HYDROCARBONENGINEERING June June 2015

Similar documents
CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

COMBUSTION & FIRED HEATER OPTIMIZATION AN ANALYTICAL APPROACH TO IMPROVING SAFE & EFFICIENT OPERATIONS

Why AC800M High Integrity is used in Burner Management System Applications?

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Fired Heater Flooding

The key element for your process

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

Eclipse Self-Check UV Scanner

Zeeco recently had the opportunity

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

IE059: Boiler Control and Instrumentation for Engineers & Technicians

OIL AND GAS INDUSTRY

Amec Foster Wheeler- Fired Heater Division

DIRECTIVE NO: D-B

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Kolmetz Handbook Of Process Equipment Design BURNER MANAGEMENT SYSTEMS (ENGINEERING DESIGN GUIDELINE)

InstrumentationTools.com

MEP 599 Diploma Design Project- Fall Term 2016

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

The World s First Flameless Crude Heater

THE SIGNIFICANCE OF RELIABLE PRESSURE CONTROL IN OILFIELD BURNER SYSTEMS

Burners Flares Incinerators Vapor Combustion

ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

LOW-NOX BURNER RETROFIT CHALLENGE

Committee on NFPA 85

AS AS Australian Standard. Industrial fuel-fired appliances. This is a free 9 page sample. Access the full version online.

Meeting NFPA standards for

- Essay Control Functions and Benefits

ecodry Figure 1 - Process Diagram ecodry B General Process Description

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

Thank You for Attending Today s Webinar:

Eclipse 90 UV Scanner Model A Version 1

Improving the Performance and Reliability of Fired Heaters and Boilers

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

OPERATING AND MAINTENANCE MANUAL

Coker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX

Fuel and Energy Research Forum

THE WORLD S FIRST FLAMELESS CRUDE HEATER

Options for Developing a Compliant PLC-based BMS

Considerations for INDUSTRIAL COMBUSTION

Document Number March 23, 2016 Yokogawa Electric Corporation. Data Acquisition/Recorder. Data Acquisition and Monitoring. Paperless Recorder

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

The evolution of level switches and detectors

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Fire Safety PPT-SM-FIRESFTY V.A.0.0

PACKAGED COMMERCIAL WATERTUBE BOILERS

Pulse Firing Doubles Capacity and Cuts Fuel Costs

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

Engineering Standard. Saudi Aramco DeskTop Standards

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

An Oven Explosion Lessons Learned on PSM Concepts (or PSM: It s not just for breakfast anymore )

Safety Instrumented Systems

Monitoring Flammable Vapors and Gases in Industrial Processes

STEAMPAK Series BurnerPAK BMS Burner Management Systems

AirTrak. Digital Control System. User Manual. Touchscreen Systems

BURNER MANAGEMENT CONTROLS

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

HFID Heated Total Hydrocarbon Analyzer Module

NEW LINE BOILER CONTROLLERS

Installation & Operation Manual

Datalogging as standard

Originators of the Flexible Water Tube design

Rapid Response Series (RR e & RR i) OPERATING MANUAL

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Integrating Fire and Gas Safety with Process Control Systems:

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Efficiency & Savings through On-Line Chemical Cleaning

Flameless Technology Demonstration Heater

Power Flame Incorporated

HAWK INTEGRATED BOILER CONTROL SYSTEM

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

Boiler MACT Webinar Q/A

Refining and Petrochemical Heater trouble shooting

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

Zircomat Oxygen Analyzers

Cleaver-Brooks Webinars

intrinsically safe detector for hydrocarbon gases

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

SIHI dry Dry running vacuum pumps

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

BLABO. Non-man entry tank cleaning and oil recovery system. Automated tank cleaning and. Designed for large, containing crude oil or heavy fuel oil

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

SULPHUR RECOVERY UNIT

T.ex Single Gas Detector VISA

Intelligent Heating for Your Home

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Terminal Automation Solutions SmartRadar FlexLine Global Experience. Locally Applied.

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Transcription:

www.hydrocarbonengineering.com

Controlled Combustion Arthur Groenbos, Yokogawa Europe, discusses tunable diode laser gas analysis for combustion management in fired heaters. While fired heaters are used throughout refining and petrochemical processes as the source of process heat, they carry inherent risks and costs that make operating without current technologies problematic. To address safety concerns, industry standards are upgrading their recommended practice for instrumentation, control and protective systems for fired heaters and steam generators. While not yet required by regulation, plants not meeting the best industry practice guidelines will be at added risk in the event of an incident on a fired heater. Since many natural draught fired heaters do not meet this guideline with existing instrumentation and control systems, an upgraded system consisting of recommended technologies will be needed. Furthermore, since most natural draught fired heaters have only automated control of the fuel supply and not the air, excess air is often applied to the combustion process, thereby reducing thermal efficiency. According to ARC Insights, second only to raw materials costs, energy is the leading cost pressure currently affecting manufacturers. New analysis techniques, such as tunable diode laser spectroscopy (TDLS), can improve efficiency, maximise throughput, reduce emissions, and improve safety and reduce energy in combustion processes. This article highlights and describes the application of a new combustion management system using TDLS technology that has the ability to simultaneously control air and fuel supply to fired heaters by measuring average gas concentrations across the high 43

