Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

Similar documents
CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS


2012 INTERNATIONAL FUEL GAS CODE VENTS

Inspection Checklist Mechanical Final

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

SECTION DUCTWORK

Over 40 years of Dependable Service

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

NFPA 80 Overview January 21, 2016

SECTION (15820) - AIR DUCT ACCESSORIES

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Material Design for Central Chutes

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

GASEOUS HYDROGEN SYSTEMS

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

SEPARATED COMBUSTION WARNING

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

CHAPTER 7 ALTERATIONS LEVEL

IMC Significant Changes Summary Tier I

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SEPARATED COMBUSTION. General WARNING

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

SEMICONDUCTOR FABRICATION FACILITIES

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

FIRE SAFETY INSPECTION REPORT

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2006 EDITION

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Developing a Healthcare Facility Fire Door Inspection Program

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Agency for Health Care Administration

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

SEMICONDUCTOR FABRICATION FACILITIES

Osceola County Department of Fire Rescue and Emergency Medical Services

CHAPTER 5: EXHAUST SYSTEMS

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Life Safety Dampers Selection and Application Manual

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Worldwide Contacts.

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights

SEMICONDUCTOR FABRICATION FACILITIES

ASX7-5-IOM-3 J

DUCT SYSTEMS CHAPTER 6

FIRE SAFETY INSPECTION REPORT

Installation and Maintenance Instructions

SECTION (15833) - HVAC POWER VENTILATORS

SPECIFIC APPLIANCES CHAPTER 6

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Fire and Smoke Door Inspections Qualified Training 02/03/17

Module 7. Control of Smoke & Highlights of Code Requirements

INSTALLATION INSTRUCTIONS

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Agency for Health Care Administration

PERFORMANCE COMPLIANCE METHODS

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

WHITE PLAINS SMOKE CONTROL CODE PART 1. GENERAL REQUIREMENTS

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION

For the Florida Building Commission And the Fire Code Advisory Council

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

FIRE SAFETY INSPECTION REPORT

INSTALLATION INSTRUCTIONS

Agency for Health Care Administration

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Inspection Checklist Mechanical Rough in

SPECIFIC APPLIANCES CHAPTER 6

Agency for Health Care Administration

FIRE SAFETY INSPECTION REPORT

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

INSTALLATION AND SERVICE MANUAL

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Revitalize Building Mechanical Systems (4619)

Technical and Dimensional Data. Saf-T Vent SC Plus

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

Installation Instructions

CONTENTS AUTOMATIC TRANSFER SWITCHES

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

SPECIFIC APPLIANCES CHAPTER 6

DUCT SYSTEMS CHAPTER 6

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Safety Cabinets STORAGE. KEWAUNEE encouraging new discovery FLAMMABLE & CORROSIVE

FIRE SAFETY INSPECTION REPORT

SEMICONDUCTOR FABRICATION FACILITIES

FIRE PROTECTION SYSTEMS

Transcription:

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form PART 1 GRAVITY CHUTES CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LIMITED ACCESS OFFSETS DIMENSIONS VENTING CONSTRUCTION 1. As a minimum, are chute intake doors installed at alternate floors? NFPA 82: 5.1.2 1. Are linen gravity chutes secured to provide only limited access to authorized personnel? NFPA 82: 5.2.1 1. Are gravity metal chute offsets a maximum of 15 degrees? 2. Are offsets limited to a maximum of one for every two floors? 3. Are access doors at least 1.2 m (4 ft) above an offset? 4. Is the offset between the highest intake door and the chute termination a maximum of 45 degrees? NFPA 82: 5.2.2.2 1. Are chutes a minimum of 571 mm (22½ in.) 571 mm (22½ in.) or 610 mm (24 in.) in diameter? NFPA 82: 5.2.2.3 1. Are vents extended at least 0.92 m (3 ft) above unprotected or combustible construction (Type II (000), Type III, Type IV or Type V)? 2. Is the chute vent open to the atmosphere with the same cross sectional areas as the chute? 3. Is the offset between the highest intake door and the top of the vent a maximum of 45 degrees? NFPA 82: 5.2.2.4 1. Are metal chutes made of stainless steel, galvanized steel or aluminum-coated steel with no screws, rivets, or other projections on the interior surface? 2. Are metal chutes at least 16 U.S. gauge? NFPA 82: 5.2.2.7 1. Are vertical chutes serving multiple floors enclosed in fire-rated construction? a. Is rating 1-hr with 1-hr opening protection for 3 stories or less? b. Is rating 2-hr with 1½-hr opening protection for 4 stories or more? NFPA 82: 5.2.3.1 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 1 of 7) Form A-36 Inspection Form to Accompany Chapter 44 100

