Insert Manual. HL3 Series WARNING. For Your Safety

Similar documents
Insert Manual. DX3 Series WARNING. For Your Safety

Insert Manual. SV Series WARNING. For Your Safety

Insert Manual. XTS3 Series WARNING. For Your Safety. For complete installation instructions, see the General Manual that accompanies this insert.

For complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual.

Insert Manual. DET3 Series WARNING. For Your Safety

Insert Manual. RVA2 Series WARNING. For Your Safety

Insert Manual. RHT Series WARNING. For Your Safety

Insert Manual. DES Series WARNING. For Your Safety

Typical Mount Height. Combustion Chamber

Insert Manual. DX3L Series WARNING. For Your Safety

Insert Manual. CL Series WARNING. For Your Safety

Insert Manual. DES3 Series WARNING. For Your Safety

Insert Manual. DX3 Series WARNING. For Your Safety

Min. Mount Height. Min. Mount Height. Length Weight

DX2 Series. Models V.6/03

Typical Mount Height. Combustion Chamber(s)

LD Series Installation Manual

LS Series Installation Manual

LD3 Series Installation Manual

AVS Series Installation Manual

LS3 Series Installation Manual

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

BGH Series Hot Surface Ignition Control

LNB 1000 Series Low Nox Burner

CLEARANCES TO COMBUSTIBLES

DX SERIES TUBE HEATER

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Tube Heater General Manual

SERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

CSD-1 COMMERCIAL BOILER CONTROLS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Installation, Operation, Maintenance and Parts Manual

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

PT Series Manual WARNING. Detroit Radiant Products Co. Installation Operation Maintenance and Parts. For Your Safety

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

LGB Gas fired boiler

Multi-Function Cooktop

EHL Series Installation, Operation, Maintenance and Parts Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

EHL Series Installation, Operation, Maintenance, and Parts Manual

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Series RE Infrared Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

A. Product Data: Include rated capacities, furnished specialties and accessories.

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS

Installation Requirements for Models:

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

GARAGE / WORKSHOP INFRARED HEATERS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

* For complete installation instructions, see General IOM this piece was inserted within. Also available at Min. Mtg.

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS

THC- 355DF (Dual Fuel)

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Installation Instructions Dual Fuel Ranges

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

USER S INFORMATION MANUAL

PE MODEL WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

TUBE HEATER TROUBLESHOOTING GUIDE

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Series GR/ET Infrared Heater

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

LUMINOUS A PATIO HEATER LIKE NO OTHER

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Parts List for Ener-Radiant XL Tube Heaters

GTD Series Installation, Operation, Maintenance and Parts Manual

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

A.O. Smith Water Products Company

INSTALLATION GUIDE Dual Fuel Ranges

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

Service Manual Model 3163

Owner: Keep this manual in a safe place in order to provide your service technician with the necessary information.

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

Model Universal Oil Primary Control

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Technical Manual MAY 2008 Edition

Transcription:

Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater system. This insert manual is a supplement to the Tube Heater eneral Manual and provides specific information related to the model. All persons involved with the installation, operation and maintenance of the heater system must read and understand the information in this insert manual and the accompanying Tube Heater eneral Manual. For Your Safety If you smell gas:! ARNIN Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. This heater must be installed and serviced by trained gas installation and service personnel only. Failure to comply could result in personal injury, asphyxiation, death, fire or property damage. In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats, in a conspicuous location. t for residential use! Do not use this heater in the home, sleeping quarters, attached garages, etc. Installation of a commercial tube heater system in residential indoor spaces may result in property damage, serious injury, asphyxiation or death. Do not try to light any appliance. Immediately call your gas supplier from a neighbor s phone. Do not touch any electrical switch. Follow the gas supplier s instructions. Do not use any phone in your building. If you cannot reach your gas supplier, call the fire department. INSTALLER: Present this manual to the end user. Keep these instructions in a clean and dry place for future reference. Model#: Serial #: (located on rating label) LIHL3-Rev. 27512 Print: 3M-8/13_r1-11/13(CDS) Replaces: Rev.13012_3M-8/12(CDS)

Contents 1.0 Safety....3 Safety Labels and Locations...3 Clearances to Combustibles...4 2.0 Installation.............................................................. 6 Electrical Requirements....6 iring............................................................. 7 Specifications...10 Tube Installation Sequence...11 3.0 peration...12 Sequence of peration...12 Thermostat........................................................ 12 Diagnostics........................................................ 13 4.0 Troubleshooting uide................................................... 14 5.0 Parts...18 Components....................................................... 18 Parts List...18 Kit Contents Check List...20 Approvals....20 Limited arranty...20 NTE: See page 10 for a list of available models and specifications. 2

