Harvey Chemiclave 5000 Owner And Operator Guide

Similar documents
PERFORM Operating Document

HydroFlux Welder Torch System T0-102 / T0-103

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

Harvey Chemiclave EC5500/EC6000 Sterilizers

ALL-AMERICAN PORTABLE OTERILIZERO. Your ally agaenst enfecteon sence Lions Dental Supply To Order Call


Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy

PREFERENCE ICC. A Complete System For Efficient Sterilization

GIRTON CABINET WASHER MODEL 794A

Operating / User Manual

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

OPERATION AND MAINTENANCE MANUAL

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Harvey Chemiclave EC Series Sterilizers

FRYMASTER TCF. Chicken Fryer

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

CLEANING INSTRUCTIONS

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

May 26, 2006, /2, Supersedes Technical Bulletin Group 87 number 03-01, dated May 13, 2003 due to updated treatment procedures.

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

Cleaning & Sterilization

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

STERITITE INSTRUCTIONS FOR USE

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Table of Contents. English

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

Manual Page 1 of 8. Manual. Laboratory autoclave

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Enteral Pump Instructions for Use To Assemble When the low

Best practices in Cleaning and Safety

Ultrasonic Humidifier

HF345 S9 Operators Manual

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

When you sterilize an instrument set, you know what the standards are.

Filtration. General Instructions

reference ICC A complete system for efficient sterilization

S M AN U AL. For The Dog Hut. Warmer Model Numbers: 8020 (120v) 8220 (220v)

Home Medical Equipment Oxygen

Cavitator Ultrasonic Cleaners

I N S T R U C T I O N S

FLASH PAK STERILIZATION CONTAINER SYSTEM

Homeowner s Installation Instructions & Operating Manual

HA SERIES. CVap Holding Cabinet Owner s Manual

US Filtermaxx. 200,000 BTU Waste Oil Burner

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Housekeeping. Note. Areas that are not covered under contractor services must adhere to the same cleaning standards as specified in this section.

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

Stanfield School District Cleaning Standards

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

OPERATING INSTRUCTIONS KSG 40/60-2 KSG 50/70-2 KSG 50/80-2 KSG 50/95-2

Superior Spa with Aqua-Aire

User Manual J841Q. Magnetostrictive Scaler / Polisher Combo Unit. Jorgensen Laboratories Tel: Fax:

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

The future is bright. And clean. And fully automated.

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

5KEK1222A W A_v05.indd 1 7/10/15 1:20 PM

By Silver King Refrigeration, Inc.

The Do's and Don ts in the Instrument Sterilisation Process

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

INSTALLATION & OWNERS MANUAL

KEY OPERATOR STUDY GUIDE

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

EZ9Plus & EZ11Plus Instructions on: Operating

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

Series 3 + Thank you for using the EOGas 3 sterilization system.

AUTOMATIC STERILIZERS

Product Identification

Cleaning Schedules for Childcare Facilities. Management of Infectious Disease in Childcare Facilities and Other Childcare Settings

HYGIENE AND SANITATION

Important Safeguards. Save these instructions for future reference. (continued on next page)

Cavitator Ultrasonic Cleaner Instruction Manual

Address of your installer

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Theory of Operation: M9/D & M11/D

N2736/1017 HU-FRIEDY. install the new unit, follow the instructions above for installing a new product.

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

8 LITRE URN. Instruction Booklet. Please read these instructions carefully and retain for future reference

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Transcription:

Is Happy To Present You With This Free Copy Of The Harvey Chemiclave 5000 Owner And Operator Guide Be sure to look to us when it is time to order parts and supplies for your Chemiclave Please Note: Even though we give this to you free of charge, This is NOT a free e-book! You are entitled to keep one copy on your computer and to print out one copy only. Printing out more than one copy or distributing it electronically is prohibited by international and USA Copyright laws and would subject the purchaser to penalties of up to $100,000 PER COPY distributed Copyright 2009 By AllClaveParts.com

Harvey Chemiclave 5000 Owner And Operator Guide Operating Instructions Filling and Checking Solutions The filling opening is located on top of the Chemiclave (see figure 1 below). The dust cover should be removed only for filling or checking solution level. With the control knob in the "Depressurize" position, fill the solution reservoir with approximately 500 ml of Vapo Steril. The level of solution may be determined visually. A measuring cup is included for your convenience. Since each cycle of the Chemiclave uses 15.7 ml of Vapo- Steril Solution, refilling of the solution reservoir is required after approximately 30 cycles. The "Solution: light (see figure 1 below) signals when the solution reservoir needs refilling. When the solution reservoir is empty, the system will not build pressure and refilling with Vapo-Steril is necessary. The solution reservoir may be refilled at any time, whether the Chemiclave is hot or cold. If the solution reservoir is empty, turn the control knob to "Depressurize" before refilling (see figure 1 below) Before refilling solution reservoir, dispose of exhausted solution by removing condensate tray (see Figure 1) and discarding contents. The condensate is contaminated and chemically altered and must not be reused. IF REUSED, CONDENSATE WILL NOT STERILIZE AND MAY DAMAGE YOUR CHEMICLAVE.