Figure 1. Diagram of a typical fired heater. Table 1. Features and benefits of TDLS technology Feature In situ analysis Benefit Sample conditioning not required Fast response Real time data for control Tunable laser Interference free analysis Non-contact sensor Suitable for operations in harsh environments Optical sensor Low maintenance Source: ARC Insights, Insight# 2009-50MP, November 2009 temperature radiant section. Reliable measurements of cross sectional averages of O 2 and CO at high temperatures have only recently become viable with the introduction of TDLS technology. The solution described in this article unites a TDLS analyser with a dedicated control system and a safety system certified to meet FM NFPA and SIL 2 standards. The intrinsic value gained by adopting this new combustion technology can be summarised by the following: n Best industry practices which can only be satisfied with new technology. n Increased safety because both air and fuel are continuously controlled. n Improved thermal efficiency as excess air is always optimised. n Longer fired heater life (asset reliability) since heat is not concentrated at the bottom of the convection section. n Lower greenhouse gas emissions through more efficient use of fuel. Managing combustion in natural draft fired heaters The air supply for most fired heaters is natural draught, not forced air, and these heaters typically lack the degree of automation normally applied to other process units in the plant. Natural draught fired heaters, as the name implies, use flue gas buoyancy to support combustion. These heaters can be either cylindrical or box type (Figure 1). The buoyancy of the flue gas (combustion product) relative to the surrounding air is determined by the product of the average density of the flue gas and the height of the heater. Furnaces are designed to run at a pressure of -12 to -25 Pa at the top of the radiant section, whether a heater is natural draught, induced draught or forced draught. Figure 1 provides a simplified diagram of a typical fired heater. The low level of control on most fired heaters is due, at least in part, to the historical lack of reliable, effective instrumentation and automation technology to simultaneously measure and control the fuel, gas concentrations, and the air/fuel ratio. An O 2 sensor is typically required at the stack base for thermal efficiency calculations, which require total excess air. While operators attempt to maintain excess O 2 in the furnace for safety, the amount indicated from an existing sensor may be incorrect due to tramp air. In fact, it is possible that the burners may be starved of air, despite excess oxygen at the stack base. Because of the lack of air control, in practice operators will typically allow excess air into the fired heater, reducing its thermal efficiency. The lack of effective instrumentation to continuously and rapidly measure O 2 and CO in the combustion chamber of the fired heater introduces considerable safety risk. Apart from the simultaneous control of fuel and air concentrations, it is possible for fuel rich conditions to arise, which increases the potential explosion risk. Note that under fuel rich conditions, temperature/fuel controllers no longer work properly. The detection of combustibles, primarily CH 4, in the radiant section of the fired heater is recommended by the American Petroleum Institute in API 556: a recommended practice for Instrumentation, control and protective systems for fired heaters and steam generators that specifically applies to gas fired heaters and steam generators in petroleum refinery, hydrocarbon processing, petrochemical and chemical plants. However, traditional analyser technology cannot be installed in the radiant section due to the high temperatures. As noted above, without accurate measurements of CH 4, O 2 and CO concentrations, operators tend to allow more air than is necessary in the heater, reducing its thermal efficiency. To properly control the combustion air, CH 4 and CO must be measured at the top of the radiant section where combustion is completed, regardless of the burner loading. Note that O 2 and CO will coexist within the flames, where the temperature may be as high as 1200 C. Low NO X burners may use delayed completion of combustion through staged air/fuel mixing, or external recirculation of cooler flue gas with combustion air, reducing peak flame 44