1.0 Safety Safety Labels and Locations 1.0 Safety Read and understand all safety information and warnings in this insert manual and the Tube Heater eneral Manual before installation, operation and maintenance of the radiant tube heater system. Safety Labels and Their Locations Product safety signs or labels should be replaced by the product user when they no longer are legible. Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels. TP-114 SAMPLE TP-3014 Air Metering rifice D NT REMVE 120V 3 F/N: LLAC HT NEUTRAL Air Metering rifice EARTH - 120V HEATER INPUT - F/N: LLV3EP1 HT 120V NEUTRAL EARTH Back Panel - 120V HEATER INPUT - HIH 24V L NEUTRAL - 24V HEATER INPUT - HIH 24V L 24V UT - 24V HEATER UTPUT - F/N: LLV3EP2 F/N: LLV3EP4 (range crescent -with relay option) F/N: LLTB018 (Natural as) F/N: LLTB019 (LP as) (hite crescent - no relay) F/N: LLV3EP14 (perational Indicator Lights) SERVICE ACCESS PANEL KEEP CVER IN PLACE. REMVE FR SERVICE NLY. CNTRLS & AS VALVE CMPARTMENT KEEP CVER IN PLACE. REMVE FR SERVICE NLY. CAUTIN: HT SURFACE. SERVICE ACCESS PANEL 1. Disconnect gas & electricity. 2. Remove cover by lifting top cover upward and outward. INITER & FLAME SENSE CMPARTMENT SERVICE ACCESS PANEL KEEP CVER IN PLACE. REMVE FR SERVICE NLY. 1. Disconnect gas & electricity. 2. Remove top cover (2 thumbscrews). 3. Remove tsix (6) 1/4 screws. 4. Lift and remove panel. FAN CMPARTMENT 1. Disconnect gas & electricity. 2. Remove four (4) thumbscrews. 3. Remove top cover. 4. Swing hinged panel downward. Top Panel F/N: LLTCL001L/C/R Clearance to Combustibles Labels Bottom Panel F/N: LLL1 Logo Label 3

1. Disconnect gas & electricity. 2. Remove cover by lifting top cover upward and outward. CAUTIN: HT SURFACE. KEEP CVER IN PLACE. REMVE FR SERVICE NLY. RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER FR INDR (n-residential) INSTALLATIN NLY. Class IIIA Permanent Label MDEL N. INPUT BTU/H FR USE ITH DET-40-125N(-3) 125,000 / 95,000 Natural as HL3 Volts AC: Manifold Pressure: Heater Type 120VAC - 60Hz 3.5 in. Inches.C.P. C1 AMPS - Starting: Maximum Inlet Pressure: Minimum Mounting Angle: 1.7 14 in. Inches.C.P. 0 DEREES AMPS - Running: Minimum Inlet Pressure: Maximum Mounting Angle: 1.1 5.0 in. Inches.C.P. 45 DEREES Combustion Chamber: 4 Black Coated Aluminized DESIN CMPLIES ITH: ANSI Z83.20b-2004-AS FIRED L INTENSITY INFRA-RED HTR. DETRIT RADIANT PRDUCTS CMPANY Serial.: 1208XXXXXXXXXX 0001 21400 HVER RAD - ARREN, MI (586) 756-0950 - www.drp-co.com 1.0 Safety Safety Labels and Locations Clearance to Combustibles SERVICE ACCESS PANEL INITER & FLAME SENSE CMPARTMENT 1. Turn off gas & electricity. 2. Remove cover by lifting top cover upward and outward. CAUTIN: HT SURFACE. KEEP CVER IN PLACE. REMVE FR SERVICE NLY. SERVICE ACCESS PANEL INITER & FLAME SENSE CMPARTMENT F/N: LLTB026 SERVICE ACCESS PANEL F/N: LLTB024L HL-40-125N(-3) Serial.: 0804XXXXXXXXXX 0001 Production Code: HL3-125 Stock: ne Version: 7.08 Add-n: N/A Data on this label is for the model shown on this label. If your heater has been converted, this information is not accurate. Please contact the factory for assistance. BURNER CMPNENTS: (Specify TP-# s) as Valve: 3654-224-N 840A Diag. Light: n Circuit Board Circuit Board: 35-66 851B Term. Block: ne N/A ire Harness: 3 PCS Harness 3252 Transformer: 40 VA 826 N.. Switch: ne N/A Fan: Fasco Lg. 55A N.. VL rifice: ne Alt. Fan: 50Hz - 120V 55B N.C. Switch: ne N/A Alt. Fan Usage: hen Specified N.C. VL rifice: ne Relay: Picker x2 1325 Diff Switch: IS22010051F5166 264E Filter: ne N/A Diff VL rifice: rey (+ / -) 24 Volt In: 3 T-plug 832 Igniter: rton 50 120 Volt In: 6 Blk. Cord 333 Burner: Mid 201B as In: 7/8 FC 83 16 Tube: 4 en. 380 Extra VL rifice: ne Ind. Lights: Yellow - 24V 828 HEATER rifice Type: C1 C2 C3 Internal Use nly: TYPE: as: TP-204# 19 19 19 Electric: LLT038 Special 1: 17 C1 Air: TP-44# 1 5/16 1 7/16 1 5/16 Tag: ne Special 2: 1 7/16 For parts replacement information, contact factory at 586-756-0950 or visit www.drp-co.com/parts. SAMPLE Burner Control Box Component Label (located inside the center compartment lid) SERVICE ACCESS PANEL Controls Compartment MDEL N. HL-40-125N(-3) Volts AC: 120V - 60Hz AMPS - Starting: 4.8 AMPS - Running: 1.1 Combustion Chamber: RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER FR UTDR USE AND INDR (n-residential) INSTALLATIN NLY. Class IIIA Permanent Label INPUT BTU/H 125,000 / 95,000 Manifold Pressure: 3.5 in. Maximum Inlet Pressure: 5.0 in..c.p. 14 in..c.p. 0 DEREES Minimum Inlet Pressure: Maximum Mounting Angle: SAMPLE FR USE ITH Natural as Heater Type C1 Minimum Mounting Angle:.C.P. 45 DEREES 4 Black Coated Aluminized For stainless steel upgrades: The combustion tube is 409 Series stainless steel. DESIN CMPLIES ITH: ANSI Z83.20b-2004-AS FIRED L INTENSITY INFRA-RED HTR. Rating Plate DETRIT RADIANT PRDUCTS CMPANY 21400 HVER RAD - ARREN, MI (586) 756-0950 - www.drp-co.com Serial.: 0807XXXXXXXXXX 0001 F/N: LLTB025R 16 Burner Tube Combustion Chamber Radiant Tube(s) Fan Compartment! INSTALLER AVID EQUIPMENT FAILURE THIS 10 FT. TUBE IS THE CMBUSTIN CHAMBER. The combustion chamber utilizes either 409 stainless, titanium alloy or aluminized steel - depending on the model number of your heater. THIS TUBE MUST BE THE FIRST TUBE FLLIN THE BURNER CNTRL BX. F/N: LL01 - Clearance Safety Tag (Affix adjacent to heater s thermostat) Clearance to Combustibles! ARNIN Placement of explosive objects, flammable objects, liquids and vapors close to the heater may result in explosion, fire, property damage, serious injury or death. Do not store or use explosive objects, liquids or vapor in the vicinity of the heater. 4 Rotate the tube s welded seam to bottom. Consult the manual(s) for further details. F/N: LLTB004 (orange) (150,000-200,000 BTU/h models and all heaters with 409 stainless steel tubes) Clearance to combustibles is defined as the minimum distance that must exist between the tube surface, or reflector, and any combustible items (see Figure 1.1). It also pertains to the distance that must be maintained from moving objects around the tube heater.

