Exterior Façade Lighting Design

Similar documents
Lobby Lighting Design

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Café DUSON- Overview

1.0 Introduction to Lighting Depth. 1.1 Hotel Tower Facace and Porte Cochere

Duke Tower Main Entrance Lobby Overview

Overview. The Reading Room

Lobby Lighting Redesign

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

Technical Report One

Lighting Depth Study. Exterior Departure/Canopy Area

Lighting Existing Conditions and Design Criteria Report

Lord Stirling Community School

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Cosmetology Lab Redesign

Lighting Depth Part 1: Exterior Space

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

Lindsey Beane. Executive Summary

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

The Bahen Centre for Information Technology. Meeting Room Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

Lighting Existing Conditions and Design Criteria Report

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

Schematic Design Proposal Presentation

LIGHTING NORTH FAÇADE AND PLAZA

Inspiration. Wall Street. Innovative Dynamic. Original. Established. Powerful Enlightened. Competitive. Modern. Intrigue

Eric Anderson. Technical Report 1. Existing Lighting Conditions

The Children s storytelling area

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

1.1.0 Exterior Facade

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Duke University Medical School. Duke School of Nursing

Technical Report #1 Existing Lighting Conditions and Design Criteria

Technical Assignment I

Lighting Design Criteria: Codes and Standards

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

2.0 Lighting Depth Introduction

L ig h t in g Dept h 8

Dorrance H. Hamilton Building

HARRY RANSOM HUMANITIES RESEARCH CENTER

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

University of California Santa Barbara. Student Resource Building

Advanced Lighting For Office

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Main Lobby Area (North Vestibule thru South Vestibule):

Technical Report 1 Part 2

Depth Work Part 1: Lighting Design

Shepherd University Wellness Center AE 481 Thesis Lighting Technical Report 1

Advances in Non-Residential Lighting Technologies

Thesis Proposal Update #2

Lighting Existing Conditions and Design Criteria Report

Table of Contents. Heather Lion Redifer Commons University Park, PA. General Lamp and Ballast Information 1-2

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

TECHNICAL ASSIGNMENT #3: SCHEMATIC LIGHTING DESIGN

Executive Summary. CNBC Global Headquarters Christine Cajilig

Lighting depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC. Introduction

Schematic Design Ideas for the Westlake Recreation Center. Presented by: Summer Padgett At Lutron Electronics On December 9, 2003

3. Desk lamps are generally 12 to 20 high and are used to light a specific work area.

How to light a small storage space rabdesign.ca 1

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

South Nassau Communities Hospital North Addition

Gathering Space. Function and Orientation. Space Characteristics Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Technical Assignment 1 Existing Lighting Conditions and Design Criteria

Marie Ostrowski Lighting/Electrical Dr. Mistrick Science Building Phase 1 Buffalo State College Buffalo, NY Monday, October 5, 2009 Technical Report

Woolly Mammoth Theatre. Washington DC

Lighting Depth CAL IT 2. Brian Smith. Introduction

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Steve Neimeister 8 October 2003 AE 481W AstroPower Headquarters Newark, Delaware Lighting/Electrical Option Consultant: M. Moeck

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

Abbey Beresik. Executive Summary. Ronald Reagan Presidential Library Simi Valley, California

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

TABLE OF CONTENTS 3 5.PART 1: EXISTING SPACE AND LIGHTING CONDITIONS 6 8.PART 2: LIGHTING DESIGN CRITERIA

BUG stands for Backlight, Uplight and Glare. The acronym

COMMERCIAL LIGHTING DESIGN GUIDE

Shepherd University Wellness Center AE 481 Revised Thesis Proposal

Franklin Square Hospital Center

SECTION LIGHTING REGULATIONS

Global Tech LED 8901 Quality Rd Bonita Springs, FL, Fuel Station Lighting Solutions

Senior Thesis Presentation

New LED Product Offerings

CHAPTER 32 EXTERIOR LIGHTING

HOSPITALITY LIGHTING DESIGN GUIDE

Monterey Downtown Lighting Strategy

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

D E S I G N G U I D E

USG LIBRETTO GMS CEILING ILLUMINATION OPPORTUNITIES

Multipurpose Room. Existing Conditions General Overview. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC

Lighting. Showroom Lighting Requirements. Introduction. Technology. Fixture and Performance

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Landscape and Streetscape Design 2.5

The AstroPower Headquarters Newark, Delaware

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Existing Area Description: The area is an angle around the North point of the building. It is a wide patio wrapping the façade of the building.

