Prediction of Air Flow, Temperature and Humidity Patterns in a Pilot Plant Spray Dryer

Similar documents
CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

Chapter 2 Computational Fluid Dynamics Applications in Spray Drying of Food Products

WHAT IS IMPORTANT IN THE SIMULATION OF SPRAY DRYER PERFORMANCE AND HOW DO CURRENT CFD MODELS PERFORM?

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Heat transfer and heating rate of food stuffs in commercial shop ovens

Heat Transfer in Evacuated Tubular Solar Collectors

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Study of air circulation inside the oven by computational fluid dynamics.

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Computational Study of Effects of Drop Size Distribution in Fire Suppression Systems

A Study of Drying Uniformity in a New Design of Tray Dryer

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Improvement on the Efficiency of Condensing Units: Analysis of the CoolNSave. Jillian Chodak Suzanne Murphy

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Improvement on the Efficiency of Condensing Units: Analysis of the AC Precooling machine. Jillian Chodak Suzanne Murphy

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Compression of Fins pipe and simple Heat pipe Using CFD

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Energy Efficient Liquid Desiccant Hybrid Air Conditioning System

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Analysis of ventilation system for a microwave assisted drying unit

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Sprinklers Modeling for Tunnel Road Fire Fighting

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Performance Analysis of Axial Flow Cooling Coil and Mixed Flow Cooling Coil in a Cold Storage using Numerical Method

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

International Journal of Food and Biosystem Engineering. May 2015 Vol. 1, No. 1. Optimisation of industrial Food Drying Operation. Henry T.

Numerical Analysis of Water Temperature Distribution in the Tank of. ASHPWH with a Cylindrical Condenser

Numerical study of heat pipe application in heat recovery systems

COOLING SYSTEMS FOR CONTINOUS GALVANIZING LINE Miroslav Raudensky a, Milan Hnizdil a, Jaroslav Horsky a, FrédéricMarmonier b

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Mallikarjun 1, Anandkumar S Malipatil 2

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

American International Journal of Research in Science, Technology, Engineering & Mathematics

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

DESIGN AND MANUFACTURING OF CHEMICAL AGITATOR

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

AIR FLOW CHARACTERISTICS IN AN INDUSTRIAL WOOD PALLET DRYING KILN

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

Design And Analysis Of Centrifugal Pump

Computational simulation of road tunnel fire protection by sprinklers

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Agitation and Mixing

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Stock Vessels for Improved Quality and Energy Savings

Investigation of moisture content fluctuation in mixedflow

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

2. HEAT EXCHANGERS MESA

Steam condensation in a 2D model of an annular gap steam injector

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

14 Drying. I Basic relations and definitions. Oldřich Holeček, Martin Kohout

Air Flow Study inside the Supermarket Refrigeration System

Refining and Petrochemical Heater trouble shooting

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Effect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension in a Standard Flat Bottom Agitated Vessel

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Transcription:

