ARV.

Similar documents
ARS. 1

1

H4T R410A. refrigerant


Conditioning your ambient, maximising your comfort.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

kw COOLING kw HEATING

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

TCHVZ TCEVZ

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

GLIDER EVO GLIDER EVO. rcgroupairconditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

kw. technicalcatalogue

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

Water chillers water/water type SIGMA Technical information manual

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

44,9 202,0 kw. technicalcatalogue

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

water-cooled CHILLERS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Modular Air-cooled Chillers

PRODUCT GUIDE

pyxis u pyxis ua NEW rcgroupairconditioning

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

water-cooled CHILLERS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

30HXC Nominal cooling capacity kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

Conditioning your ambient, maximising your comfort.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

HYDRONIC RESIDENTIAL

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

CRIMSON & CRIMSON MAX

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Galletti Water chillers and heat pumps catalogue

pyxis pyxisa NEW rcgroupairconditioning

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Aquaflair TRAC-TRAF-TRAH

Air cooled industrial chillers

EN aquatech.piovan.com

Blue Box Epsilon Echos +

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HIWARM COMPACT kw

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

SyScroll 40 to 75 Air NEW

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

WATER-COOLED CHILLERS and condenserless chillers

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

Reversible Chillers and Heat Pumps - LEW SERIES kw

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

Index Features and advantages... 3 General characteristics... 5 Nomenclature... 9 Technical Specifications Sound levels...

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

unico pf unico pf rcgroupairconditioning

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

frigo turbo FL Chillers

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

Transcription:

ARV www.coldinnovation.it 1

INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag. 6 Condensers...pag. 6 Evaporators...pag. 7 Thermostatic expansion valves...pag. 8 Electronic expansion valves...pag. 8 Electronic regulation...pag. 9 Hydronic circuit... pag. 10 Operating range... pag. 11 Versions and accessories... pag. 11 Technical sheets... pag. 12 Performances... pag. 16 Dimensional drawings...pag. 23 Space for unit installation...pag. 27

ARV Water cooled water chillers, semi-hermetic screw compressors, brazed plate or shell and tube exchangers, refrigerant gas R134a. Heat pump by hydronic circuit inversion, condenserless unit. One compressor for each circuit, with capacity steps 25/50/75/100%. EER 4.7; ESEER 6. Units designed for commercial or industrial applications, where required a good protection from freezing. Only for indoor installation. Cooling capacity from 251 up to 1102 kw Heating capacity from 282 up to 1233 kw R134a refrigerant www.coldinnovation.it 3

Available versions CHILLER: basic version to be associate, for example, with a separate dry-cooler or using ground water and/or with an hydronic hot user plant. HEAT PUMP: with inversion on hydronic circuit. - This version is identical to chiller unit, but the control is based on hot water temperature, when switched to heat pump mode. - This unit need to invert the user water flow from the evaporator (chiller mode) to the condenser (heat pump mode) so to have hot water for the user. - The inversion on hydronic circuit shall be done by external devices not supplied with the unit. CONDENSERLESS UNITS: these units are supplied without integrated condenser; they can be connected with an outdoor air-cooled condenser; optimal solution for very cold climate can easily solve the problem to protect against the freezing, the circuits with water inside. PARTIAL HEAT RECOVERY (desuperheater): an heat exchanger is inserted along the compressors discharge line before the condenser, it s able to desuperheat the hot gas and produces hot water up to 55 C. The amount of recovered energy is around the 20% of the cooling energy production. CLIENT: units with special equipment or devices on request. 4 www.coldinnovation.it

Features Structure of electro-galvanized and painted steel sheet Air condensed water chiller with screw compressors. Ecological refrigerant R134a This refrigerant R134a with zero ozone depletion potential (ODP=0) together with a very low value for the global warming effective potential is the best choice for circuits with semi-hermetic screw compressors. Making maximum their energy performance. R134a www.coldinnovation.it 5

One semi-hermetic screw compressor on each refrigerant gas circuit, with 4 capacity steps for maximum cooling water temperature precision at partial loads. The choice of screw compressor allows you to have low vibration and noise emissions. Reliability is high thanks to the reduced number of moving parts and to the high capacity of the compressor to adapt to many different conditions. Due to its construction, semi-hermetic screw compressors has reduced vibration compared with piston compressors. The 4 cooling capacity steps allows the compressor to follow very well the variation of the user load, with a very good control of chilled water temperature. The design of the compressors is optimized for the project working range, so it s possible to reach very high performaces for energy saving. It s possible to equip the compressor with the stepless capacity control, very useful for sistems that need very accurate cooling capacity control. To have the maximum EER performance, it s necessary declare the water temperature working range, to select the best compressor configuration. Screw compressor Condensers Depending on the number of circuits of the unit, they can be brazed plates or shell and tube heat exchangers. In both solutions the condensers are abundantly dimensioned, to allow very low condensing temperature, for maximize EER performance. Brazed plates condensers made in stainless steel specifically designed for R134a. In addition to a very high mechanical resistance, due to the use of stainless steel, they have high corrosion resistance and very low content of refrigerant gas. Shell and tube condensers specifically designed for R134a, the exchangers are manufactured for the maximum reliability. The materials are: carbon steel: header, tube sheet, shell, refrigerant and water connections; copper: heat exchange tubes with inner finned surface; bonded steel bolts fit for the temperatures generated during use; Brazed plate condenser Shell and tube condenser 6 www.coldinnovation.it

