Ideasandformsinevolution

Similar documents
ACCUMULATION OF EUROPEAN CLASS

The mechatronics of EVE 05

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

THE PERFECT CONDENSATION

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

STILE BEAUTY AND TECHNOLOGY

SPECIFICATIONS - NIKE

AIREX 2S WOOD PYROLYSIS SUCKING FAN

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

white blue cobalt bordeaux light oak (rovere)

Flue gas condensation...

C Tahiti. condensing

1 VICTRIX ZEUS Superior kw I features

Condensing, pre-mixed, wall-hung gas boilers with water tank

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Ciao Green Condensing Wall-Hung Boilers

UP TO 35 kw HE Collection

THE PERFECT CONDENSATION

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Power X High Power Condensing Wall-Hung Boilers

The guarantee on this appliance is valid for 12 months from the first day of installation.

Floor standing boilers. RMG Mk.II RS Mk.II

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

The iqe Boiler Range. Combination and System T Boilers.

Capri B Cast iron combination oil-fired boiler with water tank

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

VICTRIX Superior kw Export VICTRIX Superior kw X Export

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Capri R CH only, oil-fired, cast iron boiler

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Power X High Power Condensing Wall-Hung Boilers

Mynute Green Condensing Wall-Hung Boilers

VELA COMPACT INSTALLATION USE AND MAINTENANCE

FORMENTERA CTN RTN CTFS RTFS

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Metering systems 0548EN April 2014

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Seradens Super Seradens Super Plus

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

PICTOR DUAL CTN 24/RTN 24 CTFS 24/RTFS 24 CTFS 28/RTFS 28 INSTALLATION USE AND MAINTENANCE IST 04 C

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

DOMESTIC HOT WATER Follow operational sequence

DUA plus st edition - 09/2010 INSTALLATION AND USER INSTRUCTION MANUAL

EVE 05 RTN 24 - RTFS 24 CTN 24 F - CTFS 24 F CTN 24 - CTFS

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

PCH/new Series. High performance, total flexibility

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSION: PART NO.: AST 14 C 256/00. Wall-hung atmospheric boilers

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

thea 35 MR/MN Kondens Wall-mounted condensing boiler

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

CITY OPEN - CITY BOX from 25 to 35 kw

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

ENERGY TOP. Condensing boiler solutions

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Bithermal Wall-hung boiler with integrated heat exchanger

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Mikrofill Ethos Condensing combination boiler

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

GAS-FIRED FLOOR-STANDING BOILERS

RIELLO 40 GS/M SERIES

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

STM Department TRAINING MODULE. : instantaneous. Version 1.0, Jan 2006

HT V2 HT Split

Light oil - kerosene burner

WHE 2.24 / WHE 2.24 FF

Light oil burners. One stage operation

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Rapid. Suspended Warm Air Heater. Caring for the environment!

INSTRUCTION FOR THE USER THC V E OIL BLU

.it AQ USER OPERATING INSTRUCTIONS

WOLF GAS CONDENSING BOILERS COMFORTLINE

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

AUS. Format 34I-34E BF

INSTALLATION AND OPERATION MANUAL

MAINTENANCE AND SERVICE GUIDE

Transcription:

Ideasandformsinevolution TYPE natural draught room sealed electric diverting valve RTN 24 CTN 24 E RTFS 24 CTFS 24 E DUA PLUS is a natural draught or room sealed forced draught wall hung gas boiler, with electronic ignition, ideal to satisfy all the customer s needs, who pretends quality and high performances, joined to the dependability, the traditional UNICAL s mission, whose this product is the evolution confirmation. DUA PLUS is a boiler which conjugates the past with the future, taking, as reference, the bases of the experience made with the previous model with the addition of all the most advanced technology, to supply the user with the maximum well-being. No other competing boiler can, in fact, summarize in an unique model, the contents of DUA PLUS: the design solidity the flexibility of the D.H.W. priority systems the economy of management the practicality in the installation the quickness in the maintenance the simplicity of the controls the stylishness of the design

The mechatronics of DUA PLUS High efficiency by-thermal engine: > 92% Electrical Diverting valve Swinging panel board for a quick service Double safety, with two electronic ignition electrodes Pump with three selectable speeds and built-in air vent Manual adjustment and automatic action by-pass Simple use of the controls Led diagnostics for a quick fault finding TES (Thermostatic Energy Saver) economiser for GAS-WATER and TIME saving Room temperature modulating control Anti-frost protections

