Quick Selection Guide Analog Addressable Fire Systems

Similar documents
Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

Analog fire panels FPA-1000 Family

D7024 Fire Alarm Control Panel

FPA 1000 UL Analog Addressable Fire Panel

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Quick Selection Guide Fire Systems LSN Periphery

Fire Alarm Control Panels FPD-7024

NETWORK FIRE ALARM CONTROL PANEL. Features

Desigo Fire Safety intelligent detectors for complete safety

Modular Fire Panel 5000 Series Just as flexible as your plans

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

TrueAlarm Analog Sensing

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Integrated Security Solutions

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

Intelligent Single Loop Fire Alarm Control Panel

Multi-Point Peripherals

Fire Detection Systems Intelligent detection. Superior protection.

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Intelligent 2 & 4 Loop Fire Alarm Control Panels

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

FPA 1000 Analog Addressable Fire Panels

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

B and G Series Integrated Security Solution

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

intelligent solutions

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

A World of Solutions

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

DS7400Xi Addressable Control/ Communicator

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

INTELLIGENT FIRE ALARM CONTROL PANEL

TrueAlarm Smoke Detectors

Designed for integration. B Series and G Series Control Panels

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Solution F2. Fire Alarm Control Panels one step ahead.

CATALOG NUMBER. Features. Description

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Notification Appliance Circuit Module

Conventional Detectors

Multi-Point Peripherals

Integrated Security Solutions

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

FPA 1000 Analog Addressable Fire Panels

Advance American Products & Services

Addressable Detectors & Bases

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

Innovative protection that combines power and flexibility

LC4 Wide Angle Ceiling Loudspeaker Most compact. Widest impact.

ARCHITECT AND ENGINEER SPECIFICATIONS

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

ALK-V PHOTOELECTRIC SMOKE SENSOR

Consultant Specification AGILE Wireless Fire Detection System

FCP 320/FCH 320 Conventional Automatic Fire Detectors

FAAST. Fire Alarm Aspiration Sensing Technology

Addressable Fire Alarm Control Panel

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Intelligent Detection Devices

A World of Solutions in Fire Protection Systems

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Open-area Smoke Imaging Detection (OSID)

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Detection and Control Components

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

FAAST. Fire Alarm Aspirating Sensing Technology

Laptop / PC Programming Manual

TrueAlarm Analog Sensing

Multiple Input and Output Modules

Aspir A ation spir P R O D U C T S

FMR Installation Instructions. Addressable Fire System Controller

Installation Instructions Model HZM

Fire Product Catalog

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

TrueAlarm ES Analog Sensing

Interface and EOL Modules 8

SECTION FIRE ALARM SYSTEMS

Integrated Security Solutions. B and G Series Control Panels

Intelligent addressable fire alarm control panel

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Multiplex Eight Input Remote Modules

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

AX Series INTELLIGENT FIRE ALARM CONTROL PANEL INSTALLATION & OPERATION MANUAL ( AND )

good things in small packages

AND ARCHITECT SPECIFICATIONS

GEMC-FW-SLC FIRE SIGNALING LINE CIRCUIT MODULE INSTALLATION INSTRUCTIONS

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Transcription:

Quick Selection Guide Analog Addressable Fire Systems www.boschsecurity.com February 2018

A focused direction in fire protection With features that enable easier programming, installation and system management, the FPA-1000-V2 offers a wealth of benefits for both installers and end users. Plug-and-play installation Networking module mounts to the panel slot, requiring less wiring and no need for separate power and supervision. Remote programming & diagnostics A set of interactive Web pages provide instant access to important system functions, such as status, programming, diagnostic tools and test data. This unique feature enables programming and diagnostic cababilities using any browser-enabled device, streamlining installation and reducing time required for servicing the system. IP-based reporting Built-in Bosch Conettix IP technology communicates over local or wide area networks for faster alarm reporting and reduced costs. Integrated gas detection The first combination panel listed for both fire and carbon monoxide (CO) alarm. Complies with CO regulation requiring this hazardous gas be monitored and reported. Enhanced safety and efficiency Extra-large buttons allow operation of the keypad control while wearing protective gloves. More points, more protection Networking capbilities support more than 2000 addressable points in one system for campuses or other large commercial environments. All connected panels can easily be programmed and controlled via any panel. Suited to a wide range of applications The FPA-1000-V2 Panel now offers networking capabilities to support a wide variety of medium to large applications: Retail - single-building applications Schools and Universities Apartment Buildings Manufacturing plants Warehouses Office Complexes Military Bases Government Installations Healthcare Facilities Analog Fire Systems 2

