Stopper II Heated Enclosure

Similar documents
STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Illuminated Stopper Station Push Button

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Stopper II SERIES ADA. We protect the things that protect you

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Addendum for STI-6406 with Dual Access Control

Installation and ZONES: Operation Manual. Model: ON STI-34108

INSTALLATION INSTRUCTION In-Ground

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

INSTALLATION INSTRUCTION In-Ground Color Changing

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Location Requirements

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

USER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

User Manual. Glass Countertop Mechandiser Refrigerator. Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW

Lumination TM Volumetric Retrofit Kit

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for models:

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for models:

SPECIFICATIONS. Contents List

USER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Instructions

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

LS Condensate Removal Pump Installation, Operation and Service Instructions

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Installation Instructions

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

INSTRUCTION & SERVICE MANUAL

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

User Manual AURA ELECTRIC FIREPLAC E

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Series. Access Power Controllers. Installation Guide

Rack Mount Series Installation Guide

AHPO-6/18 GOLD PROOFER OVEN

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

Jetson Mini Stove. Owner s Manual. Item number: ES-312 Model Number: FX3

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

FES - Series Portable Electric Heaters

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

4100U City and Relay Cards Installation Instructions

AGA TOTAL CONTROL. Model No. - TC3

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

User Manual. Commercial Refrigerator And Freezer User s Manual

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

MDG78 Parts Manual. Phase 8. For Internal Use Only RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Technical Manual for the Strobe - SM87 HXB

Wiring Instructions (01-09)

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Installation Instructions

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

THERMAL MANAGEMENT SOLUTIONS

Introduction to Flow Switch

Installation Instructions

200i User s information manual

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Custom Duct Heaters. Special Applications

MANUAL RESET ALARM RELEASE

THERMAL MANAGEMENT SOLUTIONS

SEL-3422 Motor Relay HMI Quick-Start Guide

IMPORTANT INSTRUCTIONS READ & SAVE

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Cold Deck Canopy and Shelf Lights and Retrofit Kit

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Drying Cabinet Installation and Operating Manual

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Installation Operation Maintenance

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Viking Installation Guide

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Construction Electrical

SAFETY INFORMATION AND WARNINGS

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

Transcription:

Stopper II Heated Enclosure STI-1200A-HTR STI-1200A-HTR240 ADA Compliant Maintains initiating device temperature with external temperatures to -70 F (-57 C). Independently tested to -102 F (-73 C). Protects initiating devices for addressable units to UL 38 Standards. The clear, protective polycarbonate cover is UV-stabilized against discoloration. Enclosure rated to NEMA 3R Standards to provide a degree of protection against rain, sleet, and damage from external ice formation. Fan runs continuously to maintain a uniform temperature inside the enclosure. Heater units cycle as required to maintain the correct range of operating temperatures. Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). UL/ULC Listing does not require standby or secondary power for 110 or 240 VAC 50/60 Hz heater. We protect the things that protect you.

