UV Equipment Procurement and Bid Document Preparation

Similar documents
Monthly Operating Report (MOR) Addendum for UV: Calculated Dose Approach

PRECAST CONCRETE. Never Looked So Good!

Section UV DISINFECTION SYSTEM Greater Vernon Water Page 1 of 18 TABLE OF CONTENTS

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

WASTEWATER DISINFECTION

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

Optimization of UV Disinfection

WEDECO Quadron UV System

TROJANUVSWIFT SC. Drinking Water Treatment

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

Professional Amalgam Non-regulated

SECTION ULTRAVIOLET DISINFECTION EQUIPMENT

PRO Series PRO10 PRO20 PRO30

HF Series R_RevB

Section 3: Ultraviolet - UV

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

DRINKING WATER WORKS PERMIT

Instructions for the 4-20mA Unit

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

1020 Industrial Drive, Orlinda, TN fax

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

Preliminary Operations and Maintenance Plan Baron Winds Project

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

6 th Pipeline Technology Conference 2011

Instructions for the 4-20mA Unit

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

'W' HATENBOERWATER Fresh In water since l906.

Blake C. Kronkosky, PE, Ph.D.

Diagnostics with fieldbus

Ultraviolet Disinfection Systems

Olivenhain Municipal Water District (OMWD) REQUEST FOR PROPOSALS. For. Ultraviolet Disinfection System at. 4S Ranch Water Reclamation Facility

A. Product Data: Include rated capacities, furnished specialties and accessories.

> ENERGY NEED FOR A STANDARDIZED SUPERMARKET: HEATING, COOLING, REFRIGERATION. > Deliverable 8. With the support of : November 2007

Fire Smoke Damper Actuator Replacements SECTION COMMISSIONING OF HVAC

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

Customized Drinking Water

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Water engineers and utilities are often

Ultraviolet Disinfection Systems

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

Q9360 Addendum #2 Response to Vendor Questions

State-of-the-art Developments to Save Energy in Coating Drying

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Architectural and Engineering Specification for a. Flash / Flare

O&Ms for Pacific Grove, CA UV System

Michigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

254 Nanometer Germicidal UV Disinfection Systems

Intelligent alarm management

LaserFOCUS VLF-250 Engineering Specification

Spectron LSN (Life Safety Network) Suggested Specifications

Life Cycle Considerations for Microprocessor Relays

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Energy services in North America 2014

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

ULTRAVIOLET (UV) DISINFECTION EQUIPMENT: MAJOR APPLICATIONS AND GLOBAL MARKETS. IAS037C January Shalini Ramamurthy Project Analyst

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

SECTION Free/Available Chlorine Analysis System

Architectural and Engineering Specification for a Real-Time Locating System Flare

Failure Modes, Effects and Diagnostic Analysis

88MLV Series Open Channel Modular UV Systems

Ultraviolet Sterilizers

PIP PCTPA001 Testing of Process Analyzer Systems

City of Duluth Festival Center 04/25

ULTRA-VIOLET STERILIZATION

Understanding the Varying Viewpoints of the Water Utility Provider and Landscape Contractor

Consent Agenda. Meeting of June 14,2018

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

SECTION INTEGRATED AUTOMATION COMMISSIONING

a high level of operational reliability), and the designer (in performing probabilistic-based

Doing Business with Bartlett Cocke General Contractors

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

DR Series Appliance Cleaner Best Practices. Technical Whitepaper

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Design of Multi-Sensors Cooperation Control System for Intelligent Building

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

ENERGY STAR Testing. Pilot Verification Program for Selected ENERGY STAR Products. Richard Karney, P.E.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

PROJECT BACKGROUND. Preliminary Design Scope and Tasks

Annual Testing of Stairwell Pressurization Systems & Other Smoke Management Systems

Summary of 60-Day Notice: Heating Efficiency

Walk in Freezer. Comfortable work environment

Samsung SDS BMS Ver.2.0. Technical Specification

Transcription:

