LOW TEMPERATURE INCUBATOR MODEL: 2005 INSTALLATION AND OPERATIONAL MANUAL. Revised 1/

Similar documents
ECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL

BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/

WATER BATHS GENERAL PURPOSE MODELS: 1265PC, 1275PC, 1285PC MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL

INCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL

REACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

HUMIDITY CHAMBER MODELS: 9005 / 9010 / 9005L / 9010L WITH MICRO PROCESSOR CONTROL INSTALLATION AND OPERATION INSTRUCTIONS REV.

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

VACUUM OVENS MODEL: , , INSTALLATION AND OPERATIONAL MANUAL

HORIZONTAL AIR FLOW OVENS MODEL: 1601, 1602, 1605, 1670, 1675, 1680, 1685, 1690

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

INSTALLATION AND OPERATION MANUAL

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LOW TEMPERATURE DIURNAL ILLUMINATION INCUBATOR MODEL: INSTALLATION AND OPERATION MANUAL Revised 11/

SHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS SHC10R SHC28 SHC28R HUMIDITY CHAMBER. Revised March 19,

HORIZONTAL AIR FLOW CLEAN ROOM OVEN

VACUUM OVEN MODEL: 1425, 1445 & idealvac.com (505)

INSTALLATION AND OPERATION MANUAL

Revised 01/

FS Series Forced Air Ovens. Operation and Service Manual

BOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual /12

1585/1585R Orbital Shaking Incubator Operational Manual Sheldon Manufacturing Inc. INTERNET:

DROSOPHILA SPECIFIC INCUBATORS SRI21F SRI21F-2 Previously designated LIFLY LIFLY-2 Installation and operations manual. Revised 4/

DROSOPHILA SPECIFIC INCUBATORS MODEL: LIFLY & LIFLY-VIEW Installation and operations manual

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

BEAD BATH. MODELS: , , & , , & V/ V Models INSTALLATION AND OPERATION MANUAL

User Manual

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

InstructIon Manual KrEs EQuIPMEnt stands

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Isotemp Plus General Purpose Laboratory Freezers

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Solid Door Top Mount Reach-In Freezer

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Glass Door Merchandiser Refrigerator and Freezer

Ui REFRIGERATOR SPEC SHEET

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

RPI Industries, Inc.

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Chef Base Refrigerators

Outdoor Beverage Center

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

2.4 Cu. Ft. Compact Refrigerator

Models: SSI5 SSI5-2 SSI5R SSI5R-2

REFRIGERATED CONDIMENT RAIL

User Manual / Installation Instructions

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Dual Zone Wine Cellar

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Insta-Therm Series Service, Installation and Operation Manual

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

User Manual. Commercial Refrigerator And Freezer User s Manual

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Owner s Manual Window Air Conditioner

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

3.2 CU FT REFRIGERATOR

Wine Cellar. Instruction Booklet. Model: WC-2038

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

T-Series Air Conditioner T20 Model

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Isotemp Explosion-Proof Refrigerators and Freezers

AHPO-6/18 GOLD PROOFER OVEN

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

Transcription:

LOW TEMPERATURE INCUBATOR MODEL: 2005 INSTALLATION AND OPERATIONAL MANUAL Revised 1/2015 4861388

TABLE OF CONTENTS SECTION 1.0 SECTION 2.0 SECTION 3.0 SECTION 4.0 SECTION 5.0 SECTION 6.0 SECTION 7.0 RECEIVING AND INSPECTION INSTALLATION CONTROL OVERVIEW OPERATION MAINTENANCE TROUBLESHOOTING PARTS LIST UNIT SPECIFICATIONS SCHEMATICS This unit is a general purpose Biochemical Oxygen Demand (BOD) incubator for professional, industrial or educational use where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. This unit is not intended for hazardous or household locations or use. 2