Nahrain University, College of Engineering Journal (NUCEJ) Vol.13 No.1, 2010 pp 55-65 Prediction of Air Flow, Temperature and Humidity Patterns in a Pilot Plant Spray Dryer Saad Nahi Saleh Chemical Engineering Department, College of Engineering, University of Tikrit E mail: saad_nahi68@yahoo.com Abstract This paper presents the prediction of air flow, humidity and temperature patterns in a cocurrent pilot plant spray dryer fitted with a pressure nozzle using a three dimensional model. The modeling was done with a Computational Fluid Dynamic package (Fluent 6.3), in which the gas phase is modeled as continuum using the Euler approach and the droplet/ particle phase is modeled by the Discrete Phase model (Lagrange approach).good agreement was obtained with published experimental data where the CFD simulation correctly predicts a fast downward central flowing core and slow recirculation zones near the walls. In this work, the effects of the air flow pattern on droplets trajectories, residence time distribution of droplets and deposition of the droplets on the wall also were investigated where atomizing of pure water was used. Introduction Spray dryer is an essential unit operation for the manufacture of many products with specific powder properties, e.g. chemical, ceramic, food; pharmaceuticals etc. In spite of the wide uses of the spray dryers, they are still designed mainly on the basis of experience and pilot experiment [1]. One of the big problems facing spray dryer designer and operators is the complexity of the spray/air mixing process in spray chamber [2] where the air flow patterns existing inside the spray dryer is considered as one of the primary factors that influence the residence time of droplet / particle, in turn the equality of the product produced by the dryer such as moisture content, size distribution, and bulk density. The particle residence time and surrounding air temperature are particularly important in the spray drying of thermal sensitive products, such as milk, where product degradation can occur if the particles remain in an air stream for too long, or experience an air stream is too hot [3]. A very important phenomenon of spray dryer operability is the particle wall deposition which is affected by the temperature and humidity patterns inside the dryer when moist particles contact the spray dryer wall. Such depositions can lead to a build up large amounts of product on the wall. These depositions may be dangerous, as they can fall and cause damage to the chamber walls, or they can char, resulting in a potential explosion hazard [4]. Application of computational fluid dynamic (CFD) techniques in analyses of spray dryers have been carried out successfully and reported by Oakley et al. [5], Kieviet [6] and others. Most of these earlier works assume the flows in the dryers are two-dimensional and axisymmetric in order to reduce the demand on computational resources. There is clear experimental evidence to demonstrate three dimensional behavior in this type of equipment suggesting that numerical simulations of spray dryers need to include the three-dimensional nature of the flows[7]. Previous twodimensional, axisymmetric simulations can only be regarded as indicative, at best, since they do not reproduce the basic physics that are involved [8]. As explained above, it is apparent that in order to avoid wall buildup and insufficient residence time of particle which influences the product quality, we must able to model of the complexity of the spray/air mixing and understand what happened inside the spray dryer? The evaporation of pure liquid droplets has been extensively studied for many years, e.g., Ranz and Marshall [9];Manning [10] and Crowe[11]. Part of the reason why these systems were among the first to be studied is that they are considerably simpler than those involving a higher content of dissolved/suspended solids. Understanding such processes is not only commercially important in itself, e.g., for modelling fuel atomisation in engines, but conclusions drawn from their study also form the basis for understanding more complicated drying mechanisms [1,12]. NUCEJ Vol.13 No.1 Saleh 55

Modelling Approach The flow in a spray dryer is turbulent and two-phase (gas and droplets or gas and particles). There are two commonly used approaches for modeling two-phase flow [13]. Firstly, one can treat the disperse phase as an extra fluid with its own flow field (Euler/Euler approach). In the case of spray drying, with rather concentration of particles, one usually use the second approach, the Euler/ Lagrange approach. In this approach the gas field is calculated first (Euler). This is done by calculating solutions of the Navier-Stockes and continuity equation on a grid of control volumes. Subsequently the particles are tracked individually (Lagrange). Along the particle trajectories the exchange of mass, energy and momentum with the continuous phase is calculated. These transfer terms are added to the source terms of the Navier-Stokes equations of the gas flow calculation. After the particle tracking, the air flow calculation pattern is recalculated, taking the transfer terms into account. This cycle of airflow calculation followed by particle tracking is repeated until convergence is reached. This scheme is called the Particle-In-Cell model [14]. The droplet field is established by integrating the differential equations for droplet motion to determine droplet velocities and, with further integration, droplet trajectories. At each time step along the trajectory, droplet size and temperature history are calculated using the equations for droplet mass and heat transfer rates. These equations can be found in [15, 16]. Since space is limited, they are not repeated here. The evaporation rate of the spray is modeled using simple drying kinetics where dm dt k c A d M w C C w, s w, Where the evaporation rate is governed by gradient diffusion, with the flux of droplet vapour into the gas phase related to the gradient of the vapour concentration between the droplet surface and the bulk gas. The concentration of vapour at the droplet surface is evaluated by assuming that the partial pressure of vapour at the interface is equal to the saturated vapour pressure, P at the droplet temperature, P sat C w, s 2 RTd T d : 1 sat The concentration of vapour in the bulk gas is calculated by: p Cw, X w 3 RT Where X w is the local bulk mole fraction of water vapour, P is the local absolute pressure, and T is the local bulk temperature in the gas. The mass transfer coefficient in Eq. (1) is calculated from the Sherwood number correlation [9]: Sh k d c d 1 2 1 3 AB 2.0 0.6Red Sc 4 Di, m The effect of turbulence on the droplet motion is modeled by the turbulent stochastic model. Turbulent stochastic tracking of droplets admits the effect of random velocity fluctuations of turbulence on droplet dispersion to be accounted for in prediction of droplet trajectories [17]. Case study For CFD simulation, the spray dryer used in this article is a co-current pilot plant spray dryer by Niro Atomizer as shown in Fig.1. The geometry and air inlet size are the same as those used by Kieviet [6]. The nozzle atomizer is located at the top of the drying chamber; hot drying air enters the chamber through an annulus with the nozzle as its centre. The outlet of the spray dryer is a pipe mounted through the wall of the cone section of the chamber, bent downwards in the centre of the chamber. This type of spray dryers is a more complex geometry than the simple box configuration, which requires an unstructured mesh for accurate representation using 740000 tetrahedral mesh elements (Fig. 2). To check whether the solution was dependent on the mesh which had chosen, the mesh was refined to 1100000 elements. For each element of original mesh, the value of axial, radial and tangential velocities was compared with the corresponding values in refined mesh. The differences were smaller than 4%, therefore we can say that solution is mesh independence. As a first step, the modeling of the air flow without spray and swirl is performed. A second step will be the modeling the temperature and humidity when pure water droplets are tracked through the air under operational conditions with 5 swirl degree. For modeling the air flow without spray, the velocity components (axial, radial and NUCEJ Vol.13, No.1 Air Flow, Temperature and Humidity 56