Lighting Design Thought Process

Uniformity Avg. : Min. Maintained Use/Task

Shepherd University Wellness Center AE 481 Thesis Proposal

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

The New York University Concourse Project. New York City. Existing Conditions and Design Criteria

Related Sections: TBD. Effective Date: January 1, 2016

Transcription:

Exterior Façade Lighting Design Duques Hall is located on George Washington campus in downtown Washington DC. It is located amidst some other university buildings, however, the façade is very visible from both directions down the street. Being a newer building on campus, Duques Hall is meant to stand out from it s surroundings. The façade has many unique architectural features that help it stand out among its surroundings. Two classrooms on the first floor are clad in glass so that the contents of the room are visible from the outside. Also, there is a set back above the main entrance of the building, that adds a unique look to the building. The most defining characteristic of the building, however, is the tower in the south east corner. Study rooms were placed on the second through the sixth floor of this tower and all exterior facing walls are covered in glass. This allows for these study rooms to be lit up at night and create a pillar of light shinning onto the surrounding area. Being in the city, there is not a lot of separation between the building and it s surrounding areas. There are several planters and benches placed in front of the entrance of the building before the walkway steps down onto the main sidewalk. There is also a small plaza on the corner of the square between Duques hall and the existing business school. The plaza is just a simple paved area on the corner between the buildings. The building is clad in a tan concrete, with steel and glass at each of the windows. The plaza and area around the sidewalk is set in a darker stone, and the sidewalk around the building is brick. Picture EXT.1 Picture EXT.1

Design Considerations The primary concern for the design of the exterior façade was to create a design that is memorable and dynamic. Creating an image that is not only impressive but memorable adds a note of credibility to the building that would not be there if a few wall washers were thrown on the exterior façade to provide a modicum of light. Another consideration was to utilize the light that would be placed on street level over the surrounding area. It is not only important to provide light for people that will be traveling to, from, and past the building at night, but it is also important to not provide an over abundance of light. Light trespass, particularly into surrounding buildings is a nuisance and not acceptable. To light the space, one of the ideas that were considered was how the switching of the interior lights would affect the overall aura of the building. A study was performed with a setting of just exterior lights and compared to a setting that involved lights on the interior of the façade switched on and dimmed when possible. Design Criteria All design criteria is based upon the standards set forth in the IESNA Lighting Handbook, and the following criteria was taken from it. The building has many very unique architectural features as were discussed above in the narrative. Highlighting these features was the biggest concern in lighting the façade, and it was on these areas that the design was focused around. Utilizing the light tower on the corner of the building was particularly important. Utilizing the interior lights along with the exterior lights was also a thought that was taken into account. Leaving the interior lights off leaves the interior dark and creates a dark and uninviting space. Using the interior fixtures to help brighten the building will help to create a more welcoming aura around the building. Avoiding as much light trespass and pollution while providing adequate light levels is a very important consideration. Careful selection of luminaries, and proper placement on the façade of the building should help to eliminate these two unwanted characteristics. Placing enough light for safety concerns is more important than the amount of trespass, but does not negate the importance of limiting as much trespass as possible. Although the intent could possibly be misplaced, my biggest design goal was to create a unique and impressive lighting layout. Making a system that would truly stand out and create a lasting memory was a big consideration.

Design Standards Horizontal Illumination Building Entrance 5-10 fc Prominent Structure 5-10 fc Walkways 6-10 fc Vertical Illumination Building Entrance 3-5 fc Prominent Structure 3-5 f Walkways 11-22 fc Power Density requirements Building Entries 30w/linear foot door entrance Building Façade.5w/ft 2 or 5.0W/linear foot (Ashrae Standard 90.1 standards) System Designs The light tower on the corner of the building was the first part of the façade that was looked at. This space is meant to be lit at full output through the entire of the night so that a portion of the building will always be glowing. To create this glowing affect, it was important to choose surfaces that would reflect light outward. A pendant fixture was designed to throw light up onto the ceiling, while that was supplemented with downlights to provide the necessary footcandle values on the ground. Perimeter lights were placed around the sides of the room to create glowing walls that would compliment the glowing ceiling. The entrance is probably the second most important part of the building. An entrance has to welcome a person into the space, and an entrance also has to be easy to determine from the rest of the façade. These ideas were kept in mind while trying to create an entrance that would stand out from the rest of the building. Interior light supplementing the exterior design also plays into the scheme of the design. First it is determined how the interior lights will affect the exterior façade, and then it will be determined how to best take advantage of this light. Fixture Schedule Fixture cut sheets can be found in ( appendix L ), while the lamp and ballast data that was used with each of the fixtures can be found directly after it.