Evaporators Depending on the number of circuits of the unit, they can be brazed plates or shell and tube heat exchangers. In both solutions the evaporators are abundantly dimensioned, to allow very low condensing temperature, for maximize EER performance. Brazed plates evaporators specifically designed for R134a, made in stainless steel. In addition to a very high mechanical resistance, due to the use of stainless steel, they have high corrosion resistance. These evaporators work in perfect countercurrent and allow to have very high evaporation temperature for maximize EER performance. An integrated distributor guarantees a perfect equalization of the refrigerant gas flow inside each plate heat exchanger, for maximum performances. Shell and tube evaporators specifically designed for R134a, the tube bundle is composed of a series of premodelled U-shaped tubes enabling the free expansion of them independently from the shell. The buffles are positioned so as to enable an optimal flow rate compatible with the pressure drop which may occur. The water connections are provided with flexible joints for the following advantage: easy and lowcost installation (assembly and disassembly); adaptability in case of shifts, dilatation and other movements; absorption of vibrations. These evaporators work in perfect countercurrent, and allow to have very high evaporation temperature for maximize EER performance. The materials are: carbon steel: header, tube sheet, shell, refrigerant and water connections; copper: heat exchange tubes with inner finned surface; bonded steel bolts fit for the temperatures generated during use; Brazed plate evaporator Shell and tube evaporator www.coldinnovation.it 7

Thermostatic expansion valves As standard all chillers are equipped with thermostatic expansion valves to ensure a return of dry gas to the compressor. Electronic expansion valves on request by request the unit can be equipped with electronic expansion valves. These valves, via an electronic driver, a temperature sensor and a pressure transmitter, are able to provide a more precise value of superheating. The graph below shows the effect of switching between the operation of a chiller with a TEV (thermostatic expansion valve) to an EEV (electronic expansion valve). The lowering of the average superheat value, the stability of the value itself and the operating pressure are clearly evident. Carel controllers and Electronic Expansion Valve 8 www.coldinnovation.it

Electronic regulation by a microprocessor card for the management and control of all functional parameters. The controls normally used are parametric products of Carel. For all chillers, the used control is Carel pco with a semi graphic terminal. The available languages are English, French, German, Italian and Spanish. The functions controlled are: a. regulation on inlet water temperature, with the alternative possibility of adjusting the output water temperature; b. management of cooling capacity with step capacity control of the compressors, depending on the request of the hydronic circuit; the control is such that the number of operating hours per year of each compressor is the same for everyone; c. prevent high pressure - this function allows you to reduce the cooling capacity of the compressor when the condensing pressure rises too much; d. condensing pressure control by a 0..10V signal, able to manage a modulating valve or a fan speed controller (in case of condenserless unit); e. antifreeze heaters (when installed) - a set of heaters protect the evaporator circuits containing water when their temperature drops below the safety threshold; f. circulation pump control; g. flow switch; h. water temperature set point variable by external contact; i. communication with supervisory systems; j. general circuit alarm; k. anti freeze alarm. pco control semigraphic terminal www.coldinnovation.it 9

Hydronic circuit The unit is normally equipped with Victaulic flexible couplings complete with clamps and solder terminal tubes. On request the unit can be completed with: flow switch, antifreeze heater for evaporator, water safety valve, water filter. Note: water filters and flow switch are supplied separately from the unit, to be installed by the user. Hydronic circuit Connection diagram of heat pump by hydronic circuit inversion 10 www.coldinnovation.it

Operating range Operating range for cooling mode Versions and accessories on demand N...Basic ME...Condenserless R...Partial recovery (desuperheater) CLIENT.Special features on specific customer needs EEV...Electronic expansion valve/s FL...Evaporator flowswitch FW...Water filter for evaporator and condenser BP...By-pass valve for condensing pressure setting WM...Water modulating valve for condensing pressure control RA...Antifreeze evaporator heater RS485... RS 485 serial interface (MODBUS protocol) RS232... RS 232 serial interface LON... LonWorks interface KON... Konnex interface BAC1... Bacnet MS/TP interface BAC2... Bacnet Ethernet/IP interface WEB... WEB server for remote control CK...Clock board RIF...Power factor corrector ST...Low starting current device AV...Anti-vibration mountings PR...Remote control panel SCC...Stepless capacity control SOV...2 way shut-off valve for safety valves www.coldinnovation.it 11

Technical Sheets ARV-N Size 251 291 331 371 441 501 422 482 Cooling capacity 248,5 285,7 321,4 370,7 431,2 488,2 409,9 461,4 Power input 52,8 58,6 64,8 73,9 87,4 97,9 87,3 98,1 Maximum power input at limit conditions 79,2 87,8 97,1 110,8 131,2 146,9 131,0 147,2 Water flow at evaporator (m3/h) 42,7 49,1 55,3 63,8 74,2 84,0 70,5 79,4 Pressure loss of hydronic circuit of evaporator (kpa) Thermal power at condenser at cooling mode 36 36 36 36 34 36 22 40 301,3 344,2 386,2 444,6 518,7 586,2 497,2 559,5 Water flow at condenser (m3/h) 51,8 59,2 66,4 76,5 89,2 100,8 85,5 96,2 Pressure loss of hydronic circuit of condenser (excluding water filter) (kpa) Heating capacity at condenser (heating mode) 50,0 50,0 50,0 51,0 52,0 52,0 45,0 45,0 EER (kw/kw) 4,7 4,9 5,0 5,0 4,9 5,0 4,7 4,7 ESEER (kw/kw) 6,2 6,4 6,5 6,6 6,5 6,5 6,1 6,2 281,9 321,4 360,2 414,4 483,9 546,5 465,3 523,5 Power input (heating mode) 66,7 73,9 81,7 93,2 110,3 123,6 110,2 123,8 Water flow at condenser (heating mode) (m3/h) Pressure loss of hydronic circuit of condenser (kpa) 48,5 55,3 61,9 71,3 83,2 94,0 80,0 90,0 50 50 50 51 52 52 45 45 COP (kw/kw) 4,2 4,3 4,4 4,4 4,4 4,4 4,2 4,2 Sound power(db(a)) 78,8 84,5 84,6 87,4 88,2 88,2 81,7 81,7 Number of compressors (n.) 1 1 1 1 1 1 2 2 Number of circuits (n.) 1 1 1 1 1 1 2 2 Rated current at nominal conditions (A) 87,7 97,3 107,6 122,7 145,2 162,7 145,0 163,0 Maximum current at full load (A) 139,9 155,1 171,6 195,8 231,6 259,5 231,3 260,0 Maximum starting current (A) 405,0 434,0 530,0 436,0 436,0 485,0 370,5 454,5 Maximum operating pressure PS (bar) 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 Number of antivibrating supports 4,0 4,0 4,0 4,0 4,0 4,0 4,0 4,0 Load capacity required to single antivibrating support (dan) Total weight with no water and excluded any hydronic kit (kg) 797,3 897,2 972,8 1063,7 1154,3 1218,2 1125,0 1190,7 1595 1794 1946 2127 2309 2436 2250 2381 12 www.coldinnovation.it