tangential) of inlet air were: 6.03,-4.22 and 0.0 m/s respectively. The nozzle was a hollow-cone-type centrifugal pressure nozzle (Spraying Systems Co: SX-type, spray angle 76 o C) with initial velocity of 49 m/s. A spray is represented by a 10 droplet sizes, ranging from 10 to 138 m. Rossin Rammler distribution parameters for 42 kg/hr of feed pure water are mean diameter and power of 68.6 m of 2.45 respectively Fig 1: The geometry of the pilot plant spray dryer (the dimensions in mm) Fig. 2: surface mesh for the pilot plant spray dryer NUCEJ Vol.13 No.1 Saleh 57

Table 1. Boundary conditions used for case study Air flowrate (m 3 /s) Air temperature ( o C) Air humidity(kg w /kg a ) Feed temperature ( o C ) 0.42 195 0.009 27 Air axial velocity Air radial velocity Air tangential velocity Swril Degree (m/s) (m/s) (m/s) 7.42-5.19 0.649 5 Pressure at outlet Turbulence - k - value Turbulence- --value Chamber wall thickness (Pa) (m 2 /s 2 ) (m 2 /s 3 ) (m) -150 0.027 0.37 0.002 Wall material Wall heat transfer coefficient (W/m 2.K) Air temperature outside wall ( o C ) Wall boundary condition Steel 3.5 25 Escaped Boundary Conditions A k model was chosen to model the turbulence. The k model is the most commonly used in engineering practice because it convergence considerably better than the algebraic stress model (ASM) and Reynolds stress model (RSM) and require less computational effort [6]. To determine the fate of the droplet trajectory when hit the wall of the drying chamber, Fluent [15] submit multi options that could selected for the present work. The possible fates for a droplet trajectory are as "escaped", "trapped", "evaporated', "reflected" and "coalesced". In this work, 300 droplet trajectories were calculated and the "escaped" boundary condition is used, where the droplets are lost from calculation at the point of impact with the wall. Of each droplet trajectory, the time of flight and the location of the end -point were recorded. In order to compare the CFD predicted results with experimental results of Kieviet [6], the same conditions were used as tabulated in Table 1. Results and Discussion Analysis of the CFD simulation of air velocity profile without spray in the spray dryer, as shown the contour of air velocity (Fig.3) and the vector plot of the simulated air flow field (Fig.4), showed that the flow field consists of a fast flowing downward core with a slow recirculation around that core near the upper section of the conical part of the chamber. The core broadens as going down to the outlet. The predicted and measured velocities at different levels are depicted in Fig.5. One note that the central core is of the radius of about 0.25m and the reminder of the chamber is at very low velocity (0.2 m/s). The highest velocity magnitude in the core is about 7.3m/s at the 0.3m level. The sharp descent of velocity magnitude at the axis of the chamber is reduced as the air goes into the cone section of the chamber as shown in Fig.6 which shows the predicted and measured velocity for at different levels for region of radius 0.25m. This trend is agreed very well with the measured results. Only the predictions of velocity magnitudes at 1.0 m level are somewhat higher than the measured values. We expect the reason is that the air flow reveals periodicity in the velocity magnitude at several locations in the chamber and the 1.0 m level is one of its. This nature of air flow was noticed by Kieviet[6] when measuring the velocity signal in these locations. Therefore we can say that the air flow in this pilot plant spray dryer is transient in nature and we need a transient CFD simulation to consider this behavior. In Fig. 7and 8, the predicted counters of temperature and humidity of air with spray are depicted. From these figures, it can seen that a large volume of the chamber has almost constant temperature and humidity(107 o C, 0.04 kg w /kg a ). It appears that most of the evaporation takes place in the fast flowing core. It is practical to compare the predicted values with the measured values at certain points like outlet. As shown in Fig. 7 and 8, the predicted value of temperature and humidity at outlet are 99 o C and 0.04 kg w /kg a but the measuring values at outlet are 86 o C and 0.04 kg w /kg a. This difference in temperature due to under estimation of wall heat transfer coefficient which is used to consider the heat loss from wall. Although of this, the predicted results agree very well with the measured results. NUCEJ Vol.13, No.1 Air Flow, Temperature and Humidity 58

