DK-11 Countertop Water System. Owner's Manual

Similar documents
AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

OWNE R S MA N UA L. Made in USA. September 2015

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

AWR-520SB 52 Bottle Built-In Compressor Wine Cooler

Wine Cabinet Manual. We know you don t want to read through this manual, but trust us, there is good information in here.

AWR-520SB 52 Bottle Built-In Compressor Wine Cooler

ULTRASONIC HUMIDIFIER

AW-321ED. 32 Bottle Freestanding Dual-Zone Thermoelectric Wine Cooler OWNERS MANUAL. Read and save these instructions.

AWR-1600DB 160 Bottle Built-In Compressor Wine Cooler

JURAGON Pro USER MANUAL

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

Thermoelectric Cigar Cooler

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

Thermal Electric Wine & Beverage Chiller. Model: WC-20TL (20 Standard Bottle Capacity) Instruction Manual

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL

Owner's Manual RSL-2700 GRAPHIC LAMINATION PRODUCTS

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

177 Can Beverage Cooler

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

AWC-270E 27 Bottle Freestanding Compressor Wine Cooler

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Compact Refrigerator. User Manual Model 3590A

Upright Freezer. Model: UF-311W/ UF-311S USER S MANUAL

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

MINI DEHUMIDIFIER. SD-350TI With UV Light SD-350 INSTRUCTION MANUAL

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Installation & Operating Instructions

AB Can Beverage Cooler

240 ASSEMBLY & OPERATION MANUAL

29 Bottle Compressor Wine Cooler

Outdoor Beverage Center

Owner s Manual Window Air Conditioner

STAINLESS STEEL ELECTRIC KETTLE

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Installation & Operating Instructions

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

B.I.C.A Built-In Coffee Appliance

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Ozone + UV Sanitation

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

Installation & Operating Guide

Instruction Leaflet. Read instructions before operating. Retain for future reference.

AB Can Beverage Cooler

Countertop Clear Ice Maker

Read All Instructions Thoroughly Before Installing or Using the Disposer.

WHYNTER PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

Operator s Manual. Commercial Dryer/Air Mover. Standard Models PD350, PD500, PD750. A Tacony Company

16 OUTDOOR MISTING FAN

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

PERSONAL Ultrasonic Cool Mist Humidifier

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

AWR-290DB-B 29 Bottle Black Stainless Steel Compressor Wine Cooler

Parts Identification and Accessories Safety Information Installation Control Panel Layout Fully Automatic Washing...

96 Can Beverage Cooler

Instruction Leaflet Read instructions before operating. Retain for future reference.

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

BEFORE FIRST USE: TABLE OF CONTENTS

ADORABLE Ultrasonic Cool Mist Humidifier

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

INSTALLATION FLOOR REGISTERS WALL REGISTERS

Instruction Manual. Compact Portable Ice Maker. Wards.com Enjoy cold, refreshing ice in just 13 minutes

2.9kW Portable Air Conditioner

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

ROTARY CONTROL AIR CONDITIONER

Instruction Manual. Bucket Oil Pump

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Rechargeable UV-A LED/Emergency Light

Countertop Clear Ice Maker

QUICK START GUIDE. Modular 3000 Series. 115 V / 60 Hz

Model Instruction Manual. Coleman Limited One-Year Warranty. 26 Quart Power Cooler. For use with 12 VDC only

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

2.9kW Portable Air Conditioner

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

AC-12200E Portable Air Conditioner

LIMITED LIFETIME WARRANTY

O w n e r s M a n u a l

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Owner s. 18 Misting MF18W. To view

Transcription:

DK-11 Countertop Water System Owner's Manual

Atmospheric Water Systems, Inc. 189 Cross Street, Suite 110 San Luis Obiospo, CA 93401 phone: 805-858-9280 fax: 805-549-9790 email: cs@aws-h2o.com www.aws-h2o.com

Table of Contents Safety Precautions General Specifications Contents General Overview Hybrid Connection Installation & Operation Location of installation Installation precautions Operational procedures Maintenance Operation precautions Storage Cleaning (top tank) Cleaning (bottom tank) Cleaning (exterior case) Filter Replacement Water Filter U.V Light Air Filter Water Production Chart Operational indicator Menu / Set button Troubleshooting Warranty 3 4 4 5 5 6 7 8 9 10 13 14 15

