Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Similar documents
Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Owners Manual Refrigerated Air Dryer MHT SERIES

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

DRYMAX DRYMAX DRYMAX DRYMAX

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEWGATE TECHNOLOGIES, INC.

InstructIon Manual KrEs EQuIPMEnt stands

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

RNP SERIES 33 F 39 F 1 C 4 C OFF OPERATOR MANUAL

MODEL MW200 MODEL MW600 AIR DRYER

Superdryer Dehumidifiers

R100 Oil-Less Refrigerant Recovery Unit

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

VSA Series Air Dryer. User s Guide

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Horizontal Bottle Cooler Installation and Operation Manual

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PNLDII-28 Condensate Drain Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

OPERATING INSTRUCTIONS

CH250 AND CH251 CHILLERS

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDH Series Air Dryer. User s Guide

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Installation & Operation Manual Ice Cream Freezers

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

CHILLER. Operator s & Installation Manual

TORRID MARINE YACHT QUALITY Since Owner s Manual

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

MACH N-407 Heat Pump Air-Cooled Chiller

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

RPI Industries, Inc.

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

CHILLER. Model CH3000. Operator s & Installation Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

INSTRUCTIONS! DO NOT DISCARD!

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

DRYAIRE DESICCANT SYSTEM MODEL 6760

XC Portable Air Conditioning

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Desiccant Air Drying System

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

T-Series Air Conditioner T15 Model

RPI Industries, Inc.

UNDERCOUNTER DISHWASHER

Owner s Manual. Terpene Trap CF 1000

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Corrosion Dry Air Pak

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Power Pack Service Manual

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Desiccant Air Drying System

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Condensing Unit Installation and Operating Instructions

Air Dryers & After Coolers Dry Land

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Transcription:

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference. WARNING: Air treated by this equipment is not suitable for breathing without further purifi cation. Refer to O.S.H.A. standards for the requirements for breathing quality air. F-3531 & F-3532 F-3529 & F-3530 F-3528 ARROW DRYERS 745 CLARK AVE. BRISTOL, CT 06010 TOLL FREE: (877) 640-8300 Form F-0030A Revised 11/04

F-3528 1) Separator 2) Compressor 3) Expansion/Control Valve 4) Refrigerant Filter 5) Fan Motor 6) Power On Light/Switch 7) Dew Point Indicator 8) Power Cord 9) Drain Line F-3529, F-3530 1) Separator 2) Compressor 3) Expansion/Control Valve 4) Refrigerant Filter 5) Hot Gas Valve 6) Fan Motor 7) Power On Light/Switch 8) Dew Point Indicator 9) Power Cord F-3531, F-3532 1) Separator 2) Compressor 3) Expansion/Control Valve 4) Refrigerant Filter 5) Hot Gas Valve 6) Fan Motor 7) Power On Light/Switch 8) Dew Point Indicator 9) Air Inlet Temperature 10) Drain Line 1

Receiving and inspection Arrow Dryers are carefully prepared for shipment at the factory to protect them from damage in transit. Dryers are shipped F.O.B. factory. Immediately upon arrival, check the dryer for possible damage. If damage is found, report it to the carrier and file a damage claim. Check the dew point indicator gauge. If the dew point indicator gauge reads zero, it indicates a possible refrigerant leak. Notify your dealer immediately. Be sure you have the right dryer. Check the nameplate for voltage and amperage How the Air Dryer Works Compressed air enters the inlet and passes through the air-to-air heat exchanger where the air is partially cooled by the exiting cold air. Next, the air passes through a refrigerant-to-air heat exchanger where it is cooled to near the freezing point of water. As the air is cooled, it loses the capacity to hold water vapor. The water vapor condenses into water droplets and drains to the separator. Passing through the separator, air flow slows down and causes more water to condense and collect in the bottom of the separator bowl. The water is exhausted by the electronic timer drain (see figure 5). The compressed air, now at a pressure dew point of 35ºF, leaves the dryer through the air-to-air heat exchanger where it is heated by the incoming air. Location and Installation Locate the dryer indoors in a protected area where ambient temperature will range between 45ºF and 100ºF. Dryers are usually located near the compressor. Do not cycle the dryer with the compressor. If an aftercooler is used after the compressor, install the dryer downstream of the aftercooler and receiver (see figure 2). Install the dryer so that there is sufficient room around it to permit circulation of air through the refrigeration condensing unit. Allow for easy access into the dryer through the cover panel. Check the nameplate for voltage and amperage. The dryer is furnished with a 6 foot electrical cord for connection to a grounded outlet. Be sure that the compressor air passes through the dryer in the proper direction. Connect the compressed air lines to the inlet and outlet connection as marked on the cabinet. Connect the air lines with standard pipe fittings. The mechanical separator has an adjustable electronic timer drain with a 3/8 plastic drain line connection that exits through the dryer cabinet. Both the length of time that the timer drain is open and the frequency of discharge can be adjusted to accomodate for varying humidity conditions. It is recommended that a bypass line is piped around the dryer. Shutoff valves should be installed at both inlet and outlet, with another valve in the bypass line. This complies with O.S.H.A. lockout regulations and permits the dryer to be removed from the system or serviced without turning off the air supply. Typical Compressed Air Systems Figure 2 2