heater. Fired heaters have two principal unsafe operating conditions that must be avoided: n Fuel rich, where air is reduced. CO will be produced by the burners and excess O 2 will be lower, which results in excess fuel from the burners n Flame out, where loss of flame results in rapid loss of gas temperature. O 2 levels are high as burner air is not reduced by combustion, and uncombusted fuel is present. Figure 2. TDLS technology for combustion safety and optimisation. Figure 3. Basic functional capabilities of Yokogawa s CombustionONE integrated TDLS system. temperature. In either case, to effectively control the combustion process it is essential to measure O 2 and CO at the top of the radiant section, ideally 1 ft below the roof tubes where combustion reaction is expected to complete under all heater operating loading conditions. Using the TDLS in concert with a dedicated controller, a cross sectional average O 2 and CO density rather than a localised spot measurement can be measured to determine the right air/fuel ratio. Using an average O 2 value and CO limit value produces safer burner control and greater overall heater efficiency. Table 1 lists the features and benefits of TDLS technology, which has distinct advantages over single point in situ analysers that may give false readings because of varying gas concentrations at different locations in the fired Consequently, continually measuring the percentage of O 2 is critical to improving heater efficiency and to maintaining safe operating conditions. When firebox conditions are unacceptable, i.e. high levels of CO or combustibles exist, the effective combustion management solution must rapidly detect the condition and initiate the appropriate response. In the system being described, the embedded control and safety systems will ensure that these conditions are avoided or that combustion is extinguished and fuel flow is interrupted automatically if these conditions are detected. The TDLS analyser technology will reliably respond to all O 2 events in situations where conventional sensor technology would miss most of them. How it works Capable of measuring the average gas concentration across the radiant zone of the fired heater, the TDLS system addresses both the above less than optimum conditions by simultaneously controlling the fuel and air (O 2 ) supply based on fast (typically less than five second) sample intervals. Measuring the gas concentration in the radiant zone is also a requirement of API 556. Measurements from the system include CO, CH 4, O 2, and temperature. Using an average gas concentration produces safer burner control and greater overall heater efficiency. By optimising air flow control, O 2 concentration is typically reduced from 6% to 2%, increasing thermal efficiency of the furnace. The combustion management system manages fuel flow and arch draft through the existing plant DCS via Modbus, while combustion airflow is controlled directly with the CO override function. The simplified architecture diagram in Figure 3 illustrates the key components comprising the solution. Because the TDLS is a non-contacting measurement, never touching the flue gas, and has no moving parts, the whole system enjoys very high reliability. This TDLS analyser technology has been operational on furnaces since 2003 without incident, and most of those units have not required calibration. The analyser has full diagnostic capability, and if there is an issue it will alert the operator. Moreover, the 45

Figure 4. Hardware included in the CombustionONE TDLS system: 1) dedicated controller; 2) sensing and actuation; 3) safety interlock system; 4) tunable diode laser spectrometer. measurement signals from the TDLS are unaffected by the presence of other gases in the flue gas, unlike sensor based systems. The TDLS uses a path average measurement, as opposed to the traditional point measurement, making the value of concentration much more accurate. Refinery application The most critical times of heater operation are at start up and shutdown. Recognising that a much faster, more reliable analyser is required to measure O 2, CO and CH 4 concentrations, a European refining operation has adopted the TDLS solution for combustion management. Since the system measures gas concentration in the radiant section of the fired heater, it is expected to improve heater safety and overall operational efficiency. In this application, the system is installed with two TDLS analysers for measurement of O 2, CO and CH 4 concentrations in the radiant section of the heater. A dedicated controller uses these measurements while feeding these values to an existing DCS for monitoring and future control of the heaters. The dedicated control hardware is equipped to receive additional signals from the heater, which will be used to control the airflow in the burners in a subsequent phase of the project. Space has also been allotted for a future safety shutdown system. The system is designed to be tested during upset conditions, with the response of combustion gases being analysed to confirm the desired response to unsafe conditions. This data can then be correlated to the output from the existing stack gas analyser to verify the results. Data collected during this testing will be incorporated into the future safety shutdown system. A modular procedural automation capability will enforce safe operating conditions during start up and shutdown. Once the safety interlock system is in place, the system will be able to detect and prevent any unsafe operating conditions. Natural draught heaters lack the capability to use air to purge the heater. Instead, steam is used. If the steam is not dry, water will accumulate on the burners or igniters, preventing ignition. The start up sequence is designed to purge the condensate from the steam line, thus providing dry steam to purge the heater before ignition. The system has been operational in the refinery since June 2010, and the TDLS analysers continue to operate reliably with no maintenance needed. The operators have been able to reduce the percentage of O 2 by 1% to 1.5%, thus making the heater more efficient. The furnace is now near its optimum operating point, using minimum excess air. The TDLS measurements have been verified by the existing stack gas analysers, but with a percentage O 2 reading of 1% to 1.5% lower than the stack gas analysis because the measurements are taken in the radiant section. Furnace conditions can now be controlled (or shut down) quicker since the TDLS system is taking concentration measurements at five second intervals in the radiant section. If there were to be an excess concentration of CO or CH 4 in the furnace, these gases can be detected earlier than with the conventional stack gas analyser, enabling the heater to be shut down sooner and avoiding unsafe conditions. Integrated solution The combustion management system described in this article (Figure 4) is an integrated, self contained system that can be rapidly installed on any fired heater. It comprises four principal components: n TDLS technology for gas concentration measurements at fast (less than five second) intervals. n A dedicated system for control of fuel and air value and ratio based on a fired heater model with CO override function. n An OSHA compliant safety system to prevent unsafe conditions from persisting. n Sensing and actuation for additional measurements and air flow control as needed. Two TDLS systems (transmitters and receivers) are typically installed in the radiant section of the fired heater, which is the most accurate location for optimum combustion management. At minimum, one unit measures O 2 and the other CO and CH 4. Since fired heaters have differing configurations, capacities, environmental and process conditions, custom mounting brackets are built to hold and position the laser across the radiant section. This is the best location to obtain the most accurate gas concentration and temperature measurements. The dedicated controller is used to simultaneously control fuel and air volumes based on five second sampling measurements of average gas concentrations across the radiant section from the TDLS. Since the combustion management solution is completely self contained and requires little integration with existing control systems and instrumentation, installation is typically straightforward. 46