Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

Similar documents
POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

Airfield lighting. Product Brochure

Vigilant LED Based Obstruction Lights

Equipment for your Heliport

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Helideck Lighting Systems to meet CAP437 7th Edition

Research and Development Update

Vigilant LED Based Obstruction Lights

Vigilant LED Based Obstruction Lights

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

ICARO Aircraft Warning Lights

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Applications. Standard Materials

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

2015 NEW PRODUCTS. NOW EXPORTING THE UTAC-STS! THERMAL CLIP-ON WEAPON SIGHT WITH AN IR LASER POINTER.

Rugged LED shelter lighting

Obstruction Lighting

Date: 3/11/2019 Initiated By: AAS-100

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

Eye Protection. For the Ultimate in Performance and Protection

ICARO. Aircraft Warning Lights GENERAL CATALOGUE.

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Airport Visual Aids Updates

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

Infrared LED Light - 3 watts - stud mount v - 750nm, 850nm or 940nm

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Obstruction Lighting Guide

LMV Series W Low Profile - Medium Base

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

High Intensity LED Strobe Light - 10 Watt - 10~30 Volts DC - Permanent Mount - 14 Strobe Patterns

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

DMV Series W For Combustible Dusts

DURABLE LIGHTING MADE FOR MARINE

The light must never go out. Gustav Dalen Winner, Nobel Prize, 1912

ELECTRICAL LIGHTING VENTILATION SOLUTIONS.

This is a preview - click here to buy the full publication

Lighting for Hazardous & Severe Environments

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Hazardous Area Ringdown Telephone

Flame Detection Jon Sarfas

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Optics & Radiometry Laboratory

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

INSTRUCTION MANUAL DIRL-GL

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Phoenix s expertise in the marine market. Progress

GD OTS Canada Small Caliber IR Cartridge Development

OL10A & OL32 Obstruction Light

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

INTERNATIONAL STANDARD

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

AVIATION LIGHTING. Commercial Products Catalog 2014

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant

INFRARED WINDOW SERIES

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Public Hearing, July 12, 2018

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

HIGHLANDS COUNTY LAND DEVELOPMENT REGULATIONS DIVISION 8. MILITARY AIRPORT OVERLAY

TAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

Aetos Overview. Mistras Internal and External Customers 03/27/2017 R1.4 D E L I V E R I N G A S S E T P R OT EC T I O N S O LU T I O N S GLO BALLY

POLESTAR II SERIES HL /01

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

IF IT S NOT LIT, IT S NOT SECURE ADVANCED PERIMETER SECURITY OUR LIGHTS ARE YOUR MOST ACTIVE DETERRENT. STOP INTRUDERS BEFORE THEY ACT FLASH GLARE

American Railway Engineering and Maintenance of Way Association Letter Ballot. Draft

AV-OL-ILAB-UM-R & AV-OL-FL810-UM-R Universal AC Low Intensity Obstruction Light Installation & Service Manual

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Transcription:

Heliport & Helideck Lighting System For Non Hazardous and Hazardous Locations Option: Marine Treatment for superior corrosion protection

2 PRODUCTS & SERVICES Index FATO Perimeter Lights TLOF Touchdown Lights Landing Direction Lights Floodlighting Lighted Wind Cones Heliport Beacons Heliport Lighting Controllers Certified FAA Lighting Manufacturer ISO 9001: 2008 Registered ETL, UL, ABS & ATEX Listed Manufacturer ARRA & Made In USA Qualified Manufacturer FAA Certified Wind Cones & Airfield Lighting Heliport & Offshore Helideck Lighting Airfield Lighting Products Obstruction Lighting Systems ABOUT POINT LIGHTING Point Lighting Corporation was founded in 1993 by a group of airfield lighting professionals dedicated to the values of service, quality and expertise in the fields of aviation heliport lighting and airfield lighting. Point Lighting uniquely combines in one company years of experience in aviation lighting manufacturing, marketing and international sales. The company has special expertise in application engineering for heliport and offshore helideck lighting projects including hospitals, oil rigs and marine vessels. Point Lighting Corporation also manufactures airfield lighting products and exports 60% of its sales. Point Lighting Corporation products are Made in USA and certified to FAA, ICAO, ATEX, CSA and numerous other applicable standards of safety and quality. TRADEMARKS The TWIN POINTS logo, company name and POINTUSA are registered trademarks of POINT LIGHTING CORPORATION and all legal protections will be enforced. POINTLIGHTING.COM is the web domain name registered with VeriSign and it is the property POINT LIGHTING CORPORATION. QUOTATIONS & PRODUCT APPLICATIONS All quotations are subject to the receipt of accurate and complete information from the requestor. Quotations are firm for thirty (30) days; Scheduled ship dates represent the best estimates of POINT LIGHTING CORPORATION and its suppliers at time of quotation and do not constitute fixed promises. POINT LIGHTING CORPORATION will assist in the design and specification of systems and products when requested. It is the responsibility of the customer to insure the proper application and installation of all products. Liquidated damages are not accepted in any form by POINT LIGHTING CORPORATION. WARRANTY The standard warranty for products manufactured by POINT LIGHTING CORPORATION is one (1) year from the date of ex-factory shipment except as modified in writing. For products altered in any way or improperly installed in the opinion of POINT LIGHTING CORPORATION, the warranty is void. The "Limited Product Warranty" below applies to all products of POINT LIGHTING CORPORATION manufacture. Consumable parts such as lamps, fuses, etc are not covered by this warranty. Parts damaged by lightning, line surges or other such damage outside our control are not covered by this warranty. For products not of POINT LIGHTING CORPORATION manufacture, POINT LIGHTING CORPORATION will be responsible only to the extent of the original equipment manufacturers written warranty and its application to the claim in question.