Warnings and Installation Notes The enclosure is used to protect UL Listed 38 and 2017 initiating devices at temperatures down to -70 F (-57 C). It is the installer s responsibility to comply with NEC 70 Articles 725 and 760, NFPA 72, and other applicable fire and electrical codes. Conduit or raceway paths need to be sealed as near to the enclosure as possible. Installer should have maintained supervision over the low temperature thermostat. The low temperature monitoring thermostat makes the circuit at +32 F (0 C) and clears the circuit at +50 F (+10 C). This listing requires that the fire alarm supervisory control module be only of the latching type. On the appliance mounting plate is a label where you should record the installation date. Also include below the serial number and installation date on the instruction sheet for quick reference. Serial Number Installation Date NOTE: Operating voltage for the STI-1200A-HTR is 110 VAC. Operating voltage for the STI-1200A-HTR240 is 240 VAC. 1. Use of an outdoor rated initiating station is required with this heated enclosure. 2. When conducting periodic testing, if conditions are dusty or if you have wind blown dust conditions, cover return grill ports to minimize entrance of dust or sand particles. To remove accumulated dust or sand particles, use small containers of compressed air that is used for electronic cleaning. 3. To reset the thermal circuit breaker push button. If circuit breaker will not remain in a restored or closed position, conduct an electrical check of the various components in the two voltage classes. The two voltage classes are 24 VDC Negative Ground and 110 or 240 VAC 50-60 Hz with connected electrical or earth ground. High voltage (110 or 240 VAC) wiring must enter through bottom conduit. Low voltage and signaling wires must enter through top conduit and remain separated per NFPA 70, NEC, and local codes. 4. If the thermal circuit breaker has tripped (opened circuit), the 110 or 240 VAC 50-60 Hz power will still be energized up to the primary side of the thermal breaker. For safety, disconnect supply power of conductors to three power circuits in the enclosure. 5. To clean 24 VDC negative ground fan with electronic compressed air container, disconnect all power. Note: the 24 VDC negative ground fan will not operate if positive and negative conductors are connected on the wrong terminals. 6. To minimize arid summer time heat build up in enclosure, install a dark color sun shield with sides to provide shade for the enclosure. At the inclined face above the enclosure at the point of contact with the building structure leave at least 1/2 or (1.25 cm) space. This will generate heat and cause an upward airflow and help maintain the enclosure temperature approximately the same as ambient air temperature. 7. The 110 or 240 VAC single phase 50-60 Hz heater does not require standby or secondary power because the enclosure environment is supervised by a latching supervisory circuit in the alarm control unit or panel. 8. Replacement of heater assembly and gasket is required five years from installation date. Contact STI to order replacement Heater Kit STI-HK3. 9. All field wiring within this enclosure must be rated for a minimum operating range of 0ºC - 110ºC. Mises en garde et remarques sur l installation Le boîtier est utilisé pour protéger les dispositifs de déclenchement homologués UL 38 et 2017 à des températures allant jusqu à -70 F (-57 C). Il incombe à l installateur de se conformer aux articles 725 et 760 de la NEC 70, NFPA 72, et aux autres codes de prévention des incendies et de l électricité en vigueur. Les chemins des conduites ou canalisations doivent être scellés aussi proche que possible du boîtier. Il est attendu que l installateur ait effectivement contrôlé le thermostat à basse température. Le contrôle du thermostat à basse température maintient le circuit à 32 F (0 C) et déclenche le circuit à 50 F (10 C). Cette homologation exige nécessite que le module de contrôle de la surveillance des alertes d incendie soit uniquement du type à verrouillage. La plaque de montage de l appareil comporte une étiquette sur laquelle vous devez enregistrer sa date d installation. Le numéro de série et la date d installation doivent aussi être marqués sur la feuille d instruction pour référence rapide. Numéro de série Date d installation REMARQUE: La tension de service du STI-1200A-HTR est de 110 VCA. La tension de service du STI-1200A-HTR240 est de 240 VCA. 1. Use of an outdoor rated initiating station is required with this heated enclosure. 2. When conducting periodic testing, if conditions are dusty or if you have wind blown dust conditions, cover return grill ports to minimize entrance of dust or sand particles. To remove accumulated dust or sand particles, use small containers of compressed air that is used for electronic cleaning. 3. To reset the thermal circuit breaker push button. If circuit breaker will not remain in a restored or closed position, conduct an electrical check of the various components in the two voltage classes. The two voltage classes are 24 VDC Negative Ground and 110 or 240 VAC 50-60 Hz with connected electrical or earth ground. High voltage (110 or 240 VAC) wiring must enter through bottom conduit. Low voltage and signaling wires must enter through top conduit and remain separated per NFPA 70, NEC, and local codes. 4. If the thermal circuit breaker has tripped (opened circuit), the 110 or 240 VAC 50-60 Hz power will still be energized up to the primary side of the thermal breaker. For safety, disconnect supply power of conductors to three power circuits in the enclosure. 5. To clean 24 VDC negative ground fan with electronic compressed air container, disconnect all power. Note: the 24 VDC negative ground fan will not operate if positive and negative conductors are connected on the wrong terminals. 6. To minimize arid summer time heat build up in enclosure, install a dark color sun shield with sides to provide shade for the enclosure. At the inclined face above the enclosure at the point of contact with the building structure leave at least 1/2 or (1.25 cm) space. This will generate heat and cause an upward airflow and help maintain the enclosure temperature approximately the same as ambient air temperature. 7. The 110 or 240 VAC single phase 50-60 Hz heater does not require standby or secondary power because the enclosure environment is supervised by a latching supervisory circuit in the alarm control unit or panel. 8. Replacement of heater assembly and gasket is required five years from installation date. Contact STI to order replacement Heater Kit STI-HK3. 9. All field wiring within this enclosure must be rated for a minimum operating range of 0ºC - 110ºC. - 2 -