UV Equipment Procurement and Bid Document Preparation Jason Anderson, P.E., 1 * Courtney Eaton, P.E. 2 and Harold Wright, P.Eng. 3 1. Carollo Engineers, P.C. 8911 Capital of Texas Highway North, Suite 2200, Austin, TX 78759 2. Carollo Engineers, Walnut Creek, CA 3. Carollo Engineers, Boise, ID * Corresponding Author: Jason Anderson, Email: janderson@carollo.com ABSTRACT UV disinfection systems for drinking water are offered by many different manufacturers in a variety of configurations. While variety provides benefit to customers allowing them to choose a more optimized system, this same variety creates challenges for UV equipment procurement and bid document preparation, which are critical steps in the overall success of a UV disinfection system project. Equipment procurement options are discussed in this article and a procurement method called the Evaluated Bid Approach is presented. Also discussed is the UV Cost Analysis Tool, or UVCAT, developed by Carollo Engineers, P.C., as part of a New York State Energy Research and Development (NYSERDA) project, and development of UV disinfection system specifications. Keywords: procurement, specifications, selection, cost analysis, equipment INTRODUCTION UV disinfection technology has been evolving in the US from strictly wastewater applications to more frequent drinking water applications. There are many different UV disinfection systems currently available, and most are unique, requiring very specific design for proper application. The overall success of a UV project can be impacted negatively if the equipment installed is significantly different from the equipment on which the design was based. This problem can be avoided early on in the project through the equipment procurement procedure. Carollo Engineers (Carollo) uses an alternative equipment procurement approach referred to as an evaluated bid, and has developed a UV Cost Analysis Tool (UVCAT) and our UV equipment specification to facilitate this approach. The evaluated bid approach to UV equipment procurement, the UVCAT tool, and guidelines for UV system specifications will be presented in this article. The traditional design/procurement approach, illustrated in Figure 1, may not be the best approach for UV system design because commercial UV disinfection systems have important differences, as listed in Table 1, that can significantly impact that design. Figure 1. Traditional Design Approach These differences make it difficult to carry out a detailed design that is open to all commercial UV reactor product lines. Even when narrowing the field to two or three manufacturers, there can be substantial differences among the equipment. Table 1. UV System Features that Impact Design Feature Lamp Type Headloss Reactor Validation Footprint Cleaning System Impact UV EQUIPMENT PROCUREMENT Power Supply Location, Pumping Inlet/Outlet Piping Location, Building Size Water Quality, O&M Four of the more common equipment procurement options are: Design/bid (traditional) Sole source Base bid Pre-purchase A fifth equipment procurement option called the evaluated bid approach can be used. This approach allows UV systems to be evaluated competitively before detailed design begins. With this approach, one UV system is selected from the proposed systems to serve as the Basis of Design. SEPTEMBER 2006 19

