PowerVac G Single to Twin Conversion Kit [ ]

Similar documents
Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

VetPro Solo Installation

Installation & Operation

Artizan Ortho-Pedo Bench Installation / User Manual

IMAGE V. Parts and Service Manual

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

TSS 15/55 Hi-Lift Vacuum

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

PRE-INSTALLATION GUIDE

LC Series - Light Commercial Pump Station Installation and Operation Manual

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Vacuum Plumbing Layout Recommendations

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

USER MANUAL/Installation Instructions LRV-4

Installation Instructions 30 French Door Built-in Wall Ovens

MODEL MW200 MODEL MW600 AIR DRYER

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Installation Manual PS-225 & PS-275

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Viking Installation Guide

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

A B A B4

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Installation Manual PS-200 & PS-201

INSTANT HOT WATER DISPENSER

Installation Instructions

Installation & Operating Guide

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

Model 1820 Dehumidifier

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

GCW SERIES Gas Cylinder Warmers

2 PREPARE THE OPENING

SAVE THESE INSTRUCTIONS

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

Water Boilers ME10EN, ME15EN. Table of Contents

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

BLAST-IT-ALL BUMPER BLASTER

XPS-ProDry User s Guide Dryer Base

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Top Control Dishwasher

INSTALLATION and OPERATING MANUAL TYPE: 120 VOLT IVD660-F IN-WALL INSTALLATION 66XF THE COMPACT CENTRAL VACUUM SPECIALIST. rev.:

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Artizan Ortho Cabinet Installation / User Manual

PRE-INSTALLATION GUIDE for MODELS

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

READ AND SAVE THESE INSTRUCTIONS

17 GALLON PROFESSIONAL RESTROOM CLEANER

690 Power Fishing System

Installation, Operating, and Maintenance Manual

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

HEATING AND AIR CONDITIONING

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Installation Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

DRAIN WATER TEMPERING INSTALL

690 and Power Fishing Systems

Operation and Maintenance Manual 120V/60HZ

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

Classic Twelve O clock Cabinet Installation Instructions

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Installation Instructions

High Output Vacuum/Pressure Pump

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

PRE-INSTALLATION GUIDE

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

Wrap-Around TOTE Tank / IBC Heaters. Instruction Manual. (TOTE and TOT Series) TOT Series. TOTE Series

INSTALLATION INSTRUCTIONS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

INSTALLATION INSTRUCTIONS

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Installation Instructions

WSK300 Multifunction Wall Control

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

Viking Installation Guide

Downdraft Ventilation

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Installation Instructions

Transcription:

PowerVac G Single to Twin Conversion Kit [002-1371-00] warning Motors are thermally protected with automatic reset. Unit may start without warning. Caution Vac unit weighs 375 lbs (170 kgs). Use care when moving to prevent personal injury. Raise leveling feet to roll base unit or use lift handles (77001455). Float Connection Inlet Hose From Operatory Connection Inlet Hose to Vac Unit Connection Vacuum Gauge Gasket Vacuum system must be installed per local plumbing and electrical codes. Do not operate without cover. Place vacuum system in a dry, well ventilated area on a solid, level surface. Verify all sides of base unit are not obstructed. Recommended - 6 inches on left and back side. Required - 12 inches on front and right side. Separator Front Cover Fasteners Connections for Remote Low voltage Wires, Float Cords Fan Plugs, Twin Paralleling, and Pressure Sensor Pre-Install, remove shipping bolts... A) Unfasten front cover by turning each fastener 1/4 turn, counter clockwise. B) Lift front cover straight up to remove from side panels. C) Loosen lock nut, remove bolts, set aside lock nut and replace front cover. Shipping bolts and nuts can be thrown away, they will not be reused. Drain Connection Base Unit 6" Base Unit 6" Hour Meter 12" 12" Shipping Bolts Level Feet Keypad Gear Lube Site Glass On / Off Switch 1 Style G 003-2026-00 Rev. HA1 (4/9/2018)

Important Information Intended Use To provide vacuum suction during general examinations and procedures conducted by qualified dental professionals. Electromagnetic Interference This Midmark PowerVac G is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and these units: Remove interfering device from room Increase separation between vacuum and interfering device Contact Midmark if interference persists Disposal of Equipment At the end of product life, the units, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods. Transportation / Storage Conditions Ambient Temperature Range:... 50 F to 104 F (+10 C to +40 C) Relative Humidity...10% to 90% (non-condensing) Atmospheric Pressure... 700hPa (20 Hg) to 1060hPa (31 Hg) Safety Symbols warning Indicates a potentially hazardous situation which could result in serious injury. Safety Symbols continued... Consult User Guide for important information. Proper shipping orientation Fragile Protective earth ground Keep Dry Maximum stacking height (palletted units) Fuse rating specification Caution Indicates a potentially hazardous situation which may result in minor or moderate injury. It may also be used to alert against unsafe practices IPXO Caution hot surface Ordinary Equipment Indicates a potentially hazardous situation which could result in equipment damage. 2

Plumbing Installation Verify all local codes before installing Inlet and Drain hoses. Termination of hoses to be provided by installer. Note Connections must be hand tight. May use mild soap for hose connections. Do NOT use glue on hose connections. Use glue ONLY on PVC connections. Tee Bracket Tee is Capped Caution Turn Power Off to existing Vac unit. On/Off switch only controls the secondary circuit power. Main Power Source must be turned off to remove all power in the control box. Tee Assembly Connect to Operatory Inlet Hose Twin Unit Plumbing... A) Lower level feet on base unit. Loosen nut on feet to lower leveling feet and raise casters and vac unit off floor. B) Mount tee assembly bracket, place tee assembly on bracket. C) Connect inlet hose from base unit to separator. D) Connect inlet hose from each separator to tee assembly. E) Connect inlet hose from tee assembly to operatory F) Connect each drain hose to drain hose connector and out to drain. G) Connect each drain hose to drain tee assembly. H) Connect main drain hose to tee and out to drain. AA2246-1 Wrench Supplied Drain 3

