Innovative Solution of Domestic Heating. Split type. Split DHW Integrated type. Monobloc type

Similar documents
PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

AIR TO WATER. Complete Solution meets various needs

AIR TO WATER. Complete Solution meets various needs

PRODUCT LINEUP AIR TO WATER For RESIDENTIAL

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

DESIGN & TECHNICAL MANUAL

Hot water supply. Indoor unit. Domestic hot water tank. Take thermal energy from atmosphere. Outdoor unit

FUTURE SOLUTION OF DOMESTIC HEATING. Air to Water

Air to water Heat Pump System

Do you want a versatile solution

DESIGN & TECHNICAL MANUAL

Air to water Heat Pump System

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

DESIGN & TECHNICAL MANUAL

NATURAL HEATING MACHINE

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Tower Green HE Hybrid

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

DESIGN & TECHNICAL MANUAL

The iqe Boiler Range. Combination and System T Boilers.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Technical description. Atec.

HT V2 HT Split

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning

AQUAHEAT ADVANCE SPLIT

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

2. HYDRAULIC UNIT. COMFORT SERIES_Single phase type: WG A050DG WG A100DG HIGH POWER SERIES: WG G140DG WGYK160DG9

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Advance Split

WHY A MHI HEAT PUMP?

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Natural geothermal energy

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Daikin Altherma Low Temperature monobloc heat pump

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

PAC BT LOW TEMPERATURE HEAT PUMP

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

THE HEAT PUMP CHOICE OF PROFESSIONALS

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Samsung Eco Heating System

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Air-cooled modular Chiller. Nick Technical Engineer

HIGH-POWER HEAT PUMPS. Up to 300 kw

Product Line Introduction. Karl Zhang Technical support engineer

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

Daikin Altherma Low Temperature monobloc heat pump

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

White paper: New Ecodesign rules and energy labelling for space and water heaters

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

AIR SOURCE HEAT PUMPS DUAL CLIMA

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Efficient heating that won t cost the earth

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

VRV The total solution. Integrated Climate Control

PROMATIC WDC Heating controllers Energy under control

Aqua 1 plus Air-water heat pumps for domestic hot water production

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

ROTEX HPDU monobloc Maximum efficiency in water heating

FREQUENTLY ASKED QUESTIONS

BWL air heat pumps BWS brine heat pumps

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

FAMILY PRO SIMPLY THE BEST

Control Products & Systems OEM

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Solar controllers Energy under control

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

Ground Source Heat Pumps

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

PRODUCT RANGE HEAT PUMPS 2012

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

KEMPER ThermoSystem. For further information on KTS use the QR code!

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Transcription:

Innovative Solution of Domestic Heating Split type Split DHW Integrated type Monobloc type

Fujitsu General Waterstage heat pumps are very efficient, regenerative and varied central heating systems, which absorb the energy mainly from the air. 21 Models INDEX What s a Heat Pump? 2 to 4 h Ambient air 1 h Electricity 3 to h of heat Comfort heating Absorbing the free energy from atmosphere. Heat pump system requires only 1 of electricity to generate 3 to thermal energy. Heat Pump system framework Heat Heat Heat Expansion valve Heat absorption Compressor Indoor Heat Heat Heat Heat Emitter Heat Heat Primary Energy Usage Reduced Drastically! Proportion of primary energy into heating energy of 100% Primary Energy Consumption* Direct electrical heating 27% Fuel boiler Gas condensing boiler 7% 109% Energy heating 100% 79% *Electricity loss is different due to power plant. Example efficiency of power plant: 36% 04 OVERVIEW 0 USAGE INTRODUCTION 16 PRODUCT TECHNOLOGY & FEATURES 22 PRODUCT LINEUP SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE 34 SYSTEM CONFIGURATION & OPTIONAL PARTS OTHERS SIMPLE INSTALLATION & MAINTENANCE INSTALLATION INFORMATION SPECIFICATIONS & DIMENSIONS MODEL SELECTION SOFTWARE 2 3

OVERVIEW Advantage Advantage Wide Comfort Energy Efficiency standard Less CO2 Emissions Low Running Cost This environmentally-friendly system substantially reduces CO2 emissions compared to conventional gas and hydro carbons combustion. Direct electric heating Average annual CO2 emissions Running cost is low and economical by high efficiency heat pump technology. Direct electric heating Average annual running cost Fuel boiler Gas condensing boiler Fuel boiler Gas condensing boiler 0 0 100% *Calculations based on data provided by European Program-2001` for EU 27 Fuel boiler efficiency: 9%, Gas boiler efficiency: 93% *The values may vary depending on installation, location, and operating conditions. Clean and Healthy Easy Installation and Maintenance Since burners are unnecessary, NOx and other harmful substances are not generated. All components are built into compact outdoor or hydraulic indoor. Environmentally friendly heating system No chimney sweep No pollution Low maintenance cost Well structured. Sophisticated arrangement of hydraulic s, allows easy piping and maintenance 4

OVERVIEW Energy Efficiency standard Product labels For Space heaters For Combination heaters Product identifier Trade mark Symbol for space heating Scale of efficiency class, from + (highest efficiency) to G (lowest efficiency) Sound power level outdoors and (where relevant) indoors Year when label issued Efficiency class in low temperature operation Symbol for hot water heating Efficiency class in medium temperature operation Scale of efficiency class, from A (highest efficiency) to G (lowest efficiency) for hot water heating Temperature map of Europe with three climate zones and the rated heat output of each Optional symbol where operation is possible only in off-peak periods Number of EU regulation The Ecodesign Directive Lot1 Regulation 13/2013 New Ecodesign directive defines a regulatory framework for improving the environmental performance of energy-related products(erp)through design. From 26 September 201, the Ecodesign Directive will apply to space heaters(including heat pumps and fossil fuel boilers), combination heaters(for both space and water heating),water heaters and water storage tanks. All these products will have to meet minimum requirements for energy efficiency* and maximum sound power levels.the minimum energy efficiency level will be raised from 26 September 2017 and maximum sound power level will be lowered on 26 September 201. Wide Comfort The clean energy delivers comfort to all spaces in the home up to the living room, bedrooms, bath and swiing pool. Solar connection DHW tank Hydraulic Room Heating Energy efficiency class Except low temp HP C low temp HP C ηs 10 ηs 17 12 ηs < 10 10 ηs < 17 9 ηs < 12 123 ηs < 10 *Energy efficiency is represented by seasonal space heating efficiency(ηs). This value is based upon the seasonal coefficient of performance(scop). 90 ηs < 9 ηs < 123 2 ηs < 90 107 ηs < The Energy Labelling Directive (EU)No /213 7 ηs < 2 100 ηs < 107 36 ηs < 7 61 ηs < 100 34 ηs < 36 9 ηs < 61 30 ηs < 34 ηs < 9 ηs < 30 ηs < The energy label aims to help consumers make direct comparisons of energy use, as well as product specific features. On all labels, product identifier, efficiency class, sound power levels and heat output must be displayed. For heat generators, the scale runs from + to G(++ to D from 2019). There are two different product labels for space heaters and combination heaters. Domestic Hot Water Swiing Pool Cooling EHPA Quality label FUJITSU GENERAL`s WATERSTAGE* have obtained the EHPA Quality Label** by tests according to the international Standards EN and EN1702. The EHPA Quality Label** is a label that shows the endconsumer a quality heat pump on the market. *: High Power split model **: Check the validity of label at www.ehpa.org/ql 6 Seasonal space heating SG-Ready Label SG-Ready is a defined standard by BWP***, which makes it possible that the device can be integrated into a smart grid. Heat pumps, which are equipped with the SG-Ready Label, can receive signals from the power grid (and e.g. also from PV systems) about the available (unused renewable) energy (from wind, sun & water). Fujitsu General provides the SG-Ready compatibility to all new Heat Pumps series. ***BWP: the Federal German Heat Pump Association 7