Key benefits to an evaluated bid procurement process include: Competitive bids result in a fair price Cost comparison is based on total life cycle costs Additional metrics such as validation testing, installation history, and performance can be evaluated Single UV manufacturer selected early in design phase The evaluated bid process is illustrated in Figure 2. The Design Proposal Request sent to UV manufacturers includes the following requests for information: Equipment specification Preliminary layout Evaluation criteria/analysis description Request for UV system information Figure 2. Evaluated Bid Approach to UV System Procurement General and site-specific UV system performance and design criteria are given to the manufacturers. An example of the criteria sent to manufacturers for a Carollo UV disinfection system project in Tracy, CA is presented in Table 2. Table 2. Example UV System Peformance Criteria Criteria Tracy UV System UV Dose, mj/cm 2 40 UV Transmittance, % 90 System Flow, mgd Maximum 30 Average 17 Minimum 7 Lamp Aging Factor 0.7 Quartz Sleeve Fouling 0.85 Factor System Configuration 2 at nominal (No. of Reactors) 15 mgd each In the Design Proposal Request, the manufacturers are told on what the basis their proposals will be scored. The scoring system used for the Tracy UV system is presented in Table 3. In this example, if a manufacturer scores above zero in both of the Part 1 categories of the evaluation, then their proposal is evaluated further and scored for net present value in Part 2. Part 1 represents non-monetary factors and Part 2 represents monetary factors. Table 3. Scoring System Used for Tracy UV System Criteria Maximum Possible Score Part 1 Reactor Validation 2 Installation Operational Experience 2 Part 2 Net Present Value 4 Total Score 8 Manufacturers evaluated in Part 2 of the evaluation are then compared on an overall net present value basis. One manufacturer is then selected, typically with the highest overall score. The results of the Tracy UV evaluation are presented in Table 4. The Basis of Design for the UV system is then developed based on the selected manufacturer s equipment, as presented in Table 5. Table 4. Results of Tracy UV Evaluation Manufacturer Evaluation Score Criteria A B C Validation Experience 1.0 2.0 2.0 Operation/Installation 0.9 0.9 0.8 Net Present Value 4.0 3.6 4.0 Total Overall Score 5.9 6.5 6.8 System Cost Net Present Value, $M 2.8 3.1 2.8 20 IUVA News / Vol. 8 No. 3

Table 5. Tracy UV Design Criteria Description Criteria Type of Units LPHO Number & Capacity 2 units (15 mgd each) per Unit (duty) Number of Lamps 96 per Unit Total Operating 76 Load at Peak Flow, kw Headloss through 16 Unit, inches UV COST/BENEFIT ANALYSIS AND UVCAT The importance of life cycle cost analysis is illustrated by Figure 3. Referring to Figure 3, low-pressure high-output (LPHO) and medium-pressure (MP) UV systems were under consideration for an application. In this example, the MP footprint allows a reduction in UV building size with a corresponding reduction in capital cost. However, the LPHO power requirements are typically less, and thus the LPHO operational costs are less. Considering this operational cost savings, the LPHO system could potentially save more money over the life cycle of the equipment, even though the MP system is less expensive to construct (Note: This is only an example. LPHO life cycle costs are not always lower than MP life cycle costs. Construction issues can favor MP systems, and some MP systems have very efficient UV dose-pacing control philosophies allowing the MP system to compete with LPHO on power to the point where other factors besides power may drive system selection). Figure 3. Importance of Life Cycle Cost Typically, cost analysis includes capital costs, such as the UV reactor, associated piping and valves, the building, power supply and backup power, instrumentation and control, and engineering, and operation and maintenance (O&M) costs such as power, lamp and other component replacement, UV sensor calibration, and labor. Often O&M costs are estimated assuming UV dose pacing only responds to flow. That is, the power costs, lamp and component replacement costs, and labor cost are calculated assuming the UV system on average operates with x lamps on: Average Flow x = No. of Duty Lamps x Design Flow This approach does not account for the impact of UVT, lamp aging, fouling, the efficiency of UV dose monitoring and control, and the validated range on UV system operation. Often factors, such as the efficiency of UV dose monitoring and control, turndown limitations, and the risk of off-spec performance, are treated as non-monetary factors that are qualitatively ranked (e.g., on a scale of 1 to 5). Such ranking systems are arbitrary and subjective. A better approach would be to quantify the impact of these factors on UV system costs. The UV Cost Analysis Tool, or UVCAT, was developed by Carollo for the New York State Energy Research and Development Authority (NYSERDA) project entitled Optimization of UV Disinfection. UVCAT was developed to provide a more realistic and comprehensive model for UV system performance that would allow one to better evaluate UV systems proposed for a given application. UVCAT Input Inputs to the UVCAT model include: Flow, UVT, power quality, and pathogen concentration data over time for the Water Treatment Plant UV system configuration (number of reactors, banks of lamps, etc) Performance and cost data for the UV system components Lamp aging and fouling profiles The UV system s UV dose monitoring and control algorithm A screen shot of the UVCAT worksheet containing a library of dose monitoring algorithms for commercial UV reactors is presented in Figure 4. The UVCAT user references these dose algorithms when they analyze the performance of a given commercial UV system. These algorithms are obtained from the validation reports submitted by UV vendors when they propose on a design job. The example shown in Figure 4 includes algorithms for many of the commercial reactors by WEDECO, Calgon, Trojan, and IDI. Because this data is highly proprietary to the UV vendors, the final version of UVCAT given to NYSERDA will not have these specific algorithms entered. Carollo has password SEPTEMBER 2006 21

