System and Components Installation Manual

Similar documents
WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Carbon Monoxide Safety Information

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

ADT Carbon Monoxide Alarm

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL Models RV & RV ABOUT THIS ALARM

Red Alarm Indicator Light

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

Manhattan Fire Protection District

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

CPVan Home Alarm Starter Kit

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Models & ABOUT THIS ALARM

Travis County Emergency Services District #1 Standard Operating Guidelines

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

Protecting Children from Carbon Monoxide Poisoning

LL6070 Carbon Monoxide Monitor

Digiplex LED Keypads User s Manual

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

Carbon Monoxide Room Alarm Installation and User Guide Part No:

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

RV Safety Alarms Education Test

Carbon Monoxide Alarm User s Manual

3 Macurco Carbon Monoxide Detector CM-16A

Macurco CM-E1 Carbon Monoxide Detector

CARBON MONOXIDE DETECTOR, i4h-co-m330

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

GS100M Gas Detection Controller

CA6150 Carbon Monoxide Alarm

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Carbon Monoxide Alarm Owner s Manual

Model Carbon Monoxide (CO) Alarm Response Policy

ADC-T2000. Smart Thermostat v1.5

Frequently Asked Carbon Monoxide Questions

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

carbon monoxide Preventing carbon monoxide poisoning in your home

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

OWNER S MANUAL for Models:

EWF1 EWF1CO WIRELESS SMOKE DETECTOR WIRELESS SMOKE & CO DETECTOR

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

User guide. for smoke detector

User s Information Guide R2A

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

TESTED TO UL2034, UL1484 AND CSA 6.19

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

C0-210 Carbon Monoxide Probe

Owner s Manual TABLE OF CONTENTS

USING DEVICE COMMANDS

DYGIZONE GJD910 Lighting Controller & Enunciator

Condominium Security Management System

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Carbon Monoxide Safety

PROGRAMMING PROCEDURES (Table 3)

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

can quickly rise to dangerous levels

Installation and User Guide

DS7400Xi (version 3+) Security System User s Guide

BX444-Mc Gas Detector

Total Connect Box. User manual

Watchguard WGAP864 User Manual

about your house Carbon Monoxide

OWNER S MANUAL for Models:

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Wireless Keypads LKP(E)S8M Series

USER MANUAL & MAINTENANCE GUIDE OG OO

Using Your. Security System With LED Keypad S5030, S5031, S5032

WIRELESS CARBON MONOXIDE ALARM

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

CAUTION FOR YOUR SAFETY

Pella Insynctive Product Guide

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

COMPUTHERM. CO1400 Carbon Monoxide Alarm OPERATING INSTRUCTIONS

System-Connected Carbon Monoxide Detectors

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Carbon Monoxide Alarm. with 10 Year Permanent Power Sealed Battery

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

NX-148 LCD CODE PAD TABLE OF CONTENTS

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

The Village of Franklin Gas Safety Pamphlet

Carbon Monoxide Detection in Buildings Frequently Asked Questions

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

IMPORTANT SAFETY INFORMATION:

SPECTRA 1727 USER S GUIDE

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

DS7080i Version 2+ Security System User s Guide An instruction guide For your alarm system when used with a DS7447, DS7443S or DS7445 keypad

Technical Manuals Online! - K4855V1 3/00 FA560 3 STAY B 1 OFF 2 AWAY 6 C D 5 TEST 9 CHIME # 8 CODE I I I I I I READY ARMED MAX

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

DIRECTIVE NO: D-B

NetworX NX-8V2. LED Keypad User Manual

Transcription:

1/2017 System and Components Installation Manual 1. We recommend our safety systems be installed by certified and or license technician according to all NEC, Building and or Local Code Requirements. 2. Before securing any components, map out the locations for where each component will be installed first and make sure electric is available. 2. Verify power is available at each location for the components 3. Verify with the customer s component locations are acceptable 4. Temporary position all components at their ideal location until end-to-end testing is verified. 5. Call if you have any questions Flowtech Safety Systems Contacts: Keith Bell, Vice President of Distribution & Technical Support, 845 621-7233 keith@flowtechsafetysystems.com Dan Sheridan, Flowtech Safety Systems President, 845 490 0111 dan@flowtechsafetysystems.com John Healy, Vice President of Sales & Operations, 845 621-7233, D: 516 799-8775, jhealy.flowtech@gmail.com www.flowtechsafetysystems.com www.facebook.com/flowtechsafetysystems Twitter: Flowtech@flowtechsafety 1

System Overview The Flowtech Safety Systems detects dangerous levels of Gas or LPG and CO. Once a leak is detected a signal is sent to the control panel which activates the auto shut-off ball valve. Cutting off the danger from the source which saves lives and prevents illnesses for CO. 2

Wireless Control Panel Monitor 1. Panel provides power to the shut-off valve, uses < 2W 2. Monitors and Receives wireless signals from the Detectors 3. Range of 200 Meters or 656 Feet 4. Operates using the 433 Frequency band 5. Each system operates on a unique code to prevent cross communications with adjoining properties 6. Operates up to 40 Detectors 7. CE Approved Motorized Ball Valve Shut-Off 1. Closing Time: 3-4 Seconds 2. Operating Torque 30-60 Kg/cm, <1.2W 3. Can be install in-less than hour on Gas or Oil Lines within a property 4. Installed by certified and or license installer, piped into the internal property gas line after the Gas Meter. Valve is either ¾ or 1 ¼ fitting 5. Motor can be installed separately at a property s relay panel to shut-off the Gas Main in commercial properties 6. Valve is CSA and CE approved 3

