Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a

Similar documents
PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CHAPTER 1 INTRODUCTION

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

CHAPTER 1 INTRODUCTION

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Design of LPG Refrigeration System

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

A Comparison Between Refrigerants Used In Air Conditioning

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

DEEPAK PALIWAL, S.P.S.RAJPUT

η second law = Second law efficiency

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Department of MCE, Islamic University of Technology 2. Abstract

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Chapter 10. Refrigeration and Heat Pump Systems

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Thermodynamics II Chapter 5 Refrigeration

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Thermodynamics I. Refrigeration and Heat Pump Cycles

Experimental Performance Evaluation Of Vapour Compression Refrigeration System using R134a and R152a Refrigerants, A review

Sarthak Thakar, 2 R.P.Prajapati 1

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

JJMIE Jordan Journal of Mechanical and Industrial Engineering

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Chapter 2. Alternatives to HCFCs and their Characteristics

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Oyelami S., Bolaji B. O.

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

International Journal of Advance Engineering and Research Development

PERFORMANCE ANALYSIS OF A DOMESTIC REFRIGERATOR USING VARIOUS ALTERNATIVE REFFRIGERANT

Study of R161 Refrigerant for Residential Airconditioning

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

Design and Analysis of Water Cooled Condenser

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Review of Current Automobile Refrigeration System on Basis of Refrigerants Used & Their Impact on Global Warming Potential.

Evaluation of COP in Refrigeration System by using Different Refrigerants

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

Chapter 11 REFRIGERATION CYCLES

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Transcription:

ISSN 2395-1621 Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a #1 Shrikant Dhavale, #2 Manish Deshmukh 1 dhavaleshrikant5@gmail.com 2 msdngp@gmail.com #1 Department of Mechanical Engineering, SPPU,Pune JSPM s Rajarshi Shahu College of Engineering, Tathawade,Pune. #2 JSPM s Rajarshi Shahu College of Engineering, Tathawade. Pune,India ABSTRACT The continuous increase in the cost and demand for energy has led to more research and development to utilize available energy resources efficiently. Vapour compression refrigeration method is an efficient method of refrigeration among the different methods, but the energy inputs to the Vapour compression system is high grade energy. This study focuses on an experimental study of hydrocarbon blend of isobutane (R- 600a) and propane (R-290) as an environment friendly refrigerators with zero ozone depletion potential (ODP) and very low global warming potential (GWP), to replace conventional refrigerators tetrafluoroethane R-134a in a domestic refrigerators. The performance is observed for a domestic refrigerator by using blend of hydrocarbon R- 600a and R-290 and its performance is compared with R-134a without change in original system. Due to the higher value of latent heat of hydrocarbons the amount of refrigerant charge required found to be reduced as compared with hydrofluorocarbon R-134a. Comparative performance study shows refrigerating effect is improved by using hydrocarbon blends, reduction of 40% in the refrigerant charge, the energy consumption per day reduced by 5%. ARTICLE INFO Article History Received :18 th November 2015 Received in revised form : 19 th November 2015 Accepted : 21 st November, 2015 Published online : 22 nd November 2015 Keywords coefficient of performance COP, hydrocarbon, isobutane R600a, propane R290, R134a. I. INTRODUCTION The most commonly used refrigerants in the early 1900s were natural refrigerants such as ammonia, carbon dioxide, sulphur dioxide and methyl chloride. All these refrigerants were found to be toxic or hazardous. In 1928, a safer class of alternative refrigerants became available with the invention of chlorofluorocarbons (CFCs) and hydro chlorofluorocarbons (HCFCs). CFCs and HCFCs have many suitable properties such as stability, non toxicity, non flammable, good material compatibility and good thermodynamic properties, which led to their common wide spread use by both consumers and industries around the globe, especially as refrigerants in air conditioning and refrigeration systems. Results from many researches show that ozone layer is being depleted due to the presence of chlorine in the stratosphere. The general consensus for the cause of this is that CFCs and HCFCs are large class of chlorine containing chemicals, which migrate to the stratosphere where they react with ozone. Later, chlorine atoms continue to convert more ozone to oxygen. The discovery of the depletion of the earth s ozone layer, which shields the earth s surface from UV radiation, has resulted in a series of international treaties demanding a gradual phase out of halogenated fluids. The CFCs have been banned in developed countries since 1996, and in 2030, producing and using of CFCs will be prohibited completely in the entire world. Also, the partially halogenated HCFCs are bound to be prohibited in the near future. The researches are going on to find out some alternate refrigerants which does not harm to the environment and the protective ozone 2015, IERJ All Rights Reserved Page 1