Basic version 532 592 622 672 712 752 822 872 922 982 1062 1122 496,9 571,4 607,1 642,8 692,1 741,4 801,9 862,5 919,5 976,4 1039,1 1101,7 105,6 117,1 123,4 129,5 138,7 147,8 161,2 174,9 185,4 195,9 208,4 220,9 158,4 175,7 185,0 194,3 208,0 221,7 241,8 262,3 278,1 293,8 312,6 331,3 85,5 98,3 104,4 110,6 119,0 127,5 137,9 148,3 158,1 167,9 178,7 189,5 48 43 46 51 36 41 47 57 55 34 38 42 602,6 688,5 730,5 772,3 830,8 889,2 963,1 1037,3 1104,9 1172,3 1247,4 1322,5 103,6 118,4 125,6 132,8 142,9 152,9 165,7 178,4 190,0 201,6 214,6 227,5 46,0 46,0 44,0 44,0 42,0 42,0 43,0 43,0 49,0 52,0 52,0 52,0 4,7 4,9 4,9 5,0 5,0 5,0 5,0 4,9 5,0 5,0 5,0 5,0 6,2 6,4 6,4 6,5 6,5 6,6 6,5 6,5 6,5 6,5 6,5 6,5 563,8 642,8 681,6 720,3 774,6 828,8 898,2 967,8 1030,5 1093,1 1163,1 1233,1 133,3 147,8 155,7 163,4 175,0 186,5 203,4 220,7 234,0 247,2 263,0 278,7 97,0 110,6 117,2 123,9 133,2 142,5 154,5 166,5 177,3 188,0 200,1 212,1 46 46 44 44 42 42 43 43 49 52 52 52 4,2 4,3 4,4 4,4 4,4 4,4 4,4 4,4 4,4 4,4 4,4 4,4 81,8 87,5 87,6 87,6 89,2 90,4 90,8 91,2 91,2 91,2 91,2 91,2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 175,5 194,5 204,9 215,1 230,4 245,5 267,8 290,5 308,0 325,4 346,1 366,8 279,8 310,3 326,8 343,1 367,4 391,5 427,1 463,3 491,3 518,9 552,0 585,1 492,7 531,3 536,5 637,6 645,2 558,7 569,9 581,2 590,0 647,7 658,1 769,4 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 4,0 4,0 4,0 4,0 8,0 8,0 8,0 8,0 8,0 8,0 4,0 1226,2 1328,6 1411,7 1494,7 804,7 861,9 932,3 1002,7 1069,0 1135,2 678,1 2452 2657 2823 2989 3219 3448 3729 4011 4276 4541 1356 Technical specifications at following conditions Cooling: evaporator water (in/out) 12/7 C; condenser water (in/out) 30/35 C; Condensing temperature 45 C for condenserless units Heating: evaporator water (in/out) 10/5 C; Condenser water (in/out) 40/45 C Power supply: 400-3 - 50Hz Sound power: according to ISO 3744 www.coldinnovation.it 13

Technical Sheets ARV-ME Size 251 291 331 371 441 501 482 532 Cooling capacity 221,1 254,3 286,1 329,9 383,8 434,5 410,6 442,3 Power input 60,3 66,8 73,9 84,3 99,8 111,7 112,0 120,5 Maximum power input at limit conditions 99,4 110,2 121,9 139,1 164,6 184,4 184,7 198,9 Water flow at evaporator (m3/h) 38,0 43,7 49,2 56,7 66,0 74,7 70,6 76,1 Pressure loss of hydronic circuit of evaporator (kpa) Thermal power at condenser at cooling mode 29 29 29 29 27 29 32 38 281,4 321,1 359,9 414,2 483,6 546,3 522,6 562,8 EER (kw/kw) 3,7 3,8 3,9 3,9 3,8 3,9 3,7 3,7 ESEER (kw/kw) 4,8 5,0 5,1 5,1 5,0 5,1 4,8 4,8 Sound power(db(a)) 78,8 84,5 84,6 87,4 88,2 88,2 81,7 81,8 Number of compressors (n.) 1 1 1 1 1 1 2 2 Number of circuits (n.) 1 1 1 1 1 1 2 2 Rated current at nominal conditions (A) 102,5 113,6 125,6 143,3 169,6 190,0 190,3 204,9 Maximum current at full load (A) 175,6 194,7 215,3 245,7 290,7 325,7 326,3 351,2 Maximum starting current (A) 538,7 577,2 704,9 579,9 579,9 645,1 591,3 641,1 Maximum operating pressure PS (bar) 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 Number of antivibrating supports 4,0 4,0 4,0 4,0 4,0 4,0 Load capacity required to single antivibrating support (dan) Total weight with no water and excluded any hydronic kit (kg) 836,3 921,6 1010,8 1079,0 1151,1 1172,1 1673 1843 2022 2158 2302 2344 14 www.coldinnovation.it

