Shaking Peltier Device

Similar documents
Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

PolyBox TM. Edition II. Operation Manual

KMART Corrective Action Plan

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

A New Generation of Active Intrusion Detection System for Physical Protection

Register your product and get support at 在以下网站注册并获得支持

CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

LEVEL SENSORS & FLOAT SWITCHES

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

TECHNICAL PRODUCT DATASHEET

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

MultiTemp IV Thermostatic Circulator

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Always there to help you

English (original instructions) 2 中文 ( 简体 ) 7 繁體中文 11 한국어 15. Copyright DeWALT

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

RAS-DX18HDK/RAC-DX18HDK

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

WAT E R S O U R C E H E AT P U M P S

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

Senab Interior established on the Bund introducing Scandinavian design and new ways to organize the office

compact Bagless Cyclonic Vacuum Cleaner IMPORTANT: Read carefully before assembly and use.

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

Prospects and challenges for sustainable urbanization in China

Premium Desoldering station with Electric Pump Ref. DIS-D

Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

Gas Pipeline Locating Leak detection and Safety Assessment

Rosemount 848T High Density Temperature Measurement Family

矿用电缆 矿 用 电 缆 江苏亨通电力电缆有限公司

Kitchen Exhaust Duct (KED) Requirements

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

Hitachi Highly. Spezifikation Manual

PREVENT ALL INJURIES IN THE KITCHEN. GO HOME SAFE AND HEALTHY.

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

Hot Air Station without Extractor desk Ref. JTSE-QA

IMPORTANT: Read carefully before assembly and use Techtronic Floor Care Technology Limited. All Rights Reserved.

Personal Care Appliances in Sweden

qianlong garden restoration project 乾隆花园修复工程

SUNSTAR 单片机专用电路 TEL: FAX: Features 6 Digit 6 Function LCD Alarm Watch with RGB LE

Personal Care Appliances in Thailand

PMAC202 Branch Circuit Power Meter User Manual V1.0

8 Filtration Systems Air Purifier 8 重過濾空氣清新機 User Manual 產品說明書

R-S32EPH R-S32EPHL

BUREAU VERITAS GREATER CHINA 必维国际检验集团 大中华区 CRANE SERVICES 起重机服务

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

PE Series Jaw Crusher P E

AirFloss Ultra. 5_020_9188_2_DFU-Booklet_A6_v3.indd 1 21/09/16 09:11

The Home Depot Quality System Audit. * Example Report * North America Latin America

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

Award-winning and absolutely new, Very stacks, swivels, and flexes far beyond ordinary seating to inject comfort and life into any space.

Collaborative efforts for sustainable campus 可持续校园建设多方协作机制的初探

TRANSPORTATION EXISTING 交通现状

brass material mould. 500USD (2 pcs) Baby safety swab 500USD (2 pcs) Cosmetic swab brass material mould. 500USD (2 pcs) Cosmetic swab

GreenUp Lowbay G2 BY288P. Lucia Liu Indoor Segment, PLP Growth Market Feb. 2016

Installation Instructions for the MICRO SWITCH VPX Series Valve Position Indicator for Hazardous Locations

Work Report of Chinese Steering Commi.ee of Landscape Architecture Educa8on

FOB NINGBO PORT PRICE: 29,000USD

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

Midea Vacuum Cleaner. User Manual VC-35A1Q3

Tokyo Gas Engineering Solutions Corporation

PAC-10P PAC-15P. 移動座地式冷暖空調 Portable Reverse Cycle Air Conditioner 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

Beijing Urban Design Studio Summer 2008

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

Cooker Hood User Manual

COMPARATIVE ANALYSIS AND PEDESTRIAN SIMULATION EVALUATION ON EMERGENCY EVACUATION TEST METHODS FOR URBAN RAIL TRANSIT STATIONS

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

即熱式電熱水器即热式电热水器. Instantaneous Water Heater 使用說明書

GAS STAINLESS COOKTOP

Jiangbei New District, Nanjing ISOCARP Urban Planning Advisory Team Report

践行里约 +20 决议, 示范新型城镇化 : 国际人居环境范例新城倡议

DIGITAL ARIA FRYER 電子控制無油煎炸鍋 MODEL NO.: GAF W A GILMAN GROUP BRAND

GPI-M3 USER MANUAL. Instantaneous Electric Water Heater F O R 1 3 A S O C K E T

HTO-124. Oil-Filled Heater USER MANUAL

MicroCoat Flow Guard Operating Manual

The Professional Laundry Experience

KTV-215 真空無線控溫電熱水壺 U S E R M A N U A L 使用說明書. Cordless Temperature Control Vacuum Kettle P.1 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

HTRF. SpectraMax Paradigm Cisbio HTRF Detection Cartridge. User Guide

亚太地区世界遗产培训与研究中心 ( 上海 ) 简讯 World Heritage Institute of Training and Research - Asia and Pacific, Shanghai

MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

Plant Safety 沼气厂安全. Raphael Thies and Dr Katharina Backes

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Operating Instructions Air Conditioner

KKKKKKKHud Dapur Panduan Pengguna

Owner s Manual / 使用手冊

CKF-110. Express Healthy Air Fryer USER MANUAL

Oven toaster EOT3818K EOT5818K

丹麦,Fuglsang 美术馆 / Tony Fretton Architects

RECENTLY, multicarrier modulation techniques, such

New Town Development and Practices

Transcription:

Shaking Peltier Device Integration Manual Biomek 3000 Laboratory Automation Workstation Beckman Coulter PN A36985 Revision AC February 2010 Beckman Coulter, Inc 250 S. Kraemer Blvd., Brea, CA 92821 Copyright 2010 Beckman Coulter, Inc.

ii Except as provided in writing signed by an officer to Beckman Coulter, Inc., this system and any related documentation are provided as is without warranty of any kind, expressed or implied, including that the system is error free. This information is presented in good faith, but Beckman Coulter, Inc. does not warrant, guarantee, or make any representations regarding the use or the results of the use of this system and related documentation in terms of correctness, accuracy, reliability, currentness, omissions, or otherwise. The entire risk as to the use, results, and performance of this system and related documentation is assumed by the user. Except as expressly provided herein, Beckman Coulter, Inc. makes no other warranty, whether oral or written, expressed or implied, as to any matter whatsoever, including but not limited to those concerning merchantability and fitness for a particular purpose, nor is freedom from any patent owned by Beckman Coulter, Inc. or by others to be inferred. LIMITATIONS OF LIABILITY Beckman Coulter, Inc. shall not be liable, to any extent whatsoever, for any damages resulting from or arising out of the use or performance of this system and related documentation or the procedures specified in this manual, regardless of foreseeability or the form of action, whether in contract, tort (including negligence), breach of warranty, strict liability or otherwise, and including but not limited to damages resulting from loss of data, loss of anticipated profits, or any special, indirect, incidental or consequential damages. In no event shall Beckman Coulter, Inc. s liability to the user exceed the amount paid by the user to Beckman Coulter, Inc. hereunder. The user assumes full responsibility for the results obtained from the use of this system and related documentation and for application of such results. Beckman Coulter, Inc. Indianapolis, Indiana www.beckmancoulter.com Biomek, SAMI Orca, and the Beckman Coulter logo are registered trademarks and Beckman Coulter and SAGIAN are trademarks of Beckman Coulter, Inc. Microsoft and MS-DOS are registered trademarks and Windows is a trademark of Microsoft Corporation. All other trademarks appearing in this manual are owned by their respective companies. Copyright 2010 by Beckman Coulter, Inc. All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, or stored in a database or retrieval system, without the prior written permission of Beckman Coulter, Inc. Beckman Coulter, Inc.

