INDEX. Diagram Number(s) UDSA UDSAV UDSB-D UPA LSCA UC series ST-2 series c/w Autospark ignition. UC series c/w Thermoelectric (P/Pilot)

Similar documents
WA & RA EVAPORATIVEE COOLERS INSTRUCTION MANUAL

INSTALLATION INSTRUCTION MANUAL

AMBIRAD.... Vision Radiant Tube Heating Systems...

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

NOR-RAY-VAC CONTINUOUS RADIANT TUBE SYSTEM INSTALLATION INSTRUCTION MANUAL

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

HERRINGBONE HB COMBINED FLUE SYSTEM

Effective from 1st August Price List

EMERGENCY & SPECIALTY VEHICLES PANELS & PRODUCTS CATALOG

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

NOR-RAY-VAC CONTINUOUS RADIANT TUBE SYSTEM INSTALLATION AND OPERATING MANUAL

IEI NETWORK INTERFACE MODEL TS2040

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Ventilation in balance

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Installation Supplement

STEAMPAK Series BurnerPAK BMS Burner Management Systems

AMBIRAD. HEATI NG AND VENTILATION S OLUTIONS... Product Overview... AMBIRAD AIRBLOC NORDAIRNICHE BENSON

ADAPT Parasol EX a. Installation - Commissioning - Maintenance ADAPT Parasol EX a - m A1, B1

External insulated volume. control damper

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

The CAB & DAB Air Curtains

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SGU 930 SGU 930i. Control box

Products no longer available

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

BENSON.... Variante3 Fired Unit Heaters...

DOOR MONITORING/DURESS SYSTEM

DC 60 & DM 60 displays

Power Flame Incorporated

VCM-X Modular E-BUS Controller Technical Guide

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Heat Link. Technical Guide

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

SURFACE WARM CEILING HEATERS

... UDSA - UDSBD Gas fired unit heaters...

1.0 Digital Controller

21-light Remote Annunciator. Owner s Manual

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Multi-Path RTU-TYPE 2

RM7838A 7800 SERIES Relay Modules

EMERGENCY ASSISTANCE ALARMS

VCM-X Controller Technical Guide

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

TECHNICAL INSTRUCTIONS

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VSX RANGE OF RADIANT TUBE HEATERS

Eclipse Self-Check UV Scanner

TABLE B Remote Wire Connection

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

CommStat 4 Controller

VCM-X / RNE Operator Interfaces Technical Guide

RBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

DAP III Zone Master User s Guide

TAC Erie VL500. Application. Features. Zone Valve Control Center General Instructions

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

RS /E-EV C01 SERIES

Brivis Touch Controller. Installer Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Typical Operating & Maintenance Manual for SOLA-BOOST X-Air Project Name

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

Sensor Interface Module Installation/Operation Instructions

Natural Ventilation Controller with 24vDC drive NVC-1204

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

Wired Controller XK60

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

Schneider Electric Erie T155 Series

SEQUENCE OF OPERATIONS

SAX. Window & Wall Fans

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

AMBIRAD AMBIRAD AIRBLOC NORDAIRNICHE BENSON. HEATI NG AND VENTILATION S OLUTIONS... Price List

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

MBCE-110/230FR Flame Sensor Module

ADAPT Parasol EXb. Installation. Installation Commissioning Maintenance A1, B1

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

TABLE B Remote Wire Connection

Transcription:

Installation Wiring SmartCom 3 SMARTCOM 3 CONTRO PANE & WARM AIR WIRING INTERCONNECTS. Warnings All external wiring MUST comply with the current IEE wiring regulations. These instruction MUST be used in conjunction with the SmartCom user manual and the appropriate heater manual. Visit our Support Database at www.s-i-d.co.uk

INDEX Diagram Number(s) Heater type Single Stage (On/OFF) Two Stage (Hi/ow) Modulation UDSA UDSAV UDSB-D 1 2 3 UPA 1 2 3 SCA UC series ST-2 series c/w Autospark ignition 1 2 3 UC series c/w Thermoelectric (P/Pilot) 4 5 6 UESA 7 8 - OHUA 9 10 -

1 Single Stage (on/off) Heaters with Autospark Ignition to remote SmartCom³ SZ. SmartCom Singlezone 'Plug in' MUST be in Neutral position 41 40 9 5 6 1/ 2/N 10 B1 B0 B2 S/R0S/R1 should be connected by 6A mains Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). ON (ie BMS time control). (OCKOUT RESET) (ENABE/F.R.I./option C.R.F.) () (OCKOUT INDICATION) screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers 25 13 12 11 10 9 8 7 6 5 4 2 1 1 N N 2 3 Heater Installer connection terminal strip Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram). B A 25 13 12 11 10 9 8 7 6 5 4 2 1 J6 J' Add this if Fast Response Ignition (FRI) is required. Option Fast Response Ignition additional links required

2 Two Stage (hi/low) Heaters with Autospark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone 'Plug in' MUST be in Neutral position 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (option HEAT 2 INPUT) (option HEAT 2 OUTPUT) (OCKOUT RESET) (option DAMPER) (ENABE/F.R.I./option C.R.F.) () (OCKOUT INDICATION) C2 C0 C1 66 64 20 To other Slave Units OPTION 2 Stage (Hi/ow) option 25 13 12 11 10 9 8 7 6 5 4 2 1 Duct Sensor 1 N N 2 3 NETWORK OPTION: Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. J3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram). screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers B A 25 13 12 11 10 9 8 7 6 5 4 2 1 J6 J' Add this if Fast Response Ignition (FRI) is required. Option Fast Response Ignition additional links required

