Stopper II SERIES ADA. We protect the things that protect you

Similar documents
Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Illuminated Stopper Station Push Button

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

Stopper II Heated Enclosure

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Addendum for STI-6406 with Dual Access Control

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTION In-Ground Color Changing

Lumination TM Volumetric Retrofit Kit

Installation and ZONES: Operation Manual. Model: ON STI-34108

Installation Instructions

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

SEL-3422 Motor Relay HMI Quick-Start Guide

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Wi-Fi DOOR/WINDOW SENSOR

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

Installation Instructions

UNI 321. User s Guide

Atomic Digital Office Clock

Installation Instructions

ADC-T2000. Smart Thermostat v1.5

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

Wireless Outdoor Air Reset Adaptor PN:

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

FES - Series Portable Electric Heaters

Installation Instructions

GBX GAS BOILERS USER S INFORMATION MANUAL

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

200i User s information manual

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

HEATING SYSTEMS Systèmes de chauffage. THERMO PRO 50 Eco. Spare Parts List Liste de pieces détachées

Occupancy Sensor OCS 100W Setup Guide

HEATING SYSTEMS Systèmes de chauffage. THERMO PRO 50 Eco. Spare Parts List Liste de pieces détachées

Installation Instructions If you have questions, call or visit our website at:

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

1100X Wireless Receivers

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

SZ-PIR04N ZigBee Motion Detector Installation Guide

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

Draft - develop and review

LED Dusk to Down Fixture

ADT. Pulse 2017ADT LLC

Installation Instructions If you have questions, call or visit our website at:

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

GARAGE DOOR OPENER KIT

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

Design Guide with Installation Instructions

Instruction Manual PC55O. With PC5OORK Keypad

SPREMIAGRUMI MANUALE D USO E MANUTENZIONE

Product Catalog. For specs & details go to sti-usa.com 1

Location Requirements

INSTALLATION INSTRUCTIONS

AGA TOTAL CONTROL. Model No. - TC3

CD-Px Series Duct Mount CO 2 Transmitters

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Lumination TM Controls Accessory LPL Series Controller Box

SERIES PSCII GAS BOILERS

Installation Instructions

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

INSTALLATION INSTRUCTIONS

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Installation Instructions

SOLA SM II Light Engine Instruction Manual

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Over 25 years working around the clock, around the world

520 Series. AngleMix Thermostatic mixing valve NA Function

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

Nest x Yale Lock Programming/Troubleshooting Guide

FRULLATORE B210 BLENDER MIXEUR STANDMIXER BEDIENUNGS- UND WARTUNGSANLEITUNG BATIDORA MANUAL DE USO Y MANTENIMIENTO MANUALE D USO E MANUTENZIONE

Innovative Lighting Smooth Light Recessed Luminaires

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

1100D Wireless Receiver

Instruction Manual. ESCORT558O Version 1.1

OPERATING INSTRUCTIONS INSTRUCTIONS DE FONCTIONNEMENT

WARNING WARNING WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

Installation Instructions

Instruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica.

Installation Instructions If you have questions, call or visit our website at:

USER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model

Transcription:

Stopper II SERIES ADA Compliant See Testing Approvals Can be used as a guard against physical damage to manual pull station, with or without optional warning horn. Optional horn has choice of 95 db or 105 db (measured at 1 foot). Standard red units have In Case of Fire... label unless specified with no label or custom label (extra charge for custom label). Horn housing is available in red, blue, green or yellow with optional custom labeling. Typical working properties of polycarbonate are -40 to 250 F (-40 to 121 C). Three year guarantee against breakage of polycarbonate housing in normal use (one year on electro mechanical and electronic components). With backplate and gaskets, UL Listed to NEMA 3R Standards (IP 44 Rating equivalency). Photo is a generic representation to reflect the many manufacturers of manual pull stations. We protect the things that protect you. - 1 -