Exhaust Installation Pressure Sensor Use Elbow Only if Needed to Connect to User Supplied Exhaust Line Out to Vent Brass Tee Reducer Barbed Fitting Exhaust Hose Note Connections must be hand tight. May use mild soap for hose connections. Do NOT use glue on hose connections. Use glue ONLY on PVC connections. Parallel Float Fans Parallel Verify all local codes before installing inlet and drain hoses. Termination of hoses to be provided by installer. AA2254-1 Wrench is Provided Exhaust Connections.. A) Remove back covers, set to side, do not unplug fan cords. B) Plug in pressure sensor, float, and parallel (twins only). C) Install a reducer and barbed fitting into each end of brass tee. D) Connect two black-rubber exhaust hoses from base unit to brass tee assembly. E) Assemble exhaust drain assembly. Connect assembly to exhaust hose and to user supplied exhaust line to vent. F) Replace back covers. Note: Do not cut or shorten hose, High Temp. Note When working on twin units (replacements or adjustments), unplug parallel harness. 4

Electrical Installation Electrical Connections... A) Connect remote panel wires to low voltage control wires if applicable. B) Hard wire power supply conduit (back of base unit) to user supplied electrical boxes). Note: Refer to Control Panel Cross Wiring chart to connect Low Voltage wires. Pump must have line voltage present and be turned on & off with the low voltage circuit in order for the timer to work properly. DO NOT modify the length of the cables used on the seperator tank floats or the pressure sensor. Control Panel Cross Wiring Low Voltage Control Wires Brand Wire A B (Light) C Midmark - Apollo Blue White Red Air Techniques Yellow Brown Orange Den-Tal-Ez Black Brown Yellow Matrx Red Blue White 230 Volt Source, Single Phase, 60 Hz Recommended - 30 Amp Fuse Disconnect Box (Electrician Supplied) Green/Yellow = Ground One Black & One Red (Hot Wires)Connect to 230 Volt Electrical Supply All vacuum systems are to be installed according to local electrical codes. Never operate the equipment without complete and proper grounding. Refer to specification sheet for electrical ratings in this manual. 5 AA2248

Installation for ALL Models - Check and Test WARNING The On/Off switch controls only the secondary circuit power. The main power source must be turned off to remove all power in the control box. Too high vacuum level can cause injury and or operatory equipment failure. Do Not introduce foaming cleansers into vacuum system Max To Equipment Room Add From Operatory To Test... A) Check gear lube level on site glass. Add if below 1/3 full. Only use Midmark lube, PN 064-0028-01. B) Start vacuum. C) Use soapy water to check for leaks on external plumbing parts. D) Check the vacuum gauge. vacuum level range is 6 Hg to 18 Hg. E) Vacuum 1-2 gallons of fresh water into system through operatory lines. Run vacuum for 15 min. F) Turn vacuum off and ensure that water drains from separator without leaks. Note: Vacuum will not run without front cover. On/Off Switch Note Midmark recommends operation at factory preset of 12 Hg. If reading is low check for leaks or open operatory lines. 6

Vacuum Adjustment note When working on Twin units, unplug parallel harness. Adjust Vacuum Level (Only if needed)... note: Adjustment can only be made if unit is running and not in sleep mode. If unit is in sleep mode, turn unit off and back on before making adjustment. Unit will enter back into sleep mode in 60 seconds. Adjust vacuum level ( Hg) by... A) Press the ESC button until V xx shows on the screen. B) Press Enter to enter the vacuum setting. C) Press the right arrow to highlight the number you would like to change (fl ashing number is selected). D) Use up and down arrows to change the fl ashing number. E) Press Enter to confi rm the vacuum setting. F) To get back to displaying the pressure value, press the ESC button until the V xx shows on the screen. G) Press the up or down arrows until you see Mon on the display. Press enter. H) Press up or down to select U8-02, press enter. Pressure value should appear on the display. Vxx xx is a Variable Reading Mon Reading U8-02 Reading AA2326 AA2327 AA2328 note Vacuum level range is 6 Hg - 18 Hg. Midmark recommends operation at factory preset of 12 Hg. If reading is low check for leaks or open operatory lines prior to adjustment. 7 Installation is Complete

PowerVac G Specifications Classifications: Class 1, Type B Applied Part Model Max Users Base Unit HxWxD Separator HxWxD Actual Weight (LBS.) Total HP Voltage Amps Hertz Recommended Breaker Size (Amps) Inlet Connection Size (In.) Fuses Drain Connection Size (In.) G3 3-5 25 x 22 x 20 3 230 20 60 30 1/8 A, 250V G5 5-7 25 x 22 x 20 3 230 20 60 30 1/8 A, 250V G7 7-10 25 x 22 x 20 3 230 20 60 30 1/8 A, 250V G6 6 25 x 22 x 20 6 230 40 60 2 x 30 2 1/8 A, 250V G10 10 25 x 22 x 20 6 230 40 60 2 x 30 2 1/8 A, 250V G14 14 25 x 22 x 20 6 230 40 60 2 x 30 2 1/8 A, 250V Midmark Corporation 60 Vista Drive Versailles, OH 45380 USA 1-800-643-6275 1-937-526-3662 8