Application Note #603 Revision A June 2016 Lighting Control for Noise-Sensitive Applications

Similar documents
Application Note #109 Revision D December A Guide to Using Dimmable Receptacles. Overview. FAQs. 1 Technical Support

Application Note #407 Revision F March 2019

Meeting RF Performance Criteria...7 Background...7 Expectations...7 End-of-Line Testing...7 Fixture Control Self-Test...7 Basic Functionality...

Application Note #451 Revision B June 2012

Use this addendum with the LP Installer s Guide to install a. GRAFIK RP System

Venetian blindstm with Intelligent Tilt Alignment

Mitsubishi Electric Cooling & Heating System VRF -

2800 Series Control Units

fabric specification guidelines

Phase-Adaptive Power Module

centralised lighting control LCP128TM systems

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

myroomtm Operations and Maintenance MANUAL

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

EcoSystem H-Series Ballasts

Fluorescent Dimming Ballast Selection Guide Where to go next: Fluorescent Lighting Controls Selection Guide, pg.196

EcoSystem H-Series 347 V~ Ballast Overview

Ivalo Lumaris LED Linear Lighting

Ivalo Lumaris LED Linear Lighting

Lutron LED Drivers. Take control of the LED opportunity

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

ANSI/ASHRAE/IES

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

EcoSystem H-Series Ballasts Overview

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

Grüv Flare Regressed. Recessed Linear LED

Ivalo Lumaris LED Linear Lighting

ANSI/ASHRAE/IES

OPTIONS. Mounting LUMEN OUTPUT FLAT. 3000K lm/ft PERFORMANCE. Lumen Maintenance SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

OPTIONS. Mounting LUMEN OUTPUT. Flat. Round PERFORMANCE. Color Temperature. Lumen Maintenance Binning Tolerance Warranty + +

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

Grüv Flare Regressed. Recessed Linear LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

design guide for wireless l i g h t i n g c o n t r o l

Yoswit 0-10V / 1-10V / potentiometer / 10V PWM (3 in1 ) Constant Current Dimmer Driver

Vive PowPak Fixture Controls

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Maestro Dimmer - Satin Finish, Incandescent/Halogen, Single-Pole, Clamshell Packaging, 120V/600W In Biscuit

Increase your revenue with Caséta by Lutron Simple, reliable, affordable lighting control

HomeWorks QS Architectural RF GRAFIK T Local Controls

Performance Chart Electrical Data

Application Note #106 Revision D June Emergency Lighting. Overview

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

GRAFIK T Controls GRAFIK T

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Evoke 2.9" HP. 2.9" Square Downlight

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Evoke 2.9" HP. 2.9" Square Downlight

RA2 Select. Whole home lighting control made simple

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Classix 6" 6" Round Lens Wall Wash

Fino Healthcare. Asymmetric Wall Mount Indirect LED

CRENSHAW. LED Lamping Guide. Crenshaw LED. Farrell Hall, Wake Forest University

Evoke Square Adjustable HP

SPECIFICATION SUBMITTAL

Wireless Wall-Mount Sensor

Fino. Asymmetric Wall Mount Indirect LED

Classix 6" 6" Round Adjustable C3

Performance Chart Electrical Data

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Classix 6" 6" Round Adjustable C3M

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Hornet HP. Round Glass Downlight

HEP Tech Co., Ltd. Company Profile

Evoke Square Downlight

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Evoke Square Downlight

LED Control Solutions. Smooth, flicker-free dimming for every application

Velato. Recessed Slot Adjustable Multiples

Evoke Square Adjustable HP

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

Performance Chart Electrical Data

GRAFIK RA 2. Convenient, wireless light and blind control Integrates with leading smart home brands

Evoke Round Adjustable C3

Performance Chart Electrical Data

Linea 1.5. Linear Direct Wall Wash LED

Lutron In-Fixture Solutions Deliver a Beautiful Lighting Experience

SYSTEM. field cuttable LLED8000

SYSTEM. field cuttable. lipleds 8200 Series

Energi Savr NodeTM. A versatile, energy saving lighting control solution that is easy to install and easy to expand

Maestro 0 10 V Dimmer Sensor

Hornet HP. Square Glass Downlight

Evoke Square Adjustable C3M

Balance LC. classroom light control fixture solution. simple to order simple to install simple to use

A GUIDE TO HOME LIGHTING CONTROL. save energy with LutronTM

Performance Chart Electrical Data

Quick Install Energy Solutions Featuring Energi TriPak

Power Factor (1) 350 ma 90 ~ 132 Vac 34~68 Vdc 24 W 85% 0.95 LLC-024S035RSP. Max. Output Power. Efficiency (1)