UL Listed Models Included on this Install Sheet Indoor Use: STI-1100 With horn for flush mounted appliances STI-1100RC With horn for flush mounted appliances includes relay contacts capable of operating from 9-24 VDC remote power or internal 9V battery power STI-1130 With horn and 2 conduit spacer for surface mounted appliances and electrical boxes STI-1130RC Surface mounted version of the 1100RC includes 2 conduit spacer STI-1200 Without horn for flush mounted appliances STI-1230 Without horn, with 2 conduit spacer for surface mounted appliances and electrical boxes Indoor/Outdoor Use (Weather Stopper Models) All outdoor units include necessary gaskets. STI-1150 With horn for flush mounted appliances STI-1150RC With horn for flush mounted appliances includes relay contacts capable of operating from 9-24 VDC remote power or internal 9V battery power also includes weather gasket STI-1155 Surface mounted version of the STI-1150 includes 2 conduit spacer STI-1155RC Surface mounted version of the STI-1150RC includes 2 conduit spacer STI-1250 Without horn for flush mounted appliances STI-3150 Without horn with 2 conduit spacer for surface mounted appliances and electrical boxes STI-1102 Replacement horn for cover with alarm Custom-LBL Custom text message for horn housing Testing Approvals It has been tested and approved or listed by: Underwriter Laboratories and cul No. 49G2 UL/cUL Certified to meet ADA compliance Factory Mutual No. OG6A2.AY (STI-1100 and STI-1130 only) NEMA 3R when mounted to smooth non-masonry surfaces (only for Stopper II models with backplate and gaskets) NYC BSA #947-81-5A IP 44 Rating (NEMA 3R) Obtain local fire marshal approval for State of California Patents United States No. 4267549, Canada No. 1147828Z Specifications Polycarbonate Enclosure Flammability UL94 V-2 Wall Thickness.095 inches NEMA Rating Meets NEMA 3R when mounted to smooth non-masonry surfaces Gaskets Closed Cell IV2 with pressure sensitive adhesive Replace after 5 years Horn 9V 12V 24V Low (95 db @ 1 ft.) 96mA 107mA 125mA High (105 db @ 1 ft.) 130mA 145mA 182mA Min. Operating Req. 2V @ 20mA 4V @ 20mA 4V @ 20mA Relay 9V 12V 24V Relay 23mA 25mA 29mA Min. Activation Voltage 3.7V 5.8V 5.8V Reset Voltage 1.5V 3.3V 3.3V Dry Contact Rating <30V, 1A <30V, 1A <30V, 1A (type Form C ) - 2 -

Specifications (continued) Temperature Range -40 to 120 F (-40 to 49 C) For temperatures below -4 F (-20 C) recommend using remote power source Warranty Three year guarantee against breakage of polycarbonate housing in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14. Important Notice Stopper II is intended to be used in areas where the incidence of false fire alarms from manual pull stations is high or has proven to be a serious problem. Any disadvantage of this device is more than balanced when one considers the consequences of false fire alarms, especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If you have, or may have, a problem with false fire alarms or physical/ weather damage to your fire alarm activation devices, the Stopper II could prove invaluable. Avis important Le Stopper II est destiné à être utilisé dans les zones où l occurrence de fausses alertes d incendie issues d avertisseurs d incendie manuels est élevée ou présente un problème grave. Un quelconque inconvénient de ce dispositif est vite contrecarré par les conséquences des fausses alertes d incendie, surtout lorsque le personnel et l équipement des services d incendie réagissent à une fausse alerte d incendie alors que leur intervention ailleurs sur un vrai incendie s avère nécessaire en même temps. À cela s ajoute l agitation éprouvée dans l établissement au moment du déclenchement d une fausse alerte. Si vous rencontrez, ou risquez de rencontrer, un problème avec les fausses alertes d incendie ou avec l éventuel endommagement par effet climatique ou physique de vos dispositifs de déclenchement des alertes d incendie, le Stopper II pourra alors se révéler d une valeur inestimable. Installation Notes 1. When used outdoors, the manual pull station must also be rated for outdoor use. 2. The relay contacts on Model STI-1100RC, STI-1130RC, STI-1150RC and STI-1155RC, UL Listing does not permit connection to fire alarm or a life safety function. 3. According to UL Listing, models powered from an external power source cannot be supplied from the fire alarm panel. 4. When properly installed the operation of this cover will not interfere with the function of your life safety system. 5. A backplate and gaskets must be used to achieve NEMA 3R integrity. 6. Horn must be tested annually for proper operation. Battery replacement is recommended annually dependent on use and battery expiration date. 7. If mounting to an uneven surface STI recommends the use of the STI-1280 backplate to ensure proper sealing. If wire access or screw mounting holes are needed, backplate may be drilled as necessary. Remarques sur l installation 1. L avertisseur d incendie manuel doit être homologué pour une utilisation à l extérieur en cas de recours à une telle utilisation. 2. L homologation UL des contacts de relais sur les modèles STI-1100RC, STI-1130RC, STI-1150RC et STI-1155RC n autorise pas leur connexion à une fonction d alerte d incendie ou de sécurité des personnes. 3. Selon l homologation UL, les modèles alimentés par une source électrique externe ne peuvent pas être intégrés au panneau d alerte d incendie. 4. Lorsqu il est correctement installé, le fonctionnement de ce couvercle ne provoquera aucune interférence avec le fonctionnement de votre système de sécurité des personnes. 5. Un palastre et des joints d étanchéité doivent être utilisés pour atteindre l intégrité NEMA 3R. 6. L alarme sonore doit être testée annuellement pour confirmer son bon fonctionnement. Il est recommandé de remplacer la pile chaque année et ce en fonction du taux d utilisation et de la validité de la pile. 7. Dans le cas d un montage sur une surface irrégulière, STI recommande l utilisation du palastre STI-1280 pour garantir une étanchéité adéquate contre la surface de montage. S il est nécessaire d accéder aux fils ou aux trous des vis de montage, le palastre peut être percé tel que requis. - 3 -