1.0 Safety Clearance to Combustibles hen installing the tube heater system, clearances to combustibles for the model tube heater and configuration must be maintained. Refer to Chart 1.1 below to determine the required distances for your model. Chart 1.1 Clearance to Combustibles in Inches (see Figure 1.1 for Mounting Angles) Mounting Sides Model Number Angle* Front Behind Top Below HL3 (20, 30, 40) - (65, 75) [N, P] 0 9 9 6 60 45 39 8 10 60 with 1 side shield 0 29 8 6 60 with 2 side shields 0 9 9 6 60 20 ft. from burner 0 7 7 6 30 HL3 (30, 40) - 100 [N, P] 0 14 14 6 66 45 39 8 10 66 with 1 side shield 0 29 8 6 66 with 2 side shields 0 16 16 6 66 20 ft. from burner 0 7 7 6 30 HL3 (30, 40, 50) - 125 [N, P] 0 20 20 6 76 45 58 8 10 76 with 1 side shield 0 42 8 6 76 with 2 side shields 0 20 20 6 76 20 ft. from burner 0 7 7 6 30 HL3 (40, 50, 60) - 150 [N, P] 0 24 24 6 81 45 58 8 10 81 with 1 side shield 0 42 8 6 81 with 2 side shields 0 23 23 6 81 20 ft. from burner 0 11 11 6 44 HL3 (40, 50, 60, 70) - 175 [N, P] 0 34 34 6 92 45 63 8 10 92 with 1 side shield 0 50 8 6 92 with 2 side shields 0 30 30 6 92 20 ft. from burner 0 11 11 6 44 HL3 (50, 60, 70) - 200 [N, P] 0 41 41 6 94 45 63 8 10 94 with 1 side shield 0 54 8 6 94 with 2 side shields 0 30 30 6 94 20 ft. from burner 0 11 11 6 44 Heaters mounted on an angle between 0 to 45 must maintain clearances posted for 0 or 45 ; whichever is greater. * The stated clearance to combustibles represents a surface temperature of 90ºF (32ºC) above room temperature. Building materials with a low heat tolerance (such as plastics, vinyl siding, canvas, tri-ply, etc.) may be subject to degradation at lower temperatures. It is the installer s responsibility to assure that adjacent materials are protected from degradation. Figure 1.1 Mounting Angles 0 Mounting Angle 45 Mounting Angle Top Top 0 Mounting Angle with 1 Side Shield (P/N: SSE) Top 0 Mounting Angle with 2 Side Shields (P/N: SSE) Top Side Side Front Behind Front Behind Side Side Below Below 5 Below Below

2.0 Installation Electrical Requirements 2.0 Installation! ARNIN Improper installation, adjustment, alteration, service or maintenance can cause property damage, serious injury or death. Read and understand the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. nly trained, qualified gas installation and service personnel may install or service this equipment. t for residential use! Do not use this heater in the home, sleeping quarters, attached garages, etc. Installation of a commercial tube heater system in residential indoor spaces may result in property damage, serious injury or death. Instructions for the following are detailed in the Tube Heater eneral Manual: Design considerations Hanger suspension and placement Tube layout and assembly Burner control box suspension Reflectors (and accessories) Venting and combustion air intake as requirements Baffle assembly te: Electronic versions of all manuals are available at www.detroitradiant.com as Requirements Type of as Required Manifold Pressure Minimum Inlet Pressure Maximum Inlet Pressure Natural 3.5 Inches..C. 5.0 Inches..C. 14.0 Inches..C. Liquefied Petroleum 10.0 Inches..C. 11.0 Inches..C. 14.0 Inches..C. IMPRTANT: Consult the Tube Heater eneral Manual for gas connection requirements. Electrical Requirements 120 Volt - 60 Hz RD, 3-wire. 24V thermostat connection. Starting current 4.8 amps Running current 1.1 amps NTICE Connecting the thermostat with a voltage other than 24V may damage the heater. The requires a 24V connection to the thermostat. This is either supplied by the heater internally (standard) or by an external transformer (with optional isolation relays, P/N: HLRP). See Figure 2.1. 6