Safety Precautions Dewpointe DK-11 Safety Instructions 1. Check country electric power supply 230V or 115V. 2. Ensure to plug into appropriate grounded socket. 3. Use socket connected to circuit breaker only. 4. DO NOT share socket with other appliances. 5. DO NOT touch power plug with wet hands. 6. DO NOT place heavy object on power cord. 7. Avoid exposure to extreme temperature or rain. 8. Place unit on hard, flat surface. 9. Place unit in an well-ventilated area. 10. Place unit at least 6 inches (15 cm) away from wall for proper air flow. 11. DO NOT place unit near flammable materials. 12. DO NOT place objects on top of unit. 13. If transporting, unit keep up-right. 14. Drain water prior to moving & installing unit. 15. DO NOT modify or disassemble unit, this may void warranty. 16. If leak occurs, unplug unit, drain water, call Service Center. 17. In case of electric leak, unplug, call Service Center. 18. Using incorrect filter may cause operational failure. 19. For all operational problems, call Service Center. 20. For Service Center contact, refer to back of manual.

Specification Dimension Weight Unit After Packing Unit After Packing 380 (W) x 520 (D) x 560(H)mm 455(W) x 580 (D) x 640 (H)mm 39.5 Kg 42 Kg Input Power 230V 50Hz 115V 60Hz Power Power Consumption Electrical Current 440 W 550 W 2.35 A Cold Water 7 ~ 12 45~54 F Cold Water Mild Cold 15 ~ 20 59~68 F Normal Temperature 20 ~ 25 68~77 F Storage Capacity 13.5 liters Contents D!-"" Owners manual Drain hose

General Overview Front Ventilation fan Air outlet Top cap Menu Button Set Button Power Button FND Display Water valve Rear Leg Hybrid Connection Top cover Air filter bracket Air filter Easy screws (Simpiy unscrew for air filter exchange) Rear panel Hybrid connection plug Drain connection Hybrid power connector Power cord Connect to tap water only through a Hybrid Kit (Optional) DK-11r id kit Hybrid kit To the tap 1 : Hybrid power connection 2 : Hybrid Connection plug 3 : Hybrid power connection (Kit) 4 : Tap water out (Kit) 5 : Tap water in (Kit)

Installation & Operation Location of installation (Indoor use only) 1. Avoid direct sunlight, exposure to rain and extreme heat or cold. (water parts may freeze or rupture) 2. Place the unit on hard, flat surface to prevent noise, leakage or shaking. 3. Place unit in an well-ventilated place. 4. For proper air flow and operation, place unit at least 6 inches away from wall. 5. To keep unit sanitary, avoid harmful gas or excessive heat. Installation Precautions 1. Check country power supply: 230V or 115V. 2. Ensure unit is plugged into the right socket. 3. Use grounded socket ONLY. 4. Use socket with circuit breaker. 5. DO NOT share plug with other appliances. 6. DO NOT touch power socket with wet hands. 7. DO NOT place heavy object on power cord. Operational Procedures 1. If unit has been tilted or laid down on side, do not start-up for at least 30 minutes. 2. Connect plug to socket. 3. Push Power Button for 3 seconds to start-up. 4. Do a priming process. (See image 1-1, 1-2) 5. Use Menu/Set button for desired water temperature. (see page 13) 6. Wait until unit has generated enough water to drink. Note: Priming process for Quick Start and sanitary reason, open cap on top of unit and pour approx. 5 liters of drinkable water. (Image 1-1, 1-2)

Maintenance Operating Precautions 1. DO NOT place objects on-top of unit. 2. To prevent leakage DO NOT tilt unit on side. 3. Completely drain water when moving unit. 4. If leak occurs, unplug unit, drain water completely and call Service Center. 5. DO NOT modify or disassemble unit. 6. In case of electric leak, unplug, call Service Centre. 7. Incorrect filter may cause poor operation. Storage 1. If storing the unit for a long period of time, drain water completely. 2. Thoroughly clean unit. 3. Cover to prevent unit from dust and store in the original box if possible. Cleaning (Top tank) 1. Unplug power cord. 2. Drain water completely. 3. Pull unit until the access to the bottom is available. 4. Use Phillips screwdriver to loosen 2 screws at the bottom side of front cover. (Image 2-1) 5. Remove the front cover. 6. Use Phillips screwdriver to loosen 2 screws on the rear side of top cover. (Image2-2) 7. Remove rubber plugs and loosen 2 screws. (Image2-2) 8. Remove top cover. 9. Use Phillips screwdriver to loosen 2 screws at the bottom side of top tank. (Image 2-3) 10. Clean inside with clean dishcloth/soft cloth. 11. DO NOT use detergent or chemical cleanser.