iii Warranty and Returned Goods Requirements All standard Beckman Coulter, Inc. policies governing returned goods apply to this product. Subject to the exceptions and upon the conditions stated below, the Company warrants that the products sold under this sales agreement shall be free from defects in workmanship and materials for one year after delivery of the products to the original Purchaser by the Company, and if any such product should prove to be defective within such one year period, the Company agrees, at its option, either (1) to correct by repair or at the Company s election by replacement, any such defective product provided that investigation and factory inspection discloses that such defect developed under normal and proper use, or (2) to refund the purchase price. The exceptions and conditions mentioned above are as follows: a. Components or accessories manufactured by the Company which by their nature are not intended to and will not function for one year are warranted only to reasonable service for a reasonable time. What constitutes a reasonable time and a reasonable service shall be determined solely by the Company. A complete list of such components and accessories is maintained at the factory. b. The Company makes no warranty with respect to components or accessories not manufactured by it. In the event of defect in any such component or accessory, the Company will give reasonable assistance to Purchaser in obtaining from the manufacturer s own warranty. c. Any product claimed to be defective must, if required by the Company, be returned to the factory, transportation charges prepaid, and will be returned to Purchaser with transportation charges collect unless the product is found to be defective, in which case the product must be properly decontaminated of any chemical, biological, or radioactive hazardous material. d. The Company shall be released from all obligations under all warranties, either expressed or implied, if any product covered hereby is repaired or modified by persons other than its own authorized service personnel, unless such repair by others is made with the written consent of the Company. e. If the product is a reagent or the like, it is warranted only to conform to the quantity and content and for the period (but not in excess of one year) stated on the label at the time of delivery. It is expressly agreed that the above warranty shall be in lieu of all warranties of fitness and of the warranty of merchantability, and that the company shall have no liability for special or consequential damages of any kind or from any cause whatsoever arising out of the manufacture, use, sale, handling, repair, maintenance, or replacement of any of the products sold under the sales agreement. Representatives and warranties made by any person, including dealers and representatives of the Company, which are consistent or in conflict with the terms of this warranty, shall not be binding upon the Company unless reduced in writing and approved by an expressly authorized officer of the Company. Parts replaced during the warranty period are warranted to the end of the instrument warranty. Note: Performance characteristics and specifications are only warranted when Beckman Coulter replacement parts are used. Shaking Peltier Device Integration Manual

v Safety Information All Warnings and Cautions in this document include an exclamation point, a lightning bolt, or a light burst symbol framed within a triangle. Please pay special attention to the specific safety information associated with these symbols. WARNING: If the equipment is used in a manner not specified by Beckman Coulter, Inc., the protection provided by the equipment may be impaired. Warning and Caution Definitions All Warnings and Cautions in this document include an exclamation point, a lightning bolt, or a light burst symbol framed within a triangle. The exclamation point symbol is an international symbol which serves as a reminder that all safety instructions should be read and understood before installation, use, maintenance, and servicing is attempted. WARNING: A WARNING calls attention to a condition or possible situation that could cause injury to the operator. CAUTION: A CAUTION calls attention to a condition or possible situation that could damage or destroy the product or the operator s work. When this symbol is displayed in this manual, pay special attention to the specific safety information associated with the symbol. Shaking Peltier Device Integration Manual

vi Safety Information Electrical Safety To prevent electrically related injuries and property damage, properly inspect all electrical equipment prior to use and immediately report any electrical deficiencies. Contact a Beckman Coulter Service Engineer for any servicing of equipment requiring the removal of covers or panels unless specifically stated otherwise. High Voltage This symbol indicates the potential of an electrical shock hazard existing from a high voltage source and that all safety instructions should be read and understood before proceeding with the installation, maintenance, and servicing of all modules. Do not remove system covers unless the instructions state explicitly to do so. To avoid electrical shock, use supplied power cords only and connect to properly grounded (three-holed) wall outlets. Use only multiplug power strips provided by the manufacturer. Disposal of Electronic Equipment It is important to understand and follow all laws regarding the safe and proper disposal of electrical instrumentation. The symbol of a crossed-out wheeled bin on the product is required in accordance with the Waste Electrical and Electronic Equipment (WEEE) Directive of the European Union. The presence of this marking on the product indicates that: the device was put on the European Market after August 13, 2005. the device is not to be disposed via the municipal waste collection system of any member state of the European Union. For products under the requirement of WEEE directive, please contact your dealer or local Beckman Coulter office for the proper decontamination information and take back program, which will facilitate the proper collection, treatment, recovery, recycling, and safe disposal of the device. Beckman Coulter, Inc.

Safety Information vii Chemical and Biological Safety Normal operation of the Shaking Peltier Device may involve the use of materials that are toxic, flammable, or otherwise biologically harmful. When using such materials, observe the following precautions: Handle infectious samples according to good laboratory procedures and methods to prevent the spread of disease. Observe all cautionary information printed on the original solutions containers prior to their use. Dispose of all waste solutions according to your facility s waste disposal procedures. Operate the Shaking Peltier Device in accordance with the instructions outlined in this manual, and take all the necessary precautions when using pathological, toxic, or radioactive materials. Splashing of liquids may occur; therefore, take appropriate safety precautions, such as using safety glasses and wearing protective clothing, when working with potentially hazardous liquids. Use an appropriately contained environment when using hazardous materials. Observe the appropriate cautionary procedures as defined by your safety officer when using flammable solvents in or near a powered-up instrument. Observe the appropriate cautionary procedures as defined by your safety officer when using toxic, pathological, or radioactive materials. Note: Observe all warnings and cautions listed for any external devices attached or used during operation of the Shaking Peltier Device. Refer to applicable external device user s manuals for operating procedures of that device. Moving Parts To avoid injury due to moving parts, observe the following: Never attempt to exchange labware, reagents, or tools while the instrument is operating. Never attempt to physically restrict any of the moving components of the Shaking Peltier Device. Keep the Shaking Peltier Device work area clear to prevent obstruction of the movement. Shaking Peltier Device Integration Manual

viii Safety Information Cleaning Maintenance Important Observe the cleaning procedures outlined in this user s manual for the Shaking Peltier Device. Prior to cleaning equipment that has been exposed to hazardous material: Appropriate Chemical and Biological Safety personnel should be contacted. The Chemical and Biological Safety information contained in this user s manual should be reviewed. Perform only the maintenance described in this manual. Maintenance other than that specified in this manual should be performed only by service engineers. It is your responsibility to decontaminate components of the Shaking Peltier Device before requesting service by a Beckman Coulter Service Engineer or returning parts to Beckman Coulter for repair. Beckman Coulter will NOT accept any items which have not been decontaminated where it is appropriate to do so. If any parts are returned, they must be enclosed in a sealed plastic bag stating that the contents are safe to handle and are not contaminated. Beckman Coulter, Inc.

