ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Similar documents
ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Insulation fault evaluator EDS460-DG

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

IT system floor-standing distribution

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Remote alarm indicator and test combination MK2430

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

ISOMETER IRDH265 IRDH365

BENDER A-ISOMETER IRDH265 IRDH365

LINETRAXX RCMS460-D/-L RCMS490-D/-L

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

ISOMETER IRDH375 IRDH375B

A-ISOMETER IRDH575. Operating Manual

TM800. Remote alarm indicator and operator panels

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Operating Manual RCM420

Operating Manual VMD420

Bender GmbH & Co. KG All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives.

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

VME420 Voltage and frequency monitor

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

CMD420 / CMD421 Series

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

VME421H Voltage and frequency monitor

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Process Alarm Module RTA 421

Line Isolation Monitor (LIM) LIM2000plus

RCMA423-DM1C Residual current monitor

Universal fault annunciator for panel mounting

Operating Manual MS220KA and MSR220KA

Parameterisable compact fault annunciator with permanent display

Operating Manual MS220DA

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

ISOMETER isopv1685rtu isopv1685p isopv1685pfr

OilSET-1000 (12 VDC)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PolyGard 2-channel Gas Controller MGC-03

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

SET Installation and Operating Instructions. Level switch for one sensor

T M. User Manual LIM2010. Line Isolation Monitor

Interface and EOL Modules 8

General Specifications

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Operating Manual TR600

PROTECT SRB 200EXi-1A

IR5002. Operating Manual. Insulation monitoring device for IT DC systems V ISO Quality System Certified

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SCHMIDT LED Measured Value Display MD Instructions for Use

AO Annunciator Module

SET-2000 Hi Level/Oil

02/11/2015

Analog Annunciator Unit SACO 16 A3. Product Guide

02/11/2015

REA 105 Arc Protection Module. Operator s Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

SET-2000 Oil/Sludge 12 VDC

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Product overview. Alarm indicator, operator and display panels

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Universal controller for panel mounting Models CS6S, CS6H, CS6L

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Vibracon LVL-A* Level limit switch for liquids, compact design

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

EARTH FAULT METER MD-08

I/A Series 716C 1/16 DIN Temperature Controller

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

ISIS SAFETY SYSTEM Installation guide

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Operating Instructions Edition 02/2007

C-Bus Four Channel General Input Unit Installation Instructions

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Transcription:

with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017

with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) Product description The device combination ISOMETER IRDH275BM-7 and the coupling device AGH675S-7 or the coupling devices is designed to monitor the insulation resistance of unearthed medium voltage systems (IT systems). It is suitable for universal use in 3AC, combined AC/DC and DC systems. AC systems may include extensive DC-supplied loads. The AMPPlus measurement method meets the particular requirements of modern power supplies which often include rectifiers, converters, thyristor-controlled DC drives and directly connected DC components. Taking the system leakage capacitances into account, the IRDH275BM-7 automatically adapts itself to the existing system conditions in order to optimise the measuring time. ISOMETER IRDH275BM-7 with AGH675S-7 and Device features Insulation monitoring for drives including medium voltage converters up to 15.5 kv Two separately adjustable response values 100 kω 10 MΩ AMP Plus measurement method (European patent: EP 0 654 673 B1) Automatic adaptation to the system leakage capacitance Info button to display device settings and the system leakage capacitance History memory with real-time clock to store alarm messages with date and time stamp BMS interface (Bender Measuring Device Interface) for communication with other Bender devices (RS-485 electrically isolated) Current output 0(4) 20mA (electrically isolated) analogously to the measured insulation value Self monitoring with automatic alarm Automatic self test, selectable for external kω indication Test and reset button external test and reset button Two separate alarm relays with two potential-free changeover contacts N/O or N/C operation, selectable Backlit two-line plain text display Remote setting of specific parameters via Internet (option; COM460IP with at least Option C required) Application AC, DC or AC/DC medium voltage systems AC/DC medium voltage systems with directly connected DC components, such as rectifiers, converters, and thyristor-controlled DC drives Function When the insulation resistance between the system conductors and earth falls below the set response value, the alarm relays switch and the alarm LEDs light up. Two separately adjustable alarm relays allow to distinguish between prewarning and alarm. The measured value is indicated on the LC display or an externally connectable measuring instrument. The fault message can be stored. The fault memory can be reset by pressing the reset button. By pressing the test button, the function of the device as well as the connections to earth can be tested. Pressing the Info button provides additional information, such as the existing system leakage capacitance or device settings. The function of the earth connections are monitored. When a fault occurs, the system fault relay switches and the alarm LED system fault lights up. The parameterisation of the device can be carried out via the LC display or the function buttons integrated in the front plate. In addition, the device features: History memory with real-time clock to store all alarm messages with date and time stamp. Electrically isolated RS-485 interface (BMS protocol) for communication with other Bender devices Current output 0(4) 20 ma (electrically isolated) Measurement method The IRDH275BM-7 series uses the patented AMP Plus measurement method. This measuring method allows concise monitoring of modern power supply systems, also in case of extensive, directly connected DC components and high system leakage capacitances. Standards The ISOMETER of the IRDH275BM-7 series complies with the requirements of the device standards: DIN EN 61557-8 (VDE 0413-8), EN 61557-8, IEC 61557-8, IEC 61326-2-4, DIN EN 60664-1 (VDE 0110-1), DIN EN 60664-3 (VDE 0110-3), ASTM F1669M-96 (2007), ASTM F1207M-96 (2007) Approvals IRDH275BM-7 and AGH675S-7 2 IRDH275BM-7_D00123_03_D_XXEN/01.2017