Cleaning (Bottom tank) 1. Use Phillips screwdriver to loosen 2 screws and remove rear panel. (Image 3-1) 2. Touch water level sensor with finger. (5 seconds) (Image 3-2) 3. Wait 2 minutes before unplugging power cord. 4. Disconnect fitting and wire from booster pump and water level sensor respectively. (Image 3-3) 5. Slide out bottom tank. (Image 3-4) 6. Clean with clean soft dishcloth. 7. DO NOT use detergent or chemical cleanser. Cleaning (Exterior case) Use clean dishcloth or soft cloth and mild detergent and water solution if necessary. Filter replacement Water filter 1. Power off and unplug the unit. 2. Remove rear cover/ Loosen 2 screws with Phillips screwdriver. (Image 3-1) 3. Carefully remove filter from filter clip. (There may be water in hose, fitting and filter) (Image 4-1) 4. Pull and remove filter while pushing the adaptor of the fitting in opposite direction. (Image 4-2) 5. Install new filter. (Place new filter in the same way) 6. After filter exchange, reset the filter replacement function by using Menu/Set button. (see page 13)

UV light 1. Power Off and unplug unit. Separate rear cover. (loosen & remove 2 screws with Phillips screwdriver) 2. Remove filters. (See water filter replacement) 3. Disconnect the housing of the U.V from ballast. 4. Remove U.V from U.V clip carefully. (There may be water in hose, fitting and U.V) 5. Pull to remove U.V while pushing the adaptor of the fitting in opposite direction. 6. Install a new U.V. 7. After U.V exchange, reset the U.V replacement function by using Menu/Set button. (see page 13) Note: DO NOT look directly at a shining UV light Air filter 1. Separate air filter bracket by loosening 2 easy screws with hand or Phillips screwdriver. (Image 5-1) 2. Remove air filter and replace with new air filter. (Image 5-2) 3. After air filter exchange, reset the air filter replacement function by using Menu/Set button. (see page 13) Water Generating Capacity Temp Ḥumid. 15 Daily Water Production in Lab (liters/day) 50% 60% 70% 80% 90% 3.2 4.1 5.9 6.4 8.3 20 5.2 5.8 7.2 8.2 11.3 25 6.6 8.3 11.7 13.9 17.0 30 8.4 11.5 16.1 18.2 23.0

Indicator Lights 1. Temperature indicator 2. Humidity indicator 3. Water Generation indicator 4. Water level indicator 5. Refresh (filtering) indicator 6. U.V indicator 7. Cold water temperature indicator 8. Air filter replacement indicator 9. Water filters replacement indicator 10. U.F replacement indicator 11. Hybrid connection indicator 12. Leakage indicator Temperature indicator - Two digits show the current room temperature - If temperature is not optimum to generate water, Lo signal will appear Humidity indicator - Two digits show the current room humidity - If humidity is not optimum to generate water, Lo signal will appear Notes: In low temperature and humidity conditions, the unit will stop generating water to save energy. Both temperature and humidity indicators will show as Lo signal.

Self-Error detection function In case of error during operation, 2 digits on the temperature/humidity indicator show ERROR signals respectively. Turn off and unplug unit. Wait a few seconds and Plug In and Turn On again. If the ERROR signal continues to light up, turn unit off and call the Service Center - Cold temp. sensing failure (Er / S1) - Room temp. sensing failure (Er / S2) - Fan motor failure (Er / Fn) - Control board failure (Er / Cn) - Pump failure (Er / BP) Generating water indicator - Dropping motion becomes active : Unit is now generating water - Icon is in hold motion : Unit is in pause cycle - No icon showing : Water generating function is disabled. See Menu/Set button function Water level indicator - Shows level of water in top tank. - If water level sensor is incorrect, text will start blinking and bars light up intermittently Refresh indicator - Icons rotating clockwise : Unit is in re-circulation cycle. U.V indicator - Replacement of U.V indicated by red text light. install new U.V and reset the U.V indication function by the Menu/Set button (see page 13). Yellow light text will appear - If both the U.V icon and U.V text blink : Check if U.V. light or ballast has a problem Notes : Proper UV function is essential to keeping the water clean and pure. If both the icon and text are blinking continuously, call the Service Center immediately.