DISCHARGE DOORS INTAKE DOORS SEPARATION CLEARANCE GE ROOM 1. Is the bottom of waste chutes protected by automatic or self-closing doors constructed to meet the required fire rating? (UL label and latch are not required.) 2. Is the bottom of linen chutes protected by a UL listed, automatic or self-closing fire door to meet the required fire rating? 3. Are chute discharge doors held open to automatically close (fusible link is acceptable method)? NFPA 82: 5.2.3.2 1. Are all intake doors UL listed, automatic or self-closing fire doors providing the required fire rating? 2. Is the area of the intake door for a general access chute limited to: a. 1/3 the cross-sectional area of a square chute or b. 44 percent of the area of a round chute? 3. Do limited access chutes require a key to access the intake door? 4. Is the area of intake doors to limited access chutes limited as follows: a. Waste chute 2/3 the cross-sectional area of the chute b. Linen chute the cross-sectional area of the chute? NFPA 82: 5.2.3.3 CHUTE SERVICE OPENING ROOMS 1. Are service openings located within a room or compartment separated from other parts of the building? NFPA 82: 5.2.5 1. Is the service opening room enclosed in fire-rated construction as follows: a. Fire-rating equal to the rating of the chute, or b. Fire-rating at least 1-hr with automatic sprinkler protection? NFPA 82: 5.2.5 1. Is there at least 152.4 mm (6 in.) clearance between the intake opening and closed service opening room door? NFPA 82: 5.2.5 CHUTE DISCHARGE ROOMS 1. Is the rating of the discharge room at least equal to the rating of the chute enclosure? 3. Ensure trash chutes do not discharge directly to an incinerator. NFPA 82: 5.2.4 1. Are sprinklers installed in the chute discharge room in accordance with NFPA 13? NFPA 82: 5.2.6.2 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 2 of 7) 101

LOCATION OF S AUTOMATIC S 1. Are gravity chutes protected internally with sprinklers installed in accordance with NFPA 13? NFPA 82: 5.2.6 1. Are sprinklers installed at or above the top service opening? 2. Are sprinklers installed at alternate floor levels? 3. Is a sprinkler located at the lowest service level? NFPA 82: 5.2.6 PART 2 FULL PNEUMATIC WASTE OR LINEN CONVEYING SYSTEMS CHUTE DESIGN AND INSTALLATION INTAKE OPENINGS LOADING STATIONS MULTI-LOADING RISER PIPE AIR SOURCE RISER 1. Are chute intake doors installed at minimum of alternate floors? NFPA 82: 5.1.2 1. Are full pneumatic loading stations a minimum of 508 mm (20 in.) in diameter? 2. Is the inner door designed not to yield and is the door under pressure control? 3. Is the outer door a UL listed fire door of the appropriate fire rating based on the chute enclosure? 4. Is the outer door a minimum of 457 mm (18 in.) in diameter and side-hinged? 5. Is the loading station constructed of at least 14 U.S. gauge stainless or galvanized steel? NFPA 82: 5.3.2.1 1. Can only one inner door be opened at a time? NFPA 82: 5.3.2.2 1. Are riser pipes a minimum of 508 mm (20 in.) in diameter? 2. Are metal chutes made of stainless steel, galvanized steel or aluminum-coated steel with no screws, rivets, or other projections on the interior surface? 3. Are metal chutes at least 16 U.S. gauge? 4. Is riser pipe flanged, gasketed, and bolted? NFPA 82: 5.3.2.4 1. Is the air source the full-diameter of the riser pipe? 2. Is the air source roof vent and curb, all-weather elbow, or a louver through the side of the building? NFPA 82: 5.3.3.1 1. Are risers serving multiple floors enclosed in fire-rated construction? a. Is rating 1-hr with 1-hr opening protection for 3 stories or less? b. Is rating 2-hr with 1½-hr opening protection for 4 stories or more? NFPA 82: 5.3.3.1 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 3 of 7) 102

CHUTE DISCHARGE DOORS CHUTE INTAKE DOORS SEPARATION LOCATION OF S CONSTRUCTION 1. Is the bottom of waste chutes protected by automatic or self-closing doors constructed to meet the required fire rating? (UL label and latch are not required). 2. Is the bottom of linen chutes protected by a UL listed, automatic or self-closing fire door to meet the required fire rating? 3. Are chute discharge doors held open to automatically close (fusible link is acceptable method)? NFPA 82: 5.2.3.2 1. Are all intake doors UL listed, automatic or self-closing fire doors to meet the required fire rating? 2. Is the area of the intake door for a general access chute limited to: a. 1/3 the cross-sectional area of a square chute or b. 44 percent of the area of a round chute? 3. Do limited access chutes require a key to access the intake door? 4. Is the area of intake doors to limited access chutes limited as follows: a. Waste chute 2/3 the cross-sectional area of the chute b. Linen chute the cross-sectional area of the chute? NFPA 82: 5.2.3.3 SERVICE LOADING ROOMS 1. Are service openings located within a room or compartment separated from other parts of the building? NFPA 82: 5.3.2.3 1. Is the service opening room enclosed in fire-rated construction of at least 1-hr construction with ¾-hr opening protection? NFPA 82: 5.3.2.3 AUTOMATIC S 1. Are pneumatic chutes protected internally with sprinklers installed in accordance with NFPA 13? NFPA 82: 5.3.4 1. Are sprinklers installed at or above the top service opening? 2. Are sprinklers installed at alternate floor levels? 3. Is a sprinkler located at the lowest service level? NFPA 82: 5.3.4 TRANSPORT PIPING 1. Is transport piping a minimum of 406 mm (16 in.) in diameter where materials are not shredded prior to entering the system? 2. Is transport piping made of stainless steel or galvanized steel? 3. Are metal chutes at least 16 U.S. gauge? NFPA 82: 5.3.2.4 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 4 of 7) 103

