EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

Similar documents

Notes: 1 Square = 1 Foot

saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet

saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN

HDS-1000W Hot Dog Steamer

MODEL (Single Door) MODEL (2 Door pass through)

Incutrol/2 Regulator

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

MaxLite LED High Bay Fixtures

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

Mold Alert... Operation Manual P0270

IMPORTANT SAFETY INFORMATION:

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

Air Pump Up to 800 gallons

ELECTRIC FIREPLACE OWNER S MANUAL

MIGHTY PRO 1/4 HP CHILLER

IMPORTANT SAFETY INFORMATION:

Pressurized Filter Up to 1250 gallons

FAN-FORCED UTILITY HEATER

IMPORTANT SAFETY INFORMATION:

OPERATING INSTRUCTIONS

PATRIOT INSTRUCTION MANUAL FMFW-1500W/C FULL SIZE COOKER/WARMER

IMPORTANT SAFETY INFORMATION:

User s Manual and Operating Instructions

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

User s Manual & Operating Instructions

Cleanshield HEPA 550 Owner's Manual

Spa Control System OWNER S MANUAL

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

13500 BTU RV Air Conditioner Installation and Operating Instructions

Desiccant / Pump Dehumidification System. Model Operating Manual

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

ST-120/2 ST-120/3 ST-240/4 Steam Table

Instruction Manual Refrigerated Counter Top Displays

RC-E25, RC-E30, RC-E50 Rice Cooker

DDAC-1 deluxe digital atmosphere controller

IMPORTANT SAFETY INFORMATION:

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

USER MANUAL SAVE THESE INSTRUCTIONS

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

INSTRUCTION MANUAL. Full Size Gas Convection Oven

USER MANUAL. REVOLVE F20 (Repeat Cycle and Light Combo Timer ) AutopilotControllers.com APE2200

6-SITE SUPER-FLOW SYSTEM Instruction Manual

Installation & Operation Manual Ice Cream Freezers

OPERATION & INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION:

Instruction Manual Hydraulic Crimping Tool

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

IMPORTANT SAFETY INFORMATION:

Portable Induction Ranges

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

MODEL: DFH-IQH-62-01, DFH-IQH-62-02, DFH-IQH-62-03, DFH-IQH-62-04, DFH-IQH-62-05,DFH-IQH-06

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

OmniDry 2.9 Amp Centrifugal Air Mover

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

COH-267. COH-2670W Half Size Convection Oven

PORTABLE AIR CONDITIONER OWNER S MANUAL

20 High velocity Air

OPERATING INSTRUCTIONS

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Horizontal Bottle Cooler Installation and Operation Manual

SAVE THESE INSTRUCTIONS

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

USER S OPERATING AND INSTRUCTION MANUAL

Installation and Operations Manual

Zeus Extreme Owner's Manual

HD-26, HD-36, HD-48 Heated Displays

Indoor Climate Controller

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

WARRANTY AND INSTRUCTIONS

Owner s Manual & Safety Instructions

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

VX SERIES Wireless Thermostat with Occupancy Sensor

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

BF33ST/DX BF39ST/DX BF45ST/DX

Family size Glasstop warming tray WITH TEMPERATURE CONTROL

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

OPERATING INSTRUCTIONS

The Da-Lite Difference.

Transcription:

EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part # 702603 www.titancontrols.net

120V High Amperage Digital Humidity Controller Warnings and Cautions Factory Settings Eos 120V High Amperage Digital Humidity Controller Overview Instructions for Operation Error Codes Controller Specifications Controller Diagrams Installation Options Installation Example Warranty Information Service & Repair Program Warnings & Cautions Read all instructions before operating controller. Do not put your controller in an area where it can get wet or sprayed. Mount your controller securely to the wall. When using bug bombs in area, cover controller and sensor completely to avoid corrosion. There are no serviceable parts in controller. Do not attempt to repair the unit. Breaking tamper proof seal will void your warranty. Do not put paper clips, tools, etc. into unit. Possible electrocution may occur. Plug controller into surge protector to avoid potential damage to the unit. Confirm that your power source is 120 Volts/20 Amps prior to plugging controller into outlet. Check that all equipment that will be activated by this controller is the proper voltage. Verify that the equipment you are controlling does not exceed a total of 20 amps. This controller is designed for inside use only. Use caution if operating controller in extremely humid environments (90% rh and above). Do not use controller for purposes other than the unit was designed to function. Use controller within defined environmental specifications. Ask your Dealer for tips and techniques regarding the use of this controller. Be conscientious when disposing of any products. 2

