Refrigerant Installation Quick Reference Guide

Similar documents
14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

OPERATING INSTRUCTIONS

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Refrigerant Recovery Unit, Model RRU134

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

OPERATION & MAINTENANCE MANUAL TX600

Refrigerant Recovery Machine. Model No Operating Manual

OPERATING INSTRUCTIONS

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Additional users operating manual

MASS. MARITIME ACADEMY

OPERATION & MAINTENANCE MANUAL TC670

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Climate Control System

High Output Vacuum/Pressure Pump

1998 Expedition/Navigator Workshop Manual

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

Residential Piping and Long Line Guideline

R100 Oil-Less Refrigerant Recovery Unit

B. A. T. Basic Appliance Training

Refrigerant changeover guidelines

OPER LV Wheeler Way

Energy Use in Refrigeration Systems

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL AC860

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

OWNER S MANUAL (English)

6. Within an internal combustion engine, the can-shaped component that moves up and down the cylinder

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

XC13. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.

Ariazone 601HD Refrigerant Recovery&Recycling unit

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

OPERATING INSTRUCTIONS

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below:

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS

R-407A R-448A R-449A

SECTION 50 - CAB CLIMATE CONTROL

The complete approach to the care and management of A/C & refrigeration systems

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

HEATING AND AIR CONDITIONING

USING THE P-T CARD AS A SERVICE TOOL

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

R-290 SERVICE MANUAL SWF MODELS. Principals and Best Practices for servicing HC refrigeration equipment

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

MECHANICAL SCIENCE Module 2 Heat Exchangers

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

The Use of Solvents in Laboratory Freeze Dryers A Discussion of Issues and Some Helpful Tips

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Use this Construction/HVAC Glossary to answer the questions below.

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

Refrigeration Manual. Part 1 - Fundamentals of Refrigeration

Installation Instructions

Air Conditioning Repairs: Maintenance Required

User s Information and Installation Instructions

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Caresaver Universal Refrigerant Recovery Unit

EXHIBIT G REFRIGERANT MANAGEMENT POLICY

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

OWNER S MANUAL (English)

A/C COMPRESSOR OIL CHECKING

Installation Instructions

Condensing Unit Installation and Operating Instructions

MC Series Gas-Fired Heating Appliance

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

Part IV: Flow Side Components Flow Diagram

HP13 WARNING WARNING. Service Literature HP13 SERIES UNITS

Series 6, Vertical Floor-Mount Units

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

Often fellow technicians, co-workers and field personnel CHARGE REFRIGERANT DETERMINING PROPER SYSTEM

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Transcription:

Refrigerant Installation Quick Reference Guide To be used only by experienced and licensed refrigeration technicians Preface: This project objective is to replace existing CFC or HCFC refrigerants with all-natural Priority Cool hydrocarbon refrigerants. This Reference Guide includes recommended procedures for the installation of Priority Cool hydrocarbon refrigerants, and is to be used only by qualified licensed refrigeration technicians trained in the safe handling of flammable gasses and materials. Failure to adhere to these procedures or intentional misuse may result in serious injury or death. Before You Begin: Leak Test: Prior to installing Priority Cool hydrocarbon refrigerants if there is any evidence or history of refrigerant leaks, it is imperative that the entire system be pressurized with dry nitrogen to a minimum of 1-1/2 times the high side working pressure. Any leaks found MUST BE REPAIRED before Priority Cool hydrocarbon refrigerant is installed. In addition, any inoperative components MUST BE REPLACED. Pay particular attention to safety and operating controls. System Pressures: Priority Cool hydrocarbon refrigerants operate at lower pressures on both high and low sides. Failure to consult the temperature/pressure chart may result in equipment damage and/or poor performance. System Charge: The amount of Priority Cool hydrocarbon refrigerant will be approximately 40% less than the CFC refrigerant removed. DO NOT replace CFC or HCFC refrigerants with Priority Cool hydrocarbon refrigerants in equal weight or equipment damage and/or poor performance may result. Equipment Loading: It is necessary to ensure the equipment is operating with the correct volume of air or water is entering the evaporator and condenser, and they should be cleaned if necessary. Fan belts must be checked and adjusted so that correct pressure and temperature drops are maintained. Steps in Replacing Existing CFC or HCFC Refrigerants: STEP 1: While system is operating check and record compressor amperage or wattage (all phases), suction and discharge pressures, condenser air temperature in and out (if air-cooled), condenser water temperature in and out (if water-cooled), evaporator temperature in and out, ambient temperature. Priority Cool Quick Reference Guide Rev. 03-2015 Page 1