Condenserless version 592 622 672 712 752 822 872 922 982 1062 1122 508,5 540,3 572,1 616,0 659,8 713,7 767,6 818,3 869,0 925 980 133,6 140,8 147,8 158,2 168,6 183,9 199,5 211,6 227,5 237,7 256,6 220,5 232,2 243,8 261,1 278,2 303,5 329,2 349,1 375,4 392,2 423,5 87,5 92,9 98,4 105,9 113,5 122,8 132,0 140,8 149,5 159 168,6 34 36 40 29 32 37 45 44 27 30 33 642,2 681,1 719,9 774,2 828,4 897,7 967,1 1029,9 1096,5 1163 1237 3,8 3,8 3,9 3,9 3,9 3,9 3,8 3,9 3,8 3,8 3,8 5,0 5,0 5,1 5,1 5,1 5,1 5,0 5,1 5,0 5,10 5,00 87,5 87,6 87,6 89,2 90,4 90,8 91,2 91,2 91,2 91,2 91,2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 227,2 239,3 251,2 269,0 286,7 312,7 339,2 359,7 386,8 404 436 389,4 410,2 430,6 461,2 491,4 536,1 581,5 616,6 663,0 693 748 690,8 696,9 830,5 839,4 723,2 736,2 749,5 759,7 838,4 847,1 997,5 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6 6 4,0 8,0 8,0 8,0 8,0 8,0 8,0 1238,9 666,9 714,4 772,8 831,1 886,0 941,0 2478 2668 2858 3091 3324 3544 3764 Technical specifications at following conditions Cooling: evaporator water (in/out) 12/7 C; condenser water (in/out) 30/35 C; Condensing temperature 45 C for condenserless units Heating: evaporator water (in/out) 10/5 C; Condenser water (in/out) 40/45 C Power supply: 400-3 - 50Hz Sound power: according to ISO 3744 www.coldinnovation.it 15

Performances Cooling mode ARV-N Evaporator outlet water temperature ( C) 5 6 7 8 10 15 Condenser outlet water temperature ( C) Condenser outlet water temperature ( C) 35 40 251 233,6 52,8 241,0 52,8 248,5 52,8 255,9 52,8 270,8 52,8 308,1 52,8 291 268,6 58,6 277,1 58,6 285,7 58,6 294,3 58,6 311,4 58,6 354,3 58,6 331 302,1 64,8 311,8 64,8 321,4 64,8 331,1 64,8 350,3 64,8 398,6 64,8 371 348,4 73,9 359,6 73,9 370,7 73,9 381,8 73,9 404,1 73,9 459,7 73,9 441 405,4 87,4 418,3 87,4 431,2 87,4 444,2 87,4 470,0 87,4 534,7 87,4 501 458,9 97,9 473,6 97,9 488,2 97,9 502,9 97,9 532,2 97,9 605,4 97,9 482 433,7 98,1 447,6 98,1 461,4 98,1 475,2 98,1 502,9 98,1 572,1 98,1 532 467,1 105,6 482,0 105,6 496,9 105,6 511,8 105,6 541,7 105,6 616,2 105,6 592 537,1 117,1 554,2 117,1 571,4 117,1 588,5 117,1 622,8 117,1 708,5 117,1 622 570,7 123,4 588,9 123,4 607,1 123,4 625,3 123,4 661,7 123,4 752,8 123,4 672 604,3 129,5 623,5 129,5 642,8 129,5 662,1 129,5 700,7 129,5 797,1 129,5 712 650,6 138,7 671,3 138,7 692,1 138,7 712,9 138,7 754,4 138,7 858,2 138,7 752 696,9 147,8 719,1 147,8 741,4 147,8 763,6 147,8 808,1 147,8 919,3 147,8 822 753,8 161,2 777,9 161,2 801,9 161,2 826,0 161,2 874,1 161,2 994,4 161,2 872 810,7 174,9 836,6 174,9 862,5 174,9 888,3 174,9 940,1 174,9 1069,5 174,9 922 864,3 185,4 891,9 185,4 919,5 185,4 947,0 185,4 1002,2 185,4 1140,1 185,4 982 917,9 195,9 947,2 195,9 976,4 195,9 1005,7 195,9 1064,3 195,9 1210,8 195,9 251 221,9 59,7 229,0 59,7 236,0 59,7 243,1 59,7 257,3 59,7 292,7 59,7 291 255,1 66,2 263,3 66,2 271,4 66,2 279,6 66,2 295,8 66,2 336,5 66,2 331 287,0 73,2 296,2 73,2 305,3 73,2 314,5 73,2 332,8 73,2 378,6 73,2 371 331,0 83,6 341,6 83,6 352,2 83,6 362,7 83,6 383,8 83,6 436,7 83,6 441 385,1 98,9 397,4 98,9 409,7 98,9 422,0 98,9 446,5 98,9 508,0 98,9 501 436,0 110,8 449,9 110,8 463,8 110,8 477,7 110,8 505,6 110,8 575,1 110,8 482 412,0 111,0 425,2 111,0 438,3 111,0 451,5 111,0 477,8 111,0 543,5 111,0 532 443,8 119,5 457,9 119,5 472,1 119,5 486,2 119,5 514,6 119,5 585,4 119,5 592 510,3 132,4 526,5 132,4 542,8 132,4 559,1 132,4 591,7 132,4 673,1 132,4 622 542,1 139,5 559,5 139,5 576,8 139,5 594,1 139,5 628,7 139,5 715,2 139,5 672 574,0 146,5 592,4 146,5 610,7 146,5 629,0 146,5 665,6 146,5 757,2 146,5 712 618,0 156,9 637,8 156,9 657,5 156,9 677,2 156,9 716,7 156,9 815,3 156,9 752 662,1 167,1 683,2 167,1 704,3 167,1 725,4 167,1 767,7 167,1 873,3 167,1 822 716,1 182,3 739,0 182,3 761,8 182,3 784,7 182,3 830,4 182,3 944,7 182,3 872 770,2 197,8 794,8 197,8 819,4 197,8 843,9 197,8 893,1 197,8 1016,0 197,8 922 821,1 209,7 847,3 209,7 873,5 209,7 899,7 209,7 952,1 209,7 1083,1 209,7 982 872,0 221,5 899,8 221,5 927,6 221,5 955,5 221,5 1011,1 221,5 1150,3 221,5 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value 16 www.coldinnovation.it