layer. Research has shown that hydrocarbons are good alternative to existing refrigerants. Ref. No. Formul ρl ρv a (kg/m3) (kg/m3) Isobutane R600a CH (CH3) 3 530 13.667 Propane R290 CH3 467.07 30.202 CH2 CH3 Propene R1270 CH2=CH 476.66 35.708 CH3 R134a R134a CF3 1146.7 50.085 CH2F R22 R22 CHClF2 1128.5 66.193 Ammonia R717 NH3 579.44 12.034 II. LITERATURE REVIEW Moo-Yeon Lee, Dong-Yeon Lee, Yongchan Kim[1] In this study, the performance of a small-capacity directly cooled refrigerator was evaluated by using the mixture of R290 and R600a with mass fraction of 55:45 as an alternative to R134a. The compressor displacement volume of the alternative system with R290/R600a (55/45) was modified from that of the original system with R134a to match the refrigerationcapacity. Both systems with R290/R600a (55/45) and R134a were tested, and then optimized by varying the refrigerant charge and capillary tube length under experimental conditions for both the pulldown test and the power consumption test. The refrigerant charge of the optimized R290/R600a system was approximately 50% of that of the optimized R134a system. The capillary tube lengths for each evaporator in the optimized R290/R600a system were 500mm longer than those in the optimized R134a system. The power consumption of the optimized R134a system was 12.3% higher than that of the optimized R290/R600a system. The cooling speed of the optimized R290/R600a (55/45) system at the in-case setting temperature of _15 _C was improved by 28.8% over that of the optimized R134a system. Gaurav, Raj Kumar [2] This study presents a comparison of energy and exergy analysis for R134a, R152a, R290, R600 and R600a in refrigerator. The paper analyzes the domestic refrigerator with alternative refrigerants for computing coefficient of performance, exergy destruction ratio, exergy efficiency and efficiency defect. The method of exergy provides a measure to judge the magnitude of energy waste in relation to the energy supplied or transformed in the total plant and in the component being analyzed, a measure for the quality (or usefulness) of energy from the thermodynamic viewpoint and a variable to define rational efficiencies for energy systems. It is established that in the present work efficiency defect is maximum in condenser and lowest in evaporator. Comparison of various properties for alternative refrigerants has been done for a domestic refrigerator. Mohd. Aasim Nazeer Ahmad Quraishi, 1 U. S.Wankhede [3], this paper presents a study of different environmental friendly refrigerants of either hydrocarbon or Hydro fluoro carbons (HFC) class. Hydrocarbons (HCs) have zero ODP and very low GWP whereas HFCs have zero ODP but a quite higher GWP. Almost in all the cases, when R-134a was replaced with HCs the COP of the system was improved, ON time ratio and energy consumption was reduced. Due to a higher value of latent heat of HCs, the amount of refrigerant charge was also reduced as compared with HFC-134a. When hydro chlorofluorocarbons (HCFCs) were replaced with HFCs the system delivered a poor performance with increased energy consumption. When nano particles were added to the refrigerant, system delivered better performance with reduced energy consumption than that of pure refrigerant. Rajanikant Y. Mahajan 1, Sanjaykumar A. Borikar [4], this paper presents a study of different environment friendly refrigerants with zero ozone depletion potential (ODP) and negligible global warming potential (GWP), to replace R134a in domestic refrigerator. This work consists of using a hydrocarbon gas mixture which does not deplete ozone layer, is eco friendly, and can be used in the commonly used refrigerators without any significant change in the system. A refrigerator designed and developed to work with R134a was tested, and its performance using HC-12a was evaluated and compared with its performance when R134a was used. The condenser temperature and evaporator temperature, COP, refrigerating effect, condenser duty, work of compression and heat rejection of water were investigated. The energy consumption of the refrigerator during experiment with hydrocarbons and R-134a was measured. The results obtained showed that the alternative refrigerant investigated in experimental performance HC-12a have higher coefficient of performance and less energy consumption. The design temperature and pull-down time set by International Standard Organization (ISO) for small refrigerator were achieved earlier using refrigerant HC-12a than using R-134a. Due to a higher value of latent heat of HCs, the amount of refrigerant charge was also reduced as compared with HFC-134a. The COP and other result obtain in this experiment shows a positive indication of using mixed refrigerant as refrigerants in household refrigerator. The performance of HC-12a in the domestic refrigerator was constantly better than those of R134a throughout all the operating conditions, which shows that HC-12a can be used as replacement for R134a in domestic refrigerator. Refrigerant physical and chemical properties of different refrigerants are included in this paper. This paper also discuses on the C.O.P (coefficient of performance) and RE (Refrigeration Effect). Dr. A. G. Matani, Mukesh K. Agrawal [5], there are a large number of refrigerants, which are used to transfer heat from low temperature reservoir to high temperature reservoir by using vapour compression refrigeration system. In this paper, experimental study was conducted to observe the performance of different environmental friendly refrigerant mixtures (HC mixture and R401a). It was also observed the effect of working parameters like diameter of capillary tube, working pressures and inlet water temperatures, which affect the coefficient of performance (COP) of vapour compression refrigeration system. It was observed that R134a is more efficient than HC mixture and R401a, but there is less mass quantity of HC mixture and R401a is required in the same system. So there is less effect in environment due to leakage. 2015, IERJ All Rights Reserved Page 2