Installation Instructions 1. The power switch is in the OFF position (Fig. 5). Using frame or optional STI-1280 backplate (recommended with all Weather Stopper models) as a template, mark mounting holes on wall taking into consideration placement of pull station or refer to Fig. 1 for dimensional hole placement from center of clear opening. NOTE: Be sure cover will not interfere with operation of the pull station when installed. FIND CENTER OF PULL STATION AND USE GIVEN DIMENSIONS TO CENTER PULL STATION IN VISIBLE OPENING OF COVER. DRILL 4 HOLES PER STEP 2. IN CASE OF FIRE - LIFT COVER PULL FIRE ALARM 4.9375 in. (125mm) IF DRILLING INTO MASONRY OR DRYWALL USE PROVIDED ANCHORS. DRILL (4) 1/4 (6.3mm) HOLES 1 1/4 DEEP. IF DRILLING INTO WOOD, DRILL (4) 5/32 (3.9mm) HOLES 1 1/4 DEEP. DO NOT USE ANCHORS IF DRILLING INTO WOOD. LIFT HERE 6.25 in. (159mm) 2 in. (51mm) 3.125 in. (79mm) Fig.1 2. If using STI-1280 backplate, refer to Fig. 2 and 3 for install instructions depending on your EXPLODED application. NOTE: When drilling hole in backplate NEMA 3R integrity is compromised. ELECTRONIC VIE FACTORY VOLTAGE SETTINGS: BATTERY POWERED UNITS: 9 VOLT REMOTE POWER "RC" UNITS: 24 VOLT USE 24 VOLT SETTING FOR USE WITH 12 VOLT DC INPUT POWER USE ONLY 9 VOLT BATTERY JUMPER USED ON STANDARD 9 VOLT INTERNALLY POWERED MODELS EXISTING PULL STATION WHEN GASKETS ARE USED, INSTALL GASKET VOLUME PROVIDED SELECTOR BY PEELING OFF LOW BACKING PAPER AND HI APPLY WITH FACTORY ADHESIVE VOLUME FACING SETTING: WALL. HIGHALIGN HOLES IN GASKET WITH HOLES DRILLED AND STICK ON MOUNTING SURFACE. FLUSH MOUNT JUMPER INSTALLED ON WITH "RC" OPTIONS MODELS BACKPLATE FOR EXTERNALLY SUPPLIED 12VDC OR NOTE: WHEN DRILLING 24VDC HOLE POWER IN BACKPLATE NEMA 3R NOTE: INTEGRITY SMALL CONNECTOR ON JUMPER IS COMPROMISED FITS INTO PLUG ON RELAY BOARD ADHESIVE SIDE THIS JUMPER IS INCLUDED WITH "RC MODELS FOR USE WHEN INTERNAL 9VDC BATTERY POWER IS REQUIRED (BATTERY NOT INCLUDED) SMALL CONNECTOR ON JUMPER FITS INTO PLUG ON RELAY BOARD USING THIS JUMPER REQUIRES VOLTAGE SELECTOR SET TO 9V STI-1103 RELAY BOARD IS USED ON "RC" MODELS VOLTAGE SELECTOR 9V 24V Fig. 2-4 -