In Fig. 9, the vector plot of the predicted air velocity showed that the center of recirculation flow moved upward and toward the right side of the chamber in the case with spray and consequently the droplets flow in a large circle in this region resulting in an increase of the residence time (3.45 s) and promote the wall deposition as shown in Fig 10. This phenomena because of the coupled effect of momentum transfer between the air and spray, therefore we can say that effects of droplets / particles on the gas flow pattern are strong, although that the hypothesis which ignoring the effects of droplets on the gas flow pattern if the feed rate is less than 10% of the gas mass flow rate [18,19]. In Fig. 10, a 300 droplet trajectories which represent the spray of 10 droplet sizes are predicted. As can be seen, a bigger droplets (greater than 95 m ) appear to be able to penetrate the fast flowing core into the slow recirculation zone whereas the smaller droplets are trapped in this core where the massive evaporation occur for this smaller droplets in the core region due to high air temperature as shown in contour of temperature pattern (Fig.7). We find that a large fraction of the droplets is evaporated (65%), 26% of the droplets hit the conical part of the chamber wall, 7.5% of the droplets hit the cylindrical part of the chamber wall, and 1.5% of the droplets hit the roof. It is expected that this large deposition at the conical part is because of the air flow pattern effects in this region where the air approaches the wall at right angles, the air velocity is zero, and this location can be considered as stagnation point (Fig.11) which reveal higher deposition. This explanation is consistent with the measured results of Kota [20]. It is generally assumed that the residence time distributions of the particles/droplets are equal to those of the air [1]. Little research has been published on the actual residence times of particles in spray dryers [6, 21], with air flow rate 0.421 m 3 /s, a mean residence time of air is (24.2 s) in this dryer [6]. Analysis of CFD simulation shows that mean droplets residence time in the dryer (2.4 s) is shorter than mean air residence time due to high initial droplets velocity. Conclusions The CFD simulations correctly predict the internal behavior of the spray dryer. It discerned that the air flow at specified conditions consist of fast flowing core and slow recirculation zone around it, and the air flow reveals a periodicity in some locations in the dryer which can simulated by a transient CFD model. The evaporation of droplet take place in the core region where the smaller droplets evaporated due to high air temperature. There is a the coupled effect of momentum transfer between the air and spray resulting in a modifying of the droplet trajectory and affect the evaporation of droplets, further it relating to some phenomena such as wall deposition which is considered a serious problem when drying a real material. NUCEJ Vol.13 No.1 Saleh 59

Fig. 3: Contour of predicted air velocity in the spray dryer chamber (without spray) Fig. 4: Vector plot of the predicted air velocity in the spray dryer chamber (without spray) NUCEJ Vol.13, No.1 Air Flow, Temperature and Humidity 60

Fig. 6: Predicted and measured velocities at different levels measured from the ceiling (0.3, 0.6, 1.0 m)in the region of 0.25 m of spray dryer chamber Fig. 7: Contour of predicted air temperatures ( o C) distribution in the spray dryer chamber (with spray) NUCEJ Vol.13 No.1 Saleh 61

Fig.8: Contour of predicted air humidities (kg w /kg a ) distribution in the spray dryer chamber (with spray) Fig. 9: Vector plot of the predicted air velocity in the spray dryer chamber (with spray) NUCEJ Vol.13, No.1 Air Flow, Temperature and Humidity 62

Fig. 10: Predicted droplet trajectories (300 droplet tracks represent a 10 droplet size distribution) in the spray dryer chamber Fig. 11: Vector plot of the predicted air velocity in the lower conical of the spray dryer chamber NUCEJ Vol.13 No.1 Saleh 63