M. G. Almeida, C. R. F. Barbosa, and F. A. O. Fontes [6], The research efforts and development in the refrigeration and air conditioning sector applied to the use of natural refrigeration fluids is not associated only with the need to preserve the environment alone, but has great importance with regard to the latent need for energy efficient equipment. With this perspective, the present study deals with the thermodynamic evaluation of the use of hydrocarbons refrigerants in household refrigeration systems that utilize HFC134a as a working fluid. A theoretical-computational analysis was developed for R134a, propane (R290) and the selected mixtures (R290/R600a 60%/40% R290/R600a/R134a 40%/30%/30% and R600a/R290 50%/50%) in the standard refrigeration cycle ASHRAE, using the thermodynamic and thermophysical properties provided by the REFPROP 6.0 software. The results of computational simulations between the fluids were compared to find the evidence of the best alternative to HFC134a. In this sense, it was observed that the hydrocarbons reduced the levels of pressure on the condenser and evaporator, along with smaller compression tasks necessary in the system, owing to the thermo-physical properties privileged in these fluids. The use of these fluids is also proportionate to lower temperatures of compressor discharge, increasing the life of this highly valuable component of the system. P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan [7], In this analysis, the performance of compression cycle is assessed theoretically with different refrigerants. In compression refrigeration system, hydrocarbon refrigerants such as R290 and R600a are considered as a refrigerant by mixing of these at different mass fractions about 20%+80%, 25%+75%, 50%+50% and 75%+25% respectively. Various performance measures like compressor discharge temperature, pressure ratio, volumetric cooling capacity (VCC), volumetric efficiency and mass flow rate are analyzed. The results are compared with halogenated refrigerants such as R134a, R12 for different condenser and evaporator temperatures. Halogenated compounds are having direct environmental impacts in turns of ODP and GWP. Among the hydrocarbon refrigerants group, the mixture of R290 and R600a at concentration of 50% each has optimum performance in terms of higher refrigeration effect, better heat transfer and III. DESIGN AND DEVELOPMENT OF EXPERIMENTAL SET-UP This section provides a description of the facilities developed for conducting experimental work on a domestic refrigerator. The technique of charging and evacuation of the system is also discussed here. The experimental setup of the test unit and apparatus is shown in the Figure. Different experimental and theoretical comparison will performed to evaluate the performance of domestic refrigerator by using different refrigerants. In this experimental study of zeotropic blend of R600a and R290 (50/50)is compared with the R-134a in a domestic refrigeration system. To perform the experiment 40L refrigerator is selected which was designed to work with R- 134a. It is consists of an evaporator, air cooled condenser, expansion device and reciprocating compressor. The refrigerator was instrumented with two pressure gauges at inlet and outlet of the compressor. The temperature at six different points is taken by six temperature sensors are mounted to measure the compressor inlet temperature, compressor delivery temperature, evaporator inlet temperature, evaporator outlet temperature, the freezer temperature and cabinet temperature. An ammeter is mounted at the inlet of the compressor to measure the power supply and voltmeter is also used for voltage of supply. Firstly cleaning is done with the help of nitrogen gas then evacuation is carried out with the help of vacuum pump and refrigerant is charged with the help of charging system. The refrigerant charge requirement with hydrocarbons is very small due to their higher latent heat of vaporization. As per the refrigerator manufactures recommendation quantity of charge requirement for HFC134a was 500 g. In the experiment, refrigerant charge is 10% higher due to the presence of instruments and connecting lines etc. To optimize the zeotropic blend of R600a and R290 (50/50) refrigerant charge, the refrigerator is charged with 170g and the performance was studied. The experimental procedures were repeated and take the reading for different mixtures from the various modes. Fig. 1: Experimental Set-up Specification for Experimental Set-up: Water cooler CAJ34G (KCJ444HAG) Capacity (litres/hour): 40 Condenser size: 3/8 O.D. 10-12 FPI -11 10 3 Row Condenser fan motor: 1/36 H.P. 1350 RPM Condenser fan: 10 Diameter Evaporator tube: Size Length 3/8 O.D. 50 Capillary: Bore Length0.050 5 1 number HFC-134a commercial back pressure compressor Cooling capacity: 1720 Btu/hr 433 kcal/hr Rated Power and Current: 330 W and 2.34 A Displacement: 12.58 cc/rev Cooling type fan: 350 CFM Oil charge quantity: 890 cc Temperature range:-50 to + 80 C Humidity range for temp. Sensor :5% to 80% Accuracy: ±.1 C Distinguish: 0. 1 C Power :two button battery (LR44, 1.5v) B. Test Methodology: 2015, IERJ All Rights Reserved Page 3

