COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions. WARNING! For Outdoor Use Only.

Similar documents
COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions. WARNING! For Outdoor Use Only.

RETRACTABLE. Expand your life

Commercial PATIO HEATER

Patio Heater_ _V4_ENG.book Page 1 Tuesday, September 2, :00 AM. AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

Outdoor Flame Heater

INSTALLATION INSTRUCTIONS AND OWNER S MANUALS

AXIS OUTDOOR HEATER. Owner s Manual DANGER WARNING

User Manual No. 8 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

User Manual No. 5 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

Owner s Manual. 36" Square Gas Fire Pit Model#SRGF11610 DANGER WARNING. WARNING: For Outdoor Use Only.

35" Square Gas Fire Pit Model#SRGF11603B

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

User Manual No. 1 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , , OUTDOOR PATIO HEATER

Assembly Instructions & User s Manual

Owner s Manual TABLETOP PATIO HEATER MODEL # PHRDGH/SS-TT

Owner s Manual M odel # F-1350-FPT OUTDOOR FIRE PIT TABLE

BRONZE HSC PATIO HEATER. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG195H

Outdoor Patio Heater

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

TABLE TOP PATIO HEATER Owner s Manual

Wine Barrel Fire Pit. Owner s Manual. Item # 9716 DANGER

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

GAS-FIRED INFRARED OUTDOOR PATIO HEATER INSTALLATION, OPERATION MAINTENANCE INSTRUCTIONS

TERRACE AND PATIO HEATER

ANS Z , Outdoor Decorative Gas Appliances CGA CR Outdoor Gas Fireplaces

TERRACE AND PATIO HEATER

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # ZCV-2670-SS

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

User Manual No. 6 WARNING. WARNING: For Outdoor Use Only WARNING DANGER. Models: , OUTDOOR PATIO HEATER

GAS PATIO HEATER WITH LED TABLE. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG188H

Owner's Manual. OUTDOOR FIRE PIT TABLE Item # 62145

OUTDOOR FIRE PIT FPS-DGHSS. ANS Z , Outdoor Decorative Gas Appliances CGA CR Outdoor Gas Fireplaces

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

Outdoor Patio Heater

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL:PHTRGH/SS MADE IN CHINA

Table Top Patio Heater

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

USE AND CARE GUIDE PEDESTAL FIREBOWL

Red Ember Outdoor Patio Heater with Table

Owner s Manual DANGER WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER

Comfort, Quality & Style Since 1998

OUTDOOR PATIO HEATER WARNING. WARNING: For Outdoor Use Only WARNING DANGER DANGER MODEL #GS-2400-BRZ GS-2400-BLK GS-2650-SS

Owner s Manual OUTDOOR LIVING PERFECTED TONGA TORCH PORTABLE PROPANE

Owners Manual Manual del Usuario

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # HSS-RS-TB

Using it in an enclosed space can kill you.

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Natural Gas Patio Heaters

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

Outdoor Patio Heater INFRARED BURNER

Aluminum Linear Fire Table

MODEL: CGG-306 Chef s Style Portable Tabletop Grill ASSEMBLY AND OPERATING INSTRUCTIONS

FLAME HEATER PYRAMID CLFH-10SS OPERATION INSTRUCTIONS

Outdoor Patio Heater INFRARED BURNER Model # LIP-10A-TGG-LPG-SP Item # 01775

Outdoor Patio Heater INFRARED BURNER

Patio Heater Model No. GM and GM

OWNER S MANUAL DANGER WARNING. WARNING: For Outdoor Use Only WARNING PATIO HEATER MODEL # HLDS01. Français p. 22. p. 43

Propane Tabletop Patio Heater

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING LAVA LITE KD

Assembly Instructions & User's Manual

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

ASSEMBLY INSTRUCTIONS

Dashley Outdoor Fire Table

Stoneridge Fire Pit High Dining Table Assembly Instruction

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OUTDOOR FIRE PIT ITEM # 61860

ASSEMBLY INSTRUCTIONS

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance.