Transcription:

Revision A June 2016 Lighting Control for Noise-Sensitive Applications MRI rooms, sound studios, and other noise-sensitive applications require very low-noise environments to preserve the integrity of the data collection in the room. Electrical noise created by alternating current linevoltage is of particular concern, even more so when that line-voltage is dimmed with a traditional phase-control signal. A better method of delivering power to the lights in a noise-sensitive application is to provide a directcurrent, or DC signal. Lutron has DC dimming solutions for both incandescent and LED load types. LED Loads For LED loads, Lutron recommends the Hi-lume 1% L3D or LTE LED Driver with Constant Current Reduction (CCR ) output. Lutron does NOT recommend the use of Pulse Width Modulation (PWM) output drivers. The 1% L3D or LTE LED driver is controllable with either a Lutron EcoSystem, Lutron 3-wire, or Lutron forwardphase control. The 1% L3D or LTE LED driver is mounted outside of the room and sends a direct-current signal to the LED load inside the room, through a recommended filter for enhanced noise filtering. The use of a filter does not negatively impact dimming performance. Refer to the Hi-lume 1% EcoSystemTM / 3-Wire L3D Driver specification submittal (Lutron P/N 369325) or the Hi-lume 1% 2-Wire LED Driver specification submittal (Lutron P/N 369543) for more information. If using Lutron controls with LED drivers by others, consult the driver or fixture manufacturer for filtering recommendations. In all cases it is recommend to keep Lutron dimming controls outside of the noise sensitive room. What is Constant Current Reduction (CCR)? In a CCR LED Driver, the output current flows continuously at a set amount for a given light level. Since the amount of light output is proportional to the current flowing through the LED, the current is reduced to reduce the brightness of the LED. See Lutron Application Note #360 for more information on the differences between CCR and PWM dimming of LEDs at http://www.lutron.com/technicaldocumentlibrary/048360.pdf What about 0-10 V- Controls? If using Lutron 0 10 V- controls to control 0 10 V- fixtures in a noise-sensitive application, Lutron recommends keeping all 0 10 V- controls outside of the noise-sensitive area. Furthermore, consult with the 0 10 V- driver or fixture manufacturer for filtering recommendations for the noise-sensitive application. 1 Customer Assistance 1.844.LUTRON1

LED Loads (continued) Important Design considerations: Lutron does NOT recommend the use of PWM output models of the 1% L3D or LTE LED driver for noisesensitive applications. These models dim the lights with a pulsed current output, which could create unwanted noise in a noise-sensitive application. Lutron recommends the use of LCR059 series of EMI filters (www.lcr-inc.com/pdf/mri-shielded-pdf/ LCR059SeriesInstallationInstructions.pdf) for use with the 1% L3D or LTE LED driver. The LCR059 sits on the output side of the driver, between the driver and the load. Lutron recommends using higher current, 500 ma, output models of the 1% L3D or LTE LED driver. The use of a filter causes some minor reduction in the current delivered to the load, which may be significant for currents below 500 ma. Consult the Lutron System Sales Engineering team for applications requiring lower currents. Any load that is compatible with a 1% L3D or LTE CCR driver that is 500 ma can also be used with the LCR059 filter. Keep in mind the maximum lead length from the driver to the LED load. Maximum Driver-to-LED Light Engine Wire Length for Constant-Current Drivers: Wire Gauge 200 ma to 700 ma Maximum Lead Length 710 ma to 1.50 A 1.51 A to 2.10 A 18 AWG (0.75 mm 2 ) 30 ft (9 m) 15 ft (4.5 m) 10 ft (3 m) 16 AWG (1.5 mm 2 ) 35 ft (10.5 m) 25 ft (7.5 m) 15 ft (4.5 m) 14 AWG (2.5 mm 2 ) 50 ft (15 m) 40 ft (12 m) 25 ft (7.5 m) 12 AWG (4.0 mm 2 ) 100 ft (30 m) 60 ft (18 m) 40 ft (12 m) 2 www.lutron.com/help