USAGE INTRODUCTION Wide range lineup suited for regional characteristics, family structure, and application We provide various products to meet your needs from High Power via heating-centered series to reasonably-priced compact series temperature -2 C temperature -20 C Cold district Split type with separate outdoor and hydraulic indoor For details, see page 10-, 24-27 High Power series Comfort series Heat up Hydraulic indoor Heat up Hydraulic indoor DHW Tank 190 L DHW Tank 190 L Split type with DHW tank built-in hydraulic indoor For details, see page 12-13, 2-31 High Power series Comfort series Heat up Hydraulic indoor Heat up Hydraulic indoor DHW Tank 190 L DHW Tank 190 L All-in-one type without refrigerant piping work For details, see page -1, 32-33 Compact series Heat up Hydraulic indoor 9

USAGE INTRODUCTION All-in-one indoor 24-27 page s For cold regions High Power series Room heating & Domestic hot water 24-2 page Compact design Comfort series 26-27 page DHW Tank (Option) and hydraulic indoor can be installed freely, so installation is easy. Since hydraulic indoor is installed inside a house, freezing of circulated water can be prevented. A larger heating capacity can be performed flexibly by using more s in cascade connection. + Boiler + DHW Tank By combining existing boiler, powerful heating can be performed even at low outdoor temperature. DHW tank (option) can be used to supply hot water by connecting it to the system. 300 Liter 10

USAGE INTRODUCTION All-in-one indoor 2-31 page s For cold regions High Power series 2-29 page Compact design Comfort series Room heating & Domestic hot water 30-31 page Space is saved drastically due to built-in DHW tank. Existing boiler can be replaced easily. A larger heating capacity can be performed flexibly by using more s in cascade connection. Stylish space saving solution with built-in DHW tank 12 DHW tank 190 L 13

USAGE INTRODUCTION Smart installation 32-33 page s All in one model 32-33 page DHW Tank (Option) Simple setting Room heating & Domestic hot water and hydraulic indoor can be installed anywhere due to compact size. Installation work can be performed easily only by connecting hydraulic pipes. DHW tank can be connected to indoor side. Compact Design Weight 49 kg By combining existing boiler, powerful heating can be performed even at low outdoor temperature. 67 model + DHW Tank 300 2 + Boiler DHW tank (option) can be used to supply hot water by connecting it to the system. 300 Liter 1

PRODUCT TECHNOLOGY & FEATURES 16 17

PRODUCT TECHNOLOGY Twin Rotary Compressor High Durability Co-axial Heat Exchanger Stainless steel buffer tank Warm refrigerant flow Linear Control Injection Port Corrosion protected No flow switch necessary Anti-freeze-protection is unnecessary Heated water Optimum Co-axial Heat Exchanger Product technology for Unit Twin Rotary Compressor Accurate temperature control by DC inverter technology with Linear Control Injection Port Optimized circuit = higher water temperature Co-axial Heat Exchanger V-PAM inverter technology Linear Control Injection Energy saving pump with constant volume or pressure a djustment function. Class A Esay Control Hydraulic Indoor Unit Controler 4 Heating mode Hydraulic Linear Control Injection Evaporator Normal refrigerant circuit High Efficiency Class A Pump Heating cycle Automatic mode High Temperature It realizes the high condensing temperature without overheating discharge gas temperature by Linear Control Injection process during compression. Therefore, the condensing temperature rises up higher than normal circuit. A higher hot water temperature is realized by controlling the injection amount according to the usage state. Product technology for Hydraulic Indoor Unit Comfort/Reduce mode switching automatically according to time program Reduce mode Constant reduce temperature Constant Comfort mode Constant comfort temperature Time Protection mode Stand-by mode with anti-frost protection 1 19

FEATURES Energy Saving Comfort Control A program adjusts the hot water temperature automatically in advance based on the outdoor temperature, so hot water temperature can be controlled so that setting temperature is maintained constantly. Prograable timer Peak Cut Function* The setting of timer operation can easily be adjusted. Changing the heating mode linked with time is possible. This function performs operation by setting a peak current value and reducing the power consumption. Mode The ratio of suppressing the power consumption 1 2 3 4 100% 7% 0% Almost 0% Day-Weekly timer setting The day-weekly timer can be set up for up to 3 times per day. Allows separate settings for each day of the week. Holiday timer setting The holiday timer can be set up for up to periods If you are absent for a long time in the winter, freezing of room can be prevented. Safety Function Automatic heating curve operation Auto-changeover Automatic heating curve control based on outdoor temp and setting room temperature. If the cooling operation function is set, the system can automatically switch to cooling or heating, depending on the outdoor temperature to provide all-season comfortable air conditioning. Anti-legionella function Anti-freeze function 2 Zone Individual Control* The growth of Legionella in DHW tank is suppressed and safe and clean hot water is supplied at all times. Water circulation and compressor can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented. Radiator 60 Leaving water temperature ( C) Automatic temperature control with heating curve 0 Chosen heating curve zone Even if hot water temperature is different in 2 heating systems, they can be controlled simultaneously. 40 High Heater Over 0 C possible 30 Floor heating -20-1 -10-0 10 1 20 temperature ( C) Setting temperature ºC ~ 7ºC 30 ~ 360 min Radiator 2nd Circuit Kit temperature Low ON ~40 C Heating curve off-set: Adjust setting room temp. OFF Anti-freeze mode DHW Tank 300 L Floor heating Time This can be fine adjusted when too warm or too cold. Leaving water temperature ( C) High 2 Stage Low Noise Mode* +4. C Setting heating curve -4. C Low Low temperature ( C) can be switched to silent mode, depending on the installation environment. (Valid only for High Power) -2dB Rated noise value Low noise mode Stage 1-4dB System can continuously supply hot water by built in back up heater or boiler, as emergency, even if an error is occurred. Radiator Backup heater operation Maintaining the room temperature during defrost operation by boost start operation 20 Maintenance Boiler* Backup heater Backup heater can operates at low outdoor temperature so that comfortable status can be maintained. The backup heater is controlled intelligently just as a security backup for very cold days/ nights and only activated when really necessary. Operation status display Quick error handling service and maintenance are possible by this function. Error Stage 2 High Quick recovery from defrost operation Error/Maintenance alarm Emergency operation Error history saves 10 errors in memory Display telephone NO. of service company Massage Floor heating Hydraulic *When additional boiler connected *: Optional parts are required. 21