STEP 2: Disconnect all electrical power to system. Recover the existing refrigerant into a suitable recovery tank is strict accordance with current EPA requirements and regulations, (40 CFR Part 82, Subpart F). Place the empty recovery tank onto an electronic scale and weigh it. Then recover the existing refrigerant and accurately weigh it. Record the amount of refrigerant recovered to the ounce. STEP 3: Pressurize the system with dry nitrogen to a minimum of 1-1/2 times the working high side pressure. Perform leak check while system is under pressure. Repair any leaks before proceeding. Note: if the refrigeration system contains a relief valve, ensure the nitrogen pressure does not exceed the relief valve pressure setting. STEP 4: Evacuate and dehydrate the system using guidelines and procedures below entitled Fundamentals of Dehydrating a Refrigerant System. For reasons stated below it is imperative that these guidelines are followed to ensure that all moisture is removed from the system and the compressor refrigeration oil. As in all refrigeration systems moisture will adversely affect performance and may lead to compressor failure. Leaving the system in a deep vacuum with the vacuum pump disconnected for a period of time with no loss of vacuum will ensure that the system is tight. Holding a deep vacuum is the best way to determine the system is leak-free. STEP 3: After you have determined that the system is free of leaks and has been dehydrated, following the guidelines below, and with system electrical power disconnected, slowly introduce the proper Priority Cool hydrocarbon refrigerant into the system. Priority Cool refrigerants must be added to the equipment as a liquid, not a gas. The initial charge should be approximately 35% (by weight) of the refrigerant recovered. This will ensure the proper charge and peak efficiency of the equipment. The final adjustment to the charge should be made while the compressor is running. STEP 4: Restore electrical power and start the system. Carefully observe operating pressures and temperatures. Adjustments to the initial Priority Cool hydrocarbon refrigerant charge should be made at this time. A suitable amount of time (at least 30 minutes) should be allowed for the system to stabilize. The proper charge is determined by suction pressures and leaving air (or water) temperatures. STEP 5: After the system is performing at optimum pressures and temperatures, check and record compressor amperage (all phases), suction and discharge pressures, condenser air temperature in and out (if aircooled), condenser water temperature in and out (if water-cooled), evaporator temperature in and out, ambient temperature. Compare these readings to those recorded at the onset. Step 6: Attach an Attention Tag to the equipment charging ports that future technicians are aware that the system contains a Priority Cool refrigerant. We recommend using the Attention Tags shown on the last page of this Guideline. These tags are shipped with each cylinder of Priority Cool refrigerant. Please use them. Priority Cool Quick Reference Guide Rev. 03-2015 Page 2

Fundamentals of Dehydrating a Refrigerant System The two most frequent questions service technicians ask about dehydration are: 1) What size vacuum pump should be used to perform a good refrigeration/air conditioning system dehydration job? 2) How long should the pump be left on the system to assure removal of all moisture? To give specific answers to these questions, you need to know the cubic capacity of the system to be dehydrated; amount of moisture both visible and invisible present in the system; I.D. and length of the connecting line as well as the restrictions within the system itself (cap tubes, valves, etc.) which might cause back pressures. Rather than supplying fast, pat answers to these important questions and then trying to justify them, let's start by covering the basic fundamentals of dehydrating a refrigerant system. Moisture in a Refrigerant System Effects of Pressure and Temperatures on the Boiling Points of Water High Vacuum / Deep Vacuum Gas Ballast or Vented Exhaust Vacuum Pumps Factors Affecting the Speed at which a Pump Can Hydrate a Refrigerant System Moisture In A Refrigerant System While it is important to realize that moisture in a refrigerant system is the underlying cause of most problems and complaints, it is equally important to learn why. Basically, moisture can be classified as visible and invisible. Occasionally, liquid water is found in systems, but this is unusual. Invisible moisture, or water vapor, is the culprit which causes the greatest trouble in refrigeration and air conditioning systems. A single drop of water may look harmless, but to a refrigerant system, it is a monster, the number one enemy of service technicians. What makes it so formidable is the fact that moisture enters a system easily and is hard to remove. Here is what it does to a system: First, it creates "freeze-ups." Moisture will be picked up by the refrigerant and be transported through refrigerant lines in a fine mist which forms ice crystals at the point of expansion. Ice crystals retard or stop the flow of the refrigerant, causing loss of cooling. As the expansion valve warms, due to the lack of refrigerant, the ice melts and passes through the expansion valve. The refrigerant will then start again until the moisture returns to the expansion valve and once more builds ice crystals. The result is intermittent cooling. Priority Cool Quick Reference Guide Rev. 03-2015 Page 3