RECEIVING AND INSPECTION Section 1 Your satisfaction and safety require a complete understanding of this unit. Read the instructions thoroughly and be sure all operators are given adequate training before attempting to put the unit in service. NOTE: This equipment must be used only for its intended application; any alterations or modifications will void your warranty. 1.1 Inspection: The carrier, when accepting shipment, also accepts responsibility for safe delivery and is liable for loss or damage. On delivery, inspect for visible exterior damage, note and describe on the freight bill any damage found, and enter your claim on the form supplied by the carrier. 1.2 Inspect for concealed loss or damage on the unit itself, both interior and exterior. If necessary, the carrier will arrange for official inspection to substantiate your claim. 1.3 Return Shipment: Save the shipping crate until you are sure all is well. If for any reason you must return the unit, first contact your customer representative for authorization. Supply nameplate data, including model number and serial number. Please see the manual cover for information on where to contact Customer service. 1.4 Accessories: Verify that all of the equipment indicated on the packing slip is included with the unit. Carefully check all packaging before discarding. This unit is equipped with 2 shelves and a humidity pan/ WARNING: Never use this unit for the growth, cultivation, incubation or storage of fruit flies (drosophila melanogaster). This unit is not designed for use with fruit flies. Improper use of this unit (including use with fruit flies) voids the warranty. Other units are specifically manufactured for fruit fly application, and you should consult your dealer or the manufacturer in order to identify another model suitable for your application. 3

INSTALLATION Section 2 Local city, county or other ordinances may govern the use of this equipment. If you have any questions about local requirements, please contact the appropriate local agency. Installation may be performed by the end user. Under normal circumstances this unit is intended for use indoors, at room temperatures between 5 and 40 C, at no greater than 80% Relative Humidity (at 25 C) and with a supply voltage that does not vary by more than 10%. Customer service should be contacted for operating conditions outside of these limits. This unit should remain upright for 24 hours prior to turning on. This will allow the oil settle to in the refrigeration compressor. 2.1 Power Source: The electrical supply circuit to the incubator must conform to all national and local electrical codes. Consult the incubator s serial data plate for the voltage, cycle wattage and ampere requirements before making connection. VOLTAGE SHOULD NOT VARY MORE THAN 10% FROM THE SERIAL PLATE RATING. This unit is intended for 50/60 Hz application. A separate circuit is recommended to prevent possible loss of product due to overloading or failure of other equipment on the same circuit. 2.2 Location: When selecting a site for the incubator, consider all conditions which may affect performance, such as extreme heat from steam radiators, stoves, ovens autoclaves, etc. Avoid direct sun, fast-moving air currents, heating/cooling ducts, and high traffic areas. To ensure air circulation around the unit allow a minimum of 20cm between incubator rear and sides and any walls, partitions or obstructions to free airflow. 2.3 Lifting / Handling: This unit is heavy and care should be taken to use appropriate lifting devices that are sufficiently rated for these loads. Units should only be lifted from their bottom surfaces. Doors, handles and knobs are not adequate for lifting or stabilization. The unit should be completely restrained from tipping during lifting or transport. All moving parts, such as shelves and trays should be removed and doors need to be positively locked in the closed position during transfer to prevent shifting and damage. 2.4 Leveling: The unit must sit level and solidly. Turn the leveling feet counterclockwise to raise level. If the unit must be moved, turn the leveling feet in all the way to prevent bending and damage. 2.5 Cleaning: The incubator interior was cleaned at the factory, but not sterilized. Remove all interior parts and clean with a disinfectant that is appropriate for your application. DO NOT USE abrasives as this will damage the incubators interior. DO NOT USE spray cleaners that might leak through opening and cracks and get on electrical parts or that may contain solvents that will harm the coatings. A thorough periodic cleaning is strongly recommended. WARNING: Never clean the unit with alcohol or flammable cleaners with the unit connected to the electrical supply. Always disconnect the unit from the electrical service when cleaning and assure all volatile or flammable cleaners are evaporated and dry before reattaching the unit to the power supply. 4

CONTROL PANEL OVERVIEW Section 3 3.1 Power Switch: The main power I/O (on/off) switch controls all power to the unit and must be in the I/ON position before any systems are operational. 3.2 Main Temperature Control: This control is marked SET TEMPERATURE and consists of the digital display and UP/DOWN arrow pads for inputting set point temperatures and calibration. 3.3 Heating Lamp: This pilot lamp is marked TEMPERATURE ACTIVATED and is ON when the unit is heating up to set point and is blinking when controlling temperature at set point. 3.4 Overtemperature Thermostat: This control is marked SET OVERTEMPERATURE and is completely independent of the Main controller. It acts as an override in the event that the Main control fails in the ON position. 3.5 Overtemperature Light: This pilot lamp is marked OVERTEMPERATURE ACTIVATED and is on when the thermostat has been activated. Under normal operating conditions, this pilot light should never be on. 3.6 Circuit Breaker: (Non-CE units) Adjacent to the power cord the circuit breaker is an added measure of protection against power source variations that if tripped, must be reset by pushing in the button once the reason for interruption has been cleared. 3.7 Fuse: (CE units only) Located at the back of the unit within the power inlet, the fuse is an added measure of protection against power source variations that, if blown, must be replaced once the reason for the interruption has been cleared. Note that the unit will not power up unless the fuse is in place. 5