Label A13 A14 B8 W1 W2 X1 X2 X3 X4 Y1 Z1 Z2 Z3 LED1 Description Interior Pendant fixture with uplight and louvered down light, used in all classrooms 2x2 interior recessed downlight, louvered shielding with silver frame Poulsin interior 3 tiered pendant, circular, 2' mounting height Exterior pole fixture, cylinder with diffusing section going 360 degrees Exteroir wall mounted fixture with lensed apperature, used to wash ceiling Exterior Wall mounted fixture, diamond shaped with cylinder diffusing section Trianglular wall mounted fixture, decorative sconce Exterior wall wash, recessed, aluminum housing Exterior recessed fixture, circular with 6 inch fixture size Parascoop fixture, wall mounted with uplight distribution Exterior wall mounted fixture, wide spread down and narrow beam up Recessed wall fixture, lensed with shielded top to prevent uplight In ground wall washing fixture, narrow distribution of up light Strip LED fixture, set up for continue run by attaching portions of LEDS Lamps Manufacturer Voltage Wattage Ballast (3) T8 - T8B Axis 277 96 W Dimming (2) T8 - U Prudential 277 64 W Electronic (2) TT - TT-c Louis Polsen 277 90W Electronic (4) T8 - T8-B Se'lux 277 114W Electronic (1) t5 ho Insight Lighting 277 49w Electronic (1) TT - TT-B Teka 277 35W Electronic (1) TT- TT-B Bega 277 35W Electronic (1) TT - TT-C Eliptipar 277 35W Electronic (1) TT - TT-D Erco 277 18W Electronic (1) TH - TH-1 Erco 277 300W - (1) MH - MH-3 Erco 277 70W - (1) MH - MH-2 Erco 277 35W - (1) MH - MH-2 erco 277 35W - LED Color Kinetic 24VDC 28.8W/4' -

Lamp Data Label Type CRI CCT W Initial Mean Lumen Lumen Manufactuer T8-B T8 80 3500 32 2950 2800 Philips TT-B TT 80 3500 35 2400 - Philips TT-C TT 80 3500 45 3200 - Philips TT-D TT 80 3500 18 1200 1130 Philips T5ho-A T5Ho 80 3500 49 4900 4606 GE MH-2 MH 83 3000 35 3300 2600 Philips MH-3 MH 830 3000 70 6600 4950 Philips TH-1 TH - - 300 5000 - Philips Ballast Data Label W Lamp Dimming BF Manuf BL-1b 54 t5ho no 1 Advanced BL-3 32 T8 yes 1* Lutron Btt-2 35 TT yes 1* Lutron Btt-3 45 TT yes 1* Lutron Btt-4 18 TT no 1 Advanced * Exact ballast data was not given so one was used. Light Loss Factor Numerous assumptions were made to help calculate the light loss factors for the exterior of the building. RSDD values were assumed using a RC value of 2.5 for each of the spaces, because the height and area of the rooms varied in each instance. The RSDD value for the exterior was simply assumed to be.8 as this is a low value for RSDD and the outside of a building that will not necessarily be clean. LLD for the façade was assumed to be under medium dirt conditions. BF was placed at one for each of the luminaries. The ballasts were picked as close to one, already, and with so much variability in the assumptions for the other factor, I wanted this to remain constant.