ix Warnings and Cautions Found in this Manual Please read and observe all cautions and instructions. Remember, the most important key to safety is to operate this software and its supporting equipment with care. The WARNINGs and CAUTIONs found within this document are listed below. WARNING: If the equipment is used in a manner not specified by Beckman Coulter, Inc., the protection provided by the equipment may be impaired. CAUTION: Use only the cables that were included with the Shaking Peltier Device. Other cables may result in power or communication problems. CAUTION: Do not overtighten the screws. There is a gap between the tabs on the adapter plate and the Shaking Peltier Device. Overtightening may result in the adapter plate being uneven and affect heating and cooling performance of the Shaking Peltier Device. WARNING: ELECTRICAL SHOCK HAZARD! Checking and changing the coolant requires removing the covers from the Shaking Peltier Device, exposing internal electrical components. Remove covers with care and use caution when servicing the device. Shaking Peltier Device Integration Manual

xi 安全信息 本文件中的所有 警告 和 当心 信息均附有惊叹号 闪电符号或三角形内的闪光符号 请特别注意与此类符号相关的具体安全信息 警告 : 如果以 Beckman Coulter,Inc. 未说明的方式使用器械, 器械提供的保护可能受到损害 警告和当心定义 本文件中的所有 警告 和 当心 信息均附有惊叹号 闪电符号或三角形内的闪光符号 惊叹号符号是国际通用符号, 用于提醒用户在尝试安装 使用 维护和修理之前阅读和理解所有安全说明 警告 : 警告提醒用户注意可能对操作员造成伤害的状况或可能的情形 小心 : 当心提醒用户注意可能损坏或毁坏产品或操作员工作的状况或可能的情形 当本手册中显示该符号时, 请特别注意与该符号相关的具体安全信息 Shaking Peltier Device Integration Manual

xii 安全信息 电气安全 为了防止与电相关的受伤和财产损坏, 所有电气设备在使用前需得到适当检查, 并且任何电气问题需立即报告 除非另有具体说明, 如果任何设备维修需要取下盖板或面板, 请与 Beckman Coulter 维修工程师联系 高压 这个符号指明存在高电压源带来的潜在触电危险 ; 在所有模块的安装 维护及修理前应通读和理解全部安全须知 除非有关指示明确要求取下系统盖板, 请勿取下这些盖板 为了避免触电, 请只使用附带的电源线且插入已适当接地 ( 三孔 ) 的墙壁插座 只使用制造商供应的多插座接线板 电子设备弃置 理解和遵循所有有关电气设备安全和适当弃置的法规十分重要 欧盟 废弃电气和电子设备 (WEEE) 指令 要求产品带有打叉轮箱符号 产品上显示该符号表示 : 该设备于 2005 年 8 月 13 日之后投放欧洲市场 该设备不得通过欧盟任何成员国的市政废品收集系统弃置 如需获得有关 WEEE 指令要求产品的适当防污染和回收计划信息, 请与您的经销商或地方办事处联系, 他们可向您提供适当的搜集 治疗 康复 设备回收和安全弃置的信息 Beckman Coulter, Inc.

安全信息 xiii 化学与生物安全 设备的正常操作可能涉及使用有毒 易燃或在其他方面具有生物有害性的材料 使用此类材料时, 请遵守以下注意事项 : 依照妥善的实验室程序和方法处理传染性样品, 以防传播疾病 使用前遵守原溶液容器上印制的所有注意事项信息 按照您所在设施的废品弃置程序弃置所有废溶液 按照本手册中的说明操作设备, 在使用病理性 有毒或放射性材料时, 采取所有必要的防范措施 液体可能溅洒 ; 因此, 在使用具有潜在危险的液体时采取适当的安全措施, 例如佩戴安全镜和穿戴保护服 在适当隔离的环境中使用有害材料 在通电器械中或附近使用易燃液体时, 应遵守安全管理人员规定的适当防范程序 在使用有毒 病理性或放射性材料时, 应遵守安全管理人员规定的适当防范程序 附注 : 在设备操作过程中遵守所有附加或使用设备的警告和当心提示 查阅适用的器械和设备使用手册中有关该设备的操作程序说明 移动部件 为了避免移动部件造成伤害, 请遵守以下规定 : 切勿在器械操作过程中尝试更换实验室器皿 反应物或工具 切勿尝试以物理形式限制设备的任何移动部件 保持工作场所无障碍物, 防止阻碍设备移动 Shaking Peltier Device Integration Manual

xiv 安全信息 清洁 遵守本用户手册中规定的清洁程序 清洁接触有害材料的器械之前 : 应与适当的化学和生物安全工作人员联系 应查阅本用户手册中包含的化学和生物安全信息 维护 仅限执行本手册中说明的维护程序 本手册中未说明的维护程序应由 Beckman Coulter 维修服务代表执行 重要事项 在请求 Beckman Coulter 维修服务代表维修或将部件送回 Beckman Coulter 修理之前, 您有责任对部件消毒 Beckman Coulter 不接受需要消毒但尚未消毒的任何物品 如果退回任何部件, 必须将部件装入密封的塑料袋内, 并说明袋内的物品无污染, 可安全处理 Beckman Coulter, Inc.

安全信息 xv 本手册中的警告与注意事项 警告 : 如果以 Beckman Coulter,Inc. 未说明的方式使用器械, 器械提供的保护可能受到损害 警告 : 小心 : 请只使用摇动珀耳帖装置附带的缆线 其他缆线可能带来供电或通信问题 警告 : 小心 : 请勿过度上紧螺丝 摇动珀耳帖装置和配接板的舌片之间有一定空隙 过度上紧可能导致配接板不平和影响摇动珀耳帖装置的加热与冷却性能 警告 : 警告 : 触电危险! 检查和更换冷却液时需要取下摇动珀耳帖装置的盖板 ; 这将暴露内部电气部件 请小心取下盖板, 谨慎维修本装置 Shaking Peltier Device Integration Manual

xvii Table of Contents Warranty and Returned Goods Requirements.................................... iii Safety Information.......................................... v Warning and Caution Definitions............................................... v Electrical Safety........................................................... vi High Voltage......................................................... vi Disposal of Electronic Equipment......................................... vi Chemical and Biological Safety............................................... vii Moving Parts.............................................................. vii Cleaning................................................................ viii Maintenance............................................................. viii Warnings and Cautions Found in this Manual.................................... ix 安全信息................................................... xi 警告和当心定义.....................................................xi 电气安全.......................................................... xii 高压......................................................... xii 电子设备弃置.................................................. xii 化学与生物安全.................................................... xiii 移动部件.......................................................... xiii 清洁............................................................. xiv 维护............................................................. xiv 本手册中的警告与注意事项........................................... xv Table of Contents......................................... xvii List of Figures............................................. xix Shaking Peltier Device Integration Manual