3. Align frame and put screws through frame holes, into anchors and tighten (if used, through spacer, gaskets and optional backplate). For STI-1200, continue to Step 8. NOTE: When using STI-3100 spacer, be sure to install conduit knockout, any additional ventilation and gaskets before you tighten to the wall. When using conduit gasket STI-3004, place gasket around conduit in proper location and install the spacer. For added protection a bead of silicone may be applied to conduit fitting and between STI-1280 backplate and wall (Fig. 3A). Refer to exploded view of flush and surface mount installation options Fig. 2 and 3. ADDED SILICONE SURFACE MOUNT WITH OPTIONS Fig. 3A ANCHOR (4) PROVIDED STI-1280 BACKPLATE EXISTING PULL STATION INSERT PLASTIC KNOCK-OUT, INTO SPACER NOTCH IF CONDUIT NOT NEEDED (2) PROVIDED STI-3004 GASKET NOTE: USE 1/2 in. WITH 3/4 in. CONDUIT STI-3104 CONDUIT SPACER SHOWN WITH SUB-316 USE IN SPACER BOTTOM NOTCH ONLY STI-3002 WEATHER GASKET INSTALL ADHESIVE TOWARD MOUNTING SURFACE AND THICK END OF GASKET TOWARDS TOP OF ASSEMBLY FOR RETROFIT APPLICATIONS, CUT GASKET AT THE BOTTOM TO INSTALL BEHIND CONDUIT SUB-316 VENT (NOT INCLUDED) BREAK OUT ALL FOUR CONDUIT INSERTS AND TRIM SHARP EDGES #10-3 1/2 SCREW (4) PROVIDED Fig. 3 B PUSH IN PULL DOWN NOTE: HOLD FRAME TO THE WALL (IF MOUNTED) WHILE ATTACHING THE LANYARD DETAIL B Fig. 4-5 -

4. Make any external connections for remote power or relay options. Refer to Fig. 5 for wiring details. 5. For models using the 2 spacer to install the cover, insert the cable end stop into the pocket on the inside of the frame. Hold the frame against the wall and pull the cable to lock into the slot. Repeat for 2nd cable (FIG. 4). 6. Slide power switch, on back of horn housing, to ON position (Fig. 5). When power is connected to unit horn should sound. NOTE: If external power source is used horn will not sound until power is turned on at source. 7. Push switch in to silence horn while tightening switch locking screw (Fig. 5 for location of screw). This prevents slide switch from being shut off during unauthorized use. NOTE: Surface Mount version is shipped with screw in locked position. 8. Close cover on frame by aligning tabs on cover with slots on frame and push bottom on tightly, horn should silence. To test: lift cover, horn should sound, and return cover to frame to silence horn. Unit is armed for operation. OPTIONAL STI-1103 RELAY BOARD OFF TO LOCK POWER SWITCH IN THE "OFF" OR "ON" POSITION TIGHTEN LOCKING SCREW FULLY UNTIL SCREW MAKES CONTACT WITH SWITCH PAD AS SHOWN. 5 INCHES OF CABLE IS PROVIDED FOR SERVICE LOOP. MAKE SURE THIS LOOP AND ALL OTHER CABLES DO NOT INTERFERE WITH STATION OPERATION. RED + 12-24 VDC { BLACK GREEN NORMALLY OPEN BLUE COMMON WHITE NORMALLY CLOSED SWITCH LOCKING SCREW 3/32 in. ALLEN WRENCH (NOT PROVIDED) OPTIONAL RELAY CONTACT SETTINGS STI MODELS 1100RC, 1130RC, 1150RC AND 1155RC Fig. 5 EXPLODED ELECTRONIC VIEW FACTORY VOLTAGE SETTINGS: BATTERY POWERED UNITS: 9 VOLT REMOTE POWER "RC" UNITS: 24 VOLT USE 24 VOLT SETTING FOR USE WITH 12 VOLT DC INPUT POWER USE ONLY 9 VOLT BATTERY JUMPER USED ON STANDARD 9 VOLT INTERNALLY POWERED MODELS JUMPER INSTALLED ON "RC" MODELS FOR EXTERNALLY SUPPLIED 12VDC OR 24VDC POWER NOTE: SMALL CONNECTOR ON JUMPER FITS INTO PLUG ON RELAY BOARD THIS JUMPER IS INCLUDED WITH "RC" MODELS FOR USE WHEN INTERNAL 9VDC BATTERY POWER IS REQUIRED. (BATTERY NOT INCLUDED) SMALL CONNECTOR ON JUMPER FITS INTO PLUG ON RELAY BOARD USING THIS JUMPER REQUIRES VOLTAGE SELECTOR SET TO 9V VOLUME SELECTOR LOW HI FACTORY VOLUME SETTING: HIGH - 6 - STI-1103 RELAY BOARD IS USED ON "RC" MODELS VOLTAGE SELECTOR 9V 24V Fig. 6

