CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Similar documents
CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Heating Controls Technical

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

User Manual THR870CUK Programmable Thermostat

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

SMART THERMOSTAT WITH HOT WATER CONTROL

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

User Manual THR872CUK Wireless Programmable Thermostat

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

AUTO CM CM USER GUIDE

Honeywell Homes T3, T3M & T3R

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

User Guide for EHE & EHE Programmable Room Thermostat

User Manual THR842DUK Wireless Digital Thermostat

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Model: RT510RF. Installation Manual

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Digital Room Thermostat

User Guide Y9420H Sundial RF 2 Pack 2

ST9400A User Guide. Features

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

RF Programmable Room Thermostat User Instructions

Wired Solutions Wired Heating Control Products

CS027 User Instructions

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

Smartfit S Pack Installation Guide with 24Hr or 7 Day Room Unit

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Watts Under Floor Multi-zone Controller User Manual

Operating your heating system with the Prefect PRE5701 Programable Thermostat

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

C-Stat 17-ZW User Instructions

Drayton Digistat +3RF

Home. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE

Safety & Installation Instructions

Room thermostat with 24-hour time switch and large LCD

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

TEC210x-2 Series Networked Thermostats

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Model: RT310RF. Installation Manual

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Technical Data Manual

Model: PRT-TS / PRT-NTS

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

4 in 1 Digital Thermostat Control

Model: RT310. Installation Manual

T105 Advanced Remote Control Programmable Thermostat. User Manual

Digital Thermostat Models: VS30W and VS30B

GreenCon On/Off Room Thermostat

RF Programmable Room Thermostat Installation Instructions

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT

GreenCon On/Off Room Thermostat

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

ES3247B. 3 Channel Programmer. User and Installation Instructions

3 Channel Multi-Purpose Programmer User Instructions

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

T-32-TS Touchscreen Thermostat. Installation Manual

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Eswa DC-1. Thermostat for Floor Heating

Programmable Room Thermostat Installation Instructions

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

Home. evohome WiFi MULTI-ZONE SYSTEM

Smart Temp. Model

evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls.

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

T7984 A,B,C Electronic Modulating Control Thermostats

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

ThermoPlus AS2-RF & ASR-RF Installation Instructions

- Data Brochure tekmarnet 4 Thermostat 542e

Modulating clock thermostat

Operating Instructions Model : HC HC-N

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

T6984 A,D,E Electronic Floating Control Thermostats

Digital Room Thermostat for Heating Applications with 7-Day Time Program

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Model: Touch-RS. 1 Touch-RS

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

C7 Programmable, digital room thermostat. Operating Instructions

4 Wiring Brochure Wiring and

Digital Electronic Thermostat With RF

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation, service and operating instruction Cetetherm Mini Plus CM737 DHWC

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Transcription:

CM907- TRV PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET FEATURES Attractive, slim, ultra-modern styling makes it ideal for location in any type of home. 7-day heating program. A dynamic text display on the LCD that gives enhanced feedback to the user / installer. Up to 6 daily independent time and temperature level changes let you set 6 time and temperatures pairs to suit your lifestyle. LCD Backlighting to illuminate the display for easier viewing in low light conditions. Temporary programmed temperature override to override the programmed temperature till the next switch point. The TRV mode allows using the fireplace in the living room without compromising comfort in the rest of the house. When TRV mode is active the boiler is kept constantly on whilst Thermostatic Radiator Values control temperature in the house. The TRV mode can either be pre-programmed or switched manually. TRV button allows activation or cancellation of the TRV mode manually whenever this type of control is required. Party feature that temporarily maintains a selectable constant temperature for -23 hours, then returns to normal operation. Holiday button that provides energy savings by reducing to a constant temperature from to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return. Room Enquiry. EEPROM memory holds the user program indefinitely. OFF position has an integral frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. 24...230V 8A resistive, 3A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. indicator. The CM907-TRV thermostat is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments. The CM907-TRV is especially useful to control boilers in heating systems where an alternative heating source is used on a temporary basis (see FEATURES below). It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<8A). The CM907-TRV is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM907-TRV extra large LCD display, dynamic text display, button layout based on the same simple programming philosophy used on our acclaimed CM60 products and the introduction of an OK button, makes it easier to install and more user friendly. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product Minimum battery life of 2 years with low battery warning indicator. Built-in default heating program. Automatic Summer / Winter time change adjusts the time automatically to daylight saving time. Telephone interface can be fitted to allow remote switching between program modes and a fixed set-point. Surface or wall-box mounting options with trunking guides and wiring breakouts to simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. User Set-Up Mode allows extra functions to be set at the discretion of the user: AM-PM or 24hr time display. Resetting the heating profile to factory default. Enable / disable of Auto Summer / Winter time change. Languages selection of the user interface. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: Optimisation. Pump Exercise. Upper / Lower Set point Limit Adjust. offset. Minimum ON time. Cycle rate. Heat / Cool operation. Proportional Band Width. Diagnostic Mode to assist in faultfinding.