PRODUCT LINEUP for various needs Type High Power series Comfort series Usable outdoor temperature: High Power series Usable outdoor temperature: -2 C Comfort series Usable outdoor temperature: -20 C Usable outdoor temperature: -2 C Compact series Usable outdoor temperature: -20 C -20 C Capacity range: / System //16 /6/ 10 / //16 /6/ 10 /10 60 C hot water supply even at -20 C coutdoor temperature C hot water supply even at -10 C outdoor temperature 60 C hot water supply even at -20 C outdoor temperature C hot water supply even at -10 C outdoor temperature C hot water supply even at -20 C outdoor temperature Different heating system can be used. Like floor heating, radiators and others.* Different heating system can be used.like floor heating, radiators and others.* Different heating system can be used.like floor heating, radiators and others.* Different heating system can be used.like floor heating, radiators and others.* Heating and DHW in one system. Heating and DHW in one system.* Heating and DHW in one system.* Additional electric heater for backup provided. Additional electric heater for backup provided. Heating and DHW space saving in one hydraulic indoor. Heating and DHW space saving in one hydraulic indoor. Additional electric heater for backup provided. Additional electric heater for backup provided. Up to two independent control circuits.* Up to two independent control circuits.* Solar connection for hot water production.* Solar connection for hot water production.* Up to two independent control circuits.* Up to two independent control circuits.* Solar connection for hot water production.* Solar connection for hot water production.* Cascade connection up to three systems.* Cascade connection up to three systems.* Cooling operation is possible.* Cooling operation is possible.* Cascade connection up to three systems.* Cooling operation is possible.* Additional base heater can be connected to prevent from freezing.* Cooling operation is possible. Cascade connection up to three systems.* Cooling operation is possible.* Check the validity of label at www.ehpa.org/ql Power source 1Ø 230 V/0 Hz 3Ø 400 V/0 Hz 1Ø 230 V/0 Hz 1Ø 230 V/0 Hz 3Ø 400 V/0 Hz 1Ø 230 V/0 Hz 1Ø 230 V/0 Hz 6 Capacity range 10 16 *Optional parts are required. 22 23

PRODUCT LINEUP Single Phase power supply WSYG0DG6 Powerful Heating High Power models realize high leaving water temperature and high heating capacity even at low ambient temperature by newly developed Linear Control Injection Technology. It is possible to provide high water temperature and warm rooms in cold regions. WOYG2LCTA WOYG0LCTA High Power series High Power models realizes high heating capacity and high efficiency by newly developed Linear Control 3 Phase power supply 16 High Leaving Water Temperature No backup heater* High leaving water temperature 60 C kept down to -20 C outdoor temperature without using backup heater. * If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation. Leaving water temperature ( C) 60 30-20 High Power model -1-10 - 0 temperature ( C) Injection Technology and Co-axial Heat Exchanger. These properties are the key for a reliable heating operation throughout the whole year- even in a strong winter. WOYK2LCTA WOYK0LCTA WOYK160LCTA WSYK160DG9 * Extended Operation Range Down to -2 C Improved operation range down to -2 C outdoor temperature High COP 4.2 4.1 4.30 4.22 4.10 *:Check the validity of label at www.ehpa.org/ql Energy efficiency is improved by the linear Control Injection Technology and the optimization of refrigerant cycle control. High Power model realizes high performance and high efficiency by adopting twin sensors and control technology corresponding to hot water heating. Single Phase 3 Phase 16 A7W condition FEATURES Comfort Control Automatic heating curve operation Auto-changeover Cooling operation Quick recovery from defrost operation Backup heater operation Cascade connection s Pump Optimization of refrigerant cycle operation High Power model realizes high performance and high efficiency by adopting twin sensors and control technology corresponding to hot water heating. Temperature sensor Emitter system Energy Saving Prograable timer Safety Function Anti-legionella function Anti-freeze function Emergency operation Error/Maintenance alarm s Balancing vessel (Required optional part) Under floor heating Refrigerant Pressure sensor Hot water Co-axial Heat Exchanger 24 2

PRODUCT LINEUP 6 Heated up Comfortably WSYA00DG6 WSYA100DG6 Comfort models realize high efficient operation by compact design suited for European environment. Hot water temperature can be controlled finely by All DC control and comfortable space heating and domestic hot water are provided. WOYA060LFCA WOYA00LFCA Comfort series 10 High Leaving Water Temperature No backup heater* Maximum leaving water temperature is C without backup heater. Hot water supply temperature can be maintained even at 10 C outdoor temperature. Leaving water temperature ( C) 60 0 For Comfort series, optimized flow * If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation. 40 temperature control is realized by DC inverter technology. WSYA100DG6 Wide Operation Range Improved operation range down to -20 C outdoor temperature 30-10 - 0 10 1 20 temperature ( C) WOYA100LFTA High COP 4.2 4.27 4.0 4.02 6 10 A7W condition FEATURES Comfort Control Automatic heating curve operation Auto-changeover Cooling operation Quick recovery from defrost operation Backup heater operation Energy Saving Prograable timer Safety Function Anti-legionella function Anti-freeze function Emergency operation Error/Maintenance alarm Cascade connection (10 kw model) s s Pump Balancing vessel (Required optional part) Under floor heating technology 620-10 30 DC Fan Motor High performance, high efficiency small DC fan motor mounted. DC Twin Rotary Compressor High efficient DC twin rotary compressor DC Inverter Smooth water temperature control realized by DC inverter control. 26 27