Heat flows naturally from a hot to a colder body. In refrigeration system the opposite must occur i.e. heat flows from a cold to a hotter body. This is achieved by using a substance called a refrigerant, which absorbs heat and hence boils or evaporates at a low pressure to form a gas. This gas is then compressed to a higher pressure, such that it transfers the heat it has gained to ambient air or water and turns back (condenses) into a liquid. In this way heat is absorbed, or removed, from a low temperature source and transferred to a higher temperature sources. This is a basis of vapour compression cycle. Then zeotropic blend of R600a and R290 (50/50) called as care 30 is used under study for same set up 170 g of care 30 is charged in system. And same procedure is repeated for readings. C. Formulae Used: 1. The pressure ratio (PR) is defined as the ratio between the condensation pressure (Pcond) and evaporation pressure (Pevap): Pressure ratio PR = (1) 2. The condensation and evaporation pressures are determined according to the condensation and evaporation temperatures, respectively. The coefficient of performance (COP) relates the cooling capacity and power required and indicates the overall power consumption for a desired load. High COP means low energy consumption for absorption of the same cooling capacity of space to be refrigerated. Can be expressed as COP= (2) where Qevap is the cooling capacity and Pcomp is power required to drive compressor. Fig. 2 Vapour compression refrigeration system 1 2: Low pressure liquid refrigerant in the evaporator absorbs heat from its surroundings, usually air, water or some other process liquid. During this process it changes its state from a liquid to a gas, and at the evaporator exit is slightly superheated. 2 3: The superheated vapour enters the compressor where its pressure is raised. There will also be a big increase in temperature, because a proportion of the energy input into the compression process is transferred to the refrigerant. 3 4: The high pressure superheated gas passes from the compressor into the condenser. The initial part of the cooling process (3-3a) desuperheats the gas before it is then turned back into liquid (3a - 3b). The cooling for this process is usually achieved by using air or water. A further reduction in temperature happens in the pipe work and liquid receiver (3b - 4), so that the refrigerant liquid is subcooled as it enters the expansion device. 4 1: The high-pressure sub-cooled liquid passes through the expansion device, which both reduces its pressure and controls the flow into the evaporator Tests were conducted on experimental set up for R134a to find out different parameters as discussed with suitable formula. First all the components are arranged in technical manner and POE oil is filled in compressor. The system leakage is checked by applying pressure and soapy bubbles. The vacuum is created by using pump to maintain that negative pressure in the system pressure. Then R134a is charged in system of 500 g and allow to run system. Then all suction and discharge pressures were note down. Pcond and Pevap. Temperature sensors are located at respective 8 locations to measure exact temperature at that point. 3. Isentropic work of compressor (Wcomp) is expressed as : W comp = (h2-h1) (3) 4. refrigeration effect RE in other words the heat transfer rate of the evaporator (Qevap) is calculated as: RE=Qevap=(h1-h4) (4) 5. Power per ton of refrigeration is calculated as: P/TR = (5) IV. RESULTS AND DISCUSSION Experiments were carried out to investigate the thermal performance of refrigerator system and variations of temperature for each component with respect to time. By using R134a refrigerants and zeotropic blends of R600a and R290 (50/50) is studied with different parameter at different load conditions. Fig. Time Vs TR, Tw, Tcab, Tei, Teo at 40 lit condition graph for R134a 2015, IERJ All Rights Reserved Page 4