protected this information and controls distribution of the software so that this information stays confidential. Instead, each UVCAT user will need to develop their own library of UV dose monitoring algorithms based on data provided by the UV vendors. Figure 4. UVCAT Reactor Model Data An example of flow and UVT data that was entered into UVCAT for a Carollo UV study carried out for one of our clients is presented in Figure 5. The data entered was obtained from a twenty-year simulation of flow and UVT values, based on historic and projected future flows and four years of historic UVT data. The example data chart shows strong seasonal and year-to-year trending that will impact UV system performance over time. Figure 6. UVCAT Input Fields UVCAT Output Outputs from UVCAT include predictions of: Reactors and lamps required to deliver the target UV dose Power consumption UV dose and pathogen log inactivation Off-spec performance Integrated O&M costs Capital and life cycle costs An example of power consumption over time predicted by UVCAT is presented in Figure 7. The software provides the actual power consumed given the turndown of the lamps used by the UV system and the power that would be consumed if the UV system was not limited by turndown. In Figure 7, when the ideal power is greater than the actual power, the UV system cannot deliver the design UV dose and is undersized. When the ideal power is less than the actual power, the UV system is limited by turndown of the lamps and is overdosing. This type of data allows one to understand if the UV system is under-sized or over-sized for a given application and it allows one to understand the efficiency of UV dose pacing. Figure 5. Flow and UV Data Input into UVCAT A screenshot of the UVCAT worksheet used to input data on UV system configurations and performance and costs of UV system components like lamps, sleeves, ballasts, and UV sensors is presented in Figure 6. Each column in the worksheet represents a UV system that can be analyzed. This format is convenient because multiple proposals for a given UV application can easily be analyzed. Figure 7. Power Consumption Predicted by UVCAT 22 IUVA News / Vol. 8 No. 3

An example of off-spec performance of the UV system caused by flow, UVT, lamp aging, and fouling is presented in Figure 8. The off-spec performance is calculated as a monthly off-spec volume and a monthly off-spec time. These data are valuable because it lets the user size UV systems to achieve an off-spec goal, instead of sizing UV systems for worse case flow, UVT, lamp aging, and fouling. Figure 8. Off-Spec Performance Predicted by UVCAT An example of daily and accumulated power costs over time predicted by UVCAT for a given UV system is presented in Figure 9. Such data provides engineers and utilities a much more accurate estimate of UV system O&M costs compared to current rule of thumb approaches used because it includes the impact of factors such as the UV output efficiency of the lamp and ballast, turndown limitations of the UV system, hydraulic limitations of each reactor, the discrete operation of the UV system (e.g. a UV system may have four ballast power settings), and off-spec limitations of validation data. UVCAT integrates accumulated power and component replacements costs to estimate annualized and present worth costs. Figure 9. Power Costs Predicted by UVCAT A screenshot of the UVCAT worksheet used to output UV system cost data is presented in Figure 10. The data provides side-by-side comparisons of UV system alternatives for a given UV application, lending a greater level of accuracy to the Evaluated Bid Approach of equipment procurement. Figure 10. UVCAT Summary Table UVCAT provides a more accurate assessment of O&M and life cycle costs compared to standard approaches used by the industry because it better accounts for the true performance of the UV system. Overall, the software provides a new approach optimizing UV capital and O&M costs and should provide better selection of UV systems for a given UV application. UV SYSTEM SPECIFICATIONS UV disinfection is a well-established technology in the US for wastewater applications. The use of UV disinfection in drinking water applications is much newer to the US market and has experienced considerable change in recent years. Application of UV disinfection in drinking water involves a number of issues that either do not occur with, or have greater emphasis than UV disinfection of wastewater, such as: UV Dose monitoring and UV sensors Ultraviolet Disinfection Guidance Manual (UVDGM) validation and equipment factor calculations Off-spec performance targets Alarms and responses Startup testing and verification The nature of UV disinfection of drinking water is such that the equipment specification is all the more critical as compared to specifications for wastewater applications of UV disinfection. An outline of the main sections included in the Ultraviolet Disinfection System for Drinking Water Application specification developed by Carollo is presented in Table 6. SEPTEMBER 2006 23