3 Heliport & Helideck Products A D B C F G E Heliport Lighting System: A. FATO Perimeter Lights B. TLOF Touchdown Lights C. Landing Direction Lights D. Floodlighting E. Lighted Wind Cones F. Heliport Beacons G. Heliport Lighting Controllers

4 A - FATO Perimeter Lights Final Approach & Takeoff Area (FATO). A defined area over which the final phase of the approach to a hover, or a landing is completed and from which the takeoff is initiated. FAA recommends a minimum of sixteen (16) green perimeter lights with spacing not to exceed 25- ft. ICAO recommends white lights spaced not to exceed 5-meters. In practice, many smaller helipads use eight (8) lights. These lights may be semi-flush inset, low surface mounted at less than 6-inch height or elevated on FAA frangible couplings. The light source may be LED or incandescent. LED lights are available with optional NVG compatibility as described in the catalog. PEL-57004 PEL-97004 LP34 PEL-97004 JBS 3 PEL-97004 LSM MT PRL-97704 PRL-90000 PRL-97004 EX LSM PRL-97004 PLS B - TLOF Touchdown Lights Touchdown and Lift-off Area (TLOF). A load bearing, generally paved area, normally centered in the FATO, on which the helicopter lands or takes off. The TLOF lights, when not doubling as the FATO, are semi-flush and vary in number and pattern. They are generally symmetrical with the FATO lights and thus closer spaced. The light source may be green LED or incandescent. LED lights are available with optional NVG compatibility as described in the catalog. PRL-97704 MT PRL-97004 EX PRL-97004 PLS PRL-97704 EX C - Landing Direction Lights FAA recommends a five (5) yellow landing direction lights for each preferred direction of approach extending in a line with 15-ft spacing. These lights may be semi-flush inset or elevated on FAA frangible couplings. The light source may be LED or incandescent. LED lights are available with optional NVG compatability as described in the catalog. PRL-97004 PLS PEL-57004 PRL-97004 LP34

5 D - Floodlighting Floodlighting must not present glare to the pilot or be so bright as to interfere with aircraft operations. It is not necessary to provide an even footcandle level across the pad. The floodlights will generate cones of light across the landing surface that will provide depth perception to the pilot by eliminating the "black hole" effect. PSF-53025 (LED) PHF-53004 PHF-53002 PHL-57004 PSF-57224 PSF-53005 (Halogen) E - Lighted Wind Cones A PWC wind cone may be FAA L-807 style with a rigid hinged base pole and overall height of about 22-ft. This type is normally for ground mounting. Or it may be FAA L-806 type lightweight and about 10-ft tall. The 806 is usually installed on a roof with Point Lighting safety options including a stainless steel tether. Both styles use the same 8-ft long tapered windsock and the same internal or external lighting. The light source may be LED or incandescent. The wind cone should be sited away from obstructions that may interfere with the actual prevailing wind pattern. It should be clear of the landing surface and at right angles to the preferred direction of approach if possible. PWC-8061L PWC-8071L

6 F - Heliport Beacons The PHB Point Heliport Beacon is a medium intensity flashing signal for the pilot to locate the site. It should be mounted at the highest point anywhere on the site visible in 360-degrees. PHB-37001 PHB-37001 MT G - Heliport Lighting Controllers Point Lighting Corporation will customize the standard controller types to suit the new and existing heliport site lighting circuits. PHC-61003 SPU-10770 PRC-65001 PHC-61001

7 Offshore Helideck Lighting Marine Vessels Point Lighting Corporation is an FAA certified airfield lighting manufacturer that seeks to attain all relevant product certifications to international standards for heliport and helideck lighting systems. We use third party certification bodies such as INTERTEK and SIRA where defined test standards exist such as FAA, UL Standards, CSA and ATEX. We strive to demonstrate compliance where standards are published without a test regime such as ICAO Annex 14 and CAP 437. Lighting for aviation operations on offshore marine vessels certified to UL1598A per US Coast Guard requirements. Where applicable, CAP 437 compliance and ATEX Zone 1 or Class I, Division 2 listing. Surface mounted or semi-flush mounting and all lights have a special marine treatment for corrosion resistance certified to the highest grade military salt spray test. Point Lighting recognizes the extreme conditions endured in the offshore industry. Our products do not use external plastic components; everything is treated metal and glass in forms that draw upon our long experience with methods for resistance to corrosion and water ingress as required by US Military and FAA test programs. All cast metal parts are treated for marine conditions by cleaning per US MIL method III of TT-C-490, chromate priming per US MIL-C-5541, epoxy powder base coat and glossy polyester powder coat finish coat in color RAL 6003 (FED-STD-595 color #14097) green and oven cured per US MIL-PRF-24712A. This has passed the highest level of salt fog tests. POINTUSA HELIDECK TOUCHDOWN & PERIMETER LIGHTS The PRL-LSM is the perimeter light most often selected for our offshore LED lighting systems. The construction is robust with no plastics. If a semi-flush light is required, the PRL-97704 can be dropped into a cutout in the deck's metal surface. PRL's are in use all over the world. Click our Projects tab for references. A. LED Low Surface Mount Perimeter Lights. PRL-97004-LSM-MT PRL-97704-EX-LSM B. LED Semi-Flush Touchdown Lights. PRL-97704-MT PRL-97704-EX PRL-97004-SR PRL-97704-EX-PLB