A C D d k m P R T t Nomenclature Re X subscript d s w d w, s W, m d c M Sc Sh w w sat droplet surfacearea concentration of diffusion cofficient droplet diameter masstransfer coefficiet moleculer weight of droplet mass pressure universalgas constant temperature time Reynoldsnumber Schmidt number Sherwoodnumber molefraction droplet droplet surface saturation water bulk air References vapour kmol/ m m/ s vapour kg/kmol 1- Masters, K., Spray Drying Handbook, 4th ed., John Wiley and Sons, New York, 1985. 2- Oakley, D., "Produce uniform particles by spray drying", Chem. Eng. Prog., October, pp. 48-54, 1997. 3- Harvie, D.J.E., Langrish, T.A.G and Fletcher D.F., "A computational fluid dynamics study of a tall-form spray dryer". Trans. IChemE C, 80(3), 163-175, 2002. 4- Harvie, D.J.E.; Langrish, T.A.G.; Fletcher, D.F., "Numerical simulations of gas flow patterns within a tall-form spray dryer". Transactions of the Institution of Chemical Engineers,79 (3) A, 235 248, 2001. 5- Oakley, D.E.; Bahu, R.E.,"Computational modeling of spray drying,comput". Chem. Eng. 17 (1993) 493-498. 6- Kieviet, F.G. Modelling Quality in Spray Drying. Ph.D. thesis, Endinhoven University of Technology, the Netherland, 1997. m K s - - - 2 2 m / s m kg pa - 3 7- Southwell, D.B.; Langrish, T.A.G., "Observations of flow patterns in a spray dryer". Drying Technology, 18 (3), 661 685, 2000. 8- Langrish, T.A.G.; Fletcher, D.F., "Prospects for the Modelling and Design of Spray Dryers in the 21 st Century". Drying Technology, 21 (2), 197 215, 2003. 9- Ranz, W.; Marshall,W., "Evaporation from drops". Chem Eng. Prog.,48(141),173,1952. 10- Manning, W. P. and Gauvin, W. H., "Heat and Mass Transfer to Decelerating Finely Atomized Sprays", AICHE J., 6, 2, pp. 184-190, 1960. 11- Crowe, C.T., "Modelling spray-air contact in spray-drying systems. In Advances in Drying", Mujumdar, A.S., Hemisphere New York, Vol. 1, 63 99, 1980. 12- Handscomb, C., Kraft, M., Bayly, A., "A new model for the drying of droplet contaiing suspended solids", University of Cambridge, 2007 13- Sommerfeld, M., "Review on numerical modeling of dispersed two phase flows", Proc. 5 th Int.Symp. on Refined Flow Modelling and Turbulence Measurements, Paris, 1993. 14- Crowe, C.T., Sharma, M.P., Stock, D.E., " The particle-source-in-cell (PSI-Cell) model for gas-droplet flows", Journal of Fluid Engineering, 99, 325 332, 1977. 15- Fluent Manual, "Chap. 23: Discrete phase models", www.fluent.com, 2006. 16- Al-Hemiri, A. A., Saad N. Saleh, "Computer Aided Design for Spray Dryers", Iraqi J.of Chem. And Petro. Eng., 8 (1),27-34,2007 17- Haung, L.; Kumar, K.; Mujumdar, A. S., "A Pararmeteric Study of the Gas Flow Patterns and Drying Performance Of Cocurrent Spray Dryer", Drying Technology, 21, 6, pp.957-978, 2003. 18- Reay, D., "Modelling continuous convection dryers for particulate solidsprogress and problems", Drying 85, 5, pp.67-74, 1985. 19- Elghobashi, S., "On predicting particleladen turbulent flows", Applied Scientific Research, 52,309-329, 1994. 20- Kota, K., Langrish, T., "Prediction of Deposition Patterns in a Pilot-Scale Spray Dryer Using CFD Simulations", Chem. Prod. and Proc. Modeling, 2(3), 26, 2007. Pham, Q. T., Keey, R., B., "Some experiments on the residence- time distribution of droplets in a cocurrently worked spray chamber", Can. J. Chem. Eng., 55(44),pp. 466-470,1977. NUCEJ Vol.13, No.1 Air Flow, Temperature and Humidity 64

E-mail : saad_nahi68@yahoo.com Fluent6.3 Lagrange approach CFD NUCEJ Vol.13 No.1 Saleh 65

This document was created with Win2PDF available at http://www.daneprairie.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only.