3 Modulation Heaters with AutoSpark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone 'Plug in' MUST be in Neutral position 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (OCKOUT RESET) (option DAMPER) (ENABE/F.R.I./option C.R.F.) () (OCKOUT INDICATION) (0-10Vdc output) C2 C0 C1 66 64 20 GM44 Interface board 64 66 To other Slave Units OPTION Duct Sensor MODUATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. 25 13 12 11 10 9 8 7 6 5 4 2 1 J' Add this if Fast Response Ignition (FRI) is required. B A 25 13 12 11 10 9 8 7 6 5 4 2 1 J6 1 N N 2 3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram). Option Fast Response Ignition additional links required should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers

4 Single Stage (on/off) Heaters with Thermoelectric (permanent pilot) to remote SmartCom³ SZ. SmartCom Singlezone 'Plug in' MUST be in Neutral position 41 40 9 5 6 1/ 2/N 10 B1 B0 B2 S/R0S/R1 should be connected by 6A mains cable*. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). (option C.R.F.) () screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set S1 within Engineers functions to '1' for remote sensor. 25 12 1 2 11 10 9 8 7 6 5 4 2 1 N N 3 J3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram).

5 Two Stage (hi/low) Heaters with Thermoelectric (permanent pilot) to remotesmartcom³ MZ (or Network). SmartCom Mulitizone 'Plug in' MUST be in Neutral position 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (option HEAT 2 INPUT) (option HEAT 2 OUTPUT) (option DAMPER) (option C.R.F.) () C2 C0 C1 66 64 C2 To other Slave Units OPTION 2 Stage (Hi/ow) option Duct Sensor 1 2 25 12 11 10 9 8 7 6 5 4 2 1 N N J3 J4 3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram). NETWORK OPTION: Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers

6 Modulation Heaters with Thermoelectric (permanent pilot) to remote SmartCom³ MZ (or Network). SmartCom Mulitizone 'Plug in' MUST be in Neutral position 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (option DAMPER) (option C.R.F.) () (0-10Vdc output) C2 C0 C1 66 64 20 GM44 Interface board 64 66 To other Slave Units OPTION Duct Sensor MODUATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION. Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. 1 2 25 12 11 10 9 8 7 6 5 4 2 1 N N J3 J4 3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph - refer to heater wiring diagram). should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). ON (ie BMS time control). OFF (ie door interlock. remote For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers

7 Single Stage (on/off) UESA Heaters with Autospark Ignition to remote SmartCom³ SZ. SmartCom Singlezone 'Plug in' MUST be in position 41 40 9 5 6 1/ 2/N 10 B1 B0 B2 S/R0S/R1 should be connected by 6A mains Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). ON (ie BMS time control). (OCKOUT RESET) (ENABE/F.R.I./option C.R.F.) () (OCKOUT INDICATION) screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers C 9 8 7 6 5 4 2 1 N UESA Heater Installer connection terminal strip Non-interrupted mains supply must be present at the heater 230V 1Ph.

8 Two Stage (hi/low) UESA Heaters with Autospark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone 'Plug in' MUST be in position 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (HEAT 2 INPUT where applicable) (HEAT 2 OUTPUT where applicable) (OCKOUT RESET) (ENABE/F.R.I./option C.R.F.) () (OCKOUT INDICATION) C2 C0 C1 66 64 20 To other Slave Units OPTION NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. C 9 8 7 6 5 4 2 1 N Duct Sensor should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. J3 if fitted Non-interrupted mains supply must be present at the heater 230V 1Ph. UESA screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers

9 Single Stage (on/off) OHUA Heaters with Autospark to remote SmartCom³ SZ. SmartCom Singlezone 41 40 9 5 6 1/ 2/N 10 B1 B0 B2 S/R0S/R1 should be connected by 6A mains cable*. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). () (OCKOUT INDICATION) screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set S1 within Engineers functions to '1' for remote sensor. 12 11 10 9 8 7 6 5 4 E3 N2 1 Non-interrupted mains supply must be present at the heater 230V 1Ph

10 Two Stage (hi/low) OHUA Heaters with Autospark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone 41 40 7 8 9 25 14 5 6 1/ 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (HEAT 2 INPUT where applicable) (HEAT 2 OUTPUT where applicable) () (OCKOUT INDICATION) C2 C0 C1 66 64 20 To other Slave Units 12 11 10 9 8 7 6 5 4 E3 N2 1 Duct Sensor Non-interrupted mains supply must be present at the heater 230V 1Ph NETWORK if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. should be connected by 0.75mm² cable. Max length is 100m. ow voltage switching inputs to be normally open (closed circuit to enable). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers Document reference number GB/SCOM/121/0110 AmbiRad imited Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United Kingdom. Telephone 01384 489700 Facsimile 01384 489707 Email info@ambirad.co.uk Website www.ambirad.co.uk Technical Suport www.s-i-d.co.uk AmbiRad is a registered trademark of AmbiRad imited. Because of continuous product innovation, AmbiRad reserve the right to change product specification without due notice