xviii Table of Contents 1 Shaking Peltier Device 1.1 Overview............................................................. 1 1.1.1 Control Modes................................................... 2 1.1.2 Reference Documents............................................. 2 1.2 Installing the Shaking Peltier Device........................................ 3 1.2.1 Raising the Biomek 3000 Deck...................................... 4 1.2.2 Installing the Mounting Bracket..................................... 5 1.2.3 Leveling the Biomek 3000 and Mounting Bracket....................... 6 1.2.4 Installing the Shaking Peltier Device.................................. 7 1.2.5 Installing Adapter Plates........................................... 9 1.2.6 Adjusting the Plate Holder......................................... 10 1.3 Setting Up the Shaking Peltier Device in Biomek Software..................... 11 1.3.1 Installing Software for the Shaking Peltier Device...................... 11 1.3.2 Adding the Shaking Peltier Device to the Deck in the Deck Editor......... 14 1.4 Framing Instructions................................................... 16 1.4.1 Attaching the Manual Framing Tool................................. 17 1.4.2 Manually Framing the Shaking Peltier Position........................ 18 1.4.2.1 Using the Graphic Alignment Tool.......................... 23 1.4.2.2 Using the Delta Value and Directional Buttons................. 24 1.4.2.3 Framing the Z-Axis....................................... 26 1.5 Calibrating the Peltier Device Temperature................................. 28 1.6 Using the Shaking Peltier Device in a Method............................... 29 1.6.1 Using the Peltier Step in a Biomek Method........................... 30 1.7 Manually Controlling the Shaking Peltier Device............................. 32 1.7.1 Configuring Options for the Peltier ALP.............................. 32 1.7.2 Performing Actions in the Device Editor............................. 33 1.8 Preventive Maintenance................................................. 35 1.9 Troubleshooting....................................................... 36 Beckman Coulter, Inc.

xix List of Figures Figure 1-1. Shaking Peltier Device...1-1 Figure 1-2. Installing new feet on Biomek 3000 instrument... 1-4 Figure 1-3. Attaching the mounting bracket to the Biomek 3000... 1-5 Figure 1-4. Adjusting the feet on the mounting bracket... 1-6 Figure 1-5. Mounting the Shaking Peltier Device to the bracket... 1-7 Figure 1-6. Connections on Watlow controller for Shaking Peltier Device... 1-8 Figure 1-7. Shaking Peltier Device with 96-well adapter plate... 1-9 Figure 1-8. Adjusting the corner guides of the Shaking Peltier Device plate holder... 1-10 Figure 1-9. Shaking Peltier SILAS Module install... 1-12 Figure 1-10. Installation of Shaking Peltier SILAS Module complete... 1-13 Figure 1-11. Position Properties for Shaking Peltier Device... 1-14 Figure 1-12. Position Properties for Shaking Peltier Device expanded... 1-15 Figure 1-13. Installing the framing tool on the head assembly... 1-17 Figure 1-14. Deck Editor for Biomek 3000 workstation... 1-18 Figure 1-15. Position Properties for a Shaking Peltier Device... 1-19 Figure 1-16. Biomek 3000 Manual Teaching (Warning)... 1-19 Figure 1-17. Manual Teaching if framing adapter is not required... 1-20 Figure 1-18. Loading tool during manual teach... 1-20 Figure 1-19. Selecting target to manual teach position... 1-21 Figure 1-20. Framing to the center of a well... 1-22 Figure 1-21. Manually teaching the X- and Y-axes using the graphic alignment tool... 1-23 Figure 1-22. Manually teaching the X- and Y-axes using delta values and directional buttons 1-24 Figure 1-23. Manually teaching the Z-axis... 1-26 Figure 1-24. Peltier step palette displayed... 1-29 Figure 1-25. Peltier Step configuration... 1-30 Figure 1-26. Selecting the Shaking Peltier Device in the Device Editor... 1-32 Figure 1-27. Peltier ALP configuration options... 1-32 Figure 1-28. ShakingPeltier Device Action Commands... 1-33 Shaking Peltier Device Integration Manual

1 1 Shaking Peltier Device 1.1 Overview The Shaking Peltier Device (Figure 1-1) is a labware positioner with microplate shaking and heating and cooling capabilities from a connected controller. Each Peltier may be equipped with an adapter plate which allows for different labware types to be used with the Peltier device. Adapter plates are available for: flat-bottomed microplates 96-well thermocycler plates 384-well thermocycler plates Figure 1-1. Shaking Peltier Device Shaking Peltier Device Integration Manual

2 Shaking Peltier Device 1.1.1 Control Modes There are two control modes for the Shaking Peltier Device: Biomek Software the Peltier step controls operations on the Shaking Peltier Device during a method. Supplied Watlow Controller manually control without software. Refer to the TEC Control 96 User s Manual for more information. 1.1.2 Reference Documents This manual covers integrating and using the Shaking Peltier Device with the Biomek 3000 in Biomek Software. Refer to the original manuals from the device manufacturer, Inheco, for more information not included in this manual: Thermoshake Heating and Cooling Unit Manual TEC Control 96 User s Manual Biomek 3000 User s Manual Biomek Software User s Manual Beckman Coulter, Inc.

Shaking Peltier Device 3 1.2 Installing the Shaking Peltier Device The Shaking Peltier Device is installed on a special mounting bracket that is installed on the left side of the Biomek 3000 deck in place of the side module. The Shaking Peltier Device may be installed on either of two positions on the mounting bracket. Installing the Shaking Peltier Device on the Biomek 3000 includes: Raising the Biomek 3000 Deck (Section 1.2.1). Installing the Mounting Bracket (Section 1.2.2). Leveling the Biomek 3000 and Mounting Bracket (Section 1.2.3). Installing the Shaking Peltier Device (Section 1.2.4). Installing Adapter Plates (Section 1.2.5). Adjusting the Plate Holder (Section 1.2.6) Shaking Peltier Device Integration Manual

4 Shaking Peltier Device 1.2.1 Raising the Biomek 3000 Deck To install the mounting bracket that holds the Shaking Peltier Device, the Biomek 3000 instrument must be raised by placing new standoffs and feet on the bottom of the Biomek 3000. To raise the Biomek 3000: Note: Placing the new standoffs and feet on the bottom of the Biomek 3000 instrument requires two people. 1. Tilt the Biomek 3000 instrument on its back feet. 2. While one person holds the Biomek 3000, a second person screws a new foot into each of the threaded holes adjacent to the two front feet (Figure 1-2). Threaded hole for new foot Front feet New feet installed Figure 1-2. Installing new feet on Biomek 3000 instrument 3. After the two front feet are inserted, tilt the Biomek 3000 instrument on the front feet and screw a new foot into each of the threaded holes adjacent to the two back feet. 4. Set the Biomek 3000 down and fasten each of the feet using an adjustable wrench. Beckman Coulter, Inc.