Dimensions F-3528 Air Dryer F-3529 & F-3530 Air Dryer F-3531 & F-3532 Air Dryer CFC-Free R-134A Specifications Model Air Flow Volts Amps LRA Max. Rerfrig Dimensions Air Weight No. H.P. CFM* RLA Fuse Charge* (Inches) Line Lbs. R-134A Length Height Width Conn. F-3528 1/4 21 115/1/60 5.3 29 15 20oz. 22 16.0 14 1 NPT 84 F-3529 1/2 30 115/1/60 5.36 30 15 1.8 Lbs 30 27.5 20 1 NPT 147 F-3530 1 50 115/1/60 16.9 78 20 2.8 Lbs. 30 27.5 20 1 NPT 187 F-3531 1.25 70 230/1/60 12.4 61 15 3.8 Lbs. 34 35.0 27.5 2 NPT 235 F-3532 1.5 105 230/1/60 16 82 35 4.5 Lbs. 34 35.0 27.5 2 NPT 280 NOTE: The air leaving the dryer is reheated to 25 F below the inlet air temperature * CAPACITY CFM BASED ON 160 F INLET, 100 PSIG & 100 F AMBIENT 3

Design Conditions The Dryer must not be cycled with the air compressor. The dryer is non-cycle and is designed to run continuously (even under light loads). If the compressed air system remains pressurized and the air compressor cycles off and on to maintain line pressure, the dryer should remain in operation to keep the air lines dry. Air Flow SCFM: The rated air flow (SCFM) of the dryer is designed for 100 PSIG. Above the rated air flow, the dew point will rise and moist air may reappear downstream. The dryer may cycle off and on under excessive load and cause compressor damage. Specifications: All specifications are based on an inlet air temperature of 180 F, an ambient temperature of 100 F, and an air pressure of 100 PSIG. The max allowable line pressure of each unit is 250 PSIG. The operating data under the design conditions is as follows on page 4. (Specifications) How to Make Minor Refrigerant Suction Pressure Adjustments (Con t) 1) Turn off or bypass the compressed air. 2) Remove the dryer cover and locate the control valve (See Figure 3 for F-3528-F-3529) (See Figure 4 for F-3530-F-3532). 3) Turn 1/2 turn at a time and wait 3-4 minutes for suction pressure to settle. a. Turn clockwise to increase pressure (temperature) b. Turn counter-clockwise to decrease pressure (tem -perature) Figure 3 Figure 4 Ambient Air Temperature: Locate the dryer indoors in a protected area where the ambient temperature will range between 45ºF and 100ºF. Note: Above an ambient temperature of 100ºF the refrigerant will rise until the dryer shuts down. Several off and on cycles under these conditions will damage the compressor. Start UP 1) On initial start-up of system check electrical connections to the dryer, as well as the air piping, so inlet and outlet piping are connected to correct ports. 2) Check panel mounted suction pressure gauge. It must show a minimum of 50 PSI or dryer may not run. 3) When ready to operate the compressed air system, the dryer should be started before air compressor is started. 4) When closing the start switch the indicator light on the front panel of dryer will show there is power to the refrigeration compressor. Refrigerant pressure gauge will drop and hold at the no load suction pressure of between 30 and 34 PSI. 5) When pressure has dropped to this level the air compressor can be started and air flow can begin. NOTE: All dryer models are designed to operate without compressed air load in order to pre-cool the heat exchanger surface. NOTE: Operation of dryer is automatic and continuous. Refrigerant compressor does not cycle off and on. Discharge of condensate through drain is automatic. To Stop To stop the unit turn start-stop switch to off position. IMPORTANT: IF IT IS NECESSARY TO PROTECT THE AIR SYSTEM DURING NORMAL SHUT-DOWN THE IN- LET SHUT-OFF VALVE TO THE DRYER SHOULD BE CLOSED TO PREVENT WET AIR FROM ENTERING AIR SYSTEM. How to Make Minor Refrigerant Suction Pressure Adjustments Factory settings 30 to 34 psi under no load may change during shipment or occasionally during normal operation conditions. To adjust the suction pressure, proceed as followed: 4 Maintenance and Care NOTE: Refrigerant air dryers require relatively little maintenance if they are used accordance with the installation and operating instructions. Cleaning Fin Surface NOTE: These are air cooled refrigeration systems and depend upon cooling air drawn from the area around the dryer for efficient operation. 