M H M H M H M H M H M H M B A R R I E R W A S H E R E X T R A C T O R S

Clean Up Safely After a Disaster

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Superior Hygiene and Sanitation Solutions for food processing and food handling professionals

Transcription:

Patient Compartment Light

Always On, Always Protected Bacteria Killing Patient Compartment Light Keeping the patient area of an ambulance clean for each and every patient is critical to keeping the ambulance road ready. Unfortunately, because of the fast-paced nature of the job, and the unexpectedness of each call, bacteria can spread throughout the patient compartment quite easily and frequently. Each time a new person enters the ambulance, new bacteria is introduced and deposited, leading to constant build-up of bacteria on surfaces, especially on high-touch surfaces. Code 3 s Patient Compartment Light powered by Vital Vio s VioSafe Technology provides continuous disinfection of bacteria on objects and surfaces, while providing safe illumination with its precisely engineered wavelengths of visible light. With Code 3 s Patient Compartment Light powered by Vital Vio, continuous disinfection is possible. During calls, in-between calls, or even back at the station, the Patient Compartment Light powered by Vital Vio is continuously working to disinfect and protect all areas that the light is touching. According to the Centers for Disease Control and Prevention (CDC), antibiotic-resistant bacteria infections are associated with two million illnesses and 23,000 deaths in the United States each year. Bacteria lives on surfaces for days, weeks, and in some cases months, they are invisible, can grow exponentially, and are often dangerous to the health of workers and patients. Because current cleaning methods are not continuous, there are large periods of time when workers and patients are susceptible to coming in contact with potentially dangerous germs. Between focusing on the job at hand or traveling to the next call, the patient compartment area of the ambulance may not be entirely disinfected; sometimes spots or areas with harmful bacteria can be missed. Current cleaning methods are found to be inefficient and rarely, if ever, remove 100 percent of the germs on surfaces. Because of this inefficiency, it is important to continuously decrease the amount of bacteria in the vehicle to prevent excessive growth throughout the cabin. With the use of Code 3 s Patient Compartment Light powered by Vital Vio, ambulance providers can dramatically reduce the risk posed to their workers and patients of environmental, or surface contamination by microorganisms. Vital Vio provides continuous disinfection of bacteria on high-touch surfaces and is safe for continuous use around humans.

Safe Reduce Illnesses Great Lighting No Down Time Safe and Certified Code 3 utilizes Vital Vio s VioSafe technology which is safe for humans and animals. The technology has been tested for continuous and unrestricted use around humans. Vital Vio s technology is designed to meet IEC 62471 standards. The IEC 62471 standard gives guidance for evaluating the photobiological safety of lamps, lamp systems and defines exposure limits. User benefits Utilizes proven VioSafe technology to provide continuous disinfection of bacteria on high-touch surfaces in interior environments Requires no special downtime for cleaning as opposed to ultraviolet light methods, making it safe for workers to perform normal course operations while in use Dramatically reduces contamination while providing white light illumination safe for humans and animals that is proven to kill germs Successfully reduces the presence of harmful bacteria and decreases costs associated with illnesses, contamination of goods, and regulatory fines Easily installs and integrates with existing overhead fixtures and meets Triple-K compliancy Vehicle Usage Emergency medical services (EMS) vehicles Search and rescue vehicles Police vehicles Military vehicles Coroner vehicles Prisoner transport vans Crime scene vehicles

How Does It Work? The Science Code 3 s Patient Compartment Light powered by Vital Vio Technology provides surface disinfection in addition to providing white light to illuminate any emergency service response vehicle workspace. Vital Vio s precise spectrum of visible light works to disinfect by initiating a photo-activation of porphyrin molecules found in bacteria, yeast, and fungi. This photo-activation leads to the production of reactive oxygen species (ROS). In high doses, ROS causes irreparable damage to the cellular structure, which leads to bacterial cell death. These activated molecules are unique to bacteria, yeast, and fungi cells, and are not found in human or animal cells, making this spectrum of light safe to be used continuously around humans and animals. Waves of Light ROS Bacteria Cell Dead Cell Activated Molecules STAGE 1 STAGE 2 STAGE 3 STAGE 4 Safety Testing Vital Vio s technology meets all criteria for the IEC 62471 photobiological test and falls in the exempt group (RG 0), where no optical hazard is considered reasonably foreseeable, even for continuous, unrestricted use. This refers to long-term, continuous exposure to Vital Vio s VioSafe visible light disinfection technology. Vital Vio s disinfecting wavelengths are approximately 405 nanometers, this wavelength targets a specific type of porphyrin molecule that is unique to bacteria, mold, and fungi cells and is not present in humans, plants or animals. The VioSafe technology is safe in part because it is in the visible light spectrum and not in the ultravoilet (UV) range. Additionally, the disinfecting wavelengths fall outside the blue light zone that is generally considered harmful.