Gasket Installation Use of gaskets is necessary to ensure a proper seal in weatherproof applications. Weather Stopper models ship complete with all necessary gaskets and should be used accordingly. For flush mount weather applications, one STI-3002 must be used between the frame or spacer and wall or backplate (see Fig. 3). An STI-3004 gasket must be used around all entering conduit. For surface mount applications, it is also recommended that the conduit insert with holes be installed in the bottom knockout of the conduit spacer. This helps prevent excessive condensation buildup. STI recommends gasket replacement every five years. (UL requires listing of pull station to be UL Listed for outdoor installations.) Battery Replacement Instructions 1. Remove the cover from the frame. It is not necessary to remove the cables from the frame. 2. Use a 3/32 allen wrench to loosen the button head screw located next to the switch far enough to slide the switch to the off position. 3. Holding the horn housing and cover in one hand, remove the button head screw located on the top of the cover with the same allen wrench. 4. Set the clear cover aside and remove the horn housing cover. 5. Replace the battery with a 9 Volt battery only. Be careful to keep the wires away from the slide switch and the micro-switch. 6. Reassemble the unit making sure that the horn housing fits into the tabs on the horn housing cover; and that this assembly is mounted evenly into the clear cover. 7. Replace the button head screw through the top of the clear cover and into the top of the horn. 8. Slide the switch to the on position. The horn should sound. 9. Push the switch in to silence horn while tightening the on position locking screw. 10. Replace the cover onto the frame and test by removing the cover from the frame. The horn should sound when removed and silence when cover is replaced. If unit does not operate correctly, contact Safety Technology International, Inc. Polycarbonate Cleaning Instructions Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth. Rinse once more, then dry with a soft cloth or chamois. Exercise caution when using water inside enclosure. Make sure unit is completely dry inside before reassembling. To remove grease or wet paint from exterior of cover, rub gently with a cloth thoroughly wetted with Naptha. Then wash and rinse. (Do not use razor blades.) Options Available STI-1280 Backplate for mounting appliances to uneven surface. STI-3002 Weather gaskets STI-3100 Large conduit clear 2 conduit spacer STI-3004 1/2 and 3/4 rigid conduit gasket - 7 -

Product Dimensions EXTERNAL DIMENSIONS: Flush 7.1 x 10.0 x 3.3 in. (180 x 254 x 84 mm) W x H x D Surface 7.23 x 10.1 x 5.28 in. (184 x 256 x 134 mm) COVER HORN HOUSING 5.37 in. (137mm) 6 in. (152mm) 3.175 in. (81mm) 1 in. (25mm) SPACER COVER 8.875 in. (225mm) SIDE VIEW Models with Horn 5.34 in. (136mm) 7.4 in. (188mm) 2 in. (51mm) 3.175 in. (81mm).5 in. (13mm) SPACER 8.875 in. (225mm) SIDE VIEW Models without Horn 2 in. (51mm) 3 in. (76mm) 4 in. (102mm) 5 in. (127mm) 5.5 in. (140mm) 3.18 in. 2.73 in. (81mm) 2.32 in. (70mm) 1.61 in. (59mm) (41mm) 6.81 in. (173mm).78 in. (20mm) SPACER ADDS 2 DEPTH (50mm) END VIEW All Models 2306 Airport Rd Waterford, MI 48327 Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 info@sti-europe.com www.sti-europe.com Subject to change without notice. Printed in USA - 8 - STOPPER II SERIES IS OCT2014