The well-being controls Easy to use DUA PLUS is designed to guarantee the maximum ease to the user. The panel board has been studied according to the most recent fundamental ergonomic rules: the selector switch of the primary functions is placed in the center, with, all around, the secondary controls. A series of led indicate the functions ON, show the temperatures of heating and domestic hot water and the type of fault which could have occurred within the boiler. Double scale thermometer through this thermometer it is possible to read: - the C.H. flow temperature on the L.H. side scale - the D.H.W. temperature on the R.H. side scale Reset button Button resetting the boiler operation after a lock-out of the burner control. Failure lamp: Indicates the lock-out of the burner control. Fault signaling lamp Indicates a fault in the boiler operation. Burner On Lamp Indicates the good operation of the burner. Supply line On Lamp Indicates the power supply is On. Outer sensor calibration button Adjust the compensation curve for the control of the room temperature depending on the outer temperature (it works only when the outer temperature sensor is fitted). Heating only position Summer position Winter position Off/anti-frost position Multifunction switch the boiler works for C.H. only. he boiler works for D.H.W. production only the boiler works for heating and D.H.W. production the boiler is Off; only anti-frost protection is On. Special functions button Starts the boiler for technical maintenance use. Signaling lamp is ON if the special functions button is in operation. Heating temperature adjustement This knob allows the adjustement of the C.H. flow temperature. Adjustement range: 35 to85 C. D.H.W. temperature adjustement This knob allows the adjustement of the D.H.W. temperature. Adjustement range: 35 to 65 C.

TES: Thermostatic Energy Saver Clever Saving with DUA PLUS Thanks to this patented device TES, the user, at each drawing of D.H.W., consumes and pays what he indeed uses. STRUCTURE OF THE TES DEVICE E POSITION OF THE TES P In the 1 st phase the TES allows the flow rate of approximately two liters per min of water with a temperature lower than 30 C. In the mean time the burner, at its maximum output, warms very quickly the water which, as it is possible to see, in the 2 nd phase causes the heating of the thermal sensitive element (wax) which, at its turn, pushes out the stainless steel shaft (P), causing the complete opening of the water pass. 1 st PHASE temp. < 30 C C 2 nd PHASE temp. 31 C TES Warm water E-Thermal sensitive element P-Stainless steel shaft C-Water pass Cold water The TES is made of a special thermal sensitive element, placed downstream the heat exchanger, which allows the D.H.W. passage at the maximum flow rate only when the water is really hot. The consumptions indicated in the beside figure, without and with TES, are considerably different. The saving depends on the number of water drawings. If we consider, as an example, a family of three persons, which normally makes 15 water drawings a day, the annual saving can reach 350 m 3 of gas and 70 m 3 of water. With DUA PLUS, then, the reduction of the costs and the reduction of gas and water waste is a reality. In the comparison between the DUA PLUS and an other boiler, it is clear that theduaplussaves,ateachdrawingof water, 69 liters of gas, 16 liters of water and 90 seconds to produce warm water at a temperature of 40 C. TO PRODUCE WATER AT 40 C GAS WATER TIME 108 litres 39 litres 23 litres 7 litres 150 sec. 60 sec. The comparison between a DUA PLUS and a boiler without TES highlights that to produce warm water at 40 C, DUA PLUS consumes only 39 liters of gas and 7 liters of water, waiting just 1 min.

The electric diverting valve The best solution WhytochoiceaDUAPLUSwithelectric diverting valve? Because only with this solution it is possible to combine the new systems of electronic controls, as the modulating chrono-thermostat TM 2000 with the control of the room temperature depending on the outer temperature. The motorised valve, electrically controlled by these devices, answers immediately to each signal, thus guaranteeing high precision in the temperature control and reducing the fuel consumptions. An alternative that UNICAL, notoriously in advance with its proposals, could not disregard for the well-being of the users. HYDRAULIC CIRCUIT OF DUA PLUS CTFS 24 E VE M C G C - Domestic Hot Water outlet G - Gas inlet F - Domestic Cold Water inlet VE - Electric valve M -C.H.flow R - C.H. return F R

DUA PLUS for the maximum comfort TA on off TA= Temperaturaambienteprescelta High efficiency outer compensator To get very high seasonal efficiencies and a pleasant room comfort, the precise room temperature control is fundamental. DUA PLUS is suitable to be connected with several types of chrono-thermostats, both On-Off and modulating type with external sensor. ON-OFF THERMOSTAT fig. 1 MODULATING CHRONO-THERMOSTAT On-off or modulating type. Which one to choice? The On-Off thermostat intervenes by switching On and Off the boiler when the room temperature is reached (fig. 1). The heating output and temperature are managed by the boiler. The actual room temperature is influenced by several variables, as the thermal inertia of the C.H. system and the answer delay of the thermostat: it follows a lower precision in the temperature control. The modulating chrono-thermostat TM 2000 controls directly the burner output adapting it immediately to the pre-set temperature (fig. 2). It results: a smaller number of switching On and Off, with a lower use of the devices (fan, gas valve, pump, etc.); a smaller heat loss through the chimney; a higher speed in reaching the steady state condition; a higher precision in the adjustment, because the radiators heating water temperature is continuously controlled by the room thermostat; TA fig. 2 TA= pre-setroom temperature reduction of the excessive radiators overheatings, which are the cause of dry air, reach in suspendible dusts, particularly annoying. The TM 2000 brainy comfort The self-adaptation: with an outer temperature lower than 8 C, speeds up the adaptation to the pre-set temperature. The pre-heating optimization: establishes the best advanced ignition to obtain the requested temperature at the requested time. AVAILABLE AS ACCESSORY Code No. 00261950 The outer sensor: the coupling of the On-Off chrono-thermostat with the outer temperature sensor controls the boiler output depending on the outer temperature, thus assuring the pre-set room temperature.