FLOOR ASSEMBLIES INTERLOCK SHAFT/RISER ASSEMBLIES DISCHARGE ROOM PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES 1. Are automatic fire dampers provided where transport systems penetrate rated floor assemblies? NFPA 82: 5.3.5.2 1. Is the system designed to shut down when a fire damper closes? NFPA 82: 5.3.5.2 1. Is the piping thickness increased to a minimum of 11 U.S. gauge from within the shaft for a distance of 4 times the pipe diameter beyond the shaft wall? 2. Is the 11 U.S. gauge pipe supported every.92m (3 ft) interval? NFPA 82: 5.3.5.3 COLLECTOR DISCHARGE AREA 1. Is the enclosure of the discharge room at least 2-hr rated? NFPA 82: 5.3.6 1. Are sprinklers installed in the discharge room in accordance with NFPA 13? NFPA 82: 5.3.6.2 PART 3 GRAVITY PNEUMATIC WASTE OR LINEN CONVEYING SYSTEMS CHUTE DESIGN AND INSTALLATION GRAVITY WASTE AND LINEN CHUTE REQUIREMENTS GRAVITY CHUTE STORAGE SECTION SEPARATION DISCHARGE ROOM 1. Does the chute meet the requirements for gravity waste and linen chutes detailed in Part 1? NFPA 82: 5.4.2 1. Is a normally closed,11 U.S. gauge, blade-type damper installed at the bottom of the chute and above the funnel opening, when an open funnel is used as an interface between the gravity chute storage section and the transport discharge damper? 2. Is a discharge damper provided at the point of entry into the transport piping tee? NFPA 82: 5.4.2.2 1. Is sprinkler protection provided below the last service door on the chute where material is stored at the bottom of the chute and above the riser discharge damper? NFPA 82: 5.3.2.2 1. Where the gravity chute has an opening between the chute and the transport pipe, is the opening in a room protected with construction at least equivalent to the fire-rating of the shaft enclosing the chute? NFPA 82: 5.4.2.4 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 5 of 7) 104

CONSTRUCTION FLOOR ASSEMBLIES INTERLOCK SHAFT/RISER ASSEMBLIES DISCHARGE ROOM TRANSPORT PIPING 1. Is transport piping a minimum of 406 mm (16 in.) in diameter where materials are not shredded prior to entering the system? 2. Is transport piping made of stainless steel or galvanized steel? 3. Are metal chutes at least 16 U.S. gauge? NFPA 82: 5.4.3 PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES 1. Are automatic fire dampers provided where transport systems penetrate rated floor assemblies? NFPA 82: 5.4.3.2 1. Is the system designed to shut down when a fire damper closes? NFPA 82: 5.4.3.2 1. Is the piping thickness increased to a minimum of 11 U.S. gauge from within the shaft for a distance of 4 times the pipe diameter beyond the shaft wall? 2. Is the 11 U.S. gauge pipe supported every.92m (3 ft) interval? NFPA 82: 5.4.3.3 COLLECTOR DISCHARGE AREA 1. Is the enclosure of the discharge room at least 2-hr rated? NFPA 82: 5.4.4 1. Is sprinkler protection provided for rooms or areas where collector for discharge is within or abutting an occupied building in accordance with NFPA 13? NFPA 82: 5.4.4.3 PART 4 MAINTENANCE ALL WASTE AND LINEN CHUTES AND TRANSPORT SYSTEMS DISCHARGE DOORS INSPECTION SCOPE AND FREQUENCY 1. Are all chute loading and discharge doors maintained clear and unobstructed at all times? NFPA 82: 10.2.1 1. Are entire systems, including loading and discharge doors, inspected and maintained not less than annually in accordance with the manufacturer s instructions? NFPA 82: 10.2.2 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 6 of 7) 105

DISCHARGE DOOR WITH FUSIBLE LINK RECORDS 1. If a fusible like is provided, does the inspection of the discharge door arrangement include: a. Ensuring fusible link is not painted or coated with excessive dirt or dust? b. Evaluation of chains/cables, or other devices to ensure door will close? c. Removing the fusible link for testing every 4 years to ensure full closure and positive latching? d. Re-installing the fusible link after testing? e. Replacing the fusible link if damaged or not operational with same size, temperature and load rating? NFPA 82: 10.2.2 1. Is there a signed, written record of the inspection available for review? NFPA 82: 10.2.3 Copyright 2013 by Jones & Bartlett Learning, LLC, an Ascend Learning Company (Page 7 of 7) 106