The National Fire Chiefs Council. Roy Wilsher Chair National Fire Chiefs Council

Similar documents
Cladding Screening Test Result

Kensington Aldridge Academy, London W10

Fire safety and high rise student accommodation

10. Fire services. 10 FIRE SERVICES p1

Grenfell Tower Inquiry

Fire Risk Management Post Grenfell

Fire Safety in Schools Post-Grenfell Fire

Lakanal House inquest: Statement from the Fire Sector Federation

Waking Watch / Common Fire Alarm. Guidance to support a temporary simultaneous evacuation strategy in a purpose-built block of flats

Scottish Building Standards and Fire Safety: A Brief Overview

Guidance to support a temporary change to a simultaneous evacuation strategy in purpose-built block of fl ats

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

Appendix 1 Fire safety and the Council s response to the Grenfell Tower Tragedy

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

Chapter 1 Test. Directions: Write the correct letter on the blank before each question.

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

DEF Fire Evacuation and Emergency Planning Criteria

Fire Risk Assessment

Environmental emergency preparedness and response

Lessons Learned from the FaçadeFiasco. Dr. Jonathan Barnett Technical Director, RED Fire Engineers

Grenfell Tower Fire. Community Safety Committee. Purpose. Recommendations That Members of the Community Safety Committee note the content of this

Fire Safety. A TUC guide for trade union activists

Fire Safety Management

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

1.7 SECTORS, GROUPS AND DIVISIONS

Universiti Tunku Abdul Rahman STANDARD OPERATING PROCEDURES

Two International Finance Centre 416m. Bank of China Tower 367m. The Center 346m. Central Plaza 374m

IN THE MATTER OF THE GRENFELL TOWER PUBLIC INQUIRY OPENING STATEMENT CS STOKES & ASSOCIATES LIMITED

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

DEPARTMENT SUMMARY. Personnel Services $ 7,780,971 $ 7,989,600 $ 7,707,680 $ 8,231,680. Operating Expenses 835, , , ,870

Emergency Evacuation. Made Simple. EVACUATION STRATEGIES - PROBLEMS & SOLUTIONS EXPLAINED Alan Oliver

Fire Risk Assessment

Thank you for your letter of 26 June regarding the Committee s scrutiny of building regulations in Scotland.

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

Resource Pack (work-in-progress) Lessons from Grenfell Policy Think Tank

Specialist Fire Safety Courses Xact Consultancy and Training Limited

False Alarm Management. Graham Simons FIA Technical Manager

Specialist Fire Safety Courses Xact Consultancy and Training Limited

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

Fire Safety Awareness Workbook

Local Rules: Fire Safety

ESSEX POLICE, FIRE AND CRIME COMMISSIONER FIRE & RESCUE AUTHORITY Essex County Fire & Rescue Service

Management Standard: Fire Safety

Fire Safety Management

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

Fire Safety Strategy

Q) What should I do if the fire alarm sounds in the building? Q) What do I do if I discover a fire?

Fire Department Orientation / Organization

Fire Risk Assessment

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Organisational Overview

Summary. Introduction

22 BISHOPSGATE Lift Evacuation Strategy

Standard Operating Procedure Ottawa Fire Services. Fire Operations- Structural Fire Incidents SUBJECT. Fire Alarm Systems (Silence/Reset) - Revised

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Fire Safety Protocol

BYLAW 5542 *******************************************************************************

I. It shall be the responsibility of the department officers to implement this operating guideline.

EMERGENCY EVACUATION PLAN

Carbon Monoxide Poisoning

Design of Fire safety in Multi Occupancy Residential Accommodation

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire risk your responsibility?

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Appendix A: US Fire Statistics Tables

Emergency Response Team Plan. Shoal Island Office

YTD. Administrator Robertson attended the Auburn Area Chamber of Commerce meeting on Tuesday, July 17 th in Auburn.

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

FIRE & SAFETY TRAINING BROCHURE

PEMBROKE PINES FIRE DEPARTMENT ISO Class 1 Department

Fire Risk Assessment Guide

Floor Warden Training

Practice Advisory 18: Fire safety design for tall buildings

ADMINISTRATOR S WEEKLY REPORT # March 2 nd through 8 th, 2015

Fire Risk Assessment Guide

FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH

- CONSTRUCTION FIRE SAFETY STANDARDS

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

Managing a flood event

Burton Hospitals NHS Foundation Trust. On: 27 April Review Date: March Corporate / Directorate. Department Responsible for Review:

PREVENTION, PROTECTION, ROAD SAFETY

CAMDEN COUNTY FIRE COORDINATOR

Firefighting operations on fire control centres F5-09 GD

UK Timber Frame Association

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

Level 5 Fire Engineering Design. Courses and qualification

Five London Hospital Fires: Report by Philip Gibbs, LFB. For internal training use only.