Owners Manual Manueal d Utilisation

Serial Number Purchase Date

CYLINDER NOT INCLUDED

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Flame Heater PH08 SERIES

Owner's Manual OUTDOOR FIRE PIT TABLE ITEM # 62195

Owner s Manual. WARNING: For Outdoor Use Only

Comfort, Quality & Style Since 1998

OUTDOOR FIRE PIT TABLE ITEM # 62082

Outdoor Patio Heater Instruction Manual Model# PH01-S, PH01-SS Item # 60788,60368,60485,60786,61185,61444,61546,61547

OUTDOOR PATIO HEATER MODEL #HSS-RS-GH. Model: HCPH MRKT / HCPHSSRKT

USE AND CARE MANUAL. Home Garden. For Model T87PHLP. Stop! Missing a part? DO NOT RETURN PRODUCT TO STORE

ANSI Z /CSA Gas-Fired Outdoor Infrared Patio Heaters. ANS Z /CSA Gas-Fired Outdoor Infrared Patio Heaters

Warning: For OUTDOOR USE only

Owner s Manual OUTDOOR FIRE PIT ITEM # 61168

OWNER S MANUAL DANGER WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR GAS FIREPIT MODEL # AFP-RT

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING LAVA LITE

OPERATING INSTRUCTIONS AND OWNERS MANUAL GAS-FIRED INFRA-RED TANK TOP HEATER

LAVA 2G. 66,000BTU Instruction Manual. Outdoor Flame Heater. New Model YEAR I G N D E S E R T I E D

Area Heater AH100 Series

OPERATING INSTRUCTIONS AND OWNER S MANUAL

These instructions are for your safety. Please read them thoroughly before use and retain them for future reference

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

PAULIN PRODUCTS INDOOR HEATER

Owner s Manual Patio Heater. Product Code: UPC Code: Date of Purchase: / /

LP GAS PIZZA OVEN USER MANUAL

For assistance with assembly, please contact Hayneedle Customer Care Center

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

WARNING. SPECIFICATIONS: Completely Self-contained Rain Protected Wind Resistant No Electrical Required WARNING FOR OUTDOOR USE ONLY!

Outdoor Tabletop Heater TTH20 Series

Transcription:

COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions WARNING! For Outdoor Use Only. WARNING! Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. Save these instructions for future reference. Please ensure the owner of the heater retains the manual for future reference. ANS Z83.26-2007 / CSA 2.37-2007 Gas Fired Outdoor Infrared Patio Heater 5510_USA_Trendstyle_QC_161209.indd 1 07.01.10 11:55

WARNING FOR YOUR SAFETY If you smell gas: 1. Shut off the gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department. WARNING FOR YOUR SAFETY 1. Gas leaks may cause a fire or explosion which can cause serious bodily injury, death or damage to property. 2. You must follow all leak checking procedures as outlined in step 8 before operating this unit. 3. Never use an open flame to check for leaks. WARNING California Proposition 65: Chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm are created by the combustion of propane. WARNING - Purchaser assumes all risk in the assembly and operation of this unit. Failure to follow this manual s WARNINGS and instructions can result in severe personal injury, death or property damage. - Do not use in an explosive atmosphere. Keep heater away from areas where flammable liquids, gasoline, vapours, or explosives are stored or used. WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinty of this or any other appliance. WARNING Beware of sharp edges, ensure gloves are worn on assembly. 2 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 2 07.01.10 11:55

TABLE OF CONTENTS Page 1 SAFETY FIRST 4-5 2 ASSEMBLY INSTRUCTIONS in 11 steps 6-13 3 OPERATION 14 3.1 BEFORE TURNING GAS SUPPLY ON 14 3.2 BEFORE LIGHTING 15 3.3 LIGHTING 16 3.4 WHEN HEATER IS ON 16 3.5 RE-LIGHTING 16 3.6 SHUTDOWN 16 4 OPERATION CHECKLIST 17 5 CLEANING & MAINTENANCE 18 6 STORAGE 18 7 SPECIFICATIONS 19 8 WARRANTY 19 9 SERVICE ADDRESS 19 The use and installation of this product must conform to local codes. In absence of local codes, use the National Fuel and Gas Code, ANSI Z223, 1/NFPA 54, Storage and Handling of Liquid Petroleum Gases, ANSI/NFPA 58 or CSA B149.1, Natural Gas and Propane Installation Code. The installation must confirm with local building codes or, in the absence of local codes, with the current CAN 1-B149 installation codes. THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURE`S AUTHORISED REPRESENTATIVE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES Owners manual: model 5510 outdoor patio heater 16-12-2009 3 5510_USA_Trendstyle_QC_161209.indd 3 07.01.10 11:55