Polycarbonate Cleaning Instructions Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth. Rinse once more, then dry with a soft cloth or chamois. Exercise caution when using water inside enclosure. Make sure unit is completely dry inside before reassembling. Do not use razor blades. Specifications Internal Dimensions PART # HEIGHT WIDTH DEPTH 1200A-HTR 6.25 in. 4.125 in. 1.25 in. 1200A-HTR240 (158mm) (104mm) (31mm) Polycarbonate Enclosure Flammability UL94 V-2 Wall Thickness back box:.20 inches (5.1mm) cover:.12 inches (3.1mm) NEMA Rating 3R Warranty Lifetime against breakage in normal use. Silicone Laminate Heater STI-1200A-HTR 110 VAC 50/60 Hz STI-1200-A-HTR240 240 VAC 50/60 Hz 100 Watts Life: @-10 C (14 F) ~ 70 C (158 F) UL Recognized Component UL Recognized Component 5 Years Duty Cycle: -40 F (-40 C) 16% -79 F (-57 C) 38% -99 F (-73 C) 100% Fan 24 VDC (±10%), 90 ma UL Recognized Component Life 5 Years Continuous Duty WARNING: The polarity of the circulating fan is important as it only rotates in one direction with red lead being positive. MISE EN GARDE: La polarité du ventilateur de circulation est importante car il ne tourne que dans un sens avec son fil rouge étant celui du pôle positif. Gasket Material Life Neoprene 5 Years - 3 -

Installation Instructions Mount Enclosure back box - Refer to Fig 1 1. Set heater assembly with cover aside. Press (4) plastic tabs into slots on back box and drill (4) 1/4 (6.4mm) diameter holes in mounting surface for plastic anchors provided. Attach back box to wall using (4) #10 x 1-1/2 screws provided. 2. Attach 3/4 rigid conduit and conduit sealing hub (Crouse-Hinds 3/4 EYSX 21 or equivalent) to back box. Conduit should be installed according to applicable NEC and local codes. LOW VOLTAGE WIRE INPUT SEALING HUB DRILL (4) 1/4 in. (6.4mm) DIAMETER HOLES 8 7/16 in. (214mm) 3/4 in. NPT MALE NIPPLE MOUNTING TAB BACKBOX 4 3/8 in. (111mm) MOUNTING SURFACE SCREW ANCHORS 3/4 in. NPT MALE NIPPLE SEALING HUB HIGH VOLTAGE WIRE INPUT #10 x 1 1/2 in. PAN HEAD SCREW Fig. 1 3. Pull 24 VDC and alarm wiring into back box through top conduit; and pull 110 or 240 VAC wiring into back box through bottom conduit per NFPA 70, NEC and local codes. Note: Wire size to be 12-22 AWG. Install Fire Alarm Pull Station and Dual Monitor Module to Heater and Cover Assembly - Refer to Fig 2. 4. Lift the cover from heater assembly and allow it to hang from cables. Connect the provided high temperature wires to the pull station. 5. Attach the pull station to the slide plate using (2) #6-32 x 3/8 screws provided. Adjust the slide plate so the pull station or slide plate does not cover either the fan opening or vent slots. Note: If the fan opening or vent slots are covered, the plate mounting screws can be moved to the alternate mounting position. After mounting pull station adjust the slide plate so there are no gaps large enough to touch the heaters behind the pull station. 6. Turn assembly over and mount dual monitor module to the backside of the heater assembly using (4) #6-32 x 1 screws and (4) 3/8 standoffs provided. Replace cover. - 4 -