Shaking Peltier Device 5 1.2.2 Installing the Mounting Bracket A mounting bracket is installed on the left side of the Biomek 3000 instrument. The mounting bracket contains two positions in which Peltier devices or a Biomek 3000 Labware Positioner may be placed. An optional Disposal Unit may be attached to the left side of the mounting bracket. To mount the mounting bracket on the left side of the instrument: 1. If the Biomek 3000 Side Module is installed on the left side of the Biomek 3000 instrument, remove it (refer to the Biomek 3000 Laboratory Automation Workstation User s Manual, Section 1.3.4.1, Removing Installed Side Modules). 2. Position the upper locating holes marked L on the side of the mounting bracket with the locating pins on the left side of the Biomek 3000 deck (Figure 1-3). Locating pins Locating holes Mounting holes Figure 1-3. Attaching the mounting bracket to the Biomek 3000 3. Using a 3/16 Allen wrench, fasten the two large socket-head cap screws in the two lower mounting holes marked L on the mounting bracket to attach it to the side of the deck (Figure 1-3). Shaking Peltier Device Integration Manual

6 Shaking Peltier Device 1.2.3 Leveling the Biomek 3000 and Mounting Bracket After installing the mounitng bracket to the left side of the Biomek 3000 instrument, the instrument and bracket must be leveled. To level the Biomek 3000 instrument: 1. Adjust the feet on the bottom of the mounting bracket such that the bottom of the mounting bracket clears the top of the feet on the Biomek 3000 (Figure 1-4). Note: If also installing a mounting bracket on the right side of the Biomek 3000 instrument, install both brackets and adjust the feet to clear the Biomek 3000 feet before leveling the instrument. Mounting bracket Biomek 3000 feet Mounting bracket feet Figure 1-4. Adjusting the feet on the mounting bracket 2. Using a bubble level, adjust the feet on the Biomek 3000 instrument to make sure the deck is level. Turn the feet to the left to raise the feet or to the right to lower them. Note: Make sure the deck is level in both the X- and Y-axes. 3. Place the bubble level on the mounting bracket surface and adjust the mounting bracket feet, if needed, until the bracket is level. Beckman Coulter, Inc.

Shaking Peltier Device 7 1.2.4 Installing the Shaking Peltier Device The mounting bracket has two positions in which devices or positioners may be placed. Either a Static Peltier Device, Shaking Peltier Device, or Biomek 3000 Position Holder, in any combination, may be installed in these two positions. To install the Shaking Peltier Device on the mounting bracket: 1. Position the Shaking Peltier Device on the desired bracket location so the locating pins on the bottom of the Shaking Peltier Device slip into the locating holes on the bracket (Figure 1-5). Shaking Peltier Device Thumbscrews Mounting bracket Figure 1-5. Mounting the Shaking Peltier Device to the bracket 2. Fasten the Shaking Peltier Device to the bracket using the thumbscrews on the base of the Shaking Peltier Device. Note: After physically installing the Shaking Peltier Device, add it to the deck in the Deck Editor of Biomek Software. Shaking Peltier Device Integration Manual

8 Shaking Peltier Device CAUTION: Use only the cables that were included with the Shaking Peltier Device. Other cables may result in power or communication problems. 3. Connect the Shaking Peltier Device bundle cord from the Peltier device to the Watlow controller (Figure 1-6). Power switch Serial port Bundle cord connector Main power port Figure 1-6. Connections on Watlow controller for Shaking Peltier Device 4. Connect one end of the RS-485 serial cable to the serial connector on the back of the Watlow controller. (Figure 1-6). 5. Connect the other end of the RS-485 serial cable to the RS-485 end of the 485/ 232 Adapter. 6. Connect the RS-232 end of the 485/232 converter to one of the serial ports on the automation controller PC or the Digi cable. 7. Connect the power cable from the main power port on the back of the Watlow controller to a power supply (Figure 1-6). 8. Power on the Watlow controller using the power switch on the back of the Watlow controller just above the power cable (Figure 1-6). Beckman Coulter, Inc.

Shaking Peltier Device 9 1.2.5 Installing Adapter Plates Before using the Shaking Peltier Device, one of three available adapter plates must be installed. Adapter plates should be chosen based on what type of microplates are used on the Shaking Peltier Device. Each adapter plate provides a different heating and cooling profile that is optimized for specific types of plates or applications. The available adapter plates are: 96-well adapter for use with 96-well thermocycler plates. 384-well adapter for use with 384-well thermocycler plates. no adapter plate the device may be used without an adapter plate for flatbottomed labware. Note: The Shaking Peltier Device must be replaced in the Deck Editor (refer to Section 1.3.2, Adding the Shaking Peltier Device to the Deck in the Deck Editor) and reframed each time the adapter plate is changed (refer to Section 1.4, Framing Instructions). Each adapter plate has three tabs with screw holes To install an adapter plate on the Shaking Peltier Device: 1. Place the adapter plate on the Shaking Peltier Device such that the three tabs align with three of the screw holes on the device (Figure 1-7). Adapter plate tabs Align the tabs over the screw holes on the Shaking Peltier Device. Make sure all four edges of adapter plate are flush with the Shaking Peltier Device. Figure 1-7. Shaking Peltier Device with 96-well adapter plate 2. Make sure the adapter plate is flush with all edges of the interior area of the device. Shaking Peltier Device Integration Manual

10 Shaking Peltier Device CAUTION: Do not overtighten the screws. There is a gap between the tabs on the adapter plate and the Shaking Peltier Device. Overtightening may result in the adapter plate being uneven and affect heating and cooling performance of the Shaking Peltier Device. 3. Fasten the adapter plate to the Shaking Peltier Device using the 1.5 mm screws and Allen wrench. 1.2.6 Adjusting the Plate Holder The Shaking Peltier Device has four adjustable corner guides for holding labware snugly in the device (Figure 1-8). The four corner guides need to be adjusted for the specific labware type used on the Shaking Peltier Device to ensure that labware is firmly held in place while shaking. Adjustable labware guides Figure 1-8. Adjusting the corner guides of the Shaking Peltier Device plate holder To adjust the corner guides for labware: 1. Place a piece of labware of the desired type on the Shaking Peltier Device. Note: Make sure the appropriate adapter plate is installed before placing labware on the Shaking Peltier Device. 2. Using a 1.5 mm Allen wrench, adjust the corner guide screws to control how tightly labware is held in place. The microplate should fit snugly in the position but still move freely in and out of the plate holder. Beckman Coulter, Inc.

Shaking Peltier Device 11 1.3 Setting Up the Shaking Peltier Device in Biomek Software After physically installing the Shaking Peltier Device on the Biomek 3000 Laboratory Automation Workstation, it is must be set up to use in Biomek Software. Setting up the Shaking Peltier Device in Biomek Software includes: Installing Software for the Shaking Peltier Device (Section 1.3.1) Adding the Shaking Peltier Device to the Deck in the Deck Editor (Section 1.3.2) 1.3.1 Installing Software for the Shaking Peltier Device A software module needs to be installed to enable use of the Shaking Peltier Device in Biomek Software. The software module install includes: ALP definitions to add the Shaking Peltier Device to the deck (refer to Section 1.3.2, Adding the Shaking Peltier Device to the Deck in the Deck Editor). steps to control the Shaking Peltier ALP in a Biomek method (refer to Section 1.6, Using the Shaking Peltier Device in a Method). device controls to control the Shaking Peltier Device outside a method using the Device Editor (refer to Section 1.7, Manually Controlling the Shaking Peltier Device). To install the Shaking Peltier Device software: 1. Close Biomek Software if it is open. Note: The installation only installs the Shaking Peltier Device to the active instrument file. Make sure the desired instrument is active before closing Biomek Software. To install the Shaking Peltier Device for multiple instrument files, run the install once for each instrument, changing the active instrument file in Biomek Software between each run. 2. Insert the Shaking Peltier Device CD in the CD-ROM drive of the Biomek Controller PC. 3. In Windows Explorer, browse to and select Shaking Peltier Module Install.exe. Shaking Peltier Device Integration Manual

12 Shaking Peltier Device 4. Double-click Shaking Peltier Module Install.exe to launch the install program. Shaking Peltier SILAS Module appears (Figure 1-9). Figure 1-9. Shaking Peltier SILAS Module install 5. In Module Name, enter a name for the device. This name is used when associating the device with a position in the Deck Editor (refer to Section 1.3.2, Adding the Shaking Peltier Device to the Deck in the Deck Editor). 6. In Adapter Plate Type, select the type of adapter plate that is installed on the Shaking Peltier Device. Flat 96-well Thermocycler 384-well Thermocycler Note: The install only installs the necessary information for the selected adapter plate type. The first time a new adapter plate type is used, the install needs to be run again and the new Adapter Plate Type selected. 7. Select Simulation only if using the software on a computer that is not attached to an instrument. This allows methods to be created without the controller attempting to communicate with the device. 8. Choose Next to install the Shaking Peltier SILAS Module. The installation begins. Beckman Coulter, Inc.