PRODUCT LINEUP Single Phase power supply WGYG0DG6 High Performance High Power models realize high leaving water temperature and high heating capacity even at low ambient temperature by newly developed Linear Control Injection Technology. It is possible to provide high water temperature and warm rooms in cold regions. WOYG2LCTA WOYG0LCTA High Power series Split DHW integrated type realizes significant space saving because of the integrated DHW tank. Quick hot 3 Phase power supply 16 High Leaving Water Temperature No backup heater* High leaving water temperature 60 C kept down to -20 C outdoor temperature without using backup heater. * If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation. Leaving water temperature ( C) 60 30-20 High Power model -1-10 - 0 temperature ( C) water supply is possible due to built-in high performance DHW tank. Heating Extended Operation Range Down to -2 C and domestic hot water supply can be selected inside the intelligent controller. High Power models realize very efficient large heating capacities WGYK160DG9 Improved operation range down to -2 C outdoor temperature 4.2 4.1 4.30 4.22 4.10 by newly developed Linear Control Injection Technology and Co-axial heat Exchanger. WOYK2LCTA WOYK0LCTA WOYK160LCTA High COP Energy efficiency is improved by the linear Control Injection Technology and the optimization of refrigerant cycle control. High Power model realizes high performance and high efficiency by adopting twin sensors and control technology corresponding to hot water heating. Single Phase 3 Phase 16 A7W condition FEATURES Comfort Control Automatic heating curve operation Auto-changeover Cooling operation Quick recovery from defrost operation Backup heater operation Energy Saving Prograable timer Safety Function Anti-legionella function Anti-freeze function Emergency operation Error/Maintenance alarm Optimization of refrigerant cycle operation Co-axial Heat Exchanger Temperature sensor Refrigerant Pressure sensor DHW Tank Emitter system Pump Hot water Hot water Shower Supplied water High Power model realizes high performance and high efficiency by adopting twin sensors and control technology corresponding to hot water heating. For Split DHW Integrated type Hydraulic DHW Tank 190 L 64 1,40 69 Stylish space saving solution with Built in High Performance DHW Tank 190 L DHW Production with coil heat exchanger to optimise the DHW performance Quick temperature rise due to a big exchanger surface 2 29

PRODUCT LINEUP 6 Heated up Comfortably WGYA00DG6 WGYA100DG6 Comfort models realize high efficient operation by compact design suited for European environment. Hot water temperature can be controlled finely by All DC control and comfortable space heating and domestic hot water are provided. Comfort series WOYA060LFCA WOYA00LFCA High Leaving Water Temperature No backup heater* Maximum leaving water temperature is C without backup heater. Hot water supply temperature can be maintained even at 10 C outdoor temperature. Leaving water temperature ( C) 60 0 For Comfort series, optimized flow * If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation. 40 temperature control is realized by DC inverter technology. 10 Wide Operation Range 30-10 - 0 10 1 20 temperature ( C) Improved operation range down to -20 C outdoor temperature WGYA100DG6 High COP 4.2 4.27 4.0 4.02 WOYA100LFTA 6 10 A7W condition FEATURES Comfort Control Automatic heating curve operation Auto-changeover Cooling operation Quick recovery from defrost operation Backup heater operation Energy Saving Prograable timer Safety Function Anti-legionella function Anti-freeze function Emergency operation Error/Maintenance alarm technology 620-10 30 DC Fan Motor High performance, high efficiency small DC fan motor mounted. DC Twin Rotary Compressor High efficient DC twin rotary compressor DC Inverter Smooth water temperature control realized by DC inverter control. 30 31

PRODUCT LINEUP High Performance WSYP100DG6 High Leaving Water Temperature No backup heater* Smart installation Hydraulic Indoor Unit Compact series 10 WPYA00LG High leaving water temperature of C keeps to -20 C outdoor temperature without additional heater. * If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation. Leaving water temperature ( C) 60 0 40-20 Wide Operation Range -1-10 - 0 temperature ( C) Improved operation range down to -20 C outdoor temperature The compact Indoor provides two electrical back up heater, each with 3 capacity 12 L expansion vessel included No waste of space. DHW Kit installation inside the hydraulic indoor possible. New generation controller. Connection by Modbus protocol possible. Heat metering included Compact designed heat pump. Refrigerant pipe work is unnecessary. Only hydraulic connecting work is to be WSYP100DG6 High COP 4.0 ( model) High COP is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger. done. Circulation pump, safety valve and automatic vent valve are included. Easy installation and maintenance is feasible. WPYA00LG WPYA100LG technology DC Fan Motor DC Twin Rotary Compressor DC Inverter High performance, high efficiency small DC fan motor mounted. High efficient DC twin rotary compressor Smooth water temperature control realized by DC inverter control. FEATURES Comfort Control Automatic heating curve operation Auto-changeover Cooling operation Quick recovery from defrost operation Backup heater operation Energy Saving Prograable timer Safety Function Anti-legionella function Anti-freeze function Emergency operation Error/Maintenance alarm Easy installation & maintenance! All-in-One Model Ambient air Heating circuit pump Monobloc Evaporator Compressor Plate heat exchanger Hydraulic Heating emitter Hot water 67 Weight 49 kg model Compact Design Weight 72 kg model 2 High Efficient Plate Heat Exchanger Very compact size achieved by a thin high-efficiency heat exchanger 32 33

SYSTEM CONFIGURATION & OPTIONAL PARTS Control System Configuration Optional Parts 34

Control User`s needs are supported by offering a variety of controls, such as individual control and remote control options. Solar connection Individual Controller Adaptor for external device Wireless Remote Control (option) Wired Remote Control (option) Web server (option) Internet UTW-KW1XD UTW-KW4XD Room Thermostat UTW-CXA or Room Thermostat UTW-CXD Smartphone control RF Module UTW-MRCXD Modbus clip (option) UTW-KMBXE Remote Control UTW-C74TXF*1 UTW-C74HXF*1 Remote control system Home Automation system Remote Control UTW-C7XD *1: 19 Languages included,no separate Estern European RC necessary Hydraulic Indoor Unit Controller Simple operation mode setting Selecting the heating mode and Domestic hot water operation Large LCD display Operation status display Error display plain text Navigation and setting Selecting the heating menu Setting program timer 36 Service & Maintenance Tool LPB clip (option) UTW-KL1XD Web server (option) UTW-KW1XD UTW-KW4XD or Service Tool (option) HMI Kit (option) UTW-KHMXE Corresponding to multi languages UTW-KPSXD*2 Software UTW-KPSXD*3 *2: UTW-KW1XD or UTW-KW4XD is required for the connection. *3: UTW-KL1XD is required for the connection. 37

