Recessed LED Wall/Slot SAE 202

Similar documents
2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Grüv Flare Regressed. Recessed Linear LED

RECESSED - WITH StepLens OPTION

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Grüv Flare Regressed. Recessed Linear LED

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

RECESSED T-Bar & Drywall

Fino Healthcare. Asymmetric Wall Mount Indirect LED

M60 LED Recessed Wet Location

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

FULL BLEED APPLICATION SHOT RENDERING

Etch 2' x 2' Recessed LED

Linea 1.5. Linear Direct Wall Wash LED

Fino. Asymmetric Wall Mount Indirect LED

Hornet HP. Round Glass Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

Ivalo Lumaris LED Linear Lighting

Ivalo Lumaris LED Linear Lighting

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Performance Chart Electrical Data

LUX PENDANT DIRECT/INDIRECT

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

OUTPUT RANGE: VIVID SERIES

Hornet HP. Square Glass Downlight

RECESSED Spec Guide. up to 111 lm/w performance

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Evoke Square Downlight

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Evoke 2.9" HP. 2.9" Square Downlight

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

LIGHT CHANNEL TRIM 1.6

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

BAS SFP22 Edge-lit LED Panel

Evoke Square Downlight

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

Ivalo Lumaris LED Linear Lighting

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Evoke 2.9" HP. 2.9" Square Downlight

Hornet HP. Semi-Recessed 4-Light Square Multiple

SURFACE Spec Guide. up to 105 lm/w performance

Essenza. Round Downlights

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

SYSTEM. field cuttable. lipleds 8200 Series

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

3.75 Gyro Shift Multiples Single Head

VESICA LINEAR SUSPENDED VES L

M100 My White LED Direct Tunable White

Running Magnet 2.0 Suspension Up&Down High-tech LED lighting system for interior architecture

LIGHT CHANNEL 45 COMPLETE FIXTURE

l i g h t A B S O R B H

Essenza. Square Downlights

Velato. Recessed Slot Adjustable Multiples

FPLHB - Fidelux Premier Linear Highbay

lumenalpha downlight Specification Sheet

Classix 6" 6" Round Lens Wall Wash

M100 LED Direct/Indirect

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

Catalog # Project. Comments. Prepared by

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Performance Chart Electrical Data

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Claude Indirect Wall WALL

Evoke Round Downlight

Max 4 Flush Lens RECESSED

Performance Chart Electrical Data

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Running Magnet 2.0 Suspension Down High-tech LED lighting system for interior architecture

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

Performance Chart Electrical Data

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

SDL4 LED Strip Diffused Lens

Hornet HP. Recessed 4-Light Square Multiple

BAS SDL8' LED Strip Diffused Lens

M36 My White LED Direct

LED Lighting Product Guide. Winter A portfolio of industry-leading solutions that are changing the way we look at light.

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

ArcLine Recessed LED luminaire

BeveLED Cylinder LBRP6 Surface

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Evoke Square Adjustable HP

ADVANCED HIGH CEILING Tetriss Series

RLN Recessed LED luminaire

Transcription:

5/8" 5 7/16" 6 1/2" 2 5/8" 5/8" 6" 5 7/16" 1 11/16" Fixture Type: Project Name: Ordering Guide Feature Code Options Description Program SAE SAE Program Series Recessed Linear Wall/Slot Ceiling Type DW Drywall Ceiling G Grid Row Length (in feet) ' Enter in foot increments Max Length in row 02 2', 609mm 03 3', 914mm 04 4', 1219mm 06 6', 1829mm 08 8', 2438mm Shielding Position R/ Regressed Lens S/ Sheilding at Top Diffuser BWO Blade Baffle with Overlay* SGL Soft Glow Lens *S sheilding only Finish/Color C1 Matte White Color Temperature 30K 3000K Output/ft (specifiable in 50 lumens/ft increments) 35K 40K 3500K 4000K D040 400 D100 1000 Driver NDM Non Dimming D01 1% Dimming, 0-10V DS1 D00 Soft-Start 1% Dimming Dim-to-off DS0 Soft-Start Dim-to-off (1%) LEC LTW Circuiting 1C 1 Circuit Lutron Ecosystem Dimming Voltage UNV Universal Voltage 120 120 Volt 240 240 Volt 277 277 Volt Hi-Lume 1% 2-wire LED driver (120V forward phase only) Straight Run Termination _EC End Cap. Enter quantity. _SE Straight Extension, 2" - 12." Enter quantity. 2 5/8 2.6".6" 5.4" 6.5" CROSS SECTION S/SGL GRID CEILING Key Features: Vi Technology for specifiable output/wattage System connectors allow continuous slot around room, even around corners Easy installation with wall-mounting rail and hook-andlock system Floating ceiling effect Performance 6.6" 2.6" 5.4" 6" CROSS SECTION R/SGL DRYWALL 1.7" Nomenclature Lumens/ft W/ft Efficacy D040-S/ 400 5.41 74 D050-S/ 500 6.39 78 D060-S/ 600 7.38 81 D070-S/ 700 8.13 86 D080-S/ 800 9.35 86 D090-S/ 900 10.65 85 D100-S/ 1000 12.03 83 **Based off of 4' S photometry** **12.5% Expected Loss for R option** (Wattage may vary up to 5% from published) 6.6" Page 1/6 Rev. 04/11/18