Shaking Peltier Device 13 9. When the installation completes, Figure 1-10 appears. Figure 1-10. Installation of Shaking Peltier SILAS Module complete 10. Choose Finish to close the installation program. The Shaking Peltier SILAS Module has been installed successfully. Shaking Peltier Device Integration Manual

14 Shaking Peltier Device 1.3.2 Adding the Shaking Peltier Device to the Deck in the Deck Editor After physically installing the Shaking Peltier Device on the deck of the Biomek 3000 instrument, it must be added to the deck in the Deck Editor. To add the Shaking Peltier Device to the Deck Editor: 1. Launch Biomek Software, if necessary. 2. From the Instrument menu, choose Deck Editor. Deck Editor appears showing the representation of the current deck. 3. From the ALPs List on the left, select the appropriate Shaking Peltier Device for the adapter plate installed: ShakingPeltier_Flat select this device for the Shaking Peltier Device without an adapter plate. ShakingPeltier_96 select this device for the Shaking Peltier Device with a 96-well adapter plate. ShakingPeltier_384 select this device for the Shaking Peltier Device with a 384-well adapter plate. 4. Click and drag the selected ALP to the desired location. The positions that support the Shaking Peltier Device are indicated by a blue outline. There are two deck positions on the left side of the deck that support that Shaking Peltier Device. 5. Double-click the Shaking Peltier position. The position name varies depending on the adapter plate and will be either SPelt_1, SPelt96_1, or SPelt384_1. Position Properties appears (Figure 1-11). Figure 1-11. Position Properties for Shaking Peltier Device Beckman Coulter, Inc.

Shaking Peltier Device 15 6. Choose More to expand Position Properties (Figure 1-12). Figure 1-12. Position Properties for Shaking Peltier Device expanded 7. In Device, select the ShakingPeltier device. 8. Choose Manual Teach to frame the position (refer to Section 1.4, Framing Instructions). 9. Choose OK to close Position Properties. 10. Choose Save to save the deck and close the Deck Editor. Note: Choosing Cancel loses all changes, including framing information, since the Deck Editor was opened. Shaking Peltier Device Integration Manual

16 Shaking Peltier Device 1.4 Framing Instructions The Shaking Peltier Device must be framed before using it in a method. Framing allows the Biomek 3000 to accurately move labware to and from the Shaking Peltier Device and pipette to and from microplates positioned on the Shaking Peltier Device. Framing the Shaking Peltier Device is performed using the Biomek 3000 framing adapter to visually align the head assembly to the wells of a microplate. Frame the Shaking Peltier Device to the center of well A1 using manual framing with tips. The tip type and labware type that will most commonly be used on the Shaking Peltier Device should be used while framing for best performance. Note: Pipetting on the Shaking Peltier Device is only supported in 96-well and less dense labware. If using the 384-well plate adapter, use a P20 tip for framing. Note: The Shaking Peltier Device must be reframed each time the adapter plate is changed. Framing the Shaking Peltier Device includes: Attaching the Manual Framing Tool (Section 1.4.1). Manually Framing the Shaking Peltier Position (Section 1.4.2). Beckman Coulter, Inc.

Shaking Peltier Device 17 1.4.1 Attaching the Manual Framing Tool Manually framing the Shaking Peltier Device requires the framing tool to be installed on the head assembly. The framing tool is a tool with a single probe used to precisely teach the Biomek Software the locations of all labware positioners on the deck. To attach the manual framing tool to the head assembly: 1. Push a tip onto the probe on the framing tool (Figure 1-13). Note: Make sure the tip is fully loaded onto the framing tool and is not bent or damaged even slightly. Plunger Tool release button Framing tool Tip Figure 1-13. Installing the framing tool on the head assembly 2. Press the tool release button on the head assembly and push the framing tool onto the plunger (Figure 1-13). Note: Make sure that the arrow marked FRONT on the framing tool is pointing towards the front of the Biomek 3000 deck. 3. Release the button when the framing tool is properly seated. Shaking Peltier Device Integration Manual

18 Shaking Peltier Device 1.4.2 Manually Framing the Shaking Peltier Position Manual Teach is a wizard-type interface that is used to manually frame deck positions on the Biomek 3000 workstation. Using Manual Teach helps to ensure that the tips can access the wells without causing any damage to the tips, tools, or labware positioners. The Shaking Peltier Device is framed to a microplate positioned on the device. The framing tool tip must be aligned to the center of well A1. To frame using Manual Teach: 1. Choose Start>Programs>Beckman Coulter>Biomek to open the Biomek Software. 2. From the Instrument menu, choose Deck Editor. Deck Editor appears (Figure 1-14). Figure 1-14. Deck Editor for Biomek 3000 workstation Beckman Coulter, Inc.

Shaking Peltier Device 19 3. Open Position Properties for the desired Shaking Peltier Device by doubleclicking on the deck position. Position Properties appears (Figure 1-15). Figure 1-15. Position Properties for a Shaking Peltier Device 4. In Name, verify that the position is assigned a unique name. 5. Choose Manual Teach. Biomek 3000 Manual Teaching opens with a Warning (Figure 1-16). Note: On the left side of Manual Teaching, a list of steps required to complete the teaching process is displayed. As the steps of Manual Teaching are accessed, the steps are highlighted on the left. Figure 1-16. Biomek 3000 Manual Teaching (Warning) Shaking Peltier Device Integration Manual

20 Shaking Peltier Device 6. Address the Warning appropriately and choose Next to continue. Biomek 3000 Manual Teaching displays Adapter. No framing adapter is required to frame the Shaking Peltier Device. Figure 1-17. Manual Teaching if framing adapter is not required. 7. Choose Next to continue to the next screen. Biomek 3000 Manual Teaching displays Load Tool. Figure 1-18. Loading tool during manual teach 8. If not already installed, install the framing tool on the Biomek 3000 head assembly (refer to Section 1.4.1, Attaching the Manual Framing Tool). Beckman Coulter, Inc.