8 C. LED Elevated Perimeter Lights. PEL-57004-EX PEL-57004-MT PEL-57004-LSM-MT D. LED or Halogen Surface Floodlights. PSF-53005-MT PSF-53025-MT HELIDECK IDENTIFICATION BEACON & STATUS LIGHT SYSTEM The PHB Point Heliport Beacon is a medium intensity flashing signal for the pilot to locate the site. It should be mounted at the highest point anywhere on the site visible in 360-degrees. The PSL Status Light System complies with CAP 437 for warning of a hazardous condition onboard. PHB-37001-MT PSL-35001 PSL-35002 LIGHTED WIND CONES For offshore sites, the PWC-8061L wind cone is commonly used because it is lightweight and about 10-ft tall. It is available with Point Lighting safety options including a stainless steel tether. The light source may be LED or incandescent. The wind cone should be sited away from obstructions that may interfere with the actual prevailing wind pattern. PWC-8061L

9 HELIPORT Lighting Controllers Point Lighting Corporation will customize the standard controller types to suit the new and existing heliport site lighting circuits. PHC-61003 SPU-10770 PRC-65001 PHC-61001

10 NVG Compatible Lighting Infrared Lighting System Point Lighting Corporation has developed heliport lighting products and systems that are compatible with Night Vision Goggles (NVG) for civilian and military use. Incandescent lighting can be seen by NVG due to the heat signature and the full spectrum emissions of incandescent light. LED lights do not produce significant heat and emit colored light at a single wavelength typically outside the range of NVG reception. Typical Aviator Night Vision Imaging Systems (ANVIS) use so-called "Generation 3" technology which is the current military standard sensing infrared (IR) light in the 600 to 900 nanometer (nm) wavelength range. It is used by military and commercial pilots. Point Lighting IR LEDs emit at 850 nm which is outside the unaided human visual range. Therefore, we have developed certain products intended for use under unaided VFR with NVG compatibility and others are for tactical use with NVG only. The latter will not be visible to unaided eyes. The background information at the link below is partially adapted from the Aviation Research Report B2004/0152 Night Vision Goggles in Civil Helicopter Operations by the Australian Transport Safety Bureau. POINTUSA LED HELIPORT LIGHTS WITH OPTIONAL NVG COMPATIBILITY The LED lights shown at our HELIPORT LIGHTING link are visible under normal VFR operations. With the addition of option -NC NVG Compatibility, infrared (IR) LED's are incorporated in the array to allow the lights to be also seen using NVG. Both types of LED's operate at the same time and no special switching is required POINTUSA LED OBSTRUCTION LIGHTS WITH NVG COMPATIBILITY The POL-21004 is available in a double head version where one head is visible red and the other head is infrared (IR). Both heads may be operated together making the obstruction marking visible both with and without NVG. Or the heads may be switched separately for military applications. Only the IR head is switched to operate under tactical "lights out" conditions and the visible red LED head can be switched ON for normal VFR conditions POL-21004-S-NC POL-21004-S2-NC POL-21004-D2-NC

11 POINTUSA LED HELIPORT LIGHTS FOR MILITARY USE Point Lighting Corporation has various solutions for dual use heliports that must operate some of the time for "lights out" NVG-only night flying. These may be custom LED lights where the IR and visible LED's reside in the same light, but may be remotely switched between the two modes. Contact Point Lighting for this solution. Dual use lights may also be incandescent light source with special lenses and switchable between IR and visible light. IR only lights are also available in either LED or incandescent. P O I N T Principle USA POINT LIGHTING Corporation Plant: 61 West Dudley Town Rd, Bloomfield, CT 06002 USA Mail: P.O. Box 686, Simsbury, CT 06070 USA Telp: 01 860.243.0600 Fax: 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com L I G H T I N G C O R P O R A T I O N Authorized Distributor Indonesia TUNAS CAHYA SENTOSA. PT Komplek Ruko Emerald Boulevard AA2 No 36 Jl. Jombang Raya - Bintaro Jaya Tanggerang Selatan Provinsi Banten Indonesia. 15227 Telp : + 62 21 745 7315 Fax : + 62 21 745 7315 E-mail: salesinfo@tunascs.com