Cold water temperature indicator - Shows water temperature selected by Menu/Set button. - Coldest : 7 ~ 12 Celsius degrees 45 ~ 54 Fahrenheit - Colder : 15 ~ 20 Celsius degrees 59 ~ 68 Fahrenheit - Normal : 20 ~ 25 Celsius degrees. 68 ~ 77 Fahrenheit - Yellow text light turns green when cooling system is active Air filter replacement indicator - Air filter needs replacing when the green light turns red. - Replace with new air filter and reset the air filter replacement indicator function by Menu/Set button (See page 13). Light will return to Green. Water filters replacement indicator - Water Filter needs replacing when the green light turns red. - Replace both 1 st and 2 nd filters with new ones and reset the water filters replacement indicator function by Menu/Set button (See page 13). Light will return to Green. U. F replacement indicator - U.F replacement : Green light becomes Red. - Replace U.F filter with new one and reset the U.F replacement indicator function by Menu/ Set button (See page 13 ). Light will return to Green Hybrid connection indicator - Icon and text shows when hybrid water connection is active - Customer s selection by Menu/Set button(see page 13) Note: Connect to tap water only using the optional Hybrid Kit. A direct connection to tap water will cause serious leakage problems. Leakage indicator Note: If icon and text is showing, the unit has a leak. Turn off and unplug the unit and drain water completely. Call Customer Service Center immediately.

Set / Reset Button Set/ Reset function 1. Push the menu button for 3 seconds 2. Set/Reset function is selected with blinking text as indicated by pushing the menu button for seconds in sequence, as follows; 1) AWS : Water Generating function - SET 2) U.V : U.V light self-detector function - RESET 3) Cold water temperature - Coldest ( 7~12 ) -SET 4) Cold water temperature - Colder ( 15~20 ) - SET 5) Cold water temperature - Normal ( 20~25 ) - SET 6) Air filter replacement function - RESET 7) Water filters replacement function - RESET 8) U.F replacement function - RESET 9) Hybrid connection function - SET 3. When function is selected (text blinking), push set button for 3 seconds to set/ reset the working mode. 4. To clear the Set/Reset stage, push the menu button again 3 seconds or leave it for more than 5 minutes. Then Set/Reset function will return to previous stage. Example 1. To reset Air filter replacement after exchanging air filter. 1) Push menu button for 3 seconds. 2) Push menu button 5 times to go to Air filter indicator. 3) Push the Set button for more than 3 seconds. Note: U.V/ Air filter/ Water filters/ U.V filter replacement function must be individually reset. DO NOT reset any function without resetting the indicator signal. 2. Setting normal cold water temperature 1) Push menu button for 3 seconds 2) Push menu button 4 times to go to Normal water temperature indicator. 3) Push the Set button for more than 3 seconds.

Trouble shooting Water generating system-related problems. 1. Is unit connected to proper voltage socket? 2. Is humidity and temperature adequate to generate water? (Check if temperature and humidity shows Lo signal) 3. Has air filter been changed? Is RED indicator showing? (Check if air filter exchange indicator shows red) 4. Is it time to change the water filters? Check indicator light. 5. Are the humidity digits showing Error? (Turn off/ Unplug unit. Then plug-in & Turn back on. If digits still show Error signal, call Service Center) 6. Is the unit installed in well-ventilated area? 7. Has a large amount of water just been consumed? Wait for unit to regenerate more water. Noise-related problems. 1. Move the unit to hard /flat surface 2. Has any object come in contact with the unit? Cold water temperature-related problems. 1. Is the cold water temperature set to normal / colder? (Set temperature to Coldest. Wait at 20 minutes, If water does not get cold call Service Center) 2. Has there been a large amount of water consumed? (When approx. 1 liter of water has been taken out, the cold water becomes lukewarm. Wait for 5~10 minutes for cold) Leakage-related problems. 1. If a leak occurs, turn off and unplug the unit. 2. Disconnect the unit from hybrid connection, if any. 3. If water valve is leaking, press it down several times. If it does not work, replace the valve. 4. Do the humidity digits show Er/ Bp signal? (Turn off/ Unplug unit. Turn unit back on. If leak continues, turn off/ unplug the unit and call for Service)

Warranty Dewpointe products and accessories are warranted against natural defects in material or faulty workmanship. One (1) year parts warranty, 90 days labor on defective product. Defective parts will be replaced free of charge. Defective parts must be returned to AWS and will be exchanged for new or rebuilt replacement parts. Warranty does not cover cosmetic damage or damage due to acts of god, accident, misuse, abuse, negligence, or modification of, or to any part of the unit. Warranty does not cover damage due to improper operation or maintenance, connection to improper voltage supply, or attempted repair by anyone other than a facility authorized to service the unit. Warranty does not cover the unit sold As-Is or With-All-Faults, or consumables such as replacement filters. Warranty will be determined with proof of purchase, unit lot number and date of issue. Purchase receipt must accompany returning defective unit or parts. A return authorization from AWS must be issued prior to returning Dewpointe products or parts for repair or warranty. Product name Atmospheric Water Maker Model number Serial number Purchase date Customer Address Dewpointe DK-11 Address Name Phone Name Phone (YYYY-MM-DD) Note: Failure to follow proper maintenance & cleaning procedures of the unit, as per the owner s manual may deem the warranty void