1. SAFETY FIRST! Read and become familiar with this entire manual especially the following precautions. If you are unsure of anything in these instructions, STOP and contact for assistance. Caution: This application is for outdoor use only (outside any enclosure). Always make sure there is fresh air ventilation. Ceiling 36 " Always maintain at least 36 clearance (top) and 24 clearance (side) from combustible materials. Always place heater on a hard and level surface and mounted. Do not use if the wind velocity is greater than 10 miles per hour. Unit will operate at reduced efficiency below 40 F (5 C). Keep sprinklers and other water sources away from burner and controls. Always use extreme caution when near heater. Alert both children and adults to the hazards of high temperatures, especially to avoid burns or clothing catching fire. 24 " Young children and pets should be carefully supervised when they are in the area of the heater. Do not hang clothing or other flammable materials either on or near the heater. Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater. Wall Certain materials or items, when stored under the heater, will be subjected to radiant heat and could be seriously damaged. Do not alter heater in any manner. The pressure regulator and hose assembly supplied with the appliance must be used and replacements must be those specified by the manufacturer. If regulator becomes damaged, use only a factory-supplied replacement. lnspect heater before each use. If a damaged part is detected, do not operate until an original equipment replacement part has been properly installed. Use of unauthorized parts will void warranty and create an unsafe condition. Please call 847 850 5335 for help! Prior to operating the heater, replace any guards or protective devices removed for servicing. During operation, do not touch the burner assembly. The surface of the heater s emitter can reach temperatures approaching 1600 F After shutdown, do not touch the burner assembly until the heater has cooled (approximately 45 minutes after use). Notice: This product should not be used with any fuel other than liquid propane. Use of other fuels will detract from the heaters performance and will void your warranty. The used LP-gas cylinder must be: a Constructed an marked in accordance with the Specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT); or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commisiion, CAN/ CSA-B339, as applicable; b Provided with a listed overfilling prevention device; and c Provided with a cylinderconnection device compatible with the connection for the appliance. Storage of an appliance indoors is permissible only if the cylinder is disconected and removed from the appliance. A cylinder must be stored outdoors in a well ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed and must not be stored in a building, garage or any other enclosed area. Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond 80 percent full. If the information above is not followed exacly, a fire causing death or serious injury may occur. 4 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 4 07.01.10 11:55

Caution: Liquid propane (LP) gas is flammable and hazardous if handled improperly. Become aware of the characteristics before using any LP product. LP Characteristics Flammable, explosive under pressure, heavier than air - settles in pools in low areas. In its natural state, propane has no odor. For your safety, an odorant is added and has a bad smell. Contact with LP can cause freeze burns to skin. This heater is shipped from the factory for LP gas use only. Use only Department of Transportation (DOT) approved 20 Ib. LP gas tanks (Same as those commonly used on gas grills) with Acme / Type 1 / QCC safety valves. These valves can be quickly identified because they have external and internal threads. Never use an LP tank with a damaged body, valve, collar, or foot ring. Dented or rusted LP tanks may be hazardous and should be checked by your LP gas supplier. The tank supply system must be arranged for vapour withdrawal. The tank used must include a collar to protect the tank valve. When heater is not in use, turn LP tank 0FF. Always perform a leak test on gas connections whenever a tank is connected. Never use a flame to test for leaks. Do not smoke while performing a leak test. Caution: It is essential to keep the heater s valve compartment, burners, and circulating air passages clean. Spiders and insects can create a dangerous condition that may damage the heater or make it unsafe. Keep the burner area clean of all spiders, webs, or insects. lnspect the heater before each use. Have heater inspected annually and repairs should be made by a qualified service person. Check the heater immediately if any of the following conditions exist: The smell of gas in conjunction with extreme yellow tipping of burner flames. Heater does not reach the proper temperature. Note: At temperatures less than 40 F, heat output will be reduced. Heater s glow is excessively uneven Burner makes popping noises during use. FOR YOUR SAFETY BEARE OF SPIDERS Spiders or small insects can get into the burner tube or other openings of your heater and spin webs or build nests. These obstructions can lead to gas flow problems. It is important to make frequent inspections of these areas and clean them when necessary. Before operating your heater for the first time, be sure to check for obstructions that may have occurred during shipment. Note: A slight pop is normal when burner is extinguished. Carbon deposits may create a fire hazard. Keep dome and emitter clean at all times. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water. Do not paint the burner, the burner access panel or dome. Owners manual: model 5510 outdoor patio heater 16-12-2009 5 5510_USA_Trendstyle_QC_161209.indd 5 07.01.10 11:55