Activating Chemiclave Connect the Chemiclave to 115 Volts, 60hz only. Turn on the power switch (see figure 1 below). Two lights (see figure 1 below) indicate your Chemiclave is functioning properly. The "Power" light will remain on until turned off at the end of the day. The "Temperature" light will remain on up to 15 minutes during the initial heating period. Your Chemiclave is designed to operate all day with minimal power consumption (only 500 watts, as against 1000 to 1250 watts for most other units). To save valuable time, leave it on to avoid "preheating" for each load. When the "Temperature" light goes out initially, the Chemiclave is ready for use. After initial start-up, the "Temperature" light will illuminate intermittently, as the thermostat automatically maintains the optimum temperature for sterilization (132 degrees c). NO MANUAL ADJUSTMENTS ARE NECESSARY TO MAINTAIN THIS TEMPERATURE. Preparing Items For Sterilization Because of the possibility of transmitting micro-organisms from patients to professional personnel, contaminated instruments should be handled carefully. Hand-Scrubbing of sharp instruments should be avoided where possible and an ultrasonic cleaning device employed for this purpose. All Instruments should be cleaned of blood, debris or extraneous material before being placed in the instrument tray. Upon completion of the cleaning process, instruments must be thoroughly rinsed in cold running water to remove any residue of ultrasonic solution or soap and then towel dried. INCOMPLETE RINSING MAY RESULT IN THE ACCUMULATION

OF SOAP ASH AND FOREIGN DEBRIS IN THE INSTRUMENT TRAY OR STERILIZATION CHAMBER. Small objects such as burs and needles or items difficult to towel dry should be dipped in Vapo-Steril after rinsing to eliminate water. Handpieces should be cleaned according to manufacturer's instructions before sterilization. Lubricate handpieces according to manufacturer's instructions following the sterilization cycle. Use only clean, preferably sterile oil. Handpieces may be placed in the tray with other instruments. If storage of sterile instruments is desired, sterilize in Harvey Sterilization Indicator Bags. These bags permit penetration by the chemical vapor, but preclude contamination by air-borne bacterin. AVOID HEAVY OR MULTIPLE TIGHTLY WOVEN WRAPPINGS OR SEALED CONTAINERS. FOR STERILIZATION, CONTENTS MUST BE EXPOSED TO THE CHEMICAL VAPOR. Sterilizing Line the instrument tray with a Harvey Sterilizer Tray Liner and place items thereon. Close and latch the door. Turn the control knob (see figure 1 below) to "Pressurize". It is not necessary tp turn th "Time" control since the 20 minute cycle time is set automatically. The automatic cycle may be overridden by turning the "Time" control to other than 20 minutes. The sterilization cycle is automatically controlled. Timing for 20 minutes will not begin until the chamber is pressurized to 20 psi. This automatic feature insures that each chamber load, regardless of size, will be exposed to the chemical vapors for at least 20 minutes at optimum pressure and temperature. Because of the chemical action of Vapo-Steril, the

sterilization cycle begins upon admission of solution into the heated chamber. The sterilization cycle consists of two phases: The condensation phase (0-20 pounds pressure) and the vaporization phase (20-40 pounds pressure). During the condensation phase, pressure rise time will vary depending on the number and size of items being sterilized. At the conclusion of the sterilization cycle, a buzzer will sound and the "Sterile" Light will illuminate (see figure 1 below). Accordingly, it is not necessary to observe the pressure indicator gauge during the sterilization cycle. Completing The Cycle BE CERTAIN CONDENSATE TRAY IS FULLY INSERTED IN PLACE TO PREVENT CONDENSATE SPILLAGE. When the Timer Buzzer and Sterility Indicator Light (see figure 1 below) signal completion of the sterilization cycle, turn the control knob to "Depressurize" (see figure 1 below). An efficient system of coils assures condensation of virtually all chemical vapor in the chamber in approximately 25 seconds. AS A SAFETY FEATURE, THE DOOR IS DESIGNED TO BE OPENED ONLY AFTER THE CHAMBER IS EXHAUSTED. The contents may be immediately removed. NO DRYING IS REQUIRED. Helpful Suggestions Your Chemiclave is unsurpassed as an instrument for sterilization in the professional office, clinic or hospital. Treat it accordingly. Following are useful comments: Parts The Door Gasket should be replaced when damage, deterioriation, or wear may prevent proper seal. To maximize the life of the the gasket, leave door closed but unlatched when the Chemiclave is not in use. Maintenance

Exterior metal surfaces of your Chemiclave should be cleaned daily with Harvey Metal Polish. Care should be exercised to prevent polish from entering valve and timer stem openings in the solution reservoir. Because of the detergent action of Vapo-Steril, debris from improperly cleaned instruments may accumulate in the chamber and instrument tray. Harvey Metal Cleaner should be used periodically as needed to remove such debris. AT LEAST WEEKLY CLEANING IS RECOMMENDED.