Easy installation and service Front access to all components DUA PLUS has been designed taking particular care to the easy use, to the quickness in the installation and to easy access to the components to facilitate the ordinary and extraordinary service, thus reducing the service costs. Largeare,infact,thespacesbetween the components and few are the tools required for service operations, all executable from the front of the appliance: two adjustable wrenches, a cross screw driver, a socket wrench, a multimeter, agaspressuregauge. Opening of the sealed room with quick fasteners Opening of the combustion chamber with release levers Burner removal by front sliding without removing the gas train Heat exchanger removal by front ward sliding Removal of the casing front and side panelbyverticalsliding Fan frontward removal with removal of just one screw Boiler connections at 15 cm from the rear wall to facilitate the installation

Accessories and mounting jig A standard pipes kit, the screw anchors and a mounting jig allow the quick mounting of the DUA PLUS, whilst other optional accessories complete the range. The professional installer can easily connect it to a digital or analogue room thermostat to optimize its operation. Every boiler is equipped with a metal mounting jig, with the indications concerning the wall fitting, the connection reference for the gas, cold water inlet, hot water outlet, C.H. flow and return. OUTER TEMPERATURE SENSOR Cod. SND 0140C DIGITAL WEEKLY CHRONO-THERMOSTAT SD 700 Cod. 00260738 ELECTRONIC ANALOGUE DAILY CHRONO-THERMOSTAT Cod. 00260737 KIT A KIT B 50 60 AIR/SMOKE COAXIAL DUCTS Cod. KIT5500C AIR/SMOKE SEPARATE DUCTS Cod. 00360535 30 65 65 65 65 30 M C G F R G C F M R M - Mandata impianto C - Acqua calda G - Gas F - Acqua fredda R - Ritorno impianto attacchi 3/4" 1/2" 3/4" 1/2" 3/4" Ø tubo rame 18 14 14 14 18 ISOLATING BALL VALVES KIT Cod. 00360682 DUA C/DUA PLUS C ADAPTATION KIT Cod. 00360457 METAL MOUNTING JIG Cod. 00360460

Safe protection The professional installer asks for performances of the products he installs, but also he asks for quick installations, free from obstacles, with the minimum impact for his clients. The casing is supplied, separate from the boiler, but in the same strong packing, to be fitted later on, when the installation is finished. Technical data Model DUA PLUS CTN DUA PLUS CTFS NOMINAL AND MINIMUM OUTPUT kw 24.01-11.07 24.35-10.84 NOMINAL INPUT kw 26.5 26.5 WATER EFFICIENCY AT 100% LOAD % 90.01 91.21 WATER EFFICIENCY AT 30% LOAD % 88.62 90.33 COMBUSTION EFFICIENCY AT 100% LOAD % 93.1 93.1 HEAT LOSSES THROUGH THE CASING MIN/MAX % 3.06-3.09 1.0-1.89 MAX SMOKE TEMPERATURE C 87 107.6 SMOKE FLOW RATE MIN/MAX g/s 17.7-19.5 15.93-15.58 CO 2 % 2.6-5.3 2.9-6.8 CHIMNEY HEAT LOSSES WITH BURNER IN OPERATION MIN/MAX APPLIANCE CATEGORY % 9.6-6.9 II2H3+ 12.3-6.9 II2H3+ 450 360 MIN WATER THROUGHPUT IN THE C.H. CIRCUIT WITH T = 20K l/min 7.8 7.8 C.H. CIRCUIT MIN/MAX WORKING PRESSURE bar 0.5-3 0.5-3 CLOSED EXPANSION VESSEL TOTAL CAPACITY C.H. CIRCUIT MAX WATER CONTENT * PRIMARY CIRCUIT WATER CONTENT D.H.W. MIN/MAX WORKING PRESSURE D.H.W. FLOW ADJUSTER l l l bar l/min 7 130 3.5 0.5-6 10 7 130 3.5 0.5-6 10 DIAGRAM FLOW RATE/MANOMETRIC HEAD 6 5 4 V3 3 V2 CONTINUOUS D.H.W. PRODUCTION MIXED ** l/min 13.7 13.7 2 V1 ELECTRICAL SUPPLY TENSION/FREQUENCY V-Hz 230/50 230/50 1 MAIN FUSE A(F) 4 4 0 100 300 500 700 900 1100 1300 MAXIMUM OUTPUT ABSORBED W 90 137 DEGREE OF PROTECTION IP X4D X4D NET WEIGHT kg 42 45 (*) Calculated for a maximum temperature of 90 C (**) Medium flow rate for a t=25k

AG S.p.A. 46033 casteldario - mantova - italy -tel. 0376/57001 (r.a.) - telefax 0376. 660556 - e-mail: info@unical-ag.com Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves theright to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.

AG S.p.A. 46033 casteldario - mantova - italy -tel. 0376/57001 (r.a.) - telefax 0376. 660556 - e-mail: info@unical-ag.com Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves theright to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.