Whether a "freeze-up" actually occurs depends primarily upon the amount of water and the size of the ice particles formed. But, a "freeze-up" is not the only problem caused by moisture. It can also cause corrosion, which can present serious trouble. Moisture in the form of water can cause corrosion after a period of time. However, moisture mixed with refrigerant creates much more corrosion trouble. Refrigerant such as R-12, containing chlorine, will slowly hydrolyze with water and form hydrochloric acids. This acid greatly increases the corrosion of metals and could corrode copper plating, and destroy compressor motor windings leading to a burn out. Heat increases the rate of corrosion due to acids because higher temperatures accelerate the acid-forming process. This acid attacks all the materials it contacts. Refrigerant oil presents another problem caused by moisture. Refrigerant oil is an exception to the rule that "oil and water don't mix." In fact, refrigerant oil attracts moisture and will absorb it rapidly if left open to the atmosphere. Water-formed acid mixes with refrigerant oil, forming a closely bonded mixture of fine globules. The effect is called "sludging" and greatly reduces the oil's lubricating ability. Corrosion becomes troublesome from the operating standpoint when metallic surfaces are eaten away and a solid, detachable product is formed. This formation is also known as a "sludge." Sludge can cause a variety of problems. It will plug fine strainers, expansion valves and capillary tubes. And because it usually contains acids, sludge corrodes whatever it clings to, accelerating system damage. The most effective way to eliminate moisture from a system is with a good, high vacuum pump. Effects Of Pressure and Temperature on the Boiling Points of Water A high vacuum pump is capable of removing all moisture from a hermetic system by reducing internal system pressures to the boiling point of water at normal temperatures. For those being introduced here to high vacuum work, it should be stated that a vacuum pump does not "suck out" the liquid moisture, but rather causes it to boil in to a vapor state which can be harmlessly removed from the system and exhausted through the vacuum pump. The planet Earth is surrounded by matter in a gaseous state composed of about 78% nitrogen, 21% oxygen and 1% a mix of water vapor and other trace gases. Together they form our atmosphere, which extends approximately 600 miles above the earth and is held to the earth by gravity. Being a gas, the atmosphere has weight, and that weight is measured, as in any fluid Priority Cool Quick Reference Guide Rev. 03-2015 Page 4