OPERATION Section 4 4.1 Check power supply against unit serial plate. They must match. 4.2 Plug service cord into the grounded electrical outlet. 4.3 Push the power switch to the I/On position, and turn the Overtemperature Thermostat to its maximum position, clockwise using a coin or flat edged tool. 4.4 Set Main Temperature Controller: Enter desired set point temperature. To enter set point mode on the controller, press either the Up or Down arrow pad one time. The digital display will start to blink, going from bright to dim. While blinking, the digital display is showing the set point. To change the set point, use the Up and Down arrow pads. If the arrow pads are not pressed for five (5) seconds, the display will stop blinking and will read the temperature of the unit. Note that the Overtemperature Thermostat should be turned to its maximum position, (clockwise) until the unit has stabilized at desired set point temperature. Allow the incubator at least 24 hours to stabilize. 4.5 Calibration: It is recommended that calibration is done once the unit is installed in its working environment and has been stabile at set point for several hours. Place a certified reference thermometer in the chamber. Be certain the thermometer is not touching any shelving. Allow the temperature to stabilize again until the thermometer reads a constant value for one hour. Compare the digital display with the reference thermometer. If there is an unacceptable difference, put the display into calibration mode by pressing both the Up and Down arrow pads at the same time until the two outside decimal points begin to flash. While the decimal points are flashing the display can be calibrated by pressing the Up or Down arrow pads until the display reads the correct value. Allow the incubator temperature to stabilize again, and recalibrate if necessary. 4.6 Set Overtemperature Thermostat: As mentioned previously, the Overtemperature Thermostat should be initially set to its maximum position, (clockwise), to allow the unit to stabilize. Once the incubator is stabile at the desired set point, turn the Overtemperature Thermostat counterclockwise until the OVERTEMPERATURE ACTIVATED light turns on. Next, turn the Thermostat clockwise just until the light turns off. Then turn the Thermostat clockwise 1/16 of an inch past the point where the light went out. This will set the Overtemperature Thermostat at approximately 1 C above main Temperature set point. 4.7 Accessory Outlet: This unit has been supplied with a 1 amp accessory outlet inside the chamber to provide power for equipment such as magnetic stirrers, rockers, etc. Be certain the apparatus draws 1 amp or less. The power switch on the front panel controls power to the outlet. Note that the apparatus may provide additional heat that could affect the temperature range of this incubator. It is recommended that testing be done with the incubator and any accessory equipment to insure that the desired operating conditions can be met. 6

4.8 Load the chamber with sample bottles. See Figure 2 for bottle placement. Figure 2 7

MAINTENANCE Section 5 Note: Prior to performing maintenance and/or service on this incubator, disconnect the unit from the power supply. 5.1 Cleaning: Cleaning and decontamination are recommended on a regular basis. To prepare the unit for cleaning, disconnect the power cord and remove all interior parts, such as shelves, trays, etc. First clean the chamber with soap and water, rinse and let dry. To decontaminate use a solution that is appropriate for your application. DO NOT USE abrasives as this can damage the chamber interior. DO NOT USE spray cleaners that might leak through openings and cracks and get on electrical parts or that may contain solvents that will harm the coatings. NEVER USE acids, chemical thinner, gasoline, benzene or like chemicals for cleaning the unit. Boiling water and benzene can deform and damage plastic parts. WARNING: Never clean the unit with alcohol or flammable cleaners with the unit connected to the electrical supply. Always disconnect the unit from the electrical service when cleaning and assure all volatile or flammable cleaners are evaporates and dry before reattaching the unit to the power supply. 5.2 Compressor Compartments: Located at the back and bottom of the unit, the compressor compartment can collect dust that will inhibit proper air flow. This compartment should be vacuumed out at least once every six (6) months to ensure maximum efficiency. 5.3 Defrosting: Generally defrosting should not be necessary. If ice build-up occurs it is usually attributed to open containers, loose closures or frequent door openings causing excessive moisture to build up in the chamber. Try to eliminate these as possibilities. To defrost, remove all items from the chamber and let the unit stand with the door open and the POWER OFF. Once frost is gone, empty drip tray, wipe the chamber dry and power up the unit. 5.4 Storage: If the incubator is to be shut down for storage or transport, remove all items, drip tray and shelves and be certain the chamber is dry. Screw in the leveling feet. Review section 2.3, Lifting / Handling for transport instructions. 5.5 There is no maintenance required on electrical components. If the unit fails to operate as specified, please review section 6 Troubleshooting, prior to calling for technical service. 8