The Analog 440 Detector family is an innovative addition to Bosch s expanding fire systems portfolio. These advanced analog addressable detectors feature Dual Ray Technology and Intelligent Signal Processing setting the standard for reliable fire detection and reduce unwanted alarms. Multicriteria and multisensor fire detection Multicriteria detectors better distinguish between fire and non-fire conditions to reduce unwanted alarms in areas with challenging environmental conditions. The 440 Detector family gives you a choice of heat, optical smoke, or a combination of optical smoke and heat. And, our most advanced model represents a step forward for the fire detection industry a multicriteria detector that identifies the presence of smoke, heat and carbon monoxide (CO) for maximum reliability. Detect even the smallest particles Intelligent Signal Processing Each detector features Intelligent Signal Processing (ISP), which uses a sophisticated, high speed microprocessor to analyze signals from each sensor. A complex algorithm ensures the sensor pattern matches that of a real fire scenario to provide immunity against possible unwanted alarm sources. This advanced technology significantly reduces unwanted alarm rates and provides more accurate fire detection, while also achieving faster recognition of different types of fires. The dual-optical variants in the 440 detectors use Bosch s Dual Ray Technology for even greater precision. Dual Ray Technology determines smoke density and particle size by comparing the intensity of scattered light from the differing wavelengths of two LED sources, one infrared and one blue. Bosch s powerful fire-detection algorithm provides exceptional differentiation between smoke particles and other particles like dust and steam that can cause a false alarm in other detectors. As a result, the Dual Ray detectors provide earlier, more reliable fire detection and produce fewer unwanted alarms. Reliable, affordable performance The 440 Detector family features a unique self-monitoring feature. If sensor functionality is not detected, a trouble message is generated and reported back to the panel. This helps ensure each area of your facility is always being monitored. In addition, a triple-color LED indicates status, including normal, trouble or alarm. Analog Fire Systems 3

Analog 440 Detector Family Dual- Description Photoelectric Heat MultiSensor MultiCriteria Photoelectric MultiSensor MultiCriteria Description Standard Base Isolator Base Control type number (CTN) FAP-440 FAH-440 FAP-440-T FAP-440-TC FAP-440-D FAP-440-DT FAP-440-DTC Control type number (CTN) FAA-440-B4 FAA-440-B6 FAA-440-B4 ISO FAA-440-B6 ISO Optical Sensor Single Single Single Dual Dual Dual Indictor LED No Multicolor Thermal Sensor Chemical (CO gas) sensor Dimensions 4-inch (-B4) 4.3 x 0.94 in. (10.9 x 2.4 cm) 4.3 x 0.94 in. (10.9 x 2.4 cm) Smoke Sensitivity Heat Sensitivity 135 to 194 F (57 to 90 C) 135 F (57 C) 135 F (57 C) 135 F (57 C) 135 F (57 C) Dimensions 6-inch (-B6) 6.6 x 0.94 in. (16.8 x 2.4 cm) 6.6 x 0.94 in. (16.8 x 2.4 cm) Rate-of-Rise Programmable Communication SLC loop SLC loop SLC loop SLC loop SLC loop SLC loop SLC loop Address Range 1 to 254 1 to 254 1 to 254 1 to 254 1 to 254 1 to 254 1 to 254 Addressing Method Rotary Switch Rotary Switch Rotary Switch Rotary Switch Rotary Switch Rotary Switch Rotary Switch Current Draw - Alarm 6 ma 6 ma 6 ma 6 ma 6 ma 6 ma 6 ma Current Draw - Standby 0.17 ma 0.17 ma 0.17 ma 0.17 ma 0.17 ma 0.17 ma 0.17 ma Operating Voltage 24-41 VDC 24-41 VDC 24-41 VDC 24-41 VDC 24-41 VDC 24-41 VDC 24-41 VDC Max. Line Resistance 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω Wiring: 18 AWG 16 AWG 14 AWG 12 AWG Remote Indicator Environmental Rating IP 42 IP 42 IP 42 IP 42 IP 42 IP 42 IP 42 Relative Humidity < 95% < 95% < 95% < 95% < 95% < 95% < 95% Operating Temperature ** Housing CYCOLOY / ABS CYCOLOY / ABS CYCOLOY / ABS CYCOLOY / ABS CYCOLOY / ABS CYCOLOY / ABS CYCOLOY / ABS Max. Airflow Indictor LED Multicolor Multicolor Multicolor Multicolor Multicolor Multicolor Multicolor Dimensions 4.4 x 1.5 in. (11.2 x 3.8 cm) 4.4 x 1.5 in. (11.2 x 3.8 cm) Available Not available ** FAH-440: If the sensitivity temperature is programmed within a range of +175 F to +249 F (+79.4 C to +120.6 C), the maximum installation temperature is +150 F (+66 C) Analog Fire Systems 4