DMP & RISK MANAGEMENT PLAN

FINAL VERSION. Report for London Borough of Hammersmith and Fulham FIRE RISK ASSESSMENT OF WOODFORD COURT, SHEPHERD S BUSH GREEN

Fire Investigation Education & Training

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Understanding Passive Fire Protection

Building Regulation Fire Performance Requirements for Insulated Panel and Façade Systems

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

SECURITY SERVICE LEVEL AGREEMENT

Transcription:

The National Fire Chiefs Council Roy Wilsher Chair National Fire Chiefs Council

Description and location Grenfell Tower, Lancaster West Estate, London, W11 1TG 24 storey residential building Ground floor créche, nursery, youth club 129 one and two bedroom flats London Borough of Kensington and Chelsea

Grenfell Tower Tower Designed 1967 Built 1972-74 24 storeys Brutalist architecture Refurbished 2014-16 9 further flats added

Floor Plan

Resources used >200 firefighters and officers during response phase 40 pumping appliances 7 Command Units 14 Fire Rescue Units 4 Aerials 3 Urban Search and Rescue (USAR) modules 50 specialist USAR firefighters and specially trained search dogs In total, almost 700 personnel attended Grenfell Tower up to STOP message

Duration of incident Stop message was sent on 27 June 2017 at 1345 hours 13 days, 12 hours and 51 minutes after the initial call LFB Fire Investigation team members still on scene assisting MPS investigation

Number of People Rescued 65 people rescued by crews using both Standard Duration and Extended Duration breathing apparatus Extremely difficult and arduous conditions

An unprecedented incident..

Counselling and wellbeing (C&W) arrangements Red Watch (RW) attend Grenfell Tower to fight the fire and remove casualties Blue Watch on duty 0930 hours Tens of stations attended Control officers (answering 999 calls, mobilising resources) Multiple senior officers High levels of distress identified in both those attending and answering calls

What Happened Next

Grenfell Recovery Ministerial Meetings Media Disaster Victim Identification Family Welfare and Pressure on Hospitals Community Mobilisation Response of Local Authority Number of Occupants Temporary Housing Finance Other Buildings

Related Matters Data Collection other ACM Buildings 600+ Visits by Fire & Rescue Screening Tests almost 100% Failure Interim Fire Safety 22 June Fire Risk Assessment Residents, Doors, Means of Escape Compartmentation, Smoke Control Firefighting Facilities Car Parks and BBQs Temporary Communal Alarms and Fire Wardens

Related Matters Contd Camden Chalcots Estate 21 June Mad Day Saturday 24 June All NHS Buildings Data Cleansing 290 blocks, mainly London and Manchester Expert Panel 27 June

Related Matters Contd Large Scale Tests BS8414

Related Matters Contd Results Aluminium Composite Material (ACM) with Unmodified polyethylene filler (Cat. 3 in screening tests) Insulation PIR Foam Phenolic Foam Stone Wool Test 1 failed 81 Buildings Report and Advice N/A Test 2 failed 107 Buildings Report and Advice Buildings inferred to have failed where insulation unknown 38 Buildings Fire retardant polyethylene filler (Cat. 2 in screening tests) Test 3 failed 8 Buildings Report and Advice Test 7 failed 21 Buildings Report and Advice Test 4 passed 12 Buildings Report and Advice 11 Buildings Limited combustibility filler (Cat. 1 in screening tests) Test 5 passed 0 Buildings Report and Advice N/A Test 6 passed 0 Buildings Report and Advice 0 Buildings

Enquiries Etc Criminal Investigation Public Enquiry Review of Building and Fire Safety Regulations Competence Architects, Designers, Builders, Building Control, Surveyors, Fire Risk Assessors London Fire Brigade & national Fire Service Learning

Investigation Structure

Building Regulations Clause 12.7 specifically refers to insulation materials and filler materials but is now being interpreted more generally (see BCA Guidance note 18). Therefore where a building has a storey 18m or more above ground level all significant materials should be of limited combustibility (Class A2 in accordance with EN 13501-1) Option 1 Use Materials of Limited Combustibility Option 2 Testing to BS 8414-1/2 and meeting BR 135 criteria Option 3 Fire engineered assessment of cladding based on test data (Desktop) Option 4 Holistic fire engineered assessment of whole building

Next Steps Interim Letter Update Waking Watch Guidance Stay Put Fire Service Revisits Remove Cladding Supply Chain Private Sector Other Cladding Systems-High pressure Laminates (HPL), Render coatings, Fibre Reinforced Plastic/Panels Data National Fire Chiefs Council Co-ordination, Advice and Consistency