Cooling mode ARV-N Evaporator outlet water temperature ( C) 5 6 7 8 10 15 Condenser outlet water temperature ( C) Condenser outlet water temperature ( C) 45 50 251 210,2 66,7 216,9 66,7 223,6 66,7 230,3 66,7 243,7 66,7 277,3 66,7 291 241,7 73,9 249,4 73,9 257,1 73,9 264,8 73,9 280,3 73,9 318,8 73,9 331 271,9 81,7 280,6 81,7 289,3 81,7 297,9 81,7 315,3 81,7 358,7 81,7 371 313,6 93,2 323,6 93,2 333,6 93,2 343,6 93,2 363,6 93,2 413,7 93,2 441 364,8 110,3 376,5 110,3 388,1 110,3 399,8 110,3 423,0 110,3 481,3 110,3 501 413,0 123,6 426,2 123,6 439,4 123,6 452,6 123,6 478,9 123,6 544,9 123,6 482 390,3 123,8 402,8 123,8 415,3 123,8 427,7 123,8 452,6 123,8 514,9 123,8 532 420,4 133,3 433,8 133,3 447,2 133,3 460,7 133,3 487,5 133,3 554,6 133,3 592 483,4 147,8 498,8 147,8 514,3 147,8 529,7 147,8 560,5 147,8 637,7 147,8 622 513,6 155,7 530,0 155,7 546,4 155,7 562,8 155,7 595,6 155,7 677,5 155,7 672 543,8 163,4 561,2 163,4 578,5 163,4 595,9 163,4 630,6 163,4 717,4 163,4 712 585,5 175,0 604,2 175,0 622,9 175,0 641,6 175,0 679,0 175,0 772,4 175,0 752 627,2 186,5 647,2 186,5 667,2 186,5 687,3 186,5 727,3 186,5 827,4 186,5 822 678,4 203,4 700,1 203,4 721,7 203,4 743,4 203,4 786,7 203,4 895,0 203,4 872 729,7 220,7 752,9 220,7 776,2 220,7 799,5 220,7 846,1 220,7 962,5 220,7 922 777,9 234,0 802,7 234,0 827,5 234,0 852,3 234,0 902,0 234,0 1026,1 234,0 982 826,1 247,2 852,4 247,2 878,8 247,2 905,2 247,2 957,9 247,2 1089,7 247,2 251 198,5 73,6 204,9 73,6 211,2 73,6 217,5 73,6 230,2 73,6 261,9 73,6 291 228,3 81,6 235,6 81,6 242,8 81,6 250,1 81,6 264,7 81,6 301,1 81,6 331 256,8 90,2 265,0 90,2 273,2 90,2 281,4 90,2 297,8 90,2 338,8 90,2 371 296,2 102,9 305,6 102,9 315,1 102,9 324,5 102,9 343,4 102,9 390,7 102,9 441 344,6 121,8 355,6 121,8 366,6 121,8 377,5 121,8 399,5 121,8 454,5 121,8 501 390,1 136,4 402,5 136,4 415,0 136,4 427,4 136,4 452,3 136,4 514,6 136,4 482 368,7 136,7 380,4 136,7 392,2 136,7 404,0 136,7 427,5 136,7 486,3 136,7 532 397,0 147,1 409,7 147,1 422,4 147,1 435,1 147,1 460,4 147,1 523,8 147,1 592 456,5 163,1 471,1 163,1 485,7 163,1 500,3 163,1 529,4 163,1 602,2 163,1 622 485,1 171,8 500,6 171,8 516,0 171,8 531,5 171,8 562,5 171,8 639,9 171,8 672 513,6 180,4 530,0 180,4 546,4 180,4 562,8 180,4 595,6 180,4 677,5 180,4 712 553,0 193,2 570,6 193,2 588,3 193,2 605,9 193,2 641,2 193,2 729,5 193,2 752 592,4 205,9 611,3 205,9 630,2 205,9 649,1 205,9 686,9 205,9 781,4 205,9 822 640,7 224,6 661,2 224,6 681,6 224,6 702,1 224,6 743,0 224,6 845,2 224,6 872 689,1 243,6 711,1 243,6 733,1 243,6 755,1 243,6 799,1 243,6 909,0 243,6 922 734,6 258,3 758,1 258,3 781,5 258,3 805,0 258,3 851,9 258,3 969,1 258,3 982 780,2 272,9 805,1 272,9 830,0 272,9 854,9 272,9 904,7 272,9 1029,2 272,9 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value www.coldinnovation.it 17