What are the Effects of Disinfecting? Terminal Cleaning According to the American Journal of Infection Control, extensive covert studies have uniformly confirmed that opportunities for improving environmental cleaning can be identified in many health care settings as exhibited below. These studies took place in a wide range of health care settings in which a systematic evaluation of environmental cleaning was performed using the same fluorescent marking system. Terminal cleaning is the thorough environmental cleaning performed after the area has been used. (1.) * Heathcare Environmental Hygiene Study Group. 1. A. Varona-Barquin et al. (2013, May). Methods for assessing the adequacy of practice and improving room disinfection. Retrieved from http://www.ajicjournal.org/article/s0196-6553(13)00056-4/fulltext. Continuous Cleaning Vital Vio, a leader in clinical research, has proven the efficacy of the VioSafe technology in an active trauma room in a hospital s emergency department. This study showed post-install sample colony counts were statistically significantly lower than pre-install colony counts. As early as two weeks after installation, the samples collected from the trauma room showed reductions in overall bacteria colony counts. In just eight weeks after installation, statistically significant reductions were achieved. All post-install samplings showed lower average colony counts than in all pre-install samplings.

What Germs Does It Kill? Visible Light Disinfection Efficacy List Bacteria Gram Positive Staphylococcus aureus (incl. MRSA) Clostridium perfringens Clostridium difficile Enterococcus faecalis Staphylococcus epidermidis Staphyloccocus hyicus Streptococcus pyogenes Listeria monocytogenes Bacillus cereus Mycobacterium terrae Lactococcus lactis Lactobacillus plantarum Bacillus circulans Streptococcus thermophilus Gram Negative Acinetobacter baumannii Pseudomonas aeruginosa Klebsiella pneumoniae Proteus vulgaris Escherichia coli Salmonella enteritidis Shigella sonnei Serratia marcescens Salmonella typhimurium Bacteria Endospores Bacillus cereus Clostridium difficile Yeast and Filamentous Fungi Aspergillus niger Candida albicans Saccharomyces cerevisiae Results of Exposure Over Time Vital Vio conducted a qualitative study to show the effects of Code 3 s Patient Compartment Lights, powered by Vital Vio versus traditional LED patient compartment lights. Methicillin-resistant staphylococcus aureus (MRSA) were grown, swabbed onto glass slides and allowed to dry. Half the slides were placed under Code 3 s traditional patient compartment lights while half were placed under Code 3 s Patient Compartment Light powered by Vital Vio and left exposed for 72 hours. As seen through a visual comparison, the overall bacterial growth was much less on slides exposed to the continuous disinfecting technology used in Code 3 s Patient Compartment Lights powered by Vital Vio technology. A visual comparison between the overall amount of bacterial growth on each plate. Traditional LED Light Exposure Code 3 s Patient Compartment Light powered by Vital Vio Exposure *Other studies in controlled environments have shown up to a 99% reduction in germs after 24 hours. Results will vary in active trauma areas as new germs are constantly introduced and transferred throughout vehicles. Up to 99% Reduction in Germs, After 24 Hours!*

Product Information The Code 3 Patient Compartment Light powered by Vital Vio can be easily installed or retrofitted into existing industry standard cutouts. Design Features VioSafe technology Clear polycarbonate lens Fits in an industry standard 7.0 cutout 48 LEDs Bright and dim mode available Specifications 9.0 diameter (229 mm) x 0.5 depth (13 mm) Effective lumens: 750 bright mode and 250 dim mode 12-24VDC KKK-A-1822F certified and AMD compliant Internationally certified by IEC and UL 5-year warranty Product Installation PCL-LED-VV; 9.0 Patient Compartment Light, with Vital Vio Technology, bare leads PCL-LED-VV-P; 9.0 Patient Compartment Light, with Vital Vio Technology, with Deutsch connector WPPLUG1; standard 3-pin Deutsch connector These lights are designed for overhead installation in active environments and although the disinfection capability is both distance and dosage dependent, Vital Vio s technology is disinfecting every area of a space at all times, just at different rates based on distance. It is recommended that all existing patient compartment lighting in an ambulance be replaced with Code 3 s Patient Compartment Light powered by Vital Vio for optimum disinfection efficacy. Typical floor-to-ceiling heights for the products are most appropriate for spaces with a ceiling height under 12 feet.

Lights On, Germs Out! Code 3, Inc. engineers, manufactures and markets a complete line of lighting and soundbased warning products used by professionals in the police and fire markets. Since its inception in 1974, Code 3 s primary goal is to design products that enhance customer safety, including law enforcement officers, firemen and emergency medical technitions (EMT) personnel. Based in St. Louis, Missouri, Code 3 employs approximately 200 employees dedicated to finding solutions for the varying needs of its customers. We distribute products to over 70 countries through a network of manufacturer s representatives and distributors serving the public safety market. Our ISO 9001 certified facility uses Lean Six Sigma manufacturing processes and houses a world-class testing facility. Our employees are dedicated to providing innovative warning products and exceptional customer satisfaction. We are grateful for the opportunity to earn your business, and look forward to hearing your feedback and suggestions. Visit our website, Facebook, or YouTube for up-to-date product news and application videos. LIKE US facebook.com/code3inc CONNECT WITH US linkedin.com/company/code-3-inc- WATCH US youtube.com/code3inc For a complete listing of all products visit the Code 3 website at www.code3esg.com. Code 3, Inc. 10986 North Warson Road, St. Louis, MO 63114 (314) 426-2700 cs-c3@code3esg.com www.code3esg.com An ECCO Safety Group Company www.eccosafetygroup.com C3VV17 (1217-1K) 2017, Code 3, Inc. all rights reserved.