SYSTEM CONFIGURATION Split type System Configuration System Case Studies Basic Unit System Components (Optional Parts) Controller (Optional Parts) Heating & Hot Water (Locally purchased) Hot Water (Locally purchased) 2 emitter simultaneous heating (Individual control) Hydraulic Indoor Unit High Power series WSYG0DG6 WSYK160DG9 Solar (Locally purchased) Hot Water s Comfort series WSYA100DG6 Boiler (Locally purchased) Boiler Connection Kit UTW-KBDXD & Balancing Vessel UTW-TEVXA DHW Tank Shower Bath s Pump Valve Pump Radiator Cascade Kit UTW-KCMXE (for master) UTW-KCSXE (for slave) Unit High Power series WOYG2LCTA WOYG0LCTA 2nd Circuit Kit UTW-KZDXD* UTW-T20XA UTW-T30XA UTW-T30XD Heat Exchanger UTW-ESPXA & Swiing Pool Kit UTW-KSPXD* Wired Remote Control Radiator Fan Coil Floor Heating Swiing Pool Boiler connected to heating (Boiler + Heating) s s Valve Boiler Pump Valve Pump Radiator Room Thermostat UTW-CXA 2 emitter simultaneous heating & Domestic Hot Water (Cascade) WOYK2LCTA WOYK0LCTA WOYK160LCTA Remote Control UTW-C74TXF or Type A Hydraulic indoor s Tank Hot water supply (e.g. for shower) Wireless Remote Control RF Module UTW-MRCXD Valve Pump Comfort series WOYA060LFCA WOYA00LFCA Room Thermostat UTW-CXD s Balancing vessel (Option) Valve Pump Radiator WOYA100LFTA Web-Server UTW-KW1XD UTW-KW4XD Remote Control UTW-C7XD Type B s Tank Hot water supply (e.g. for shower) *Regulation Extension Kit (UTW-KREXD) is required. Valve Internet Gas Refrigerant Flow pipe Liquid Refrigerant Return pipe Pump Locally purchased Remote Controller Cable Domestic Hot Water Web server Cable s Balancing vessel (Option) Valve Pump Radiator 3 39

SYSTEM CONFIGURATION Split DHW Integrated type System Configuration System Case Studies Basic Unit Hydraulic Indoor Unit High Power series WGYG0DG6 WGYK160DG9 Boiler (Locally purchased) System Components (Optional Parts) Controller (Optional Parts) Heating & Hot Water (Locally purchased) Hot Water Hot Water (Locally purchased) Single heating & Domestic Hot Water Boiler Connection Kit UTW-KBDXD & Balancing Vessel UTW-TEVXA Shower Hot water supply (e.g. for shower) Comfort series WGYA00DG6 WGYA100DG6 2nd Circuit Kit UTW-KZDXD* Bath Radiator Radiator Heat Exchanger UTW-ESPXA & Swiing Pool Kit UTW-KSPXD* Fan Coil Swiing Pool Unit High Power series WOYG2LCTA WOYG0LCTA 2 emiter simultaneous heating (Individual control) & Domestic Hot Water Wired Remote Control Floor Heating Hot water supply (e.g. for shower) WOYK2LCTA WOYK0LCTA WOYK160LCTA Room Thermostat UTW-CXA Remote Control UTW-C74TXF Radiator Comfort series WOYA060LFCA WOYA00LFCA or Wireless Remote Control Floor heating RF Module UTW-MRCXD WOYA100LFTA Room Thermostat UTW-CXD Boiler connected to heating (Boiler + Heating) & Domestic Hot Water Web-Server UTW-KW1XD UTW-KW4XD Remote Control UTW-C7XD Hydraulic indoor Boiler Hot water supply (e.g. for shower) *Regulation Extension Kit (UTW-KREXD) is required. Internet Gas Refrigerant Flow pipe Liquid Refrigerant Return pipe Locally purchased Remote Controller Cable Domestic Hot Water Web server Cable Floor heating Radiator 40 41

SYSTEM CONFIGURATION Monobloc type System Configuration System Case Studies Basic Unit Hydraulic Indoor Unit Solar (Locally purchased) System Components (Optional Parts) Controller (Optional Parts) Heating & Hot Water (Locally purchased) Hot Water Hot Water (Locally purchased) Single heating system WSYP100DG6 Boiler (Locally purchased) DHW Tank Shower Bath UTW-T20XA UTW-T30XA UTW-T30XD Floor heating Monobloc Unit Radiator WPYA00LG Fan Coil WPYA00LG WPYA100LG Heat Exchanger UTW-ESPXA & Swiing Pool Kit UTW-KSPXD* Wired Remote Control or Floor Heating Boiler connected to heating (Boiler + Heating) Boiler Room Thermostat UTW-CXA Swiing Pool Remote Control UTW-C74TXF or Valve Wireless Remote Control Floor heating RF Module UTW-MRCXD Room Thermostat UTW-CXD Web-Server UTW-KW1XD UTW-KW4XD Remote Control UTW-C7XD 2 types of heat distribution Internet Locally purchased Note: 1. Only one heating circuit can be connected. 2. Only one Controller (Option) can be connected. Hot water Supply (e.g. for shower) Modbus Clip UTW-KMBXE Home Automation System Locally purchased Flow pipe Remote Controller Cable Domestic Hot Water Return pipe Web server Cable Tank Floor heating 42 43

OPTIONAL PARTS Optional parts compatibility for system Optional parts compatibility for control Split Split DHW integrated type Monobloc Split Split DHW integrated type Monobloc Product Name Model Name High Power Comfort High Power Comfort 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø Compact 1Ø Product Name Model Name High Power Comfort High Power Comfort 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø Compact 1Ø 16 6 10 16 6 10 10 16 6 10 16 6 10 10 2nd Circuit Kit UTW-KZSXE UTW-KZDXE HMI Kit UTW-KHMXE *3 UTW-C74TXF *3 Wired Boiler Connection kit UTW-KBSXD UTW-KBDXD Remote Controller UTW-C74HXF *3 UTW-C7XD Wireless Balancing vessel UTW-TEVXA UTW-C7XD-E *4 DHW kit UTW-KDWXG (Internal) UTW-KDWXD (External) *1 *1 *1 *1 *1 *1 *1 *1 *1 Room Thermostat Wired Wireless UTW-CXA UTW-CXD DHW tank 200 Liter 300 Liter UTW-T20XA UTW-T30XA *1 *1 *1 *1 *1 *1 *1 *1 *1 Sensor Transmitter UTW-MOSXD 300 Liter UTW-T30XD *1 *1 *1 *1 *1 *1 *1 *1 *1 RF Modules for BSB-Port UTW-MRCXD Circulating pump UTW-PHFXD Web server UTW-KW1XD UTW-KW4XD Swiing Pool kit UTW-KSPXD LPB Clip UTW-KL1XD Heat Exchanger for swiing pool kit UTW-ESPXA Modbus Clip UTW-KMBXE *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 Cooling kit UTW-KCLXD *2 *2 *2 UTW-HAMXE Regulation Extension Kit UTW-KREXD Base Heater UTW-HAMXF Low Noise Kit UTW-KLNXE Service Tool (incl.oci700 adaptor) UTW-KSTXD Drain Pan UTW-KDPXA Service Tool Software UTW-KPSXD Cascade Master Kit (incl. LPB Clip) Cascade Slave Kit (incl. LPB Clip) UTW-KCMXE UTW-KCSXE External connect kit UTY-XWZXZ2 *1: DHW operation is possible without DHW Kit and DHW Tank. *2: Cooling operation is possible without cooling kit *3: 19 Languages included,no separate Estern European RC necessary *4: Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia) *: UTW-KL1XD is required for the connection. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor *6: UTW-KW1XD or UTW-KW4XD is required for the connection. *7: Additional optional part necessary : Available : Not Available 44 4