Heating mode ARV-N Condenser outlet water temperature ( C) 30 35 40 45 50 55 Evaporator outlet water temperature ( C) Evaporator outlet water temperature ( C) 5 7 251 281,3 45,9 277,1 52,8 272,8 59,7 268,5 66,7 264,2 73,6 259,9 80,5 291 321,6 50,9 316,4 58,6 311,2 66,2 306,0 73,9 300,7 81,6 295,5 89,2 331 360,8 56,3 354,8 64,8 348,8 73,2 342,8 81,7 336,8 90,2 330,7 98,7 371 415,5 64,2 408,4 73,9 401,4 83,6 394,3 93,2 387,3 102,9 380,2 112,6 441 484,6 76,0 476,6 87,4 468,6 98,9 460,6 110,3 452,6 121,8 444,6 133,3 501 547,8 85,1 538,6 97,9 529,4 110,8 520,2 123,6 511,0 136,4 501,8 149,3 482 522,5 85,3 514,5 98,1 506,6 111,0 498,6 123,8 490,6 136,7 482,7 149,5 532 562,7 91,8 554,1 105,6 545,5 119,5 536,9 133,3 528,3 147,1 519,8 161,0 592 643,2 101,8 632,8 117,1 622,3 132,4 611,9 147,8 601,5 163,1 591,0 178,5 622 682,5 107,2 671,3 123,4 660,0 139,5 648,8 155,7 637,6 171,8 626,3 188,0 672 721,7 112,5 709,7 129,5 697,6 146,5 685,6 163,4 673,5 180,4 661,5 197,4 712 776,4 120,5 763,3 138,7 750,2 156,9 737,2 175,0 724,1 193,2 711,1 211,4 752 831,0 128,4 816,9 147,8 802,8 167,1 788,7 186,5 774,6 205,9 760,5 225,2 822 900,0 140,1 884,9 161,2 869,9 182,3 854,8 203,4 839,7 224,6 824,7 245,7 872 969,3 152,0 953,3 174,9 937,2 197,8 921,2 220,7 905,2 243,6 889,2 266,5 922 1032,4 161,1 1015,2 185,4 998,0 209,7 980,8 234,0 963,6 258,3 946,4 282,6 982 1095,5 170,2 1077,1 195,9 1058,7 221,5 1040,3 247,2 1021,9 272,9 1003,5 298,5 251 297,0 45,9 292,0 52,8 286,9 59,7 281,9 66,7 276,8 73,6 271,8 80,5 291 339,6 50,9 333,5 58,6 327,5 66,2 321,4 73,9 315,3 81,6 309,2 89,2 331 381,1 56,3 374,1 64,8 367,1 73,2 360,1 81,7 353,2 90,2 346,2 98,7 371 438,8 64,2 430,7 73,9 422,5 83,6 414,4 93,2 406,2 102,9 398,0 112,6 441 511,8 76,0 502,5 87,4 493,2 98,9 483,9 110,3 474,6 121,8 465,3 133,3 501 578,5 85,1 567,9 97,9 557,2 110,8 546,5 123,6 535,9 136,4 525,2 149,3 482 551,6 85,3 542,2 98,1 532,9 111,0 523,5 123,8 514,2 136,7 504,8 149,5 532 594,0 91,8 583,9 105,6 573,8 119,5 563,8 133,3 553,7 147,1 543,6 161,0 592 679,2 101,8 667,1 117,1 654,9 132,4 642,8 147,8 630,6 163,1 618,4 178,5 622 720,8 107,2 707,7 123,4 694,6 139,5 681,6 155,7 668,5 171,8 655,5 188,0 672 762,2 112,5 748,2 129,5 734,3 146,5 720,3 163,4 706,3 180,4 692,3 197,4 712 820,0 120,5 804,8 138,7 789,7 156,9 774,6 175,0 759,4 193,2 744,3 211,4 752 877,7 128,4 861,4 147,8 845,0 167,1 828,7 186,5 812,4 205,9 796,1 225,2 822 950,5 140,1 933,1 161,2 915,6 182,3 898,1 203,4 880,6 224,6 863,2 245,7 872 1023,6 152,0 1005,0 174,9 986,4 197,8 967,8 220,7 949,2 243,6 930,6 266,5 922 1090,4 161,1 1070,4 185,4 1050,5 209,7 1030,5 234,0 1010,5 258,3 990,6 282,6 982 1157,0 170,2 1135,7 195,9 1114,4 221,5 1093,0 247,2 1071,7 272,9 1050,4 298,5 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value 18 www.coldinnovation.it

Heating mode ARV-N Condenser outlet water temperature ( C) 30 35 40 45 50 55 Evaporator outlet water temperature ( C) Evaporator outlet water temperature ( C) 10 15 251 341,7 47,9 324,4 53,5 307,0 59,2 289,7 64,9 272,3 70,6 255,0 76,2 291 390,9 53,1 370,8 59,3 350,6 65,6 330,4 71,9 310,2 78,2 290,0 84,5 331 438,8 58,7 416,0 65,6 393,1 72,6 370,3 79,5 347,5 86,5 324,7 93,5 371 505,3 67,0 478,9 74,9 452,5 82,8 426,1 90,8 399,7 98,7 373,3 106,6 441 589,2 79,2 558,7 88,6 528,1 98,0 497,5 107,4 467,0 116,8 436,4 126,2 501 666,1 88,7 631,4 99,3 596,7 109,8 562,0 120,3 527,3 130,8 492,6 141,4 482 634,6 88,9 602,4 99,5 570,2 110,0 538,0 120,5 505,8 131,1 473,5 141,6 532 683,4 95,7 648,7 107,1 614,0 118,4 579,3 129,8 544,6 141,1 509,9 152,5 592 781,9 106,1 741,5 118,7 701,2 131,3 660,8 143,9 620,4 156,4 580,1 169,0 622 829,8 111,8 786,8 125,0 743,8 138,3 700,8 151,5 657,8 164,8 614,8 178,0 672 877,6 117,3 831,9 131,3 786,3 145,2 740,7 159,1 695,0 173,0 649,4 186,9 712 944,2 125,7 895,0 140,6 845,7 155,5 796,5 170,4 747,3 185,3 698,1 200,2 752 1010,7 133,9 957,9 149,8 905,1 165,7 852,3 181,5 799,4 197,4 746,6 213,3 822 1094,5 146,1 1037,5 163,4 980,5 180,7 923,5 198,0 866,6 215,4 809,6 232,7 872 1178,5 158,5 1117,3 177,2 1056,2 196,0 995,1 214,8 934,0 233,6 872,9 252,4 922 1255,4 168,0 1190,2 187,9 1124,9 207,9 1059,6 227,8 994,4 247,7 929,1 267,6 982 1332,3 177,5 1262,9 198,5 1193,4 219,6 1124,0 240,6 1054,6 261,7 985,2 282,7 251 383,2 48,9 362,8 54,7 342,4 60,5 322,0 66,3 301,7 72,1 281,3 77,9 291 438,6 54,2 414,9 60,7 391,3 67,1 367,6 73,5 343,9 80,0 320,2 86,4 331 492,4 60,0 465,6 67,1 438,9 74,2 412,1 81,3 385,4 88,4 358,6 95,5 371 567,2 68,4 536,2 76,6 505,3 84,7 474,3 92,8 443,4 100,9 412,4 109,0 441 661,2 81,0 625,3 90,6 589,5 100,2 553,6 109,8 517,8 119,4 481,9 129,0 501 747,6 90,7 706,9 101,5 666,2 112,2 625,5 123,0 584,8 133,7 544,1 144,5 482 711,7 90,9 673,8 101,7 635,9 112,4 598,1 123,2 560,2 134,0 522,4 144,8 532 766,4 97,8 725,6 109,4 684,9 121,0 644,1 132,7 603,3 144,3 562,5 155,9 592 877,2 108,5 829,9 121,3 782,5 134,2 735,1 147,1 687,8 159,9 640,4 172,8 622 931,1 114,3 880,6 127,8 830,2 141,4 779,8 154,9 729,3 168,5 678,9 182,0 672 984,8 120,0 931,3 134,2 877,8 148,4 824,2 162,6 770,7 176,9 717,2 191,1 712 1059,6 128,5 1001,9 143,7 944,2 158,9 886,5 174,2 828,8 189,4 771,1 204,6 752 1134,3 136,9 1072,4 153,1 1010,5 169,4 948,6 185,6 886,7 201,8 824,8 218,0 822 1228,2 149,3 1161,4 167,0 1094,6 184,7 1027,8 202,4 961,0 220,2 894,2 237,9 872 1322,4 162,0 1250,7 181,2 1179,0 200,4 1107,3 219,6 1035,6 238,8 963,9 258,0 922 1408,8 171,8 1332,3 192,1 1255,7 212,5 1179,2 232,9 1102,6 253,2 1026,1 273,6 982 1495,2 181,4 1413,8 203,0 1332,3 224,5 1250,9 246,0 1169,5 267,5 1088,1 289,0 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value www.coldinnovation.it 19