Ordering Guide (continued) Optional Features Code Options Description Wall Color Shield WCS Wall Color Shield Only available with the R/shielding options. Chicago Environmental Air Modification CCEA Chicago Environmental Air Modification Nightlight _NL Nightlight Circuit Required. Enter quantity. 2NL= 2 nightlight circuits/row Emergency _EF Emergency Battery Required. Enter quantity. 2EF= 2 emergency batteries/row *Available only in 4' or greater lengths Thru-wiring W1 No Thru Wire W2 W3 Provide Normal and Emergency Thru Wiring* Provide Normal Thru Wiring Only *Only applicable when specified with emergency Emergency Exceptions Value Direct Output- Total lm/ft Exclusions D090-D100 900-1000 Excludes S/ shielding options on 4' D080-D100 800-1000 Excludes R/ shielding options on 4' Page 2/6 Rev. 04/11/18

Y Details Construction: Housing: Die-formed steel. Contact factory for details. Finish/Color: Visit www.litecontrol/resources/finishes for details. Color Temperature: 30K- 3000K output multiplier.975 35K- 3500K output multiplier 1.00 40K- 4000K output multiplier 1.00.43 Fixture Support Rails: Extruded aluminum wall-mounted rail that provides fixture support and, along with provided splines, ensures fixture alignment. Provides reveal at wall to compensate for wall construction irregularities. White color. Diffuser: BWO Blade Baffle, White. 3/8" high and 1/2" OC painted steel. Only available in S/ position. SGL Soft Glow Lens. Extruded, frosted acrylic. Available in R/ or S/ position. Circuiting: 1C (1 Circuit) Fixture wired for a single circuit..40 ANSI 3000K Nightlight: See separate LC-Nightlight spec sheet for additional details..35 ANSI 4000K ANSI 3500K.35.40.45.50 Color Variation: 2 step MacAdam ellipse X Output (VI technology): Variable Intensity (VI) technology allows precise specification of fixture output/ wattage. Fixture will be programmed and labeled to specification. Output: Specify in 50 lumen increments within the below range: Lumens/ft Nomenclature Min: 400 D040 Max: 1000 D100 Driver: NDM: Non-dimming. Fixture will be wired for fixed light output. D01: 100%-1% dimming range. Fixture will be wired for low voltage 0-10V dimming control. DS1: Soft-Start 100%-1% dimming range. Fixture will be wired for low voltage 0-10V dimming control. D00: Dim-to-off 100%-1% Dimming range. Fixture will be wired for low voltage 0-10V dimming control. DS0: Soft-Start Dim-to-off 100%-1% dimming range. Fixture will be wired for low voltage 0-10V dimming control. LEC: Hi-Lume 1% EcoSystem LED Driver with Soft-on, Fade-to-Black dimming technology LTW: 100%-1% dimming range. Lutron 2-wire 120V forward phase control dimmer compatible using Hi-lume 1% 2-wire (LTE series) LED driver. Emergency: Integral-Bodine BS310LP or Iota CP07 (Consult factory if specific application is required.) Inverter-Compatible. Provided by others. Thru-Wiring: See separate LC- Thru Wire spec sheet for additional details. Row Joining: Each row joining used #8-32 machine screws/nuts for pulling the fixture flush at the end header location. Field accessibility: Lens, LED boards and drivers can be accessed and removed from installed fixture. LED boards can be replaced either individually or as part of module. Rated Life: Test in accordance to the LM79-2008 and derived from EPA TM-21 calculator L70: 257,000 (calculated per TM-21 extrapolated curve) L70: >61,000 (reported per TM-21/LM80 6x's limitation) L90: 66,000 (calculated per TM-21 extrapolated curve) L90: >61,000 (reported per TM-21/LM80 6x's limitation) Fixture Weight: 3.75 lbs/ft. Ratings: CSA listed for damp locations. Warranty: LED boards- 5 years LED drivers (standard)- 5 years LED drivers (Lutron)- 3 years DW (Drywall/Plaster) G (Lay-In Grid) R/ (Regressed) S/ (At Top) Page 3/6 Rev. 04/11/18