1. Inspect the fin surface of the condenser regularly and keep it free of dust, lint or paper. NOTE: A vacuum cleaner or low pressure air hose can be used for regular and normal maintenance of the fin surface. 2. Machine shop applications with oil vapor in the room air may require cleaning with fin surface cleaners available from refrigerant supply houses. Cleaning Timer Drain and Filter Element All models (see Figure 5) have a timer operated drain attached to the bottom of separator bowl. 1. Accumulation of compressor oil in the bowl of the separator as well as the sintered bronze element is possible. Both should be cleaned periodically. 2. Remove foam insulator from separator head. 3. Use a strap or chain wrench to remove the water separator bowl. 4. Drop bowl and remove completely. 5. Clean sintered bronze element with kerosene. 6. Reassemble in reverse order. 7. Close strainer ball valve and remove strainer screen from ball valve assembly located below separator. Clean with compressed air or pressurized water. 8. Test drain by depressing the Test button on the timer. If valve fails to open, or does not seal when closed, close the isolation valve (located near the strainer) and clean or replace the valve. Figure 5

TROUBLESHOOTING CHART Symptom Possible Causes(s) Corrective Action Unit will not run. 1. No Power. 1. Check power supply, fuses, circuit breaker. 2. Internal compressor overload. 2. Feel the temperature of the compressor and allow to cool off if hot. Observe the fan motor. Have the motor checked if it does not run. Clean the condenser. Dew Point Indicator Red Area High 1. Internal compressor overload. 1. Check for air overload. Check inlet air temperature. Check operation of fan motor. 2. High ambient temperature. 2. Check room temperature and hold between 45 F and 100 F. Indicator Light Off No power to the dryer Check power supply, fuses, circuit breaker. Dew Point Indicator Red Area Low 1. Low refrigerant charge. 1. Have qualified refrigeration service technician check out dryer or call factory. 2. Low ambient temperature. 2. Relocate dryer to heated area between 45 F and 100 F 3. Low hot gas valve setting. 3. Re-adjust hot gas valve to the green area on the dew point indicator gauge. (See minor pressure adjustment) High pressure drop 1. High air flow. 1. Air flow above rated flow of dryer. 2. Drain valve not discharging. 2. Manually blow down drain until water flow stops. Clean drain. 3. Freezing moisture in evaporator. 3. Re-adjust hot gas valve to the green area on the dew point indicator gauge. (See minor pressure adjustment) 4. Plugged separator element or drain. 4. Clean or replace. Water downstream of dryer 1. Compressed air is flowing through 1. Dryer must be operating 5-10 dryer before it is turned on. minutes before compressed air load. 2. Dirty drain trap. 2. Disassemble and clean at regular intervals. 3. Overload dryer above air flow *3. Reduce air load to dryer specifications. capacity. 4. High suction pressure. 4. Inlet air temperature too hot. 5. Low outlet air pressure. *5. Freezing of water, adjust suction pressure. (See minor pressure adjustments) 6. Low refrigerant charge. 6. Contact service technician to leak check. NOTE: Check or repairs of the refrigeration system must be done by a qualified refrigeration service technician with the required gauges and other equipment. 5