Label Maintenance Category LLD RSDD LDD BF LLF A13 II 0.8 0.95 0.95 1 0.722 A14 IV 0.8 0.95 0.9 1 0.722 B8 V 0.8 0.95 0.88 1 0.722 W1 V 0.8 0.8 0.82 1 0.512 W2 VI 0.8 0.8 0.8 1 0.512 X1 V 0.8 0.8 0.82 1 0.512 X2 V 0.8 0.8 0.82 1 0.512 X3 V 0.9 0.8 0.82 1 0.576 Y1 VI 0.9 0.8 0.8-0.576 Y2 III 0.9 0.8 0.85-0.612 Z1 III 0.9 0.8 0.85-0.612 Z2 IV 0.9 0.8 0.81-0.5832 Z3 IV 0.9 0.8 0.81-0.5832 Power Density Tower Study Rooms Label Wattage Quantity Power Density A8 32 5 160 B7 35 4 140 B8 90 4 360 Total = 660 w/ft2 = 1.51 be made up in other portions of the building. The interior of the tower may not be on the façade of the building, but it plays an important part in the lighting design for the space. The wattage per square foot value is slightly high for this space, but this can be negated by eliminating the lighting on the exterior portion of the façade, and if this is not substantial then savings can also Entrance Area Label Wattage Quantity Power Density W2 49 4 196 X3 35 2 70 X4 18 4 72 Z2 35 4 140 Total = 478 The power densities for this portion of the space is dependant on how long the horizontal run of the doors is. In this case, the run is 14 long which allows for a power density of 420 watts across the length of the entrance. The value obtained for the wattage in the entrance slightly exceeds the standards set by the ASHRAE codes. However, the wattage that I factored into this situation includes lights in a vestibule located directly behind the entrance. This extra space should allow for extra factor to be taken into consideration.

Building Façade Label Wattage Quantity Power Density Entry 478-478 Z1 70 12 840 X2 35 2 70 Y1 300 2 600 LED1 28.4 21 596.4 Total = 2584.4 According to ASHRAE standards, with 5W/ linear foot allowed on the façade, my building has a length of 165 which allows for 825W on the façade. Going by the.2w/ft 2 on the façade, my building is allowed to have 2706 W/ft 2 because of it s 13530 ft 2 of façade area. My façade design fulfills the second requirement. Panel Layout The following figures contain the luminaire layout for the auditorium. Each luminaire is labeled in the similar manner: X1 PXX X X The first number represents the fixture s representation in the luminaire plan. The second number is the panel on which the circuit can be found, the third number is the branch circuit on the panel, and finally, the final number is in correspondence to the dimming zone of the room when dimming is applicable. Figure EXT.1

Figure EXT.2

Figure EXT.3 Figure EXT.4

Figure EXT.5

Calculation Data Despite being placed in the city, there are few buildings around Duques hall that will actually be affected by any type of light trespass. As you can see in the pseudo color renderings below, the values on the road from reflected light never exceed 5 fc. Rendering EXT.1 Rendering EXT.2

Relamping One of the challenges for the lighting of the façade is ensuring that the lamps placed on the façade are accessible so that they can be relamped when they finally burn out. In this case, the luminaries were placed near the windows of the building. There is not direct access, and this is not a small distance for a person to reach across, but it is a possibility. The second, more logical option is to relamp the windows when the exterior part of the windows are washed. With a building that provides daylight into the interior, it would not be uncommon to have the windows cleaned at least once a year. The lamp life of the exterior fixtures should be long enough that they can be replaced when window washing occurs. Light Tower Rendering EXT.3 Design considerations for this part of the building begin to contradict themselves as the purpose of the light tower is to create a glowing portion of the building, while you want to eliminate throwing too much light onto the surrounding areas. The biggest area that is affected by the light tower is a portion of Funger Hall, the old business school building that is placed right next to Duques Hall. The façade that is washed by the light tower lacks window, and receives little affect from the light tower. The solution of lighting the ceilings and the walls within the space did an excellent job of providing the desired light output. Glowing walls translated into a glowing tower, and the result became a dynamic façade for people to view, while creating a glow that seriously affect the surrounding areas.

Building Entrance The main design consideration for the building entrance was to create a design that would stand out amongst the rest of the building while also becoming a space that would appear welcoming. Washing the ceiling above the doors, and the floor below helped to create a feeling of height to the space, while lighting the vestibules behind the doorway would help to create would add to this affect and help to make the Rendering EXT.4 space appear larger and brighter. The two fixtures in front of the door act as beacons, drawing your attention toward the space. Architectural Highlights The indentation above the entrance, along with the balcony area above it, is one of the more interesting aspects of the façade. By selecting a fixture with the varying spread on either side of it, a unique affect could be utilized to highlight this area. The long run of light on either side of the indentation helps to frame the area while the upligthts on the inside create glowing walls that separate it from the rest of the façade. Rendering EXT.5

Rendering EXT.6 Rendering EXT.7