2.0 Installation iring iring! ARNIN Electric Shock Field wiring to the tube heater must be connected and grounded in accordance with national, state, provincial, local codes and to the guidelines in the Tube Heater eneral Manual and Series Insert Manual. In the United States refer to the most current revisions to the ANSI/NFPA 70 Standard and in Canada refer to the most current revisions to the CSA C22.1 Part I Standard. Figure 2.1 Field iring Diagrams A. Single Heater, Relay (Single Thermostat). To 120VAC grounded outlet. 1/4 spade terminals required (as supplied) 24V 24VAC N Low Thermostat High HL3 Burner Box NTE: If optional yellow control cord is installed then the following wire colors apply: 24VAC ut = green Low = white High = black hen using a thermostat that requires constant power a common wire must be run form the C terminal on the thermostat back to the transformer. B. Multiple Heaters with Relay ption (Single Thermostat). To 120VAC grounded outlet. 1/4 spade terminals required (as supplied) Thermostat N HL3 Burner Box 24VAC Low High To 120VAC grounded outlet. Additional wire needed for thermostats that require constant power. External Transformer (field supplied) NTE: If optional yellow control cord is installed then the following wire colors apply: Neutral = green Low = white High = black 24VAC 120VAC HL3 Burner Box To 120VAC grounded outlet. HL3 Burner Box 120VAC Power (observe polarity) N 7

2.0 Installation iring Before field wiring this appliance - Check existing wiring; replace if necessary. te: If any of the original wire supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 105 C. Figure 2.2 Internal iring Diagrams A. 35-66 Ladder Diagram L1 120VAC N Y TRANSFRMER 120VAC 1 2 STAE R T'STAT TERMINAL 2-STAE T'STAT (FIELD SUPPLIED) PRESSURE SITCH APS PK Y 24VAC INITR ER FLAME RD PR INDICATR LIHTS ND VAL 24V TH PS LED IN/FS L2 IN/240 L1 IN/120 FC± F2 F1 (FIELD SUPPLIED) AS VALVE FEN 35-66 INITIN MDULE B. 35-66 Block Diagram L1 120VAC N R T'STAT 24V 1 2 TERMINAL STAE 2-STAE T'STAT (FIELD SUPPLIED) FEN 35-66 INITIN MDULE PK Y PR PK + Y PR Y APS PRESSURE SITCH TRANSFRMER BURNER INITR FLAME RD R HI M C C C HI C M N Y FF INDICATR LIHTS ER AS VALVE L (FIELD SUPPLIED) HI 8

2.0 Installation iring Figure 2.3 Alternative iring Diagrams A. 35-66 Ladder Diagram - ith HLRP Relay L1 N 120VAC Y TRANSFRMER 120VAC 1 2 STAE 2-STAE T'STAT (FIELD SUPPLIED) Y()* ()* R ()* T'STAT CNNECTIN Y HIH RELAY Y R Y L RELAY PRESSURE SITCH APS1 Y PK 24VAC INITR ER FLAME RD PR L1 24VAC 120VAC N INDICATR LIHTS 120/24VAC TRANSFRMER (FIELD SUPPLIED) AS VALVE FIELD SUPPLIED ND VAL 24V TH PS LED IN/FS L2 IN/240 L1 IN/120 FEN 35-66 INITIN MDULE * If thermostat connetion is via a yellow control cord, use parenthesized color code FC ± F2 F1 B. 35-66 Block Diagram - ith HLRP Relay L1 120VAC N R()* T'STAT Y CNNECTIN 24V 1 2 STAE ()* 2-STAE T'STAT (FIELD SUPPLIED) 120/24V TRANSFRMER (FIELD SUPPLIED) Y()* FEN 35-66 INITIN MDULE FIELD SUPPLIED * If thermostat connetion is via a yellow control cord, use parenthesized color code N NC HIH CM RELAY N NC L CM RELAY Y PK PR Y PK ER Y R + APS1 (N) PRESSURE SITCH PR Y TRANSFRMER INITR FLAME RD AS VALVE R L HI M C C C M HI C HI Y N FF INDICATR LIHTS 9