If Trouble Starts If the dryer cycles off and on for any reason TURN OFF THE DRYER. Call the factory for instructions, Check or repairs of the refrigeration systems must be made by a qualified refrigeration service technician. Before calling the factory for instructions, have the following data to report. Model No. Serial No. Refrigeration Suction Pressure. REPLACEMENT PARTS Model F-3528 F-3529 F-3530 F-3531 F-3532 Voltage 115/1/60 115/1/60 115/1/60 230/1/60 230/1/60 Compressor Make Tecumseh R- 134A Copeland R-134A Copeland R- 134A Copeland R- 134A Copeland R- 134A Separator/ Drain Assembly PART NUMBER PART NUMBER PART NUMBER PART NUMBER PART NUMBER Separator FK329-S1 FK329-S1 FK329-S1 FK329-S1 FK329-S2 Separator Bowl 3110-S1-8 3110-S1-8 3110-S1-8 3110-S1-8 3110-S1-9 Repair Kit RFK329 RFK329 RFK329 RFK329 RFK329 Element Kit EKF329 EKF329 EKF329 EKF329 EKF329 Float Drain (Pre 2007) FD06B FD06B FD06B FD06B FD06B Timer Drain Assy. A-27901 A-27901 A-27901 A-27901 A-27901 Refrigeration System *Condensing Unit 94820 14582 14589 14624 14627 *Compressor 94917 14769 14777 14779 14782 Expansion Valve 14571 14571 14546 14515 14515 Hot Gas Bypass Valve 91221 91221 91233 91233 91233 Refrigerant Filter 91235 14576 14570 14517 14517 Electrical Fan Motor 97935 95933 95934 94935 94935 Fan Blade 97943 95941 94941 98945 98946 Fan Switch --------- 91639 91639 91639 91639 Power On Light/Switch 57300 87846 97846 97846 97846 Power Cord 90390 91698 91699 --------- --------- Gauges *Dew Point Indicator 14765 14765 14765 14765 14765 Inlet Air Temperature --------- --------- --------- 103306 103306 Cabinet Panels Base Panel 14656 14640 14640 14666 14666 Cover Panel 14654 14642 14642 14663 14663 Back Panel --------- 14641 14641 14695 14695 End Panel Right Side 14655 14649 14649 14664 14664 Vented End Panel Left Side Vented 14680 14643 14643 14665 14665 6

ORDER REPLACEMENT PARTS BY CALLING (877) 640-8300 Please provide following information: Model Number Serial Number (if any) Part Description and Number Address parts correspondence to: ARROW DRYERS 745 Clark Ave. Bristol, CT 06010 WARRANTY POLICY When used under the conditions recommended by the manufacturer, Arrow Dryers, this model is warranted to be free from defects in material and workmanship for a period of twenty-four (24) months from date of receipt, not to exceed thirty (30) months from the factory ship date, provided Arrow is furnished the customer s name, address, and date of shipment information These units will utilize either a braze plate or modular type heat exchanger which will be warranted for five (5) years. This warranty is limited to the replacement of the heat exchangers, F.O.B. Factory, and subject to the same restrictions as outlined below concerning misuse, abuse or accident. The automatic drain carries a 90-day warranty. This warranty will apply to equipment installed, operated and maintained in accordance with the procedures and recommendations as outlined in the owner s manual published by Arrow Dryers. During the life of this warranty, Arrow Dryers will repair or replace (at Arrow Dryers option) any defective part or assembly, free of charge, F.O.B. its plant if such defect occurred in normal service and was not due to apparent misuse, abuse or accident. Any warranty service performed in the field must be authorized by Arrow Dryers, Unauthorized service voids the warranty and any resulting charge will not be paid by Arrow Dryers. Arrow Dryers makes no other warranties or guarantees, expressed or implied. The merchantability of the components is expressly excluded. The manufacturer assumes no liability for indirect or consequential damages. 7