TROUBLESHOOTING Section 6 FOR PERSONAL SAFETY, ALWAYS DISCONNECT THE POWER BEFORE SERVICING. In the event the incubator does not operate properly, check the following before calling for service. Always make a visual inspection of the incubator and control console when troubleshooting to find loose or disconnected wires which may be the source of trouble. TEMPERATURE Temperature too high Display reads "HI" Temperature too low Display reads "LO" Unit will not heat up at all Indicated chamber temperature unstable Display and reference thermometer don t match Can't adjust set points or calibration Calibrated at one temperature, but not at another Unit will not cool Controller set too high. Probe is unplugged, is broken or wire to sensor is broken. 1/ Overtemperature thermostat set too low. 2/ Controller set too low. 3/ Unit not recovered from door opening wait for display to stop changing. 4/ Unit not recovered from power failure or being turned off incubators will need 24 hours to warm up and stabilize. Sensor is shorted. 1/ Verify that controller is asking for heat by looking for controller light 2/ Do all controller functions work? 3/ Is the Overtemperature set high enough? 1/ ±0.1 may be normal 2/ Is fan working? 3/ Is ambient room temperature radically changing either door opening or room airflow from heaters or air conditioning? stabilize ambient conditions 4/ Overtemperature set too low. 5/ Electrical noise remove nearby sources of RFI including motors, arcing relays or radio transmitters Calibration error. 1/ Turn entire unit off and on to reset 2/ If repeatedly happens, call Customer Service This can be a normal condition when operating temperature varies widely. For maximum accuracy, calibration should be done as close to the set point temperature. REFRIGERATION If the compressor is running: 1/ See if condenser is cold but free of ice 9

Ice build up in chamber Making noise Motor doesn't move Motor makes noise Door not sealing Unit or wall fuse/circuit breaker is blown Unit will not turn on Contamination in chamber 2/ Be sure that fans are circulating air: in the chamber, and over the compressor 3/ Assure there is ample room around the unit as described in Installation. 4/ Compare ambient specifications to Unit specifications. If compressor isn t running: 1/ Confirm that compressor cooling fan motor is operable a- Dirty coil or poor circulation b- Coil next to heat source c- Ambient temperature too high 1/ Search for leak in door gasket. 2/ door being opened too often. 3/ open container/loose seal on bottles. 1/ assure that fan is not miss-aligned. 2/ Steady internal clicking may be broken spring or valve call Customer Service. MECHANICAL If shaft rubs or is frozen, relieve binding and retest 1/ Make sure that the fan or blower wheel is not contacting its housing. Adjust the motor mounting bracket position to re-center the fan or blower wheel, if necessary. 2/ Check the fan or blower wheel for damage or out of balance condition. Replace the fan or blower wheel if it is damaged or out of balance. 3/ Turn the motor shaft to make sure that it spins freely. If it binds or the bearings make a rubbing or scrapping sound then replace the motor. 1/ Confirm that unit has not been damaged and body is square. 2/ Check to see that door gasket is in place and not damaged. OTHER 1/ Check wall power source 2/ Compare current draw to specs on data plate 3/ See what other loads are on the wall circuit 1/ Check wall power source 2/ Check fuse/circuit breaker on unit or in wall 1/ See cleaning procedure in operator s manual 2/ Develop and follow Standard operating procedure for specific application; include definition of cleaning technique and maintenance schedule 10