2.0 Installation Product Specifications Specifications Chart 2.1 Specifications Model Number as Type (select one) BTU/h (High Fire) BTU/h (Low Fire) Straight Length U-Tube Length Standard eight (lbs.) Stainless Steel eight (lbs.) Recommended Mounting Height Combustion Chamber (Black Coated) Radiant Emitter Tube(s) (Black Coated) Radiant Surface Area (sq. ft.) 36 Baffle Quantity HL3-20-65 N or LP 65,000 50,000 21-9 13-1 120 N/A 9 to 14 Alum Alum 20.2 5 HL3-20-75 N or LP 75,000 50,000 21-9 13-1 120 145 10 to 15 Alum Alum 20.2 5 HL3-30-65 N or LP 65,000 50,000 31-5 **17-9 160 N/A 10 to 15 Alum Alum 30.4 4 HL3-30-75 N or LP 75,000 50,000 31-5 **17-9 160 195 11 to 18 Alum Alum 30.4 5 HL3-30-100 N or LP 100,000 65,000 31-5 **17-9 160 195 12 to 20 Alum Alum 30.4 5 HL3-30-125 N or LP 125,000 82,000 31-5 **17-9 160 195 13 to 23 Alum Alum 30.4 6 HL3-40-65 N or LP 65,000 50,000 41-1 22-9 190 N/A 11 to 18 Alum Alum 40.5 3 HL3-40-75 N or LP 75,000 50,000 41-1 22-9 190 235 11 to 18 Alum Alum 40.5 4 HL3-40-100 N or LP 100,000 65,000 41-1 22-9 190 235 12 to 20 Alum Alum 40.5 4 HL3-40-125 N or LP 125,000 82,000 41-1 22-9 190 235 13 to 23 Alum Alum 40.5 5 HL3-40-150 N or LP *150,000 100,000 41-1 22-9 190 235 14 to 25 Titan Alum 40.5 5 HL3-40-175 N or LP *175,000 125,000 41-1 22-9 190 235 15 to 27 Titan Alum 40.5 5 HL3-50-125 N or LP 125,000 82,000 50-9 **27-5 235 290 15 to 27 Alum Alum 50.6 3 HL3-50-150 N or LP *150,000 100,000 50-9 **27-5 235 290 15 to 27 Titan Alum 50.6 3 HL3-50-175 N or LP *175,000 125,000 50-9 **27-5 235 N/A 16 to 30 Titan Alum 50.6 3 HL3-50-200 N or LP *200,000 145,000 50-9 **27-5 235 N/A 17 to 35 Titan Alum 50.6 2 HL3-60-150 N or LP *150,000 100,000 60-5 32-5 265 330 16 to 30 Titan Alum 60.7 2 HL3-60-175 N orlp *175,000 125,000 60-5 32-5 265 N/A 16 to 30 Titan Alum 60.7 2 HL3-60-200 N or LP *200,000 145,000 60-5 32-5 265 N/A 17 to 35 Titan Alum 60.7 2 HL3-70-175 N or LP *175,000 125,000 70-1 **37-3 300 N/A 19 to 42 Titan Alum 70.9 2 HL3-70-200 N or LP *200,000 145,000 70-1 **37-3 300 N/A 19 to 42 Titan Alum 70.9 2 * Model requires stainless steel tube clamp (P/N: TP-220) to be located at the seam between the primary combustion chamber and the secondary combustion tube downstream of the burner control box. ** Model requires 5EA-SUB accessory package when installing in a U configuration (P/N: TF1B). IMPRTANT: Reference box label to determine the number of required baffle sections for each model heater. Titan = Black coated titanium stabilized aluminized steel. Alum = Black coated aluminized treated steel. 10

2.0 Installation Tube Sequence Heater Length Tube Installation Sequence Figure 2.4 Tube Installation Sequence Important! The combustion chamber & radiant tube sections must be installed in the following order. 20 Foot 30 Foot 40 Foot Stainless steel clamp location on 150-200 MBH models (P/N: TP-220). 50 Foot Stainless steel clamp location on 150-200 MBH models (P/N: TP-220). 60 Foot Stainless steel clamp location on 150-200 MBH models (P/N: TP-220). 70 Foot Key Burner Control Box with 16-inch Burner Tube Black Coated Combustion Chamber Tube* Black Coated Aluminized Combustion Chamber/Radiant Emitter Tube Standard Tube Clamp Stainless Steel Tube Clamp (P/N: TP-220) 150-200 MBH models only - Located between 1st and 2nd 10 ft. tube sections. Baffle Location *Aluminized tubes (50,000 to 125,000 BTU/H models); Titan tubes (150,000 to 200,000 BTU/H models). NTE: Refer to the Tube Heater eneral Manual, Chart 3.6 (page 23) for secured reflector joints. 11