Installation Guide: Motorized Shut-Off Valve & location 1. Installation should take less than hour 2. Make sure the gas line is turned-off at the meter valve 3. Determine the best internal location to safely insert the valve in the premise gas main and to access a power source 4. Valve should be placed as close as possible after the meter and before the 1 st gas appliance within the premise 5. Verify after Valve is installed there are no gas leaks at the valve installation points 6. Ensure the Manual Reset Button is accessible 7. Install the Control Panel Monitor Installation Guide: Control Panel Monitor & Location 1. Panel powers the shut-off valve and receives the wireless signals from the Detectors. 2. Recommend Panel be placed in an area/room near the Shut-Off Valve a. Ensure the Panel can be connected to an electrical power source b. Ensure Panel leads can connect to the Shut-over Valve 3. Before installing Monitor, verify wireless link to detectors can be received to ensure system operates correctly and is not interfered by any other wireless system in the home. 4. Connect electrical power leads to their power source, comes with approximately 48 inches of cabling from panel 5. Once components are installed, verify system operates properly 6. DO NOT place outside, behind furniture, curtains, blinds, etc. TEST the Valve and System 1. Press the Emergency Shutoff Button on the controller Open/Reset to verify the valve and button works by pushing to Close and then to Open 2. Or pull white manual button up, turn to desire position, push button down lock in position 3. Connect power supply lead from the Control Panel to Valve, maximum 60 using 18 AWG 4. Installation Check: Power on the Control Panel and Detectors. The system will run a sequence check: a. To the Detectors and Control Panel to check wireless connectivity b. System will verify Power to the Shut-over Valve and that all reset functions are working correctly Position Indicator, valve open or closed 4

Control Panel Monitor Setup: Control Panel Monitor 1. When power is supplied to monitor and detectors, Power lights turns Green 2. Gas Detectors the green LED light begins to flash, syncing with control panel monitor 3. The Control Panel is design to pair with the Detectors by receiving a unique code 4. When all detectors are stabilized, the green LED power lights remains solid 5. Press black button on top of the Control Panel for 1 second, the Red Code Light with turn on and stay lit for 30 seconds, sending an unique code to detectors within range to pair the components 6. Pair each Detector, press the test button for 2 seconds on each Detectors during the 30 second Control Panel syncing period 7. When the Control Panel beep 3 times, pairing is compete with the Detector. 8. Repeat the process until all Detectors are paired or if you add additional Detectors 9. Secure the Detectors in place v To clear all pairing press the button on top of the Control Panel for 40 seconds, red code light will light and go off Final System Checks & Notes 1. The system is designed to stop attempts to re-open the Shut-Off Device during an alarm. The device will automatically re-close if you try to reopen the valve 2. IMPORTANT Ensure that the gas supply is open as your system check is now completed. 3. The System provides Visual and Audible Alarms when dangerous Gas or CO levels are reached 4. The System closes off the gas supply to prevent further build up of these gases 5. It is vital that you protect yourself and other occupants by taking the following steps if an alarm is activated: i. Immediately leave premise and move to a fresh air location ii. Call 911 iii. If anyone is experiencing symptoms of CO poisoning: headaches, dizziness, vomiting, call for Medical help iv. Do not re-enter the premises until the location has been checked by an Emergency 1 st Responder v. Call your service provider or a qualified technician and have the problem fixed before restarting appliances. 5

Installation Guide: Gas Detectors - Sensors Locations 1. Recommend Detectors placed in every room with a gas fuel burning appliance (Burner, Stove, Dryer, etc.) 2. Detectors come supplied with a back-plate and two methods of fixing using either a single screw or two screw with approximately 48 inches of cabling 3. GAS Detector: Recommend placing Detector approximately 12 below ceiling level, at least 60 off the floor & within 13 to 16 away from a Gas Burning Appliance. Ü Detector can be placed on ceiling next to light and power source 4. LPG Detectors: must be installed at a low level due to the density of the gas. 5. Before installing detector, verify wireless link to monitor can be received to ensure system operates correctly 6. Ensure Detector location can be connect to a required power supply. v Detectors can be power by plugging into the nearest outlet or hard wired 7. If only one Gas detector is placed, install near the gas furnace area. Installation Guide: CO Detector - Sensors Locations: (Optional but recommended) 1. Recommend CO Detectors be placed in every room with a fuel burning appliance. 2. Detectors come supplied with a back plate and two methods of fixing using either a single screw or two screw with approximately 48 inches of cabling 3. Place CO Detector approximately: 12 below ceiling level, 60 off the floor & within 13 to 16 away from a Gas Burning Appliance. 4. Before installing CO detector, verify wireless link to monitor can be received, ensure system operates correctly 5. Ensure Detector location can be connect to a required power supply. v Detectors can be power by plugging into the nearest outlet or hard wired, fished behind wall/ceiling to nearest power outlet or use a surface mounted wiring method. 6. If only one CO detector position near bedroom area so the alarm can be heard DO NOT place GAS or CO Detectors: a) Outside, drafty, damp, humid or dusty areas or behind furniture, curtains, blinds, etc. b) Or Directly above any gas appliances v Product warranty is not covered if Detector is placed in the above situation All Detectors should be replaced every 5 years. 6