directly cooled refrigerator using R290/R600a (55/45) Elsevier,2007. [2] Gaurav, Raj Kumar, Performance Analysis of Household Refrigerator with Alternate Refrigerants International Journal of Innovative Research in Science, Engineering and Vol. 3, Issue 4, April 2014. Fig.Time Vs TR, Tw, Tcab, Tei, Teo at 40 lit condition graph for zeotropic blend of R600a and R290 (50/50) Fig.COP comparision for R134a and Zeotropic blend of R600a and R290(50/50) V. CONCLUSION An experimental study has been carried out to investigate the thermal performance of refrigerator system with different refrigerants and its comparative study. 1. The thermal performance of R134a refrigerants and zeotropic blends of R600a and R290 (50/50) is studied at full load 40lit load conditions and comparison found that evaporator always shows lower temperature for R600a and R290 blend at all conditions. 2. Experimental results also revealed that the mass of R600a and R290 (50/50) had crucial effects on thermal performance. Approx. We found there is 60 % charge reduction of R600a and R290 (50/50) because of higher latent heat of vaporization. 3. COP of R600a and R290 (50/50) is found to be increased at all conditions compared with R134a. At full load 40lit average COP increments is found to be 4.6 Hydrocarbons blends may replace R-134a without any system modifications and COP of the system is improved with reduced energy consumption. So our future intension is that increase the requirement of HC-as a refrigerant in all types of domestic refrigerators and air conditioning system in near future. Due to the zero ozone depletion potential (ODP) and negligible global warming potential (GWP), environments becomes a safe and sweets. In develop countries HC as a refrigerant use in car air conditioning as well as industrial air conditioning. [3] Mohd. Aasim Nazeer, Ahmad Quraishi, U. S.Wankhede, Use of Hydrocarbons and Other Blends as Refrigerant, International Journal of Modern Engineering ResearchVol.3, Issue.1, Jan- Feb. 2013. [4] Rajanikant Y. Mahajan, Sanjaykumar A. Borikar, Performance Evaluation of Domestic Refrigerator Using Hc-12a Refrigerant as an Alternative Refrigerant to R12 And R134a, The International Journal Of Engineering And Science (IJES),Volume 3, Issue 10, Pages 26-37, 2014. [5] Dr. A. G. Matani 1, Mukesh K. Agrawal, Effect of capillary diameter on the performance of VCRS using R134a, HC mixture and R401a as working medium, International Journal of Application or Innovation in Engineering & Management (IJAIEM), Volume 2, Issue 3, March 2013. [6] M. G. Almeidaa, C. R. F. Barbosa, THERMODYNAMIC AND THERMOPHYSICAL ASSESSMENT OF HYDROCARBONS APPLICATION IN HOUSEHOULD REFRIGERATOR, Vol. 9, p. 19-2, December 2010. [7] P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan, Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants, International Journal of Engineering and Innovative Technology (IJEIT), Volume 2, Issue 10, April 2013. [8] A.Senthilkumar, R.Praveen, performance analysis of a domestic refrigerator using cuo r600a nano refrigerant as working fluid, international conference on recent advancement in mechanical engineering &technology, jchps special issue 9: april 2015. REFERENCES [1] Moo-Yeon Lee, Dong-Yeon Lee, Yongchan Kim, Performance characteristics of a small-capacity 2015, IERJ All Rights Reserved Page 5