Cooling mode ARV-ME Evaporator outlet water temperature ( C) 5 6 7 8 10 15 Condensing temperature ( C) Condensing temperature ( C) 40 45 251 225,5 53,4 232,7 53,6 239,9 53,9 247,1 54,1 261,5 54,6 297,5 55,8 291 259,3 59,2 267,6 59,5 275,9 59,7 284,2 60,0 300,7 60,5 342,1 61,9 331 291,7 65,5 301,1 65,8 310,4 66,1 319,7 66,4 338,3 66,9 384,9 68,4 371 336,5 74,7 347,2 75,0 358,0 75,4 368,7 75,7 390,2 76,4 443,9 78,1 441 391,4 88,4 403,9 88,8 416,4 89,2 428,9 89,6 453,9 90,4 516,4 92,4 501 443,2 99,0 457,3 99,5 471,5 99,9 485,6 100,4 513,9 101,3 584,6 103,5 482 418,8 99,2 432,2 99,6 445,5 100,1 458,9 100,5 485,6 101,5 552,5 103,7 532 451,1 106,8 465,5 107,3 479,9 107,7 494,3 108,2 523,0 109,2 595,0 111,6 592 518,7 118,4 535,2 118,9 551,8 119,5 568,3 120,0 601,4 121,1 684,2 123,8 622 551,1 124,7 568,7 125,3 586,3 125,8 603,8 126,4 639,0 127,5 727,0 130,4 672 583,5 130,9 602,1 131,5 620,7 132,1 639,4 132,7 676,6 133,9 769,7 136,9 712 628,2 140,2 648,3 140,8 668,3 141,5 688,4 142,1 728,5 143,4 828,7 146,6 752 673,0 149,4 694,4 150,1 715,9 150,7 737,4 151,4 780,3 152,8 887,7 156,2 822 727,9 163,0 751,1 163,7 774,4 164,4 797,6 165,2 844,1 166,7 960,2 170,4 872 782,9 176,8 807,9 177,6 832,8 178,4 857,8 179,2 907,8 180,8 1032,7 184,8 922 834,6 187,4 861,2 188,3 887,9 189,2 914,5 190,0 967,8 191,7 1101,0 196,0 982 886,3 201,5 914,6 202,5 942,9 203,4 971,2 204,3 1027,8 206,1 1169,2 210,7 251 207,9 59,7 214,5 60,0 221,1 60,3 227,8 60,5 241,0 61,1 274,2 62,4 291 239,0 66,2 246,6 66,5 254,3 66,8 261,9 67,1 277,2 67,7 315,3 69,2 331 268,9 73,2 277,5 73,6 286,1 73,9 294,6 74,2 311,8 74,9 354,7 76,6 371 310,1 83,5 320,0 83,9 329,9 84,3 339,8 84,7 359,6 85,5 409,1 87,4 441 360,8 98,9 372,3 99,3 383,8 99,8 395,3 100,2 418,3 101,1 475,9 103,4 501 408,4 110,7 421,5 111,2 434,5 111,7 447,6 112,3 473,6 113,3 538,8 115,8 482 386,0 110,9 398,3 111,5 410,6 112,0 423,0 112,5 447,6 113,5 509,2 116,0 532 415,7 119,4 429,0 120,0 442,3 120,5 455,5 121,1 482,1 122,2 548,4 124,9 592 478,0 132,4 493,3 133,0 508,5 133,6 523,8 134,2 554,3 135,4 630,6 138,5 622 507,9 139,5 524,1 140,1 540,3 140,8 556,5 141,4 589,0 142,7 670,0 145,8 672 537,8 146,4 555,0 147,1 572,1 147,8 589,3 148,4 623,6 149,8 709,4 153,1 712 579,0 156,8 597,5 157,5 616,0 158,2 634,5 159,0 671,4 160,4 763,8 164,0 752 620,2 167,1 640,0 167,9 659,8 168,6 679,6 169,4 719,2 170,9 818,2 174,7 822 670,9 182,3 692,3 183,1 713,7 183,9 735,1 184,8 777,9 186,4 885,0 190,6 872 721,5 197,7 744,6 198,6 767,6 199,5 790,6 200,4 836,7 202,2 951,8 206,7 922 769,2 209,7 793,8 210,6 818,3 211,6 842,9 212,5 892,0 214,4 1014,7 219,2 982 816,9 225,4 843,0 226,5 869,0 227,5 895,1 228,5 947,3 230,6 1077,6 235,7 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value 20 www.coldinnovation.it