OTHERS Simple Installation & Maintenance Installation Information Specifications & Dimensions Model Selection Software 47

SIMPLE INSTALLATION & MAINTENANCE Simplified installation Easy Installation & Maintenance Pre-setting configurations temperature simulation When installed, the controller makes it simple to set system settings without having to individually set the system s components and s. It can be checked whether each operates correctly under the set conditions and expected outdoor temperatures when the system is actually assembled. All hydraulic safety & controlling components built in, no additional selection required Easy pre-setting pattern systems (Duo heating : 12 patterns) Hot water shower Tank Indoor Radiator Valve Pump Refrigerant pump down operation Pump Valve Pump Pump Easy access for maintenance operations No installation of refrigerant circuit connections (Only Monobloc) Hydraulic Indoor Indoor Lifting bars for an installation without any difficulty or risk Radiator Under floor heating Under floor heating Valve Under floor heating Indoor temperatures in the range from 0 C to +0 C can be simulated. Indoor Valve Maintenance Support Tank Hot water shower Pump Diagnotics function for trouble shooting Floor drying Configurstion (Parameter 700) Type of installation Pre setting 1 1 heating circuit Pre setting 2 2 heating circuit Pre setting 3 1 heating circuit & boiler backup Pre setting 4 2 heating circuit & boiler backup Pre setting 1/2 heating circuit & buffer control Pre setting 6 1/2 heating circuit & buffer control & boiler backup Pre setting 7 cascade connection Master Pre setting cascade connection A Pre setting 9 cascade connection B/C When floor heating is installed, it can be used to dry the concrete surrounding the hot water piping more quickly to shorten the construction period. Set temperature max. 7 C Error display Operation status display Operation status display How to know which error has appeared When an error is occuring i Error symbol appears on the controller Set period ~2 Days Info button press Info button Detailed information will be displayed Error code Error designation Clear text info (UART) DHW & solar control auto detection pool heating & cooling optional Controller features a large LCD display and buttons to make setting functions easy Main operation flow and setting contents for installers and end users Large display Display of all segments operation mode indicate Clock Temperature DHW Massage Service/maintenance Timer menu 1 Flow Chart Example Item Install Setting Pump speed setting,configuration. Heating curve setting, Heat pump shout off error Installers Navigation Reset Cooling mode End users 4 POWER MODE DHW information switching When an error is occurring When an error is occurring green and red LED flash along with error cause Simple setting Operation mode error 2 Option Setting Cooling kit, DHW kit, Boiler kit, Swiing pool kit 3 Convenient Function Automatic Heating curve setting, Floor controlled driving, temperature adjiustment, Maintenance period srtting 4 workout Setting Confirmation Operation conform (Heating cooling, DHW, option,) 6 User Setting Date and time, time program, Operation temperatur setting temperature simulator LED2(GEEN) LED1(RED) Confirm flashing times ERROR : ON : Blinks rapidly Confirm blink code for error code indication Check the error code table 49

INSTALLATION INFORMATION 0 300 mini 0 mini 300 0 mini 1000 300 mini 1000 120 600 1000 120 600 Hydraulic is to be hang on the wall Weight < 60kg (including water) Distances for maintenance should be respected Floor stand Weight: 12 kg (without water) Distances for maintenance should be respected. Hydraulic is to be hang on the wall Weight < 60kg (including water) Distances for maintenance should be respected Floor stand Weight < 71 kg (without water) Distances for maintenance should be kept Electrical Wiring S Electrical Wiring Remote control (option) sensor or Remote control (option) sensor or Room thermostat (option) Room thermostat (option) or or Remote control (option) Remote control (option) or Interconnection between the outdoor and the hydraulic Phase, Neutral, Earth, Counication bus cable Hydraulic or Room thermostat (option) DHW power supply cable Hydraulic Power supply cable to the electrical back-ups cable Interconnection between the outdoor and the hydraulic Phase, Neutral, Earth, Counication bus cable Electric panel sensor DHW power supply cable Power supply cable to the electrical back-ups cable Electric panel Power supply cable SD Room thermostat (option) Power supply cable Remote control (option) or Room thermostat (option) or Remote control (option) or Room thermostat (option) Interconnection between the outdoor and the hydraulic Phase, Neutral, Earth, Counication bus cable DHW power supply cable Power supply cable to the electrical back-ups cable Electric panel Power supply cable 0 1