2. ASSEMBLY INSTRUCTIONS 8 mm 10 mm 6 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 6 07.01.10 11:55

1 6 19 1x 2 3 4 5 7 2 x 8 2 x 18 3x 12 9 10 11 20 13 3x 14 3x 15 14x 16 16x 17 Owners manual: model 5510 outdoor patio heater 16-12-2009 7 5510_USA_Trendstyle_QC_161209.indd 7 07.01.10 11:55

To avoid cuts, you have to wear safety gloves during installation. Get help by a second person during the installation. Remove the protective foil from all parts first! 7 8 16 4x 6 2 15 9 10 11 8 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 8 07.01.10 11:55

3 15 12 15 4 3 6 3 15 Owners manual: model 5510 outdoor patio heater 16-12-2009 9 5510_USA_Trendstyle_QC_161209.indd 9 07.01.10 11:55

5 1 13 14 6 17 10 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 10 07.01.10 11:55

7 3 17 5 8 15 3x Quick connector 15 3x Owners manual: model 5510 outdoor patio heater 16-12-2009 11 5510_USA_Trendstyle_QC_161209.indd 11 07.01.10 11:55

9 20 gas bottle not included in delivery!! Attatching gas bottle & LEAK CHECKING view page 14+15 10 18 3x 12 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 12 07.01.10 11:55

11 19 Owners manual: model 5510 outdoor patio heater 16-12-2009 13 5510_USA_Trendstyle_QC_161209.indd 13 07.01.10 11:55

3. OPERATION Caution: Do Not attempt to operate the heater until you have read and understood the warnings section in this manual. MOUNT THE HEATER ON THE GROUND FIRST! 3.1 TURNING THE GAS SUPPLY ON CONNECT THE GAS HOSE AND REGULATOR ASSEMBLY TO THE TANK Note: Use only a Department of Transportation (DOT) approved 20 pound cylinder with an ACME/ Type 1 connection with QCC (Quick Connect Coupler)safety valves. When the Cylinder is empty it should wheight 18 pounds. CHECK FOR LEAKS: Make a solution of 2-3 oz. of leak checking solution by mixing one part liquid dishwashing soap and three parts water. Follow the procedure below: LEAK CHECKING FUEL TUBE CONNECTION Step 1: Turn cylinder valve on by turning anti-clockwise. Step 2: Check fuel tube connection for leaks. To check for leaks spoon several drops of solution onto the connections as illustrated. Step 3: Inspect the solution for bubbles. If no bubbles appear then the connection is secure. If bubbles appear, then there is a leak: Turn OFF the cylinder valve. Undo the connection and inspect the surface of the cone to make sure they are clean. Reconnect by using two wrenches, one on either side of the connection. Repeat the leak checking procedure described above. If you still see bubbles after several attempts DO NOT USE THE HEATER. Contact service for assistance. 14 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 14 07.01.10 11:55