Table 6 Example UV System Specification Outlines PART 1 GENERAL 1.1 SUMMARY 1.2 RELATED DOCUMENTS 1.3 REFERENCES, CODES, STANDARDS, AND RECOMMENDED PRACTICES 1.4 DEFINITIONS 1.5 UV SYSTEM DESIGN CRITERIA 1.6 SUBMITTALS 1.7 SPARE PARTS 1.8 GUARANTEES AND WARRANTIES 1.5 UV SYSTEM DESIGN CRITERIA A. UV Installation B. Water Quality C. UV Reactor Sizing Criteria for UV Dose Deliver D. On-line UVT Monitor E. Hydraulic Criteria F. Average Conditions for Net Present Worth Evaluation described in Section 00305 1. Flowrate: mgd 2. UVT: % 3. Lamp aging factor: % 4. Fouling factor: % G. UV Validation H. Electrical Criteria I. Controls Criteria J. Structural Design K. Equipment Mounting and Anchoring 24 IUVA News / Vol. 8 No. 3 PART 2 PRODUCTS 2.1 SCOPE OF SUPPLIES 2.2 MANUFACTURERS 2.3 GENERAL PRODUCT REQUIREMENTS 2.4 MATERIALS 2.5 UV REACTOR CHAMBER 2.6 UV LAMPS 2.7 QUARTZ SLEEVES 2.8 CLEANING SYSTEM 2.9 UV SENSORS 2.10 UV TRANSMITTANCE MONITOR 2.11 OTHER SENSORS 1.6 SUBMITTALS A. Submittal Package No.1 shall include the following information: 5. Dimensional and Cutaway Drawings 6. UV System Parts Lists 7. UV System Sizing 8. Layout 9. Structural 10. UV Irradiation chamber 11. UV Lamps 12. Lamp Ballasts 13. Quartz Sleeves 14. Cleaning System 15. Duty UV Sensors 16. Reference UV Sensors 17. UV Sensor Port 18. Electrical 19. Control and Instrumentation 20. Dose Monitoring Algorithm 21. UV System Control Philosophy 22. Operating and Maintenance Costs B. Submittal Package No.2 shall include the following information: 1. Operation and Maintenance (O&M) Manuals 2. SUPPLIER s delivery instructions. 3. SUPPLIER s installation instructions. 4. Startup, testing, and training plan. 5. Qualifications of SUPPLIER s field representative. 2.12 ELECTRICAL 2.13 CONTROL AND INSTRUMENTATION 2.14 SAFETY EQUIPMENT PART 3 EXECUTION 3.1 GENERAL 3.2 PLANNING AND SCHEDULES 3.3 SPECIAL SERVICES 3.4 FACTORY TESTING 3.5 DELIVERY, STORAGE & HANDLING C. Submittal Package No.3 shall include the following information: 1. Manufacturer s Guarantee: Submit performance guarantee and guarantee bond. 2. Manufacturer s Warranty: Submit UV equipment warranty. 3. Certificate of Proper Installation. 4. End of Warranty Report. 5. Inspection, Functional Test, Operational Test, and Field Test Reports. 6. Finalized O&M Manuals 7. Record Documentation for all electrical schematics, wiring, diagrams, loop drawings, ladder logic, loop descriptions, and interconnection diagrams.

The point of Table 6 is detail, detail, detail; UV disinfection of drinking water is a very critical application requiring detailed and careful specification. One needs to specify exactly what is required in terms of UV dose monitoring and control, alarms and responses, validation, and system sizing because with UV disinfection of drinking water one cannot measure CT the way one does with chlorine disinfection, or measure coliforms the way one does with the UV disinfection of wastewater. As shown in the example on UV system design criteria presented in Table 6, each section within the specification is also detailed. This level of detail is critical in the evaluated bid approach to UV equipment procurement. It is important to define the requirements for the UV equipment as completely as possible to ensure that the proposing manufacturer has a clear idea of the performance requirements and constraints for the UV system. For example, considering UV installation, what does the system look like, and where will it be installed? Considering water quality, what is the expected range of turbidity, temperature, ph, hardness, alkalinity, calcium, iron, manganese, and aluminum? How exactly is UV dose monitoring and control implemented? How will validation be done, or has it been done to prove UV dose monitoring and control? What is the validated range of the reactor? How does the UV system calculate off-spec performance? Following suit, the submittal requirements are very detailed, and are also critical in the evaluated bid approach to equipment procurement. Submittals provide evidence that the installed UV system will meet the specification. The submittal requirements are also outlined in Table 6. Three submittal packages are required. Submittal Package No. 1 with validation report is to be submitted 90 days after Contractor Notice to Proceed. Submittal Package No. 2 is to be submitted 30 days before shipment. Submittal Package No. 3 is to be submitted before Final Completion. Submittals are checked for compliance with the UV equipment specification. Such checks prevent expensive change orders and retrofits after the UV system is installed. SUMMARY UV disinfection systems are offered in a variety of configurations, and design differences between UV equipment can be significant. The evaluated bid approach to UV equipment procurement allows UV systems to be competitively evaluated before the detailed design. One system is selected from the proposed systems to serve as the Basis of Design. The evaluated bid approach offers many benefits for UV design, including: Competitive bids Life cycle cost analysis Non-economic factors evaluated Single UV system design The UV Cost Analysis Tool (UVCAT) developed by Carollo provides a more accurate assessment of O&M and life cycle costs compared to standard approaches used by the industry because it better accounts for the true performance of the UV system, rather than only looking at design conditions. Overall, the software provides a new approach optimizing UV capital and O&M costs and should provide better selection of UV systems for a given UV application. In this regard, UVCAT facilitates the evaluated bid approach to UV equipment procurement. UV system specification development is a critical step in the overall success of a UV disinfection project. Sufficient detail must be provided to fully describe the application conditions, desired level of disinfection, and equipment features. Detail is particularly important when using the evaluated bid approach for UV equipment procurement. ACKNOWLEDGEMENTS Thanks to those who contributed to this article: NYSERDA and the AWWA Research Foundation Lighting Research Center, Rensselaer Polytechnic Institute City of Troy, NY UV Vendors: Calgon Carbon, ITT WEDECO, Trojan Technologies, Infilco Degremont UV Validation Centers: Portland, OR and DVGW, Germany REFERENCES Eaton, C.L., Wilkins, K.A., England, S.K., and Wengrin, D. Alternate Design and Procurement Approach for UV Disinfection Systems. CDROM Proc. AWWA 2004 Annual Conference & Exposition, Orlando, FL, June 13-17, 2004. American Water Works Association, Denver, CO. Wright, H., Dzurny, T. and Fonseca, C. 2004. New Tools for Optimizing UV Disinfection Life Cycle Costs. CDROM Proc. Water Quality Technology Conference, San Antonio, TX, November 14-18, 2004, American Water Works Association, Denver, CO. SEPTEMBER 2006 25