Shaking Peltier Device 21 9. Manually load a tip onto the framing tool, if a tip is not already loaded. Any tip type defined in the Tip Type Editor may be used; it is recommended that the type of tip that will be used most frequently for liquid handling operations at the Shaking Peltier Device is used for framing. Note: If an alignment tip is bent or damaged even slightly, replace the tip before framing. 10. In Please manually load a tip of type, select the type of tip that is currently loaded on the framing tool (from step 9). This selection must match the tip type physically loaded on the framing tool. 11. Choose Next to continue to the next screen. Biomek 3000 Manual Teaching displays Select Target (Figure 1-19). Figure 1-19. Selecting target to manual teach position 12. Select Line tip up against a... plate and select a plate type to use a piece of labware to frame. The plate type selected should be the plate type that will be used most frequently on the Shaking Peltier Device. 13. Place a microplate of the selected type on the Shaking Peltier Device. Push it so that the microplate is flush with the back left corner of the Shaking Peltier Device. Shaking Peltier Device Integration Manual

22 Shaking Peltier Device 14. Choose Next to continue to the next screen. Biomek 3000 Manual Teaching displays Teach X,Y (Figure 1-20). 15. Select Well Center to align the tips to the center of the wells. Figure 1-20. Framing to the center of a well 16. To align the tips in the X- and Y-axes with the microplate placed on the labware positioner, lower the framing tool tip in the Z-axis until it is approximately 1 mm above the top of the microplate. Note: Since tip height is set in the next step in the Biomek 3000 Manual Teaching process, it is safe to move the head assembly to any height to make aligning the tips with the target position easier. 17. Visually verify the physical position of the tips in relation to the microplate well. 18. Adjust the position of the tip to align it with the microplate well by either: Using the Graphic Alignment Tool (Section 1.4.2.1). Using the Delta Value and Directional Buttons (Section 1.4.2.2). 19. Frame the Z-axis height to complete the framing process (refer to Section 1.4.2.3, Framing the Z-Axis). Beckman Coulter, Inc.

Shaking Peltier Device 23 1.4.2.1 Using the Graphic Alignment Tool The graphic alignment tool (Figure 1-21) is used to instruct the Biomek Software of the current position of the framing tool tip to the center of well A1 on the microplate. The Biomek Software uses the information it is given to move the head assembly so the framing tool tip is directly above the center of the well. Graphic alignment tool The graphic alignment tool is a visual representation of the tip (small circle) and the target well. The small circle is moved until it represents the tip s current physical location in relation to the center of the well. Figure 1-21. Manually teaching the X- and Y-axes using the graphic alignment tool To use the graphic alignment tool: 1. Drag the center (small) circle until it represents the tip s physical position in relation to the center of well A1 on the microplate. Note: The small circle represents the tip on the framing tool. The objective is to provide the software with a representation of the tip s position in relation to the center of well A1 on the microplate. The software uses this graphical representation to know approximately how far in any direction the tips must move. 2. Select Go. The pod moves in accordance with the position of the small circle in relation to the large circle. Note: When the move is completed, the small circle resets itself to the center of the large circle. The values displayed in Total Moved from Start (cm) changes each time steps 1 and 2 are completed. If desired, the values in Total Moved from Start (cm) can be reset to zero by selecting Reset. Shaking Peltier Device Integration Manual

24 Shaking Peltier Device 3. Visually verify the position of the tip on the framing tool in relation to the center of well A1 on the microplate. If the tips are still not accurately positioned above the center of well A1 on the microplate, repeat steps 1 and 2 until they are accurately positioned above the center of well A1 on the microplate. Note: The tip may also be aligned with the position using the delta value and directional buttons (refer to Section 1.4.2.2, Using the Delta Value and Directional Buttons). 4. Once the tip is aligned with the center of well A1 on the microplate, choose Next to continue. Biomek 3000 Manual Teaching displays Teach Z (refer to Section 1.4.2.3, Framing the Z-Axis). 1.4.2.2 Using the Delta Value and Directional Buttons The tip can be positioned manually using the delta values and directional buttons to align it with the target position on the labware positioner or microplate. Pressing one of the directional buttons moves the head assembly that direction by the distance specified in Delta. Position the tip above the target position on the microplate. Delta value The magnitude of change applied to the tips each time a directional button is selected. Directional buttons The directional buttons move the head assembly by the amount shown in Delta with each press of a button. Figure 1-22. Manually teaching the X- and Y-axes using delta values and directional buttons Beckman Coulter, Inc.

Shaking Peltier Device 25 To use the delta value and directional buttons to position the tip: 1. In Delta, select the magnitude of change applied to the tips each time a directional button is selected (Figure 1-22). Note: The default Delta value is 0.05 cm. This is the smallest movement that can be made in the X and Y axes. If the tips are a considerable distance from the desired location, increase the distance traveled by increasing the Delta value (maximum setting is 1.0 cm). 2. Select the directional button representing the motion required to physically move the tip into position over the target position on the microplate (Figure 1-22). Note: Each time a directional button is selected, the pod and tips move the distance specified in Delta in the indicated direction. Note: The tips can be physically positioned over the wells of a microplate using: the directional buttons in Manual Teach. the directional keys on the keyboard. the directional keys on the numeric keypad. The directional buttons displayed in Manual Teach parallel the keys on the numeric keypad. More specifically, Fwd. correlates to the 1 on the numeric keypad, while Down is found on the 2, Left is found on the 4, Right on 6, Up on 8, and Back on 9. 3. Visually verify the position of the tip on the framing tool in relation to the target position on the microplate. If the tip is still not accurately positioned above the target position on the microplate, repeat steps 1 and 2 until they are accurately positioned above the target position on the microplate. Note: The tip may also be aligned with the position using the graphic alignment tool (refer to Section 1.4.2.1, Using the Graphic Alignment Tool). 4. Once the tip is aligned with the target position on the microplate, choose Next to continue. Biomek 3000 Manual Teaching displays Teach Z (refer to Section 1.4.2.3, Framing the Z-Axis). Shaking Peltier Device Integration Manual

26 Shaking Peltier Device 1.4.2.3 Framing the Z-Axis After the X- and Y-axes are framed, the Z-axis must be framed to ensure aspirate and dispense operations are performed at the desired height. The final screen in Biomek 3000 Manual Teaching is for framing the Z-axis (Figure 1-23). Figure 1-23. Manually teaching the Z-axis 1. In Delta, select the magnitude of change applied to the framing tool tip each time a directional button is selected (Figure 1-23). Note: The default Delta value is 0.05 cm. If the tip is a considerable distance above the position, increase the distance traveled by increasing the Delta value (maximum setting is 1.0 cm). If the tip is almost to the desired location, reduce the Delta value (minimum setting is 0.005 cm). 2. Select the directional button representing the motion required to physically move the tip down until the bottom of the tip is at the same height as the top of the well. One way to determine that the tip is at the right height is to put a Post- It note over the well and lower the tip until it just touches the Post-It note. Note: Each time a directional button is selected, the pod and tips move the distance specified in Delta in the indicated direction. Note: The tips can be physically positioned over the wells of a microplate using: the directional buttons in Manual Teach. the directional keys on the keyboard. the directional keys on the numeric keypad. The directional buttons displayed in Manual Teach parallel the keys on the numeric keypad. More specifically, Fwd. correlates to the 1 on the numeric keypad, while Down is found on the 2, Left is found on the 4, Right on 6, Up on 8, and Back on 9. Beckman Coulter, Inc.