3.0 peration Sequence of peration Thermostat 3.0 peration! ARNIN te: Reference the Tube Heater eneral Manual for installation requirements. Sequence of peration Standby: The 35-66 control continually checks for internal faults, circuit integrity and relay contact positioning. Starting Circuit: Upon a call for heat, the control verifies that the differential switch is in the proper position (open). The control energizes the fan. nce operational static pressure is achieved, the differential switch will close initiating the ignition sequence. The glo-bar is powered and the gas valve opens after 45 seconds. If the flame is not sensed, the heater will attempt to re-ignite for a total of three (3) trials for ignition before proceeding to soft lockout. Single Stage Running Circuit: After ignition, the flame rod monitors burner flame. If sense of flame is lost, the control closes the gas valve within one second and a new trial sequence (identical to the starting sequence) is initiated. If flame sense is not established within 8.5 seconds, the heater will attempt two (2) additional ignition sequences before proceeding to soft lockout. The control can be reset by briefly interrupting the power source. Two Stage Running Circuit: The second stage on the gas valve is powered directly from the second stage of the thermostat. In order for two stage to flow to a higher output, single stage must be energized as well. The thermostat determines which stage to maintain for the desired temperature. Shut Down: hen the thermostat is satisfied, the fan will enter a two (2) minute post-purge cycle. Refer to Soft and Hard Lockout under Diagnostics; p. 13. Thermostat This heater must be installed and serviced by trained gas installation and service personnel only. Do not bypass any safety features or the heater s built in safety mechanisms will be compromised. heaters require a 24VAC, two-stage thermostat to operate. The burner control box is equipped with a round terminal strip that accepts three (3) 1/4 insulated female spade terminals. Do not supply 120V to the 24V connection. The is equipped with or without relays (P/N: HLRP). The optional relays must be factory installed. NTE: Units with a relay installed must have an external transformer (field supplied), see wiring diagram. (Figure 2.2B). Standard Configuration ithout relays (identified with white label around the terminal block): Single burner control box. Single thermostat. 24V - 24V HEATER UTPUT - HIH L 24V UT ptional Configuration ith relays (identified with orange label around the terminal block): A single thermostat controls two or more burner control boxes. Heaters are common vented. Must be factory installed. 12

- 120V HEATER INPUT - - 24V HEATER INPUT - HT NEUTRAL EARTH HIH L NEUTRAL 3.0 peration Diagnostics Diagnostics Lockout: The controls will automatically lockout the heater system when an external or system fault occurs. There are two types of lockout: Soft Lockout: The heater will attempt to light three times. In the event of a failed attempt to light, (gas pressure, valve, no flame sense etc.), the heater will enter a soft lockout period for 15 minutes and then attempt to light three more times before entering Hard Lockout mode. Hard Lockout: If proof of flame is not established, a component failure occurs or blockages are evident, the heater will enter hard lockout. If lockout occurs, the control can be reset by briefly interrupting the power source. Refer to Chart 3.1 below for a description of LED codes. Figure 3.1 perational Indicator Lights 120V 24V Light 1 (amber) Indicates Low Fire Mode Light 2 (amber) Indicates High Fire Mode Light 3 (green) Indicates Pressure Switch Closes perational Indicator Lights Chart 3.1 LED Fault Code Status (located internally on circuit board) LED Code Fault Status Fault Code Delay* Initial flash on power up, then steady off fault, normal operation delay Steady N Module failure / Internal fault delay 1 flash Ignition failure 3 minutes 2 flashes APS (Air Proving Switch) (Fan / Intake / Exhaust) 0-30 seconds 3 flashes Lockout 17 minutes 4 flashes Solenoid valve fault Leaky valve Flame amplifier fault delay flash on 117V startup Transformer fault delay *Some LED codes have a time delay before the LED will flash. 13

4.0 Troubleshooting uide 4.0 Troubleshooting uide Turn up thermostat. Does the fan blower turn on? Is the power at the heater 120V? Does the heater have HLRP isolation relays? (identified with orange crescent around the terminal plug). Find the source of the electrical problem between panel and heater. Troubleshooting with ptional HLRP Isolation Relays Find the source of the electrical problem between panel and external transformer. External transformer is faulty and must be replaced. Is there 120V on the primary side of the external transformer? Is there 24V on the secondary side of the external transformer? Is there 24 Volts from the thermostat? Is there 24V to the thermostat? Find source of electrical problem between the external transformer and thermostat. The thermostat or wiring is faulty and should be replaced or repaired. Does the switch light energize? Is the green light burnt out? If so, replace. Is the inlet or the outlet of the unit plugged or obstructed? Repair the wiring between the transformer and the 24V terminal plug. Is there 24V on the secondary side of the transformer? Replace transformer. Is there 120V on the primary side of the internal transformer? Is the power across the left terminal of the 24V plug and ground 24 Volts? Repair the wiring between power in and transformer. Does the igniter warm up and glow red? Continued on page 16 Is the igniter physically damaged? Replace igniter. Check voltage at igniter Is the inlet or the outlet sequence (usually 5 to 15 of the unit plugged or seconds after power to obstructed? heater). Is it 120V? Is the resistance through the igniter 50-400Ω? 14 Remove obstruction.

NTICE 4.0 Troubleshooting uide Bypassing any switch is intended for testing purposes only. Do not leave switch bypassed during normal operation or the heater s built-in safety mechanisms will be compromised. ithout HLRP Isolation Relays: Start Question Process Question Corrective Action Key ith HLRP Isolation Relays: Process Question Corrective Action Is the power across the 24V wire on the circuit board and ground 24V? Is the power across the t-stat wire on the circuit board and ground 24V? Is the circuit board sending 120V to the fan? Is the fan obstructed? Remove obstruction. The relay board is faulty and must be replaced. Is the pressure switch stuck in the closed position? Replace switch. Is there 120V on the primary side of the internal transformer? The internal transformer is faulty and must be replaced. The circuit board is faulty and must be replaced. Repair wiring between power in and transformer. The fan is faulty and must be replaced. Is the power across the middle (low) terminal of 24V plug and ground (screw on the Burner Control Box) 24 Volts? Repair thermostat or wiring from thermostat to heater. Check for loose wiring or restrictions in hose connections to pressure switch. Are they K? Replace wiring or hose connections. Is there 24V across the TH and ground terminals on the circuit board? Correct wiring. * Refer to LED diagnostic Fault Code Chart; p.13. *After 0-30 seconds of non-operation has passed, is there a flash code for APS failure (2 flashes)? Replace circuit board. Is the circuit board sending 120V to the fan? 15 Is the pressure switch stuck in the closed position? Is the fan obstructed? Replace pressure switch Remove obstruction. Replace the pressure switch after verifying: Baffle(s) are in the radiant tube furthest from the burner. Heater, fan blowers,squirrel cage, intake and exhaust are clean and free from dirt and obstructions. The 4 air intake pipe does not exceed 20 ft. and/or 2 elbows. There is not a negative pressure experienced at the area of air intake (e.g.; high winds, attic space, tightly sealed building).