Cooling mode ARV-ME Evaporator outlet water temperature ( C) 5 6 7 8 10 15 Condensing temperature ( C) Condensing temperature ( C) 50 55 251 190,2 66,0 196,3 66,3 202,3 66,6 208,4 67,0 220,5 67,6 250,9 69,1 291 218,7 73,2 225,7 73,6 232,7 73,9 239,6 74,2 253,6 74,9 288,5 76,6 331 246,0 81,0 253,9 81,3 261,7 81,7 269,6 82,1 285,3 82,8 324,6 84,7 371 283,8 92,4 292,8 92,8 301,9 93,2 310,9 93,7 329,0 94,5 374,3 96,6 441 330,1 109,3 340,6 109,8 351,2 110,3 361,7 110,8 382,8 111,8 435,5 114,3 501 373,7 122,5 385,7 123,0 397,6 123,6 409,5 124,2 433,4 125,3 493,0 128,1 482 353,2 122,7 364,5 123,3 375,7 123,8 387,0 124,4 409,6 125,5 465,9 128,3 532 380,4 132,1 392,5 132,7 404,7 133,3 416,8 133,9 441,1 135,1 501,8 138,1 592 437,4 146,5 451,4 147,1 465,3 147,8 479,3 148,5 507,2 149,8 577,0 153,1 622 464,7 154,3 479,6 155,0 494,4 155,7 509,2 156,4 538,9 157,8 613,1 161,3 672 492,1 162,0 507,8 162,7 523,5 163,4 539,2 164,2 570,6 165,6 649,1 169,3 712 529,8 173,4 546,7 174,2 563,6 175,0 580,5 175,8 614,3 177,4 698,9 181,4 752 567,5 184,8 585,6 185,6 603,7 186,5 621,9 187,3 658,1 189,0 748,6 193,2 822 613,9 201,6 633,5 202,5 653,0 203,4 672,6 204,4 711,8 206,2 809,8 210,8 872 660,2 218,7 681,3 219,7 702,4 220,7 723,4 221,7 765,6 223,7 870,9 228,7 922 703,8 231,9 726,3 232,9 748,8 234,0 771,2 235,1 816,2 237,2 928,5 242,5 982 747,5 249,3 771,3 250,5 795,2 251,6 819,0 252,7 866,7 255,0 986,0 260,7 251 172,5 72,4 178,0 72,7 183,5 73,0 189,0 73,4 200,1 74,0 227,6 75,7 291 198,4 80,2 204,7 80,6 211,0 81,0 217,4 81,3 230,0 82,1 261,7 83,9 331 223,2 88,7 230,3 89,1 237,4 89,5 244,6 90,0 258,8 90,8 294,4 92,8 371 257,4 101,3 265,6 101,7 273,8 102,2 282,0 102,6 298,5 103,6 339,5 105,9 441 299,4 119,8 309,0 120,4 318,6 120,9 328,1 121,5 347,2 122,6 395,0 125,3 501 339,0 134,2 349,8 134,8 360,7 135,4 371,5 136,1 393,1 137,3 447,2 140,3 482 320,4 134,5 330,6 135,1 340,8 135,7 351,1 136,3 371,5 137,5 422,6 140,6 532 345,1 144,8 356,1 145,4 367,1 146,1 378,1 146,7 400,1 148,1 455,2 151,4 592 396,8 160,5 409,4 161,2 422,1 162,0 434,7 162,7 460,1 164,1 523,4 167,8 622 421,6 169,1 435,0 169,8 448,5 170,6 461,9 171,4 488,8 172,9 556,1 176,8 672 446,4 177,5 460,6 178,3 474,9 179,1 489,1 179,9 517,6 181,5 588,8 185,6 712 480,6 190,1 495,9 190,9 511,3 191,8 526,6 192,7 557,3 194,4 634,0 198,7 752 514,8 202,5 531,2 203,4 547,7 204,4 564,1 205,3 596,9 207,1 679,1 211,8 822 556,8 220,9 574,6 221,9 592,4 222,9 610,2 223,9 645,7 226,0 734,6 231,0 872 598,9 239,6 618,0 240,7 637,1 241,8 656,2 242,9 694,4 245,1 790,0 250,6 922 638,5 254,1 658,8 255,3 679,2 256,4 699,6 257,6 740,3 259,9 842,2 265,7 982 678,0 273,2 699,7 274,5 721,3 275,7 742,9 277,0 786,2 279,5 894,4 285,7 = Cooling capacity ; = Power input; Hc= Heating capacity Correction factors for ethylen glicol percentage and for difference temperature of water at inlet-outlet, see at end of chapter cooling main value; heating main value www.coldinnovation.it 21

Correction factors for ethylene glycol content Weight percentage of glycol % 0 10 20 30 40 50 Freezing point ( C) 0-3,6-8,8-15,7-24,9-37,1 Minimum outlet water temperature allowed ( C) 5,5 1,9-3,3-10,2-19,4-31,6 Cooling capacity correction factor for ethylene glycol (dt=5 C) 1,000 0,993 0,985 0,978 0,970 0,963 Correction factors for differential water temperature IN-OUT at evaporator Differential water temperature (Inlet - Outlet) C 3 4 5 6 7 8 9 10 Cooling capacity correction factor 0,970 0,985 1,000 1,008 1,016 1,024 1,032 1,040 Correction factors for differential water temperature IN-OUT at condenser Differential water temperature (Inlet - Outlet) C 3 4 5 6 7 8 9 10 Cooling capacity correction factor 1,017 1,009 1,000 0,992 0,983 0,975 0,966 0,958 Power input correction factor 0,964 0,982 1,000 1,018 1,036 1,054 1,072 1,090 The technical data in this document are not binding. Rigel Impianti S.r.l. keeps rights to make any technical modifications at any time without notice due to its improvement process. 22 www.coldinnovation.it

DIMENSIONAL DRAWINGS Unit ARV sizes 251, 291, 331, 371, 441, 501 www.coldinnovation.it 23

Unit ARV sizes 251, 291, 331, 371, 441, 501 ME version 24 www.coldinnovation.it

Unit ARV sizes 422, 482, 532, 592, 622, 672, 712, 752, 822, 872, 922, 982 www.coldinnovation.it 25

Unit ARV sizes 482, 532, 592, 622, 672, 712, 752, 822, 872, 922, 982 ME version 26 www.coldinnovation.it

SPACE FOR UNIT INSTALLATION www.coldinnovation.it 27

Notes......

Notes

Notes......

Cold Innovation Zona Industriale Padule - 06020, Gubbio (PG) - Italy Tel. +39 075 929 11 13 Fax +39 075 929 92 94 info@coldinnovation.it www.coldinnovation.it

VENERUCCI 0214 www.coldinnovation.it