LEAK CHECKING GAS LINE AND CYLINDER CONNECTIONS Step 1: Turn cylinder valve on by turning anti-clockwise. Step 2: Check connections and valve for leaks. To check for leaks spoon several drops of solution onto the connections as illustrated. Step 3: Inspect the solution for bubbles, if no bubbles appear then the connection is secure. If bubbles appear, then there is a leak: Turn OFF the cylinder valve. Release the regulator connection to the cylinder. Reattach the regulator, making sure that the connection is tight. Repeat the leak checking procedure described above. If you still see bubbles after several attempts DO NOT USE THE HEATER. Contact service for assistance. X - Your heater was designed and approved for Outdoor use only. Do NOT use it inside an enclosure. - Make sure that all combustibles are maintained X and that there are no flammable liquids or vapors in the vicinity of the heater. - Make sure there is no obstruction to air ventilation. - Be sure that all gas connections are tight and there are no leaks. - Any components removed during the assembly or servicing of the heater must be reinstalled. X X X 3.2 BEFORE LIGHTING - The heater components should be thoroughly inspected before each use and at least every two years by a qualified service person. - Inspect the visible portion of the hose before each use of the appliance. Portions that are located within the heater post, inspect the entire hose assembly at least annually. - The hose assembly must be replaced prior to the appliance being put into operaton if there is evidence of excessive abrasion or wear, or if the hose is damaged. The replacement hose assembly shall be that specified by the manufacturer.! LEAK CHECKING view page 14 Owners manual: model 5510 outdoor patio heater 16-12-2009 15 5510_USA_Trendstyle_QC_161209.indd 15 07.01.10 11:55

3.3 LIGHTING 1. Push control knob IN and turn to OFF. 2. Turn the gas tank valve ON. 3. Depress the burner control knob and turn it (anticlockwise) to the igniting position. 4. Press the piezo-ignition concurrently with your other hand and hold the pressed knob for about 10 seconds after ignition in order to activate the ignition safety switch. Should the gas fail to ignite after pressing the piezo-ignition 3 or 4 times, leave the appliance for about 5 minutes that any gas to clear and then repeat the process. WARNING FOR YOUR SAFETY Be careful when attempting to manually ignite this heater. Holding in the control knob for more than 5 seconds before igniting the gas will cause a ball of flame upon ignition. Note: It is possible to ignite the burner using other ignition devices (gas lighters, matches) through the 0.73 inch aperture in the bottom of the burner. Caution: Avoid inhaling fumes emitted from the heater s first use. Smoke and odour from the burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should NOT produce thick black smoke. Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the burner, turn the Control Knob to the small flame position. Then, turn the knob to the level of heat desired. 3.4 WHEN HEATER IS ON Emitter screen will become bright red due to intense heat. The colour is more visible at night. Burner will display tongues of blue and yellow flame. These flames should not be yellow or produce thick black smoke, indicating an obstruction of airflow through the burners. The flame should be blue with straight yellow tops. 3.5 RE-LIGHTING Turn Control Knob to 0FF Wait at least 5 minutes, to let gas dissipate, before attempting to relight. Repeat the Lighting steps on prior page. 3.6 SHUTDOWN 1. Turn the burner control knob clockwise to the igniting position. 2. Depress the control knob and turn it clockwise to OFF. 3. Turn tank valve clockwise to OFF. Disconnect the regulator when heater is not in use. WARNING FOR YOUR SAFETY Heater will be hot after use Handle with extreme care Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided by the cylinder valve. Other types of caps or plugs may result in leakage of propane. 16 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 16 07.01.10 11:55

4. OPERATION CHECKLIST For a safe and pleasurable heating experience, perform this check before each use. BEFORE OPERATING I am familiar with entire owner s manual and understand all precautions noted in Safety First. All components are properly assembled, intact and operable. No alterations have been made. All gas connections are secure and do not leak. Wind velocity is below 10 mph. Outdoor temperature is greater than 40 degrees F. Heater is outdoors (outside any enclosure). There is adequate fresh air ventilation. Heater is away from gasoline or other flammable liquids or vapors. Heater is away from windows, air intake openings, sprinklers and other water sources. Heater is at least 36 clearance (top) and 24 clearance (side) of combustible materials. Heater is on a hard and level surface. There are no signs of spiders or insect nests. All burner passages are clear. All air circulation passages are clear. Children, pets, clothing, flammable materials and items that can be damaged from radiant heat are away from the heater. Children and adults in the area have been alerted to the high temperature hazards: especially burns and clothing fires. Children and adults in the area have been warned not to touch the heater near the burner during operation and until unit has cooled. AFTER OPERATION Gas control is in 0FF position. Gas tank valve is 0FF Disconnect Gas Line. Heater is upright in a secure location. Owners manual: model 5510 outdoor patio heater 16-12-2009 17 5510_USA_Trendstyle_QC_161209.indd 17 07.01.10 11:55