Humidity Day Settings: 50% rh Humidity Night Settings: 50% rh Humidity Dead-Band: 5% rh Factory Settings Eos 120V High Amperage Digital Humidity Controller Overview The Eos 120V High Amperage Digital Humidity Controller is used to control humidify or dehumidify device. You can set your desired day and night relative humidity by adjusting the knobs on the front of unit. The adjustment of dial ranges from 5% rh to 90% rh. After setting the knobs at the preferred setting, the controller will maintain that setting utilizing a 5% differential or dead-band. This Eos unit provides up to 20 amps of capacity on standard 20 amp 120 volt circuit. Humidity Mode Program Instructions for Operation Press both knobs for 3 seconds, turn to select. Press both knobs again to save the setting. Humidify Mode: Raises the rh% to a level above the desired set point. Dehumidify Mode: Lowers the rh% to a level below the desired set point. Day & Night Humidity Set Point Press each knob and turn to set the Day and Night humidity, press again to confirm the setting. Humidity Dead-Band (hysteresis): 5% rh For example, when using Dehumidify, if the set-point is 45% rh and the dead-band is 5%, the Humidity output will activate at or above 45% rh and will deactivate at 40% rh. For Humidify mode, if the set-point is 45% rh, the output will activate at or below 45% rh and deactivate at 50% rh Humidity Min/Max Recall Click both humidity (Day or Night) knobs to display the Humidity min/max rh record. This shows the lowest rh and highest rh levels for a 24 hour period. The screen will return to normal display after 5 seconds or by a pressing both knobs, and the record will be reset. Day and Night Mode Day Mode: Humidity device works when the photocell senses light. Night Mode: Humidity device works when the photocell senses darkness. 24 Hours: Humidity device works during both day and night. This option utilizes both the programmed DAY and NIGHT humidity settings. In 24 hours mode, the settings are locked and cannot be adjusted. The controller must be switched to DAY or NIGHT mode to change the humidity setting. 3

Error Codes Check the sensor connection and verify that it is clean and free of debris If the humidity sensor doesn t observe the set point being reached in a 2 hour time period, the screen will flash with error code. Press any knob to reset error rating (20 A) Please check if the appliance outlet has exceeded the controller s max amperage Max Amp: 20 amps @ 120V 60Hz Sensor Cord Length: 15 ft Controller Specifications Humidity Range: 5% -90% rh Humidity Accuracy: +/-3% rh Humidity Dead-Band (Hysteresis): 5% rh Weight: 2.1lbs Dimensions: 5.07 x 4.68 x 1.95 Indoor Use Only Operating Temperature: 50 F to 95 F Maximum Relative Humidity: 95% Controller Diagrams: Humidity Humidify Mode Deadband Humidify Set point TIME ON ON Humidify Device OFF OFF Humidity Dehumidify Mode Dehumidify Set point Deadband Dehumidify Device OFF ON OFF TIME 4

Option 1: Secure the unit to a wall Installation Options Option 2: Screw the controller to the grow tent tube with a U bolt Installation Example Remote Sensor 120V 20Amps 120 Volt Circuit 5

Warranty Information Titan Controls warrants the original purchase of this product against defects in material and workmanship under normal use for two (2) years from the date of purchase. During the warranty period, Titan Controls will, at our option, and without charge, repair or replace this product if the controller or any of its components fail or malfunction. All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) number prior to any service of the product. This warranty is expressly in lieu of all other warranties, expressed or implied, including the warranties of merchantability and fitness for use and of all other obligations or liabilities on the part of the seller. This warranty shall not apply to this product or any part thereof which had been damaged by accident, abuse, misuse, modification, negligence, alteration or misapplication. Controllers with serial numbers or date tags that have been removed, altered or obliterated; broken seals or that show evidence of tampering; mismatched board serial numbers or nonconforming parts, are excluded from coverage. Titan Controls makes no warranty whatsoever in respect to accessories or parts not supplied by Titan Controls. Monetary refunds of the warranty will not be given. The Buyer assumes all responsibility regarding the use & installation of this controller. All warranty service is provided through the factory or an authorized service representative. This warranty shall apply only to the United States, including Alaska, Hawaii and territories of the United States and Canada. Defective controllers need to be returned with the proof of purchase/receipt. For additional warranty information, contact a Titan Controls Technical Service Representative at 888-808-4826 or your Dealer. Our normal business hours are Monday Friday, 8 a.m. to 5 p.m. Pacific Standard Time. We are closed most major holidays. NOTE: Titan Controls is a manufacturer of environmental controls. All sales offerings to the public are done through a nationwide group of Dealers. No sales offerings will be made directly to the general public. Service and Repair Program For all service and repairs please contact one of our Technical Service Representatives for a Return Merchandise Authorization (RMA) number. All factory service & repairs will be completed within 48 hours of receipt of controller and after authorization by customer for repairs. Titan Controls will, at its discretion, repair or replace the controller. Factory calibration services are available for all Titan Controls. Returning Units: Please contact your retail store for returns. 6

WARRANTY SERVICE: Please read warranty information first If after reviewing the troubleshooting tips the unit will still not work, you should return it to the Dealer where you purchased it. They will be able to further evaluate the unit and test its various components and quite possibly will be able to identify and/or fix any problems. If the Dealer is unable to fix the unit, they will return it to us for factory repair. If there are no Dealers in your area, you may contact us directly for technical support. If we cannot help you resolve the problem over the phone, we will issue you a RMA # (return merchandise authorization) authorizing you to return the unit to us for factory reconditioning (if the unit is under warranty). Contact the number below for a RMA and shipping address. Complete the form below and include it with your unit. Also please write the RMA # on the outside of the box. Please package the unit in its original packaging. If it is damaged in shipment we cannot be responsible. Once we receive the unit back, we will repair it within 48 hours (business) and return it to you freight prepaid via UPS ground shipment. Include the following if returning directly to Titan Controls Proof of purchase This completed form RMA # on the outside of the box Return Merchandise Authorization Number (Required): Company Name: Contact Name: Address: Phone #: Email address: What is the nature of the problem? Shipping address will be given when the RMA # is issued: www.titancontrols.net For technical assistance call us at 1-888-80-Titan or 1-888-808-4826. Representative available Monday Friday, 8 a.m. 5 p.m. PST. 7

Notes: 1 Square = Foot / Feet VANCOUVER, WASHINGTON U.S.A. www.titancontrols.net Revision C 09/28/2017 Titan Controls 8