006e3 Instruction Sheet

Similar documents
Instruction Sheet. ECM High-Efficiency Circulator. SUPERSEDES: January 24, 2016 EFFECTIVE: March 29, 2016

00e series VT2218 Instruction Sheet

00e series VR1816 Instruction Sheet

00e series VR1816 Instruction Sheet

Instruction Sheet. ECM High-Efficiency Circulator

Viridian VR1816 Instruction Sheet

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

CHUGGER PUMP Chugger Max Models

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

LS Condensate Removal Pump Installation, Operation and Service Instructions

Instruction Sheet. 1915e ECM Circulator SUPERSEDES: NEW Effective: January 21, Plant ID No

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Astro 2 circulator models. Installation and operating instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Guide

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

E.2 series high efficiency circulator. Installation and operating instructions

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Astro Express 2 - Hot Water Delivery System

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTION In-Ground Color Changing

Installation Instructions

Installation and operating instructions. E.2 Series high efficiency circulator

LC Series - Light Commercial Pump Station Installation and Operation Manual

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Installation Instructions If you have questions, call or visit our website at:

Allcan TM Installation Manual

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

1 Declaration of conformity

52 BERKSHIRE CEILING FAN

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

520 Series. TankMixer water heater tank mixing valve NA Function

52 SAN LUCAS CEILING FAN

AGA TOTAL CONTROL. Model No. - TC3

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

LIMITED LIFETIME WARRANTY

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

52 BAYTOWNE CEILING FAN

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Taco 00 Series Cartridge Circulators

48 TAYLOR CEILING FAN

520 Series. AngleMix Thermostatic mixing valve NA Function

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

ECO1ZN3P, ECO2ZN4P ECO

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

52 STRATHMERE CEILING FAN

Torrena 42 Ceiling Fan

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Plastic Housing Plastic Housing Stainless Housing SM /8" 3 3/8"

Camarillo 52 Ceiling Fan

52 BARSTOW CEILING FAN

Please Read and Save These Instructions.

52 CEILING FAN. Owner s Manual Models #50336, 50337

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Illuminated Stopper Station Push Button

Lumination TM Volumetric Retrofit Kit

MP-MBA-45T-1/60T-1 / 75T-1

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

UNI 321. User s Guide

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION INSTRUCTIONS

Installation Instructions

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Installation and Operating Instructions

Lumination TM Controls Accessory LPL Series Controller Box

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

INSTALLATION MANUAL CT-200

Food Waste Disposer Instruction Manual

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

Nachi Series TM Z6957-XL

INSTALLATION & OPERATING INSTRUCTIONS

Technical Manual for the Strobe - SM87 HXB

TECHNICAL INSTRUCTIONS

INSTRUCTION BOOK FOR. Professional Electrol

Transcription:

006e3 Instruction Sheet 102-533 SUPERSEDES: NEW EFFECTIVE: February 27, 2018 Plant ID No. 001-5005 DESCRIPTION: The 00e series 006e3 is a 3-setting wet rotor circulator with an ECM, permanent magnet motor. A simple dial adjusts operating speed to Low, Medium or High settings. Its high-efficiency motor reduces power consumption by up to 85% compared to equivalent AC permanent split capacitor circulators. APPLICATION: Maximum operating pressure: 150 psi (10 bar) Maximum water temperature: 203 F (95ºC) Electrical specifications: Voltage: 110-120V, 50/60 Hz, single phase Maximum operating power: 44W Maximum amp rating: 0.54 Equipped with an engineered composite casing with 1" union connections Use on open loop potable hot water circulation systems or closed loop hydronic heating systems Not suitable for chilled water systems Taco circulator pumps are for indoor use only employer uniquement a l interieur Acceptable for use with water or maximum of 50% water/glycol solution FEATURES: Operating modes - Low, Medium or High - Pre-marked 003/006 performance point references - Min/Max infinitely variable fixed speeds Multi-color LED display showing operating mode and error code diagnostics Union connection, composite casing Optional 1/2" & 3/4" union fitting sets available - sweat, npt or press connections (sold separately) Dual electrical knockouts and 6 stranded wire leads for easy wiring (006e3LC model includes 6' power cord) Double insulated - no ground-wire required Whisper quiet operation SureStart - automatic unblocking and air purging mode INSTALLATION: ECM High-Efficiency Circulator Figure 1: WARNING: Follow all local plumbing and electrical codes when installing this product. AVERTISSEMENT: Respectez tous les codes de plomberie et d'électricité locaux lors de l'installation de ce produit. CAUTION: To ensure all plumbing system components are protected from the damaging effects of water hammer, be sure an approved water hammer arrestor is installed in the system per locally recognized National plumbing codes. ATTENTION: Pour vous assurer que tous les composants du système de plomberie sont protégés contre les effets dommageables du coup de bélier, assurez-vous qu'un parafoudre approuvé est installé dans le système conformément aux codes de plomberie nationaux reconnus localement. WARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications. AVERTISSEMENT: Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas été étudiée pour ces applications. CAUTION: The addition of petroleum based fluids or certain chemical additives to systems using TACO equipment voids the warranty. Consult factory for fluid compatibility. ATTENTION: L'ajout de liquides à base de pétrole ou de certains additifs chimiques à des systèmes utilisant un équipement TACO annule la garantie. Consultez le fabricant pour connaître la compatibilité de liquides. CAUTION: Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation and flashing. Premature failure may result. Adjust expansion tank pressure to equal fill pressure. A larger size expansion tank may be required. ATTENTION: Des installations à des altitudes de plus de 1600 mètres doivent présenter une pression de remplissage plus élevée de 20 psi au minimum afin d'éviter toute cavitation ou flashing de la pompe. Une défaillance prématurée peut en résulter. Réglez la pression du réservoir d'expansion de façon qu'elle soit égale à la pression de remplissage. Un réservoir d'expansion d'une taille supérieure peut être nécessaire. 1