Analog 325 Detector Family Description Photoelectric Photoelectric Heat Duct Description Standard Base Isolator Base Control type number (CTN) FAP-325 FAP-325-V2F FAH-325 FAD-325-B2F (1) FAD-325-V2F-R (2) Control type number (CTN) FAA-325-B4 FAA-325-B6 FAA-325-B6S Optical Sensor Ionization Sensor Thermal Sensor Chemical (CO gas) Sensor Indictor LED No No Dimensions 4-inch (-B4) Dimensions 6-inch (-B6) 4 x 1.5 in. (10 x 3.8 cm) 6 x 1.5 in. (15.2 x 3.8 cm) 5.9 x 1.3 in. (15 x 3.3 cm) Smoke Sensitivty 0.88 to 3.75%/ft 0.5 to 3.80%/ft 0.90 to 2.65%/ft Heat Sensitivity 135 to 150 F (57 to 66 C) Rate-of-Rise Communication SLC loop SLC loop SLC loop SLC loop Address Range 1 to 127 1 to 254 1 to 127 Addressing Method Handheld programmer Handheld programmer Handheld programmer Handheld programmer Current Draw - Alarm 8 ma 8 ma 9 ma 8 ma (1) / 55 ma (2) Current Draw - Standby 0.39 ma 0.39 ma 0.35 ma 2 ma (1) / 10 ma (2) Operating Voltage 24-40.7 VDC 22.9-39.5 VDC 24-40.7 VDC 17-41 VDC Max. Line Resistance 50 Ω 50 Ω 50 Ω Wiring: 18 AWG 16 AWG 14 AWG 3900 ft (1188 m) 6200 ft (1889 m) 10000 ft (3048 m) 3900 ft (1188 m) 6200 ft (1889 m) 10000 ft (3048 m) 3900 ft (1188 m) 6200 ft (1889 m) 10000 ft (3048 m) Remote Indicator Environmental Rating Indoor only Indoor only Indoor only Indoor only Relative Humidity < 95% < 95% < 95% < 95% Operating Temperature (0 to 37.8 C) (0 to 37.8 C) (0 to 37.8 C) Housing ABS Blend ABS Blend ABS Blend ABS Blend Max. Airflow Indictor LED Yes Yes Yes Yes Dimensions 3.94 x 1.5 in. (10 x 3.8 cm) 3.94 x 1.5in (10 x 3.8 cm) 3.94 x 1.5 in. (10 x 3.8 cm) 9 x 7.3 x 2.3 in. (23 x 18.4 x 5.7 cm) Available Not available Analog Fire Systems 5

Modules & Accessories FPE-1000-NE Class A Ethernet Networking Card FMR-1000-RCMD Remote Command Center FPE-1000-NF Network-to-Fiber Networking Card FPP-RNAC-8A-4C Remote Notification Appliance Circuit Power Supply FPE-1000-NW Network-to-Wired Networking Card D7030X LED Annunciators D7030X-S2 Annunciator-2-Supervisory D7030X-S8 Annunciator-8-Supervisory FPE-1000-CITY City Tie Plug-in Module D7032 Eight-zone LED Annunciator Expander FPE-1000-SLC Signaling Line Circuit Plug-in Module D7035 Octal Relay Modules D7035B Mux octal relay fire box FMR-1000-RA Remote Annunciator D7048 / D7048B Octal Driver Modules Analog Fire Systems 6

Modules & Accessories FLM-325-2I4 Dual Input Monitor FLM-325-IM Contact Module FLM-325-2R4 Dual Relay Module FLM-325-ISO Short Circuit Isolator FLM-325-2R4-2A Dual Relay Module 2 AMP FLM-325-2R4-2AI Dual Relay Module 2 AMP with Isolator FLM-325-2R4-8A Dual Relay Module 8 AMP FLM-325-2R4-8AI Dual Relay Module 8 AMP with Isolator FLM-325-N4 Supervised Output Modules FLM-325-NA4 Supervised Output Modules (CL.A/B) FLM-325-NAI4 Supervised Output Modules (CL.A/B W/I) FLM-325-CZM4 Conventional Zone Module FMM-325A / FMM-325A-D Analog Manual Stations FLM-325-I4 Contact Monitors 4-inch D5070 Analog Device Programmer FLM-325-I4-A Contact Monitors 4-inch Class A FLM-325-I4-AI Contact Monitors 4-inch Class A with Isolator Analog Fire Systems 7

A Tradition of Quality and Innovation For over 125 years, the Bosch name has stood for quality and reliability. Bosch is the global supplier of choice for innovative technology, backed by the highest standards for service and support. Bosch Security Systems proudly offers a wide range of security, safety, communications and sound solutions that are relied upon every day in applications around the world, from government facilities and public venues to businesses, schools and homes. Bosch Security Systems To learn more about our product offering, please visit www.boschsecurity.com Bosch Security Systems, 2018 Modifications reserved BFIQG_FPA1000-ADDR_v20180214