SPECIFICATIONS & DIMENSIONS Split type Specifications (High Power series) Model Name Specifications (Comfort series) WSYG0DG6 WSYG0DG6 WSYK160DG9 WSYK160DG9 WSYK160DG9 WOYG2LCTA WOYG0LCTA WOYK2LCTA WOYK0LCTA WOYK160LCTA Capacity range Heating capacity 7 C/ C floor heating * Input power 1 COP Heating capacity 2 C/ C floor heating *1 Input power COP Heating capacity -7 C/ C floor heating*1 Input power COP 16 10.0 13.0 10.0 13.0 1.17 2.4 3.23 2.1 3.20 3.70 4.2 4.1 4.30 4.22 4.10 10.77 12.00 10.77 13.00 13.0 3.44 3.7 3.40 4.1 4.34 Model Name WSYA00DG6 WSYA100DG6 WSYA100DG6 WSYA100DG6 WOYA060LFCA WOYA060LFCA WOYA00LFCA WOYA100LFTA Capacity range Heating capacity 7 C/ C floor heating * Input power 1 COP Heating capacity 2 C/ C floor heating *1 Input power 3.13 3.10 3.17 3.13 3. COP 10.3.4 10.3 12.20 13.0 Heating capacity 4.32.0 4.2.13.40 2.40 2.27 2.43 2.3 2.0-7 C/ C floor heating*1 Input power COP Space heating characteristics*2 6 10 4.0 6.00 7.0 10.00 0.996 1.41 1.4 2.49 4.2 4.27 4.0 4.02 4.0 4.9.6 7.70 1.39 1.3 1.7 2.47 3.24 3.24 3.17 3.12 4.10 4.60.70 7.40 1.47 1.74 2.23 2.97 2.79 2.64 2.6 2.49 Space heating characteristics*2 Temperature application C Energy efficiency class Temperature application + + + Energy efficiency class C + + + + Rated heat output(prated) 9 13 9 13 13 Rated heat output(prated) 4 4 6 7 Seasonal space heating energy efficiency(ηs) % 109 11 3 2 7 10 7 9 Seasonal space heating energy efficiency(ηs) % 169 169 16 3 1 h 642 6062 041 624 6669 930 703 673 9062 740 Annual energy consumption h 3026 2160 310 20 36 337 41 Annual energy consumption Sound power level db(a) 6 69 69 6 70 6 Sound power level 71 Hydraulic Specification db(a) 6 60 6 63 6 69 6 69 Hydraulic Specification Power source 1 Ø 230 V 0 Hz Dimensions H W D Weight (Net) Water circulation Min/Max Buffer tank capacity 3 N 400 V 0 Hz 00 40 47 kg 42 L/min 19./39.0 24.4/4.7 Expansion vessel capacity Power source 1 Ø 230 V 0 Hz Dimensions H W D Weight (Net) 19./39.0 L 24.4/4.7 27.4/4. 00 40 47 kg Water circulation 16 Buffer tank capacity Min/Max 42 L/min.1/16.2 10./21.7 13./27.1 L L Expansion vessel capacity L Max C 60 Leaving water temperature range Max C Water pipe connection diameter Flow/Return Water pipe connection diameter Flow/Return Ø 2.4/Ø 2.4 Capacity Capacity 6.0(3.0 2pcs.) Max A Backup heater Ø 2.4/Ø 2.4 6.0(3.0 2pcs.) 9.0(3.0 3pcs.) 1 Ø 230 V 0 Hz 3 N 400 V 0 Hz Backup heater specification 1.1/36.1 16 Leaving water temperature range specification Power source Current Max Dimensions H W D A 22.0 2.0. Weight (Net) 9. Power source 10. kg Dimensions H W D 92 99 Additional refrigerant charge amount Liquid Diameter Min/Max Length(Pre-charge) Height difference Operation range 2.0 0 /20 17. 30 900 330 41 42 60 1.40 1.0 R410A (2,0) Refrigerant amount kg Additional refrigerant charge amount 1.10 g/m Liquid Diameter Connection pipe 1. 620 790 290 kg Ø 1. m 12. Refrigerant (Global warming potential) Ø 9.2 Gas Length kg g/m.0 Weight (Net) R410A (2,0) Refrigerant amount 1 Ø 230 V 0 Hz Current 1,290 900 330 Refrigerant (Global warming potential) Connection pipe 441 Gas Length Min/Max m 1 Length(Pre-charge) Max m 1 Height difference Heating C -2 to Operation range 2 40 Ø 6. Ø 9.2 Ø 12.70 Ø 1. m /30 m 1 Max m 20 Heating C -20 to *1:The values of heating capacity/input power/cop are based on measurement of EN standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values. *2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html. Dimensions (High Power series) Dimensions (Comfort series) Unit Unit Hydraulic Indoor Unit Unit Unit Hydraulic Indoor Unit WOYG2LCTA/WOYG0LCTA WOYK2LCTA/WOYK0LCTA/WOYK160LCTA WSYG0DG6/WSYK160DG9 WOYA060LFCA/WOYA00LFCA WOYA100LFTA WSYA00DG6/WSYA100DG6 60 60 40 330 12 Drain port Ø20 40 Top view Heating flow Ø2.4 20 479 21 21 Front view 2 Front view 31 330 12 47 97 9 790 62 290 20 Front view 77 Heating return Ø2.4 30 Heating return Ø2.4 900 1 620 1290 1290 97 9 Top view Heating flow Ø2.4 Front view 1 479 21 47 12 00 31 32, 900 12 400 330 320 31 60 39 2 77 00 900 Top view 32, Top view 4.4 400 400 40 Front view Front view 3