Shaking Peltier Device 27 3. Once the framing tool tip is at the same height as the top of the well, select Finish. The pod moves up to its maximum height in the Z-axis, Manual Teaching closes, and Position Properties appears (Figure 1-15). 4. Choose OK to save the framing information and close Position Properties. 5. Repeat the procedure to frame additional deck positions using manual teach. 6. Choose Save to save framing information for all positions and close the Deck Editor (Figure 1-14). Note: Choosing Cancel loses all changes to the deck, including framing information, since the Deck Editor was opened. 7. After all positions have been framed, remove the framing tool by pressing the tool release button and carefully pulling the framing tool off the plunger. Shaking Peltier Device Integration Manual

28 Shaking Peltier Device 1.5 Calibrating the Peltier Device Temperature For best heating and cooling results, the Shaking Peltier Device should be calibrated to the target temperature at which the Shaking Peltier Device is operated. A calibration offset can be specified in the Watlow Controller to adjust for the difference between the temperature displayed on the Watlow Controller and the actual temperature at the point of interest. The calibration compares the display temperature on the front of the Watlow Controller to the actual temperature measured for the target using a calibrated thermometer or thermocouple. The target is the desired location for which the temperature is controlled. For example, if using the Shaking Peltier Device to control the temperature of a liquid in a reservoir, the target could be the center of a reservoir with the desired liquid placed on the Peltier Device. Note: For most accurate results, a new offset should be calculated when changing the desired temperature, the adapter plate, or the labware or liquid type used on the device. 1. Set up the Shaking Peltier Device with the target labware and liquid type. 2. Adjust the Peltier temperature to the desired temperature. Record this value as the displayed temperature. 3. Allow the Peltier Device to reach a steady state at the desired temperature. 4. Measure the temperature of the target using a calibrated thermometer or thermocouple. Record this value as the measured temperature. 5. Determine the calibration offset value be subtracting the displayed temperature recorded in step 2 from the measured temperature recorded in step 4. For example, if the Peltier Device was set to 15ºC but the temperature was measured to be 13.7ºC, then the calibration value is 13.7ºC - 15ºC = -1.3ºC. 6. On the front of the Watlow Controller for the Shaking Peltier Device, push and hold both arrow buttons. 7. Use the arrow keys to scroll until the User option appears. 8. Press the green button to enter the User menu. 9. Use the arrow keys to scroll to CAL1. 10. Enter the calibration offset value CAL determined in step 5 above. 11. Press the (infinity symbol) button to set the calibration offset. Beckman Coulter, Inc.

Shaking Peltier Device 29 1.6 Using the Shaking Peltier Device in a Method Using the Shaking Peltier Device in a Biomek method requires using the Peltier Step step that is displayed on the Peltier step palette (Figure 1-24). The Move Labware step from the Basic Step Palette is used to move labware to and from the Shaking Peltier Device (refer to the Biomek Software User s Manual, Section 16.4, Move Labware Step). Note: Make sure that the Shaking Peltier Device is associated with the Shaking Peltier position in the Deck Editor (refer to Section 1.3.2, Adding the Shaking Peltier Device to the Deck in the Deck Editor). Peltier step palette Peltier Move Step The Peltier Move step is only used with the Static Peltier Device. Use the Move Labware step from the Basic step palette with the Shaking Peltier Device. Figure 1-24. Peltier step palette displayed Shaking Peltier Device Integration Manual

30 Shaking Peltier Device 1.6.1 Using the Peltier Step in a Biomek Method The Peltier Step is used to allow labware to be incubated at a specified temperature and time, with or without shaking, on the Shaking Peltier Device in a Biomek method. Figure 1-25. Peltier Step configuration 1. Drag and drop Peltier Step into the Method View (Figure 1-25). 2. From Using the device at position, choose the Peltier ALP on which the labware is positioned. 3. Select the command to execute: Initialize initiate communication between the Shaking Peltier Device and the Biomek Controller PC. Initialize has no further configuration. Incubate hold labware at a specified temperature for a specified duration, with or without shaking. Start Shaking begin shaking a microplate on the Shaking Peltier Device. Stop Shaking stop shaking a microplate that is shaking on the Shaking Peltier Device. Stop Shaking has no further configuration. 4. For Incubate, in for, enter the time in seconds to incubate the labware on the Shaking Peltier Device. Note: The incubation timer starts when the step is executed, even if it is not at the specified temperature. 5. For Incubate, to set a specified temperature, ensure Set Temperature to is checked and enter a temperature in degrees Celsius (4.0 to 50.0). Beckman Coulter, Inc.

Shaking Peltier Device 31 6. For Incubate, select the Shake checkbox to shake the microplate during incubation. 7. For Incubate or Start Shaking, in Shake at, enter the rate of shaking in rotations per minute (RPM). 8. For Incubate, select Continue Shaking after incubation until device receives Open command to continue shaking the microplate after the incubation is complete until the position is accessed for gripping or pipetting. 9. For Incubate or Start Shaking, select the desired shake style option: Use one shake style shake the microplate using one shake pattern. Alternate between two shake styles shake the microplate using a repeating pattern that alternates between two shake patterns. 10. In Shake using or Start shaking using, select the first shake pattern. If using only one shake style, configuration is complete. 11. If alternating between two shake styles, in for, enter the length of time to shake using the first shake style before changing to the second shake style. 12. In Next shake using, select the second shake pattern and enter the length of time to shake using the second shake style before changing back to the first shake style. This shake sequece repeats until the incubation is complete, the position is accessed, or a Stop Shaking command is sent. Shaking Peltier Device Integration Manual

32 Shaking Peltier Device 1.7 Manually Controlling the Shaking Peltier Device Device Editor allows users to manually control Peltier ALP actions, such as incubating, outside of methods. 1.7.1 Configuring Options for the Peltier ALP Configuration Options for the Shaking Peltier Device allow for the communications port to which the Shaking Peltier Device is connected to be configured. To set the configuration options for the Shaking Peltier Device: 1. From the Instrument menu, choose Device Editor. Device Editor appears (Figure 1-26). Figure 1-26. Selecting the Shaking Peltier Device in the Device Editor 2. In Device, choose ShakingPeltier. 3. Choose Configuration Options. ShakingPeltier Options appears (Figure 1-27). Figure 1-27. Peltier ALP configuration options 4. In Communications Port, select the comm port on the Biomek Controller PC to which the Shaking Peltier Device is connected. 5. Choose OK to save the changes and close ShakingPeltier Options, or Cancel to close ShakingPeltier Options without saving changes. Beckman Coulter, Inc.

Shaking Peltier Device 33 1.7.2 Performing Actions in the Device Editor To manually control a Peltier action outside a method: 1. From the Instrument menu, choose Device Editor. Device Editor appears. 2. In Device, choose ShakingPeltier. 3. Choose Action Commands. ShakingPeltier appears (Figure 1-28). Figure 1-28. ShakingPeltier Device Action Commands 4. In Action, choose the desired function: Initialize intializes communications between the Biomek instrument and the Shaking Peltier Device. There is no further configuration required; go to step 14. Incubate sets the temperature and incubates a plate for a specified duration. Start Shaking begin shaking a microplate on the Shaking Peltier Device. Stop Shaking stop shaking a microplate that is shaking on the Shaking Peltier Device. Stop Shaking has no further configuration; go to step 14. Shaking Peltier Device Integration Manual