PARTS LIST Section 7 Description 115V 220V Circuit Breaker 1100505 1100505 Circulating Fan, chamber 4880545 4880545 Convenience Outlet 6100525 6100526 Cooling Fan, compressor 4880564 4880564 Factory Set Over- Temperature Control 1750715 1750715 Heating Element 2350508 2350508 44.6 ohms 150.1 ohms I/O (On/Off) Power Switch 7850570 7850570 Main Temperature Controller 1750967 1750968 OTP and Compressor High 1750862 1750813 Cut Thermostat Pilot Light, Green 4650554 4650554 Pilot Light, Red 4650553 4650553 Power Cord, USA 1800529 1800537 Step Down Transformer -- 8350515 11

UNIT SPECIFICATIONS Weight Shipping Net 2005 130 lbs. 108 lbs. Dimensions Exterior WxDxH (in.) Interior WxDxH (in.) 2005 20.75 x 21.25 x 38.75 15 x 11 x 25 Capacity 3 cubic feet Temperature Range Uniformity 2005 0 to 45 C +0.5 C @ 20 C 12

WIRE DIAGRAM 110V (9851370) 120VAC POWER CORD AND PLUG 1100505 CIRCUIT BREAKER 15A GREEN LIGHTED POWER SWITCH 7850570 OUTLETS 6100525 IF BLU 4880545 INTERNAL FAN SENSOR HOT NEUTRAL GROUND LOAD TEMPERATURE CONTROL 1750967 4650553 SAFETY ACTIVATED R ORG 4650554 HEATING ACTIVATED G 1 4 2 HT 1750715 155 F/68 C HT 45 HT 1750862 4 9570863 ELEMENT ASSY 2350508 ELEMENT COIL YEL 1 2 1750862 PRESET TO 35 C YEL YEL CF THE COMPRESSOR IS PART OF THE BASE UNIT 4880564 COMPRESSOR FAN 13

220V (9851371) POWER CORD 1800537 2800502 EMI FILTER FUSE FUSE GREEN LIGHTED POWER SWITCH 7850570 OUTLETS 6100526 HOT NEUTRAL GROUND TEMPERATURE CONTROL 1750968 LOAD SAFETY ACTIVATED ORN R 4650553 HEATING ACTIVATED 4650554 G 1 4 2 HT 1750715 155 F/68 C HT HT 4 2 1 HT ½ 1750813 9570864 ELEMENT ASSY 2350508 ELEMENT COIL ½ 1750813 8350515 TRANSFORMER 240/120VAC 750VA BRN BRN 4 THE COMPRESSOR IS PART OF THE BASE UNIT YEL 1 2 YEL 1750862 PRESET TO 35 C YEL CF 4880564 COMPRESSOR FAN BLU IF 4880545 INTERNAL FAN 14

O R D E R F R O M V W R Call 800-932-5000 Sales & Inventory Locations: Pacific Northwest Are ANCHO R A G E, A K Salt Lake City, UT San Francisco, CA Seattle, WA Tualatin, OR Southwest Area Albuquerque, NM Denver, CO Phoenix, AZ San Diego, CA S A N D I M A S, C A from anywhere in the U.S. and Canada Midwest Area Chicago, IL Detroit, MI Indianapolis, IN Minneapolis, MN St. Louis, MO Gulf Area Austin, TX Dallas, TX Houston, TX Lake Charles, LA Northeast Area Boston, MA Cincinnati, OH Cleveland, OH Pittsburgh, PA Rochester, NY Mid-Atlantic Area Baltimore, MD Branford, CT Bridgeport, NJ S. Plainfield, NJ Or Call Direct for Specialized Service Locations: VWR International 3000 Hadley Rd S. Plainfield, NJ 07080 (908) 757-4045 fax: (908) 757-0313 Puerto Rico Carr. #869 Km. 1.5 M4 Royal Industrial Park Catano, PR 00962 (787) 788-3222 fax: (787) 78804320 Switzerland Ruchligstrasse # 20 P.O. Box 464 Dietikon, Switzerland CH-8953 011-41-1-745-1155 fax: 011-41-1-745-1150 VWR Direct 911 Commerce Ct. Buffalo Grove, IL 60089 (800) 444-0880 Southeast Area Atlanta, GA Oak Ridge, TN VWR Canlab Offices Mississauga, Ontario Ville Mont-Royal, Québec Edmonton, Alberta VWR Furniture Division P.O. Box 3405 Irving, TX 75015 (972) 714-0336 VWR National Accounts 1310 Goshen Pkwy W. Chester, PA 19380 (610) 431-1700 Visit Our Web Site at http://www.vwrsp.com F:\manuals\vwr back sheet.doc