SPECIFICATIONS & DIMENSIONS Split DHW Integrated type Specifications (High Power series) Model Name Specifications (Comfort series) WGYG0DG6 WGYG0DG6 WGYK160DG9 WGYK160DG9 WGYK160DG9 WOYG2LCTA WOYG0LCTA WOYK2LCTA WOYK0LCTA WOYK160LCTA 10.0 2.4 4.2 10.77 3.44 3.13 10.3 4.32 2.40 13.0 3.23 4.1 12.00 3.7 3.10.4.0 2.27 10.0 2.1 4.30 10.77 3.40 3.17 10.3 4.2 2.43 13.0 3.20 4.22 13.00 4.1 3.13 12.20.13 2.3 16 1.17 3.70 4.10 13.0 4.34 3. 13.0.40 2.0 Capacity range Heating capacity Input power COP Heating capacity Input power COP Heating capacity Input power COP 7 C/ C floor heating * 1 2 C/ C floor heating *1-7 C/ C floor heating*1 Space heating characteristics*2 Temperature application Energy efficiency class Rated heat output(prated) Seasonal space heating energy efficiency(ηs) Annual energy consumption Domestic hot water characteristics*2 Load profile Energy efficiency class Energy efficiency(ηwh) Annual electricity consumption Specification Power source Dimensions H W D Weight (Net) Water circulation DHW capacity Hot water heater capacity Expansion vessel capacity Leaving water temperature range Water pipe connection diameter Hot water pipe connection diameter Backup heater specification Power source Current Dimensions H W D Weight (Net) Refrigerant (Global warming potential) Refrigerant amount Additional refrigerant charge amount Capacity + + 13 13 Space heating characteristics*2 Temperature application Energy efficiency class Rated heat output(prated) % 109 11 3 2 7 10 7 9 Seasonal space heating energy efficiency(ηs) h 642 6062 041 624 6669 930 703 673 9062 740 Annual energy consumption 6 70 6 69 69 kg L/min L L C 19./39.0 24.4/2.7 6.0(3.0 2pcs.) A kg 22.0 Diameter Length Length(Pre-charge) Height difference Operation range 2.0. 1,290 900 330 27.4/4. 3 N 400 V 0 Hz 9. 92 10. 99 R410A (2,0) 2.0 0 Ø 9.2 Ø 1. /20 1 1-2 to m m m C WGYA100DG6 WGYA100DG6 WOYA060LFCA WOYA00LFCA WOYA100LFTA 4.0 0.996 4.2 4.0 1.39 3.24 4.10 1.47 2.79 6 6.00 1.41 4.27 4.9 1.3 3.24 4.60 1.74 2.64 7.0 1.4 4.0.6 1.7 3.17.70 2.23 2.6 10 10.00 2.49 4.02 7.70 2.47 3.12 7.40 2.97 2.49 4 + 4 + 6 Min/Max Max Flow/Return Capacity + 7 + % 169 169 16 3 1 h 3026 2160 310 20 36 337 41 441 60 6 63 6 69 6 db (A) 6 69 L 120 0 % h 1 Ø 230 V 0 Hz 1,40 64 69 12 kg L/min L L C.1/16.2 10./21.7 13./27.1 190 1. 12 1.1/36.1 190 1. 12 Ø 2.4/Ø 2.4 Ø 19.0 6.0(3.0 2pcs.) 1 Ø 230 V 0 Hz Max A kg.0 12. 620 790 290 17. 41 1. 30 900 330 60 42 R410A (2,0) kg g/m Diameter Connection pipe Domestic hot water characteristics*2 Load profile Energy efficiency class Energy efficiency(ηwh) Annual electricity consumption Specification Power source Dimensions H W D Weight (Net) Water circulation DHW capacity Hot water heater capacity Expansion vessel capacity Leaving water temperature range Water pipe connection diameter Hot water pipe connection diameter Backup heater specification Power source Current Dimensions H W D Weight (Net) Refrigerant (Global warming potential) Refrigerant amount Additional refrigerant charge amount 9.0(3.0 3pcs.) Max Heating 24.4/4.7 WGYA100DG6 WOYA060LFCA C Annual energy consumption 71 3 N 400 V 0 Hz 1,40 64 69 12 19./39.0 190 1. 12 60 Ø 2.4/Ø 2.4 Ø 19.0 kg g/m Liquid Gas Min/Max 6 L A 66 1 Ø 230 V 0 Hz Max -7 C/ C floor heating*1 9 1 Ø 230 V 0 Hz Max Flow/Return 2 C/ C floor heating *1 13 % h Min/Max 7 C/ C floor heating * WGYA00DG6 Heating capacity Input power COP Heating capacity Input power COP Heating capacity Input power COP 1 + db (A) Capacity range 9 C Annual energy consumption Connection pipe Model Name Length Length(Pre-charge) Height difference Operation range Liquid Gas Min/Max Max Heating 1.10 1.40 1.0 40 Ø 9.2 2 Ø 6. Ø 12.70 Ø 1. m m m C /30 1 20-20 to *1:The values of heating capacity/input power/cop are based on measurement of EN standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values. *2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html. Dimensions (High Power series) Dimensions (Comfort series) Unit Unit Hydraulic Indoor Unit Unit Unit Hydraulic Indoor Unit WOYG2LCTA/WOYG0LCTA WOYK2LCTA/WOYK0LCTA/WOYK160LCTA WGYG0DG6/WGYK160DG9 WOYA060LFCA/WOYA00LFCA WOYA100LFTA WGYG0DG6/WGYK160DG9 31 330 900 12 31 330 Drain port Ø20 12 0 10 40 Top view 790 12 Top view 900 62 69 Front view Front view 330 12 21 620 4 31 290 20 21 21 Front view 77 30 20 1290 1290 400 77 43 60 39 2 900 Top view 320 Top view 64 43 4.4 400 400 64 644 630 99 76 10 644 630 99 76 0 60 60 103 69 Front view Front view Front view 103

SPECIFICATIONS & DIMENSIONS Monobloc type Specifications Model Name WSYP100DG6 WPYA00LG WPYA00LG 10.00.00 10.00 1.19 1.7 2.30 4.20 4.0 4. 3.6 4. 4.90 1.07 1.23 1.44 3.40 3. 3.40 3. 7.10.00 1.3 2.93 3.32 2.7 2.42 2.41 Capacity range Heating capacity 7 C/ C floor heating *1 Input power COP Heating capacity 2 C/ C floor heating * Input power 1 COP Heating capacity -7 C/ C floor heating*1 Input power COP WPYA100LG Space heating characteristics*2 Temperature application C Energy efficiency class + + + Rated heat output(prated) 4 4 6 7 7 Seasonal space heating energy efficiency(ηs) % 171 123 16 167 h 30 192 32 0 4491 db (A) 62 61 Annual energy consumption Sound power level 6 3700 6 Hydraulic Specification Power source 1 Ø 230 V 0 Hz Dimensions H W D 03 40 47 Weight (Net) kg 40 Buffer tank capacity L 22 Expansion vessel capacity Water pipe connection diameter Backup heater L 12 Flow/Return Ø 2.4/Ø 2.4 Capacity 6.0(3.0 2pcs.) specification Power source 1 Ø 230 V 0 Hz Dimensions H W D 67 2 300 kg 49 Max A 10.9 Min/Max L/min.0/20.0 Flow/Return Ø 19.0/Ø 19.0 Weight (Net) Current Water circulation Water pipe connection diameter 2 0 330 72 1.2 17. 10.0/30.0 Ø 2.4/Ø 2.4 Refrigerant R410A (2,0) Refrigerant amount kg Leaving water temperature range Operation range 1.0 1.72 Max C Heating C -20 to *1:The values of heating capacity/input power/cop are based on measurement of EN standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values. *2:All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html. Dimensions Unit Unit Hydraulic indoor Unit WPYA00LG WPYA00LG/WPYA100LG WSYP100DG6 40 26 7 70 0 1 0 40 4 03 1 Top view Top view 2 330 327 7 3 7 43 6 327 300 1 30 40 73 16 0 300 97 9 6 Front view 2 40 4 173 37. 441. 67 Front view 47 479 Front view 7

MODEL SELECTION SOFTWARE Fujitsu General s new software for the WATERSTAGE automatically provides a combination of WATERSTAGE equipments just by giving few parameters. The software is featured with multiple languages, and automatic update function. Model selection with detailed technical information The software automatically selects the equipments just by inputting some factors, like the region where the equipment is installed, required capacity to heat up the space, and a heating method. The transition in the equipment capacity at each outdoor temperature condition and/or when back up heater is under operation can be easily created by this software. The entire system configuration can be reviewed and modified once the s are selected. And by seeing the images and the list of equipments at the same time, it avoids mistake in the selection of equipments. The visible images of the optional items enables the correct configuration of the systems. All of the associated optional items are automatically chosen in a case the application requires several devices of the WATERSTAGE equipments. The software automatically provides graphs of monthly running cost, CO2 emission volume, cost comparison against other heating sources, and other data to allow the users to see at a glance the financial benefit of choosing WATERSTAGE equipments. Estimate function The software automatically provides the cost estimate of the entire WATERSTAGE system, not only the equipment itself but also the optional items. Creating project files for customers Various kinds of documents such as an equipment list, a system diagram, a cost estimate table, and an equipment CAD data can be printed out to paper or output into the files. This function also comes with a feature which allows you to change the template design of the documents. Software updates The database can be automatically updated through FTP by automatic update function. 9