CONTROLS/DISPLAY LAYOUT PRODUCT LAYOUT:. Day & Date Display 2. Time Display 3. Dynamic Text Display (DTD) 4. Burner On Indicator 5. Battery Low Indicator 6. Display 7. Change Buttons 8. Information Enquiry Button 9. Slider Switch 0. Green OK Button. Program Buttons 2. Battery Cover 3. Battery Compartment 4. Holiday Button 5. Party Button 6. TRV Button 7. Copy Day Button 8. Day Select Button 9. Time Change Buttons SPECIFICATIONS Batteries Battery life Battery replacement Switch type Electrical rating Time display Time keeping accuracy Program Time setting resolution : 2 x.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : SPDT (potential free) : 230 V~, 50...60 Hz, 0.5 A to 8 A resistive 0.5 A to 3 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 8 A resistive 0.5 A to 3 A inductive (0.6 pf) : 24 hour or 2 hour AM/PM format : Typically better than 0 minutes per year : 7-day with 6 daily time and temperature level changes : Time of day - minute Program - 0 minute steps Sensing element : 00K (@ 25 o C ) NTC thermistor setting range : Program : 5 to 35 o C in 0.5 o C steps Frost : 5 o C or equal to lower limit (5 o C to 2 o C). Frost protection does not work in cooling mode. control accuracy Room display range Control form Minimum ON time Cycle rate Wiring Wire access : ±0.5 K (nominal) @ 20 o C, 50% load 3 K Δ/hour : From 0 o C to 50 o C : P + I (Proportional + Integral) : 0% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting wires up to 2.5 mm 2 : Mains wiring rear right. Low voltage wiring rear right. Dimensions : 33 x 89 x 26 mm (w x h x d) 33 x 75 x 26 mm (w x h x d) (flap open) Environmental Approvals : Operating temperature range 0 to 40 o C Shipping and storage temperature range -20 to 55 o C Humidity range 0 to 90% rh, noncondensing : Designed to meet European EN approvals EN60730-(Nov 2000), EN5504- (997), EN5504-2 (2000) 2

INSTALLER SET-UP To enter the installer set-up mode: a) Move the slider switch to the OFF position. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category (from n. to n.9). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n. to n.5). h) To exit the installer mode, move the slider switch to the AUTO or MAN positions. Abbreviated Set-Up Description e.g. Cl = Clock Format Factory Setting or New Choice Press TEMP or to change e.g. 2 = AM/PM Format 24 = 24hr Format In Installer set-up we can: Set-up specific applications Enable special features Establish support for optional accessories Installer Set-up Number (Press + or - to change) e.g. = Clock Format Brief Description of the Parameter Function. Specific Applications Setting What do you need to change? Cycle/ Hour Minimum ON time (in minutes) Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n., category 2 in the installer set-up mode. Heating Gas Boilers (<30KW) 6 No action required Oil Boiler 3 4. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Thermal Actuator 2 Set Cycle/Hour to 2. Zone valve 6 No action required. Electric heating (for applications <8A) 2. Configure the thermostat for electric heating (set parameter n.3, category 2 in the installer set up mode to ). 2. Set Cycle/Hour to 2. Air conditioning Heat Pump/ Air conditioner. Configure the thermostat to allow switching between heating and cooling modes (set parameter n.4, category 2 in the installer set-up mode to ) 2. Set the thermostat accordingly to the required mode of operation (heating or cooling) by pressing the TEMP or buttons together for 5 seconds. Modify the cooling program as required. 3 4. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. 2 Fan coil 6 No action required. 3