Product Specifications System Connectors _EC _SE _IC _OC _AIC _AOC End Cap kit. Quantity Required. Straight Extension, 2"-12". Quantity Required. 90º Inside Corner, 8"-18". Quantity Required. 90º Outside Corner, 2" -11 1/4". Quantity Required. 135º Angular Inside Corner, 4 1/2" -14 1/2". Quantity Required. 135º Angular Outside Corner, 2"-11 1/2". Quantity Required. 24" Length also available, contact factory. IC AOC AIC EC SE OC See web site for installation details. Planning for Installation Pre-installation notes: Finish of wall should extend 7" above ceiling. Continuous Fixture Support Rail is provided for ease of installation. Ceiling construction must be supported independently of the lighting. Fixture Lengths: 24", 36", 48", 72" and 96" Straight Extension Inside Corner Fixture Support Rail furnished in 8-foot lengths, extruded aluminum for easy cutting T-bar clips Field-cut filler pieces, lay in Outside Corner Ceiling support wires, by others End Cap Wall Angle Furnished in 8-foot lengths, field cut to length. For use with R/position lens Ceiling system supplied by others, must be self-supporting and provide ceiling trim member for the fixture Extension Shield Fixture interconnection by others bottom of ceiling 1. Install Fixture Support Rails on walls. 2. Hook fixtures on rail and slide into position. 3. Install extensions and corners. 4. Attach Extension Shields to components. Page 4/6 Rev. 04/11/18

Details (continued) Color Characteristics: Value Ordering Code 30K 35K 40K Rf 81 82 82 Rg 99 97 95 CCT (K) 3137 3583 4158 Duv -0.0027-0.0019-0.0018 x 0.4239 0.3989 0.3727 y 0.3927 0.3832 0.3680 CIE Ra 82 83 84 Spectral Distribution: SPECTRAL POWER DISTRIBUTION COMPARISON Relative Power 100% 80% 60% 40% 20% 30K 35K 40K 0% 380 430 480 530 580 630 680 730 780 Wavelength (nm) Color Vector Graphic: 30K: Color Gamut/Fidelity Plot 140 130 R f -R g Plot 1 2 Approx. limits for sources on the Planckian locus. Approx. limits for practical light sources. 120 110 35K: Reference Illuminant Test Source Gamut Index, R g 100 90 80 70 40K: Reference Illuminant Test Source 60 50 60 70 80 90 100 Fidelity Index, R f CRI: 80 minimum CCT CRI R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 30K 82 81 89 95 80 80 85 84 63 13 74 79 68 82 97 97 83 81 89 94 81 81 85 86 65 14 74 79 65 83 97 40K 84 83 90 94 81 82 85 87 68 18 75 79 61 85 97 Reference Illuminant Test Source Page 5/6 Rev. 04/11/18

Photometry Fixture: SAE-D130-2-R/SGL-C1-30K-D130-D01-1C-UNV-W1 CCT: 30K Output: D130 Nominal lumens: 2600 lumens Efficacy: 63 lm/w Test report: 17.00734 450 90 75 60 Zonal Lumen Summary Zone Lumens Lamp% 0-40 1356.36 52.3 0-60 2168.77 83.5 0-90 2597.34 100 90-180 0.6 0 900 45 1350 0 15 30 LEGEND 0-deg 90-deg 180-deg Fixture: SAE-D070-2-S/SGL-C1-30K-D070-D01-1C-UNV-W1 CCT: 30K Output: D070 Nominal lumens: 1350 lumens Efficacy: 83 lm/w Test report: 17.00604 210 90 75 60 Zonal Lumen Summary Zone Lumens Lamp% 0-40 700.25 52 0-60 1118.6 83 0-90 1347.04 100 90-180 0.65 0 420 45 630 0 15 30 LEGEND 0-deg 90-deg 180-deg Page 6/6 Rev. 04/11/18