4.0 Troubleshooting uide Continued from page 14 After igniter is warmed up, does gas valve open? Test for 24V at valve opening period (usually 45 to 60 seconds after power to heater). Is there 24V to valve for 8 seconds? Replace circuit board. Does The burner light? Is the ball valve/ shut-off valve in the N position? Check to make sure gas pressure is within minimum and maximum inputs, as indicated on the heater s rating plate. Is gas pressure K? Turn on. Correct problem. Does the burner stay on? Does the burner stay on for approx. 8 seconds and then shut off? Does the burner come on and turn off immediately (1 or 2 seconds)? Check to make sure gas pressure is within minimum and maximum inputs, as indicated on the heater s rating plate. Is gas pressure K? Pressure switch may be faulty or there is a restriction in the exhaust. Does the heater stay N until a call for heat ends? The heater can shut down due to: Improper grounding. High winds. Taking combustion air from the attic. Dirty environment. Improperly positioned baffles. Fluctuating gas pressure. Correct problem. Troubleshooting ends. 16

4.0 Troubleshooting uide Check to make sure gas pressure is within minimum and maximum inputs, as indicated on the heater s rating plate. Is gas pressure K? Replace gas valve. Correct problem. ere the gas lines purged of air? Purge gas line. Is the heater properly grounded? Is the heater s polarity correct? ith microampmeter, check DC amperage at flame rod. Is it greater than 1.0 microamps? Check to make sure flame sensor wire is K and then replace circuit. Correct problem. Sensing rod is faulty or flame is weak. Check to make sure heater is operating at proper gas pressure as indicated on the heater s rating plate and then, if needed, replace sensing rod. If heater does not go into high fire mode: NTE: To confirm that the heater is not in high fire mode, check manifold pressure. If manifold pressure is 3.3 to 3.5 for natural gas or 9 to 10 for propane, the light is faulty and should be replaced. hen the heater is in low fire mode, manifold pressure is approximately 2.0 to 2.5 for natural gas or 5.0 to 6.5 for propane. If this is the case, the following troubleshooting steps should be followed: Is there 24V across the RUND and HIH (HIH to CM on heaters with optional isolation relays) on the terminal strip located on the outside of the control box? Measure voltage across the red wire on the VALVE and RUND (red wire on RELAY to RUND on heaters with isolation relays). Is it 24V? Repair or replace faulty wiring or thermostat. Replace gas valve. Replace relay. 17

5.0 Parts Heater Components and Parts List 5.0 Parts Figure 5.1 Burner Assembly Components 3094 83 85 333 84 3002A 331 76 Chart 5.1 Parts List 70 3044 3099 3140, 3141 212 828 3060 245 25 3008A 3252 1325 68B 832 3098 332 219 826 851B 3010 3033C 1428 70A 331 204 31D 3097 3011 222 206 3096 221 222A 383 3012 50 217 321 205 3001 3094A 3005A 10A 9 1018 264D/F, 1264A 3093 18 3014 3004 Part # Description Part # Description 5 3072, 3071, 201B 55A 14 15 16 3003A TP-5 Flange asket TP-70 1/2 in. Control Box asket (10.3 inches) TP-9 Conduit Coupling TP-70A 1 in. Control Box asket (6 inches) TP-10A Conduit 4 x 3/4 TP-76 Rubber rommet TP-14 Sight lass asket TP-82 Reflector Center Support (RCS) TP-15 Sight lass TP-83 24 in. Stainless Steel Flexible as Connector TP-16 Sight lass asher TP-84 1/2 in. Female / Male Flare Fitting TP-17 Sight lass Kit TP-85 1/2 in. Male / Male Flare Fitting TP-19B 4 in. ire Hanger with Tension Spring TP-105 Aluminum Reflector End Cap TP-20C 120 in. Aluminum Reflector TP-106 Reflector End Cap Clips (8 pcs.) TP-20D* 120 in. Stainless Steel Reflector TP-113 Reflector Tension Spring TP-21B 4 in. Standard Tube Clamp TP-201B V.3 Mid Burner (Color Code - TAN) TP-25 1/4 in. Female Spade Terminal (Qty. 3) TP-204 as rifice (consult factory) TP-26A 10 ft. Aluminized Radiant / Combustion Tube TP-205 lo-bar Holder TP-26B 10 ft. Titanium Coated Combustion Tube TP-206 lo-bar Holder Spring Clip TP-26D* 10 ft. 304 Stainless Steel Radiant Tube TP-212 1/2 x 3 Pipe Nipple TP-26E* 10 ft. 409 Stainless Steel Combustion Tube TP-217 Brass Pressure Switch Barb Fitting TP-31D Interlocking Mounting Bracket (Qty. 2) TP-219 Differential Vinyl Sensing Tube (burner) TP-50 lo-bar Igniter TP-220 Stainless Steel Tube Clamp (150 & 200 MBH) TP-55A Fan Blower TP-221 lo-bar Holder asket TP-65I 36 in. Interlocking Turbulator Baffle TP-222 Flame Rod TP-68B Large Strain Relief Bushing TP-222A Flame Rod ire * ptional upgrade or add-on item. 21B 3380 17