COVER AND HEATER ASSEMBLY #6-32 x 1 in. PAN HEAD SCREW 3/8 in. STANDOFF DUAL MONITOR ADDRESSABLE MODULE (NOT INCLUDED) 24 VDC TERMINAL BLOCK WARM AIR DUCT (DO NOT COVER WITH PULL STATION) FAN HIGH VOLTAGE TERMINAL BLOCK SLIDE PLATE PULL IN CASE OF FIRE #8-32 x 3/8 in. FLAT HEAD SCREW PULL STATION (NOT INCLUDED) VENT SLOTS (DO NOT COVER WITH PULL STATION) Fig. 2 Wiring 7. Wire one channel of the dual monitor module to the low temp warning terminals (pins 1 & 2) on the 24 VDC terminal block. Wire the other channel to the fire alarm terminals (pins 5 & 6) on the same terminal block. Add any end of the line devices as required for the alarm system. 8. Connect wires from alarm panel to the dual monitor module according to design specifications. Connect continuous 24 VDC supply to fan power terminals (pins 3 & 4) of the 24 VDC terminal block. Note: 1. Fan is polarity sensitive and must be connected correctly for fan to operate. 2. Fan operates continuously. 9. Connect the 110 or 240 VAC supply to the high voltage terminal block pins 4, 5, and 6. Earth Ground, AC Low, and AC High respectively. 10. Attach the heater and cover assembly to the back box with (4) #8-32 x 3/4 socket cap screws and (4) #8 flat washers. 11. Record installation date in space provided on the label located on underside of cover. Unit is ready for testing. 12. Turn all power to ON position. Note: Fan runs continuously. This system requires three sources of power: 1. 110 or 240 VAC heater on the load side of the fuse holder. 2. 24 VDC power source for the circulating fan. Check fan to see if operating; if not check polarity and reverse, then try again. 3. Fire alarm initiating circuit and temperature warning monitor. - 5 -

SEALING HUB 3/4 in. NPT MALE NIPPLE MOUNTING TAB BACKBOX MOUNTING SURFACE SCREW ANCHORS #10 x 1 1/2 in. PAN HEAD SCREW #6-32 x 1 in. PAN HEAD SCREW 3/8 in. STANDOFF DUAL MONITOR ADDRESSABLE MODULE (NOT INCLUDED) 24 VDC TERMINAL BLOCK COVER AND HEATER ASSEMBLY LOW TEMP WARNING THERMOSTAT CIRCUT BREAKER FAN HIGH VOLTAGE TERMINAL BLOCK SLIDE PLATE #8-32 x 3/8 in. FLAT HEAD SCREW PULL STATION (NOT INCLUDED) PULL IN CASE OF FIRE Product Assembly GASKET 3/4 in. NPT MALE NIPPLE SEALING HUB - 6 -

Schematic Diagrams HIGH VOLTAGE CIRCUIT 2 AMP CIRCUIT BREAKER 1 OVERTEMP SAFETY OPEN @ 120 F (40 C) CLOSE @ 80 F (27 C) 2 CLOSE @ 40 F (4 C) OPEN @ 65 F (18 C) CONTROL 3 EARTH GROUND 110 OR 240 VAC SINGLE PHASE 4 5 6 TERMINAL BLOCK CHASSIS HEATER 110 OR 240 VAC 50/60 Hz 100 WATTS FROM MONITOR MODULE TO TEMP WARNING LOW VOLTAGE CIRCUIT 1 2 LOW TEMP WARNING (16-33VDC 600mA) OPEN @ 50 F CLOSE @ 32 F (10 C) (0 C) FAN PWR + 3 4 FAN 24VDC (±10%), 90mA FROM MONITOR MODULE TO MANUAL STATIONS 5 6 MANUAL STATIONS TERMINAL BLOCK - 7 -

Warranty Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14. 2306 Airport Rd Waterford, MI 48327, USA Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 info@sti-europe.com www.sti-europe.com Subject to change without notice. Printed in USA Inst. Sht.1200A HTR MARCH2006