Special Features Description What to do if we wish this feature Optimisation (Variable Start Time) Adaptive Intelligence recovery TM The thermostat will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period e.g. Time 7:00, Temp 2 o C. The thermostat will monitor the accuracy of the start up and use this information to modify the calculation for the following day by changing the ramp rate (initial 3 K/hr).The system will restrict the start time to a max of 2 hours. Note: Optimisation will not work in cooling mode. Set parameter n.8, category in the installer set-up mode to. AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n., category in the installer set -up mode to 2. Pump exercise Upper Limit Lower Limit Offset Proportional Band Width When enabled the Pump Exercise will switch the relay on for minute at 2:00 if the relay has not been switched on since 2:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 35 o C can be reduced down to 2 o C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 o C can be increased up to 2 o C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 o C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 o C (default is.5 o C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response. Set parameter n.5, category 2 in the installer set -up mode to. Set parameter n.6, category in the limit. Set parameter n.7, category in the limit. Set parameter n.2, category in the offset value. Set parameter n.3, category in the value. Optional Accessories Outside Sensor (F420097 00) Remote Sensor (F4200972 00) Description An Outside Sensor can be fitted, allowing the homeowner to display the outside temperate on the thermostat display by pressing the INFO i button. The thermostat will read the outside temperature every 0 minutes. Outside temperature display range is from -30 o C to +45 o C. The sensor can be connected up to 50 meters from the unit. A Remote Sensor can be fitted, allowing the thermostat to control the temperature from another room or space, where it is inconvenient to locate the thermostat. It will read the remote sensor every minute. The sensor can be connected up to 50 meters from the unit. Useful for commercial premises where the public may tamper with the product. What to do if we wish this feature. Fit the sensor (instructions included in the sensor package). 2. Set parameter n. 0, category in the installer set-up mode to.. Fit the sensor (instructions included in the sensor package). 2. Set parameter n. 0, category in the installer set-up mode to 2. 4

Parameter Installer Set- Up Number / Abbreviation (Press + or - keys to select) Factory Setting Optional Setting Installer Set- Up Category Display Description Display/Setting Description (Press PROG keys < or > to select) Category : Thermostat Parameters AM-PM / 24hr Display :Cl 24 24 hr clock display 2 2 hr AM / PM clock display RESET Time / Program 2:rP Time / profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 Time / are as programmed To restore the factory profile set to Automatic Summer/Winter Time Chqnge 3:tC Automatic Summer/Winter Time Change Enabled 0 Automatic Summer/Winter Time Change Disabled Backlight Display 5:bL Backlight Display Enabled 0 Backlight Display Disabled Upper Limit 6:uL 35 35 C Upper Temp. Limit 2 to 34 2 C to 34 C adjustment in C steps Lower Limit 7:LL 5 5 C Lower Temp. Limit 6 to 2 6 C to 2 C adjustment in C steps Optimisation 8:0P 0 Optimisation disabled Optimisation enabled Remote Control Setpoint (e.g. via telephone module) 9:tS 0 Disabled Enabled Second Sensor Offset 0:SS 0 No sensor fitted, 2 - Outside Sensor fitted 2 - Remote Temp. Sensor fitted 2:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0. C steps Proportional Band Width 3:Pb.5.5 C Proportional Band.6 to 3.0.6 C to 3.0 C adjustment in 0. C steps Reset Parameters to Factory Defaults 9:FS All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified above To restore the factory profile set to Category 2: System Parameters (You must press the > program key to enter this section) Minimum boiler ON Time :Ot minute minimum ON time 2 to 5 2-2 minutes 3-3 minutes 4-4 minutes 5-5 minutes 2 Cycle Rate 2:Cr 6 6 cycles per hour (cph) for gas boilers, zone valves and fancoil 3, 9, 2 3-3 cph 9-9cph 2-2 cph 2 Electric Heat 3:Eh 0 Applications < 3A Applications 3-5A 2 Heat / Cool Change 4:HC 0 Disabled Enabled 2 5

DIMENSIONS INSTALLATION LOCATION The CM907-TRV thermostat is the control element of the heating / cooling system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall.5 metres, above the floor level. Do not position the CM907-TRV thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM907-TRV thermostat can be mounted directly on the wall surface or on an electrical wallbox. WIRING The CM907-TRV thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT. The installer must be a trained service engineer 2. Disconnect the power supply before beginning installation 6

WIRING ORDERING SPECIFICATION Description Model Logo Literature Availability Spec Sheet 7-day programmable thermostat CMT907A082 Honeywell French & Dutch. Aug 06 ENOH8555 Remote Sensor F4200972 00 Honeywell Multi-lingual Sep 06 ENOH8554 Outdoor Sensor F420097 00 Multi-lingual Sep 06 ENOH8553 Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML 5SB United Kingdom http://europe.hbc.honeywell.com