5.0 Parts Heater Components and Parts List Figure 5.2 Tube & Reflector Components 20C/D* 105 106 82 113 579 19B 105 26A/D* 26A/B/E* 21B, 220 65I Part # Description Part # Description TP-245 3/16 X 1/8 Plastic as Valve 90 Vent TP-3008A as Valve Mounting Bracket TP-264D Differential Pressure Switch, 65 to 75 MBH TP-3010 Service Panel Hinge TP-264F Differential Pressure Switch, 150 to 200 MBH TP-3011 V.3 Igniter Box TP-321 Ignition Plate asket TP-3012 V.3 Igniter Box Cover TP-331 reen Self-Tap round Screw (Qty. 2) TP-3014 Plastic Air rifice with Screen TP-332 Divider rommet TP-3033C HL3 Power Entry Plate TP-333 72 in. Black 120V Power Cord TP-3044 as Manifold TP-383 lo-bar Igniter Plate TP-3060 V.3 Pressure Switch Mounting Bracket TP-579 4 in. ire Hanger w/o Tension Spring TP-3071 High BTU Burner (Color Code - PURPLE) TP-826 40VA Transformer TP-3072 Low BTU Burner (Color Code - REEN) TP-828 24V Yellow perational Indicator Light (Qty. 2) TP-3093 #8-23 Cage Nut (Qty. 4) TP-832 Thermostat Terminal Strip TP-3094A #8-32 x ½ Zinc Coated Steel Knurled Thumb TP-851B 35-66 Diagnostic Circuit Board Screw (Qty. 4) TP-1018 Differential Switch Vinyl Sensing Tube (exhaust) TP-3096 Valve Compartment Bottom Panel TP-1264A Differential Pressure Switch, 100 to 125 MBH TP-3097 Valve Compartment Top Panel TP-1325 ptional HLRP Isolation Relay* (Qty. 2) TP-3098 Valve Compartment Side Panel TP-1428 24V reen perational Indicator Light TP-3099 Controls Mounting Panel TP-3001 Divider Panel TP-3140 3654-224 as Valve - Natural as Assembly TP-3002A Plastic End Panel, Control Compartment TP-3141 3654-226 as Valve - LP as Assembly TP-3003A Plastic End Panel, Fan Compartment TP-3252 4-Piece ire Harness Set TP-3004 V.3 Control Box TP-3380 V.3 16 HSI Burner Tube w/ Flange and Fittings TP-3005A Plastic Valve Chamber Lid * ptional upgrade or add-on item. 19

Kit Contents Check List Kit Contents Check List Kit Contents - Reference the length column for your model. TP-19B 4 Hanger with Reflector Tension Spring TP-82 4 Reflector Center Support (RCS) Kit Contents TP-105 Reflector End Cap TP-106 Reflector End Cap Clips TP-25 1/4 Female Spade Terminal **TP-19C **TP-829 **TP-105A TP-83 24 Stainless Steel Flexible as Connector TP-220 4 Tube Clamp LIT3 eneral Manual Tube Heater eneral Manual LIHL3 Insert Insert Manual Part. Description 20 ft. 30 ft. 40 ft. 50 ft. 60 ft. 70 ft. TP-19B 4 Hanger w/ Tension Spring 3 4 5 6 7 8 TP-21B 4 Tube Clamp 2 3 4 5* 6* 7* TP-25 1/4 Female Spade Terminal 3 3 3 3 3 3 TP-82 4 Reflector Center Support 2 3 4 5 6 7 TP-83 24 S.S. Flexible as Connector 1 1 1 1 1 1 TP-105 Reflector End Cap 2 2 2 2 2 2 TP-106 Reflector End Cap Clips 8 8 8 8 8 8 LIT3 V3 eneral Tube Heater Manual 1 1 1 1 1 1 LIHL3 Insert Manual 1 1 1 1 1 1 Filled By: **TP-83A **TP-220 * NTE: ne 4 stainless steel tube clamp (P/N: TP-220) is provided for each 150,000-200,000 BTU/h model. Place as shown on page 11. ** Part number for models upgraded with stainless steel options. Approvals CSA. Indoor approval. utdoor approval with D-Kit. Commercial approval. Limited arranty 1 year - Burner box components. 5 years - Combustion and radiant tubes. 10 years - Stainless steel burner. See page 36 of the eneral Tube Heater Manual for terms and conditions. 2013 Detroit Radiant Products Co. 21400 Hoover Road arren, MI 48089 Phone: (586) 756-0950 Fax: (586) 756-2626 www.detroitradiant.com sales@drp-co.com Printed in U. S. A. 20