LED Wiring Overview Note: Colors shown correspond to the terminal blocks on the driver. Wiring Diagram for 3-Wire Control Switched Line/Hot (Black) +V 2 (Red) LCR059 Filter To 3-wire Dimming Control Dimmed Line/Hot (Orange) Neutral (White) Hi-lume 1% -V 2 (Black) LED light engine (Green) Wiring Diagram for EcoSystem Digital Control To Line Voltage Line/Hot (Black) Neutral (White) (Green) Hi-lume 1% +V 2 (Red) LCR059 Filter LED light engine -V 2 (Black) To EcoSystem Digital Link E1 (Purple) E2 (Purple) Controls Requiring Neutral Line LutronR Neutral-wire Forward Phase Dimmer Dimmed Line (Black) +V (Red) 2 Neutral Neutral Neutral (White) Hi-lume 1% 2-Wire LED Driver V (Black) 2 LCR059 Filter LED Light Engine Ground (Green) 1 1 Ground wire connection available on K-case models only. Fixture and driver case must be grounded in accordance with local and national electrical codes. 2 For maximum driver-to-led light engine wire length, see the Maximum Driver-to-LED Light Engine Wire Length for Constant-Current Drivers chart on page 3 of this document. 3 Customer Assistance 1.844.LUTRON1

Incandescent Loads For incandescent loads, Lutron recommends the DCI dimming panel (available for GRAFIK 4000 and Quantum systems). The DCI dimming panel is powered by 120 V~ and can power up to 3600 W of incandescent loads. The DCI dimming panel is mounted outside of the room and sends a direct-current signal to the incandescent lights in the room, through a filter designed specifically for the DCI panel to enhance noise filtering. The use of a filter does not negatively impact dimming performance. Refer to the DCI Dimming Panels specification submittal (Lutron P/N 369645) for more information. Important design considerations All power supplied into a noise-sensitive room must be fed through facility filters. Lutron DCI Panel solutions also require the following UL listed filter to be installed: FIL-COIL COMPANY, INC. P/N FC-2249 631.467.5328 Note: This is a custom filter designed specifically for DCI Panels. Other filters are not permitted unless each DCI circuit is supplied by a separate 120:120, 3.0 kva isolation transformer (one transformer is required for each power input). All Controls and Dimming Panels must be mounted outside the room, away from the influence of large magnetic fields (especially true in the case of an MRI room). 4 www.lutron.com/help

DCI Wiring Overview Wiring with Fil-Coil Facility Filter Input Feed 120 V~ * Incandescent Load Input Breaker DC Fuses * Facility Filter: Fil-Coil FC-2249 by others - one required per circuit Module Prewired by Lutron Wiring with any Facility Filter Input Feed 120 V~ Isolation Transformer by others * Incandescent Load Isolated Feed Input Breaker DC Fuses * Standard Facility Filter by others - one required per circuit Module Prewired by Lutron 5 Customer Assistance 1.844.LUTRON1

Lutron makes no guarantee for the total noise level in the room or the ability of the LED light engine to withstand the magnetic fields present in an MRI room. It is recommended to consult with the fixture manufacturer during the design phase of a project. Lutron suggests mounting any phase-control dimming or digital communication (EcoSystem, QS Link) wires at least 6 feet away from equipment that is sensitive to radio frequency interference. Lutron, EcoSystem, GRAFIK, Hi-lume, and Quantum are registered trademarks and EcoSystem is a trademark of Lutron Electronics Co., Inc. UL is a trademark of UL LLC. Lutron Contact Numbers WORLD HEADQUARTERS USA Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 TEL: +1.610.282.3800 FAX: +1.610.282.1243 support@lutron.com North & South America Customer Assistance USA, Canada, Caribbean: 1.844.LUTRON1 (1.844.588.7661) Mexico: +1.888.235.2910 Central/South America: +1.610.282.6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd. 6 Sovereign Close London, E1W 3JF United Kingdom TEL: +44.(0)20.7702.0657 FAX: +44.(0)20.7480.6899 FREEPHONE (UK): 0800.282.107 Technical Support: +44.(0)20.7680.4481 lutronlondon@lutron.com ASIAN HEADQUARTERS Singapore Lutron GL Ltd. 390 Havelock Road #07-04 King s Centre Singapore 169662 TEL: +65.6220.4666 FAX: +65.6220.4333 Technical Support: 800.120.4491 lutronsea@lutron.com Asia Technical Hotlines Northern China: 10.800.712.1536 Southern China: 10.800.120.1536 Hong Kong: 800.901.849 Indonesia: 001.803.011.3994 Japan: +81.3.5575.8411 Macau: 0800.401 Taiwan: 00.801.137.737 Thailand: 001.800.120.665853 Other Countries: +65.6220.4666 6 Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. P/N 048603 Rev. A 06/2016