5. CLEANING AND MAINTENANCE Your heater has been produced from highly weather resistant materials and only minimum cleaning and maintenance is required. Cleaning must be performed when the heater is cold. Your patio heater will live longer if it is cleaned and maintained properly. It is very important that the air required for the combustion process is not blocked going to the burner. Vents and other openings must be kept free of dirt and spiders webs. The burner lower part is one unit. You can not clean it. Stainless steel models: Use a stainless steel cleaner product on the main components of the heater, cylinder cover, base and post. Never use a cleaning agent that is flammable or corrosive. Never spray any cleaning product on the emitter grid or burner area. Painted models: Wash all painted parts of the heater with a soapy solution and protect it with a coat of automobile car wax a couple of times per year or as required dependent upon your local weather and climate conditions. If you need to touch up a painted heater only paint the post and base portions. Never paint the emitter grid, lighting instructions, valve or control knob area or the LP cylinder! The burner ports must also be kept clear so that the burner burns evenly and the flow of gas is not restricted. If the heater is not performing adequately it will be necessary to check the burner. In a salt air or ocean enviroment, corrosion and rust occur at a far greater rate than in non-ocean areas. You will need to check more frequently for corrosion and replace parts as required. 6. STORAGE - Turn control knob OFF - Disconnect LP source and move to secure, well-ventilated location outdoors. - Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, snow, dust and debris). - If desired, cover heater to protect exterior surfaces and to help prevent build up in air passages. - Never leave the LP cannister exposed to direct sunlight or excessive heat. - Note: Wait until heater is cool before covering. - If using a cover, ensure is is tightly fitted or secured support it during high winds. 18 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 18 07.01.10 11:55

7. SPECIFIACTIONS Certifications: ANS Z83.26/CSA 2.37-2007 Gas Fired Outdoor Infrared Patio Heater Rating: Maximum 40,000 BTU/hr. input Heat Range: Up to 20 foot diameter Fuel: Liquid Propane Gas (LP) Tank Size: Nominal 20 lb / 5 Gallon Inlet gas supply pressure: Maximum 150 PSI Minimum 5 PSI Mainfold Pressure: 11.00 in.w.c. Safety Features: 100% Burner shut-off Tilt switch Manufacturer: Enders Colsman AG Made in: P. R. China 8. WARRANTY Correct functioning of the appliance is guaranteed for two years. The guarantee is dependent on proper handling of the appliance and official proof of the date of purchase. We reserve the right to make technical changes and changes to the colour. 9. SERVICE ADDRESS Distibutoys 650 South Wheeling Road Wheeling IL 60030 Tel 847 850 5335 Fax 847 850 5336 Mail enders@distributoys.com Owners manual: model 5510 outdoor patio heater 16-12-2009 19 5510_USA_Trendstyle_QC_161209.indd 19 07.01.10 11:55

ENDERS Colsman AG Brauck 1 58791 Werdohl-Kleinhammer GERMANY Phone: (0049)-(0) 23 92-97 82 31 Fax: (0049)-(0) 23 92-97 82 70 E-mail: info@enders-colsman.de Internet: www.enders-colsman.de ENDERS UK Ltd Unit 17, Glenmore Business Centre UNITED KINGDOM Range Road Witney, OXON OX29 0AA Phone: 0044 1993 708495 Fax: 0044 1993 704020 E-mail: info@endersltd.co.uk Internet: www.enders-colsman.de 20 Owners manual: model 5510 outdoor patio heater 16-12-2009 5510_USA_Trendstyle_QC_161209.indd 20 07.01.10 11:55