Operating elements ISOMETER IRDH275 1 2 3 4 5 6 7 8 1 - INFO button: to query standard information back (menu function), to confirm parameter change 2 - TEST button: to call up the self test. Arrow up button: parameter change, to move up in the menu 3 - Two-line display for standard and menu mode 4 - RESET button: to delete stored insulation fault alarms parameter change, to move down in the menu 5 - MENU button: to call up the menu system. Enter button: to confirm parameter change 6 - Alarm LED 1 lights: insulation fault, first warning level reached. 7 - Alarm LED 2 lights: insulation fault, second warning level reached. 8 - System fault LED lights: IRDH275 or earth terminal defective Ordering information Nominal system voltage Un Supply voltage US Cable length Type Art. No. AC, 3(N)AC/DC DC 19.2 72 V IRDH275BM-727 B 9106 5120 2000 mm AGH675S-7-2000 B 913 061 0 7.2 kv, 0 460 Hz 500 mm AGH675S-7-500 B 913 060 0 15.5 kv, 0 460 Hz 500 mm -500 B 913 058 Suitable system components Type designation Type Art. No. External kω measuring instruments 9620-1421 B 986 849 Dimension diagram XM112 Dimensions in mm Dimension diagram Dimensions in mm 220 200 170 10 320 280 83 AGH675S-7 30 ø M4 52 IRDH275BM-7_D00123_03_D_XXEN/01.2017 3

Wiring diagram mains connection/example AGH675S-7 DC 15,5 kv 14 14 14 2 2 15,5 kv AC/DC 15,5 kv AC/DC 1 1 6 6 U S US 2 3 4 2 3 4 5 5 7 8 9 10 11 12 13 7 8 9 10 11 12 13 1 - Supply voltage U S (see ordering information) via 6 A fuse 2,3 - Terminals L1, L2 are not connected! 4 - to the coupling device AGH675S-7 or the two coupling devices : Connect terminal AK to terminal(s) 5 of the coupling device AGH675S-7 (or the two coupling devices ), with standard low-voltage cable, maximum voltage at terminal 5: 200 V 5 - Separate connection of and KE to PE 6 - Separate connection of the terminals 3 and 4 of the AGH675S-7 or to PE 7 - External TEST button (NO contact) 8 - External RESET button (NC contact or wire jumper), when the terminals are open, the fault message will not be stored 9 - STANDBY by means of the function input F1, F2: When the contact is closed, insulation measurement does not take place. 10 - Current output, galvanically separated: 0 20 ma or 4 20 ma 11 - Serial interface RS-485 (termination 120 Ω resistor) 12 - Alarm relay 1; changeover contacts provided 13 - Alarm relay 2 (system fault relay); changeover contacts provided 14 - of the coupling device AGH675S-7 to the converter: connect the high voltage cable encapsulated on one end to the mid-point of the DC intermediate circuit. of the two coupling devices to the converter: connect the high voltage cable encapsulated on L+ and L-. 4 IRDH275BM-7_D00123_03_D_XXEN/01.2017