whether liquid or gas, in pounds per square inch (psi). If you were to take a square inch column of the air extending six hundred miles above the earth, its weight and pressure exerted on the earth at sea level would be 14.7 lbs. This is called atmospheric pressure. Any pressure above atmospheric pressure is referred to as gauge pressure. Pressures below are referred to as vacuum. This same square inch column of air exerting 14.7 psi can support a one-inch square column of mercury (Hg) 29.92 inches high. This concept can best be understood by comparing it to a teetertotter. When a one square inch column of Hg 29.92" high is placed on one end of the teeter-totter, and a 14.7 lb weight on the other end, the board will be balanced. Atmospheric pressure decreases at higher elevations. As stated, 600 miles of atmosphere at sea level is equivalent to 14.7 psi and/or 29.92 inch column of mercury (Hg). Going above sea level, to the summit of Mt. Whitney, for example, eliminates some of the 600 miles of atmosphere and, consequently, some of the pressure. Atmospheric pressure, therefore, governs the boiling point of water. At sea level, where atmospheric pressure is 14.7 psi (29.92" Hg), water boils at 212 F, but on Mt. Whitney, where atmospheric pressure is 8.32 psi (16.9: Hg), water boils at 184 F. The lower the atmospheric pressure is, the lower the boiling point of water. Therefore, if we can significantly reduce the atmospheric pressure inside a sealed refrigerant system, we can vaporize (or boil) moisture at even 90 F. This principle is illustrated in the chart below. Two ways exist to eliminate moisture from a refrigerant system by the boiling process: 1. Apply heat to the system causing the moisture to boil. 2. Employ a high vacuum pump to reduce the pressure and boiling point of water. The first method is obviously impractical, so a high vacuum pump is the key! Priority Cool Quick Reference Guide Rev. 03-2015 Page 5

High Vacuum/Deep Vacuum As illustrated above, the purpose of a vacuum pump is to reduce the internal system pressure of a refrigeration/air conditioning system so moisture and other contaminants can be removed. The term "high vacuum" describes a condition where the internal system pressure is extremely low, or close to a perfect vacuum. The higher the vacuum is in a system, the closer the micron reading is to 0 microns. Deep vacuum can be thought of in the same way. The deeper a vacuum is, the closer the micron reading is to 0 microns. "High vacuum" and "deep vacuum" describe the same condition inside a closed system. For refrigeration/air conditioning service applications, high vacuum = good vacuum, or a low micron depending on the system. Priority Cool Quick Reference Guide Rev. 03-2015 Page 6

Selecting High Vacuum Pumps To make the following discussion easier to understand, it would be best from this point on to think of pressure (psi) as the amount of mercury it will support, e.g. atmospheric pressure at 29.92" Hg instead of 14.7 psi. This will permit us to use Chart II as a visual aid when determining the vacuum which must be attained to boil water under various ambient temperatures. Chart II shows a vacuum pump capable of eliminating all but one inch of mercury. It is able to remove moisture at an ambient temperature of 80 degrees F or over. While any pump pulling within one inch of atmospheric pressure can eliminate moisture, it must also be capable of holding that vacuum throughout the dehydration process. In addition, it must pull that vacuum on the entire system and not simply at the intake of the pump. Gas Ballast (Vented Exhaust) Pumps The gas ballast or vented exhaust feature on some vacuum pumps permits relatively dry air from the atmosphere to enter the second stage of the pump. This air reduces the compression in the final stage, which helps to prevent moisture from condensing into a liquid and mixing with the vacuum pump oil. Here's a comparison to show how it works: Imagine a damp towel being twisted until water drops out. This can be compared to a high vacuum pump which is not equipped with a gas ballast. Moisture being pulled from a wet refrigerant system is compressed internally in the vacuum pump and condenses into a liquid. Now imagine the same damp towel entwined with a dry towel and then twisted. It would take a considerable amount of twisting before any water would drop out. Thus the process of the gas ballast arrangement permits the moisture-laden air passing through the pump to mix with relatively dry air to such a degree that compression does not cause condensation. The damp towel comparison also illustrates why this valving feature cannot handle large amounts of moisture. If the towel is almost saturated with water, even the introduction of the completely dry towel will not prevent some of the water from dropping out when the two are compressed. Because of this, some pumps are designed to run with both high internal temperatures (to reduce moisture condensation in the oil) and a gas ballast. Due to the "severe" application of a vacuum pump when used to "boil water," it is necessary to select a quality two-stage model equipped with a gas ballast and high internal running temperature to achieve adequate performance over a long period of time. However, even the best pump must have regular maintenance to perform optimally. Priority Cool Quick Reference Guide Rev. 03-2015 Page 7

Frequent oil changes should be anticipated and considered as the single most important factor in a preventative maintenance program. Remember, even a pump equipped with a gas ballast cannot handle large amounts of moisture without some being condensed into the oil. If allowed to remain inside the pump, this moisture will result in lock ups or loss of efficiency and/or capacity. Normally, oil changes will not be required during a single dehydration job. But it would be well to change oil after each major pump down. This is especially critical when pumping down a system known to be wet or experiencing a compressor burn out. Factors Affecting The Speed At Which A Pump Can Dehydrate A Refrigerant System Several factors influence the "pumping speed" of a high vacuum pump, and thus the time required to remove all moisture from a refrigerant system. Some of the most important are: the cubic feet of the system; the amount of moisture contained within the system; the ambient temperature present; internal restrictions within the system; external restrictions between the system and the vacuum source; and the size of the pump. The only factors under the control of the service technician are the external restrictions between the system and the vacuum pump. Let us assume that all other variable factors affecting pump down time are equal within a system. Variable pressures within a system attempt to equalize one another. The higher pressure "flows" toward the lower pressure. The above illustration shows the variable pressure creating a vacuum of 100 microns and the system at higher atmospheric pressure. The higher pressure in the system will flow toward the vacuum pump until it is reduced or equal to the 100 microns of pressure. The speed at which it will flow is controlled by the I.D. and length of the connecting line. Laboratory tests show that pump down time can be significantly reduced by use of larger diameter hoses. For optimum pumping speed, keep access lines as short in length and as large in diameter as possible. All of us have released an inflated balloon, allowing the escaping air pressure to propel it on a wild course. At other times you have inflated a balloon and stretched its stem, allowing the air to escape with a squealing sound. In effect, you were controlling the connecting I.D. as in the above illustration and, in turn, controlling the time it took to release all of its pressure. The principal is identical the higher pressure is trying to move toward the lower pressure. These illustrations stress the importance of eliminating all external restrictions whenever possible. Priority Cool Quick Reference Guide Rev. 03-2015 Page 8

In answer to our first question, it is perfectly acceptable to use a 4 CFM or larger vacuum pump on a small system. Using too small of a pump on a large system, e.g. a 1.2 CFM vacuum pump on a 40 ton unit, could cause the pump to operate in a "free air" condition for an extended period of time, thus risking premature pump wear. To answer our second question, the best way to know for sure that the system has been thoroughly dehydrated is by using a thermistor vacuum gauge. This prevents wasting time by pulling down after evacuation is complete or risking inadequate dehydration. When reading vacuum, remember that the location of the gauge tube will affect the reading. The closer the gauge is to the vacuum pump, the lower the reading will be. To get the most reliable reading, isolate the vacuum pump using a vacuum valve assembly. Let the pressure to equalize throughout the system, then take a final reading. in.hg Vacuum Evacuation Pressures P.S.I.A. Microns mm Hg Boiling Point of Water ( F) 0.00 14.696 759,966 760 212 4.92 12.279 653,000 653 205 9.23 10.162 525,525 526 194 15.94 6.866 355,090 355 176 20.72 4.519 233,680 234 158 24.04 2.888 149,352 149 140 25.00 2.383 123,217 123 132 26.13 1.788 92,455 92 122 27.75 1.066 55,118 55 104 28.67 0.614 31,750 32 86 28.92 0.491 25,400 25 80 29.02 0.442 22,860 23 76 29.12 0.393 20,320 20 72 29.22 0.344 17,780 18 69 29.32 0.295 15,240 15 64 29.42 0.246 12,700 13 59 20.52 0.196 10,160 10 58 29.62 0.147 7,620 8 45 29.74 0.088 4,571 5 32 29.82 0.049 2,540 3 21 29.87 0.0245 1,270 1 6 29.91 0.0049 254 0.25-24 29.915 0.00245 127 0.13-35 29.919 0.00049 25.4 0.025-60 29.9195 0.00024 12.7 0.013-70 29.9199 0.000049 2.54 0.003-90 29.9200 0.000000 0.00 0.000 --- Priority Cool Quick Reference Guide Rev. 03-2015 Page 9

Important: Upon completion of the refrigerant installation install identification tags like those illustrated below be installed on all unit charging ports to alert all service technician that a hydrocarbon refrigerant has been installed. Priority Cool Quick Reference Guide Rev. 03-2015 Page 10