Figure 2: Typical Installation for Hot Water Recirculation Systems Water Heater Recommended Purging Steps: 1. Open fixture at highest point in system 2. Open all isolation valves 3. Once system is filled, close the fixture at the highest point in the system 4. Close isolation valve on pump discharge 5. Open drain valve on pump discharge until all remaining air has been purged 6. Close drain valve 7. Operate pump until all remaining air is purged from bearing chamber 2

Figure 3: Typical Installation for Zoned Hydronic Heating Systems Boiler Supply (Option No. 1) Boiler Return (Option No. 2) KEY: VI, V2, V3 = SHUT-OFF ISOLATION VALVE P = TACO CIRCULATOR FF = FAST FILL BOILER FEED VALVE PV4 = PURGE VALVE FC = FLOW CHECK VALVE RECOMMENDED PURGING STEPS: 1. CLOSE V1, PV4, V2 2. OPEN V3 3. OPEN FF VALVE 4. OPEN V2, PV4, TO PURGE LAST ZONE FIRST (ZONE 3) 5. CLOSE FF VALVE 6. CLOSE V2, PV4 7. REPEAT STEPS 1 TO 6 FOR EACH ADDITIONAL ZONE, PURGE ZONE 1 LAST 8. OPEN V1 WHEN ALL ZONES ARE PURGED 9. ADJUST SYSTEM TO DESIRED OPERATING FILL PRESSURE IF REQUIRED 3

1. Location: The circulator can be installed on the supply or return side of the water heater or heat source. See Figures 2 & 3, on page 2 for preferred locations. 2. Mounting position: Circulator must be mounted with the motor in the horizontal position. See diagrams below for acceptable motor mounting orientations. 3. Install the union tailpiece fitting set (sold seperately) best suited for your system piping. (See Union Fitting Options chart on page 7). CAUTION: Install fittings to system piping before connecting the circulator to avoid damaging the pump s composite casing. 4. Install circulator by attaching pump casing to each union tailpiece fitting. Tighten union nut onto circulator threading (being careful not to overtighten) to complete the installation. CAUTION: Only use union gaskets provided with union fitting sets or leaks may result. Warranty will be void. ACCEPTABLE MOTOR MOUNTING POSITIONS Figure 4: Always install with motor in horizontal orientation. Always install with motor in horizontal orientation. Position electrical junction box at 9 o clock for best viewing orientation. Pump casing may be rotated to change flow direction. Locate the arrow on the casing body to determine flow direction. Figure 5: Spin casing to change flow direction. CASING ROTATION Figure 6: Do not detach motor frame from pump casing. Simply spin casing to the proper flow direction. X To rotate the pump casing, remove the 4 motor screws using a 5/32" (4 mm) allens wrench. When rotating pump casing position, DO NOT detach motor housing from the casing. Damage to the casing O-ring and leakage may result. Simply spin casing to the proper flow direction desired as shown in Figure 4 and Figure 5. Reattach the 4 screws. Be sure motor is positioned correctly and is seated evenly to prevent leakage or damage to O-ring. Tighten motor screws evenly to 25-33 inlbs torque. CAUTION: To reduce the possibility of noise transmission, be sure to add vibration dampeners to piping when mounting circulator to wall or floor joists. ATTENTION: Pour réduire la possibilité de transmission de bruit, veillez à ajouter des amortisseurs de vibration à la tuyauterie lors du montage du circulateur sur des chevêtres de mur ou de plancher. 5. Filling the system: Fill the system with tap water or a maximum of 50% propylene-glycol and water solution. The system must be filled before operating the circulator. The bearings are water lubricated and should not be allowed to operate dry. Filling the system will result in immediate lubrication of the bearings. It is always good practice to flush a new system of foreign matter before starting the circulator. See page 2 for recommended air purging steps. WARNING: Risk of electric shock. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Follow all local electrical and plumbing codes. AVERTISSEMENT: Risque de choc électrique. Pour réduire le risque de choc électrique, veillez à ce qu'elle soit raccordée uniquement à un réceptacle de type mise à la terre proprement mis à la terre. Respectez tous les codes de plomberie et électriques locaux. WARNING: Use supply wires suitable for 90 C. AVERTISSEMENT: Employer des fils d alimentation adeqauts pour 90 C. WARNING: Disconnect power when servicing. CAUTION: Use flexible conduit only. Not for use with rigid conduit. WARNING: SERVICING OF DOUBLE-INSULATED APPLIANCES. A double-insulated appliance is marked with one or more of the following: The words DOUBLE INSULATION or DOUBLE INSULATED or the double insulation symbol (square within a square). In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added. Servicing a double-insulated appliance requires extreme care and knowledge of the system, and should be done by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to the parts they replace. 4

WIRING DIAGRAM 6. Wiring the circulator: Disconnect AC power supply. Remove terminal box cover. Attach a wiring connector into knockout hole. Use flexible conduit only. Connect Line/Hot power to the black lead, Neutral to the white lead. See wiring diagram. WIRE NUT WHITE Note: If pigtail leads provided are not used, be sure to trim field wire to a strip length of.25" (+/-.025") to prevent exposed wire causing a short at the terminal plug. Connect line and neutral to green terminal plug as shown in diagram. Depress the spring tab with a small screwdriver to insert wire into plug. Release tabs to complete connection. The 006e3 is a double insulated circulator, no grounding wire is necessary. Replace terminal box cover. NEUTRAL LINE BLACK L N No ground wire is required. Green Terminal Plug Spring Tabs 7. Start the circulator: When purging the system, it is recommended to run the circulator at full speed long enough to remove remaining air from the bearing chamber. This is especially important when installing the circulator in the off-season. CAUTION: Never run the circulator dry or permanent damage may result. ATTENTION: Ne laissez jamais le circulateur tourner à sec, des dommages permanents peuvent en résulter. Full Speed Operation: To run the pump at full speed during the fast fill, start-up and purge process, rotate dial to MAX speed setting. To return to the normal operating mode, turn dial to desired speed setting. 8. Programming your 006e3 circulator: Note: The 006e3 is factory-programmed for Medium speed operating mode. If this is your desired operating mode, no programming changes are required. If flow velocity noise develops, turn dial counter-clockwise to reduce pump speed until noise disappears. 006e3 Operating Modes 3 Fixed Speed Settings ( ) - Low, Medium, High Pre-marked 003/006 equivalent settings Min-Max infinitely variable fixed speed settings for fine tuning To change operating speed settings: Modify the performance of the circulator as needed by rotating the programming dial using a flat screwdriver. A blue LED will illuminate when the circulator is powered on. The LED will flash each time mode is changed. The selection of the right performance curve depends on the characteristics of the system and the actual flow and head requirements. See 006e3 Performance Curves and Setting Selection Guide on page 7 to determine best speed setting for the system. CAUTION: Do not attempt to remove LED panel from circulator. Serious damage to circulator electronics may result. ATTENTION: N'essayez pas de retirer le panneau de LED du circulateur. Des dommages sérieux à l'électronique du circulateur peuvent en résulter. 5

9. Troubleshooting the error codes: Listed below are potential diagnostic error codes which will appear on the LED display in case of a malfunction. FAULTS CONTROL PANEL CAUSES REMEDIES The circulator is noisy Loud noises of water circulation LED on LED on Flashing white LED Suction pressure is insufficient - cavitation Presence of foreign bodies in the impeller Air in the system Increase the system suction pressure within the permissible range. Disassemble the motor and clean the impeller. Vent the system. Repeat fill and purge steps. LED on The flow is too high Reduce the pump speed. Lack of power supply Verify voltage value of the electric plant. Verify the connection of the motor. One fuse in the installation is blown Verify the fuses of the plant. Circulator is not running although the electrical power supply is switched on LED off The circulator is defective Overheating Replace the pump. Let the pump cool down for some minutes. Then try to restart it. Verify that the water and ambient temperature are within the indicated temperature ranges. Disassemble the motor and clean the impeller. See unblocking procedure below. LED red The rotor is blocked Insufficient supply voltage Verify that the power supply matches the data on the name plate. Building does not get warm. LED on The circulator performance is too low Increase the suction head. Increase speed. Unblocking Procedure: A red light in the LED indicates the circulator rotor is blocked or sticking. Turn the selector to the position MAX, disconnect and connect power supply to start the automatic release process. The circulator makes 100 attempts to restart (process lasts approximately 15 minutes). Every restart is signalled by a short flash of white LED light. If the blocking is not removed through the automatic release process after 100 attempts to restart, the circulator goes into standby and the LED remains solid red. Perform the manual unblocking steps described below. 1. Disconnect power supply - the warning light switches off. 2. Close both isolating valves and allow cooling. If there are no shut-off devices, drain the system so that the fluid level is beneath that of the circulator. 3. Loosen 4 motor bolts. Remove motor from casing. Carefully pull the rotor/impeller from the motor. 4. Remove impurities and deposits from the impeller and casing. 5. Reinsert the rotor/impeller into the motor. 6. Set the dial to the MAX position. 7. Connect power supply. Check for impeller rotation. 8. If the circulator still doesn t run it will need to be replaced. 6

Replacement Parts List 198-213 RP Casing O-ring 198-214 RP Wiring plug connector (green) 198-215 RP Terminal box cover (black) 198-217 RP Terminal box cover screws (5 per bag) Part # UFS-050S UFS-050T UFS-050P UFS-075S UFS-075T UFS-075P Union Fitting Options (Sold seperately) Description 1/2 sweat tailpiece set 1/2 npt tailpiece set 1/2 press tailpiece set 3/4 sweat tailpiece set 3/4 npt tailpiece set 3/4 press tailpiece set 006e3 PERFORMANCE CURVES 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q (m 3 /hr) 0.0 0.2 0.4 0.6 0.8 Q (l/s) H (ft) 16 5 H (m) 14 12 MAX 4 10 HIGH 3 Head 8 MED 6 LOW 2 4 2 MIN 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Flow 0 Q (gpm) 3 fixed speed settings ( ) (Low, Medium High) allows the installer to choose the speed and flow rate to precisely match system requirements. It also has infinitely variable speed settings between MIN/MAX to fine tune flows more precisely. Pre-marked 003/006 settings enable installers to set 006e3 to match standard 003 or 006 performance. 7

006e3 Replacement Chart TACO GRUNDFOS WILO B&G / XYLEM ARMSTRONG LAING 003 006 UP 15-18 UP 15-10 UP 10-16 Z-15 ecocirc e 3-4 ecocirc e 3-6 NBF-8, 9, 10, 12 SSF- 9, 12 Astro 225 BS Astro 225 SSU Astro 220 SSU E1 Series E3 Series LIMITED WARRANTY STATEMENT Taco, Inc. will repair or replace without charge (at the company s option) any Taco High Efficiency circulator or circulator part which is proven defective under normal use within three (3) years from the date of manufacture. In order to obtain service under this warranty, it is the responsibility of the purchaser to promptly notify the local Taco stocking distributor or Taco in writing and promptly deliver the subject product or part, delivery prepaid, to the stocking distributor. For assistance on warranty returns, the purchaser may either contact the local Taco stocking distributor or Taco. If the subject product or part contains no defect as covered in this warranty, the purchaser will be billed for parts and labor charges in effect at time of factory examination and repair. Any Taco product or part not installed or operated in conformity with Taco instructions or which has been subject to misuse, misapplication, the addition of petroleum-based fluids or certain chemical additives to the systems, or other abuse, will not be covered by this warranty. If in doubt as to whether a particular substance is suitable for use with a Taco product or part, or for any application restrictions, consult the applicable Taco instruction sheets or contact Taco at (401-942-8000). Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part. Taco reserves the right to make changes in details of design, construction, or arrangement of materials of its products without notification. TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES. ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY FOR THE DURA- TION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARAGRAPH ABOVE. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR STATUTORY, OR ANY OTHER WARRANTY OBLIGATION ON THE PART OF TACO. TACO WILL NOT BE LIABLE FOR ANY SPE- CIAL, INCIDENTAL, INDIRECT OR CONSE- QUENTIAL DAMAGES RESULTING FROM THE USE OF ITS PRODUCTS OR ANY INCIDENTAL COSTS OF REMOVING OR REPLACING DEFECTIVE PRODUCTS. This warranty gives the purchaser specific rights, and the purchaser may have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts or on the exclusion of incidental or consequential damages, so these limitations or exclusions may not apply to you. A Taco Family Company 2017 8