Technical data IRDH275BM-7 Insulation coordination acc. to IEC 60664-1 Rated voltage Rated impulse voltage/pollution degree Voltage ranges Nominal voltage range Un Supply voltage US (refer to nameplate for other values) Power consumption AC 800 V 8 kv/3 via AGH675S-7 DC 19.2 72 V 14 VA Response values Response value Ran1 (Alarm 1) 100 kω 10 MΩ Response value Ran2 (Alarm 2) 100 kω 10 MΩ Relative percentage error 100 500 kω ±100 kω Relative percentage error 500 kω 10 MΩ 0 % +20 % Response time tan 5 min Hysteresis 25 % Measuring circuit Measuring voltage Um Measuring current Im (at RF = 0 Ω) Internal DC resistance Ri Internal impedance Zi, at 50 Hz Permissible extraneous DC voltage Ufg Permissible system leakage capacitance Ce Factory setting 50 V 21 μa 2.4 MΩ 2.4 MΩ with AGH675S-7 5 μf 2 μf Displays Display, illuminated two-line display Characters (number of characters) 2 x 16 Display range, measuring value 50 kω 10 MΩ Relative percentage error 50 500 kω ±50 kω Relative percentage error 500 kω 10 MΩ ±10 % Outputs/inputs TEST/ RESET button internal/external Cable length TEST/RESET button external 10 m Current output for measuring instrument SKMP (scale centre point = 1.2 MΩ): Current output (load) 20 ma ( 500 Ω) Accuracy current output (100 kω 10 MΩ) ±10 %, ±100 kω Serial interface Interface/Protocol IRDH275B RS-485/BMS terminals A/B Cable length 1200 m Recommended cable (screened, screen on one side connected to PE) J-Y(St)Y 2x0.6 Terminating resistor 120 Ω (0.5 W) Device address, BMS bus 1 30 (factory setting = 3) Switching components Switching components 2 changeover contacts: K1 (Alarm 1), K2 (Alarm 2, system fault) Operating principle K1, K2 (Alarm 1, Alarm 2) N/O or N/C operation Factory setting (Alarm 1/Alarm 2) N/O operation Electrical endurance 12 000 switching operations Contact class IIB (IEC 60255-23) Rated contact voltage AC 250 V/DC 300 V Making capacity AC/DC 5 A Breaking capacity 2 A, AC 230 V, cos phi = 0.4 0,2 A, DC 220 V, L/R = 0.04 s Minimum contact current at DC 24 V 2 ma (50 mw) Environment/EMC EMC immunity acc. to EN 61326 EMC emission acc. to EN 61326 Shock resistance IEC 60068-2-27 (device in operation) 15 g/11 ms Bumping IEC 60068-2-29 (during transport) 40 g/6 ms Vibration resistance IEC 60068-2-6 (device in operation) 1 g/10 150 Hz Vibration resistance IEC 60068-2-6 (during transport) 2 g/10 150 Hz Ambient temperature (during operation) -10 +55 C Storage temperature range -40 +70 C Climatic class acc. to IEC 60721-3-3 3K5 screw terminals rigid, flexible 0.2 4 mm²/0.2 2.5 mm² flexible with connector sleeve, without/with plastic sleeve 0.25 2.5 mm² Conductor sizes (AWG) 24 12 Other Operating mode continuous operation Mounting as indicated on the display Protection class, internal components (DIN EN 60529) IP30 Protection class, terminals (DIN EN 60529) IP20 Type of enclosure X112, free from halogen DIN rail mounting IEC 60715 Flammability class UL94 V-0 Tightening torque 0.5 Nm Documentation number D00123 Weight approx. 510 g IRDH275BM-7_D00123_03_D_XXEN/01.2017 5

Technical Data AGH675S-7 Insulation coordination acc. to DIN EN 61800-5-1 AGH675S-7 Rated insulation voltage Rated insulation voltage Voltage test acc. to DIN EN 61800-5-1 Type test: AGH675S-7 Voltage impulse test (basic insulation) AC voltage test (basic insulation) Partial discharge test Voltage impulse test (basic insulation) AC voltage test (basic insulation) Partial discharge test Routine test: AC voltage test Voltage ranges AGH675S-7 Nominal system voltage U n Nominal frequency f n Internal DC resistance R i Nominal system voltage U n Nominal frequency f n Internal DC resistance R i Bender GmbH & Co. KG P.O. Box 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de AC 7.2 k V AC 15.5 k V 40 kv 20 kv 14 kv 111 kv 70 kv 29 kv 40 kv AC, 3(N)AC, DC 0 7.2 kv 0 460 Hz 2.39 MΩ AC, 3(N)AC, DC 0 15.5 kv 0 460 Hz 4.7 MΩ Environment Operating temperature (normal operation) - 10 + 60 C Operating temperature (continuous operation with asymetrical earth fault - 10 + 55 C Classification of climatic conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3K5 (no condensation, no formation of ice) Transport (IEC 60721-3-2) 2K3 Long-term storage (IEC 60721-3-1) 1K4 Classification of mechanical conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3M4 (3M7 Y shaft) Transport (IEC 60721-3-2) 2M2 Long-term storage (IEC 60721-3-1) 1M3 terminal 2 (medium voltage), flexible with ring terminal 3, 4, 5 rigid, flexible flexible with connector sleeve high-voltage cable (encapsulated on the device side) M4 screw-type terminals 0.2 4 mm²/0.2 2.5 mm² 0.25 2.5 mm² Other Operating mode continuous operation Mounting any position Protection class, internal components (DIN EN 60529) IP64 Protection class, terminals (DIN EN 60529) IP20 Type of enclosure resin-encapsulated block Screw mounting M5 Flammability class UL94 V-0 Documentation number D00095 Weight approx. 5100 g BENDER Group IRDH275BM-7_D00123_03_D_XXEN / 01.2017 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing.