AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Similar documents
Advanced Ultraviolet Burner Controller

AUR300C. Advanced Ultraviolet Burner Controller

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

BC-R10 Series. Burner Controllers

UV Flame Supervision System

General Specifications

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Digital Heater Element Burnout Detector K8AC-H

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

Eclipse 90 UV Scanner Model A Version 1

DIGITAL BURNER CONTROLLER DBC2000 SERIES

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Buzzer Unit. TAN-5000 Series. Operating Manual

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

24 VAC Intermittent Pilot Gas Ignition Control

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

MBCE-110/230UV Flame Sensor Module

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Oil Burner Controls LMO24... LMO44...

ISOLATOR SGI SGIW INSTRUCTION MANUAL

Distributed By: M&M Control Service, INC

Oil Burner Controls LMO24... LMO44...

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Instruction manual for DIN rail mounting type indicating controller DCL-33A

BGH Series Hot Surface Ignition Control

Model Number Structure

E3M-V. Mark Sensor. Applications

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Fireye FLAME SCANNERS

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

C Note! LGI16... Burner Controls. Building Technologies

Operator: Save these instructions for future use!

DIGITAL INDICATOR JIR-301-M

Instruction manual Temperature Controller KT7

7800 SERIES RM7888A Relay Module

Eclipse Self-Check UV Scanner

250mm dia straight pipe length SP4 SP3. Air volume

Installation Instructions

Model 3300 Technical Support and Installation Manual

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

EUROFLAT SERIES TYPES C... S... M...

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

TEMPERATURE CONTROLLER

Two-Channel Gas Controller

Furnace Gas Monitor SD Operating Manual (PT2-163)

Hot-air generator. Operation manual (Basis operation) TAKETSUNA MANUFACTORY CO., LTD. Please read this without fail before use.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SHIMADEN DIGITAL INDICATORS

JW SERIES. Three Phase Thyristor Regulator PSE-351

Public Safety DAS Annunciator Panel

24 VAC Direct Spark Gas Ignition

INSTRUCTION MANUAL Micro-computer based digital indicating controller

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Smart Transmitter/ Gas Detector Head

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Please send to the customer who is used this operation manual without fail. Operation manual Basis operation edition

Ultrasonic Reflective Sensor

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

EUROBOX SERIES TYPES CM...N SM...N MM...N

7800 SERIES RM7888A Relay Module

EUROBOX SERIES TYPES CM... SM... MM...

Universal fault annunciator for panel mounting

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Ultrasonic Proximity Sensor

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

Instruction manual Micro-computer based digital indicating controller

InBio X60 Series Access Control Panel User Manual

M2500 Engine Controller Installation Manual

Series Temperature Controller Instruction Sheet

FIREYE FLAME SCANNERS

AnyWireASLINK System Products Guide

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

C 46 K a d. Specifications EKMC K. Ver.1.1. Page: EKMC K. 1.Product Name. 2.Model Number. 3.Dimensions. Approved by.

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Part 3 Troubleshooting

Flame Safeguards LFE10. Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Rules for Intruder Alarm Systems

VM-704B & VM-704 Temperature Monitor Module Manual

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Transcription:

No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls the built-in flame relay while checking if any malfunction has occurred in the UV detector or the AUR300C by driving the shutter of the UV detector. If the detector or amplifi er circuit fails for any reason, the AUR300C is not automatically energized and secures the safety of the system. Advanced Ultraviolet Burner Controller AUR300C, AUR30C Features When any abnormality exists at the start of operation, the start-check relay is not energized, ensuring safety by not generating a signal to the main valve or flame output. Operation status can be confirmed by LED displays (power, shutter, start check and flame). Flame signal output (0 to Vdc) is provided as a standard function. This is useful for burner adjustment and flame status control. A special loader (Smart Loader Package) for configuring the AUR30C from a PC is available (for the AUR30 only). The operation of the K3 relay (ON when an event* occurs, when flame voltage high or low limit is exceeded, or when maintenance cycle is due; or synchronous operation with relays K1 or K) can be specified using the Smart Loader Package (with the AUR30 only). AUR300 AUR30 With the RS- communication function, monitored trend data (flame voltage, shutter cycle, K1 K3 relay operation), maintenance data, and playback data (event history) can be displayed on a PC using the Smart Loader Package (with the AUR30 only). * In the case of the AUR30C, false flame, false discharge, frame ground short circuit, flame voltage drop, etc., are called events. The various settings are preset. Precautions for equipment instrumentation When designing facilities that include combustion safety equipment, take the safety directives listed below into careful consideration. Safety Engineering Directives for Industrial Heating Furnace Combustion Equipment (Health, Labor and Welfare Ministry) General Safety Code for Industrial Combustion Furnaces (= JIS B 1) Safety Engineering Directives for Industrial Gas Combustion Equipment (The Japan Gas Association) Safety Guidelines for Gas Boiler Combustion Equipment (The Japan Gas Association) Important safety points 1. Directly connect the load to this device.. Structure the interlock so that power to the load is directly turned off. 3. Use the start check circuit during startup (do not short out the start contact input).. Do not make a manual operation circuit or other bypass circuit for any load.. Use redundant shutoff for both the main valve and pilot valve. Precautions for system design Use an external circuit for the purge function (this device does not have a purge function). 1

Specifications General specifications Item Model Flame failure response time (3 V fl ame voltage) Flame voltage output Flame voltage range (at rated voltage, room temp, and humidity) Recommended flame voltage Rated power supply voltage Allowable voltage range Power consumption Dielectric strength Insulation resistance Induced thunderbolt surge Service life Ambient temperature Storage temperature Ambient humidity Vibration resistance Mounting posture Color Mass AUD300, AUD00 Nominal 1. s (max. s), Nominal 3 s (max. s) (selectable by model number) DC 0~ V Flame establishment: 1. to.0 V dc Flame-out detection: 0.0 to 0. V dc Stable.0 V dc or more 0 V ac or 00 V ac at 0/0 Hz to 1 % of rated power supply voltage W max. (with AUD300C/00C) 100 V ac 0/0 Hz 1 min or 0 V ac 0/0 Hz 1 s Application points: Between ground and primary terminals 1 to units (except 9 to 1) 0 MΩ min. by a 00 V dc megger Measurement points: Between ground and primary terminals 1 to units (except 9 to 1) kv, 1./0μs (JEC-17: 7Ω min. surge impedance) The surge absorber listed hereunder must be connected between the power supply terminal (No.1 terminal) and the ground. Recommended surge absorber: Part No. 39019-001 7 years or 0,000 cycles (operation cycles of each relay) 0~+0 C 0~+70 C 90 % RH at 0 C max. (without condensation).9 m/s max., to Hz for hours each in X, Y and Z directions Wall mounting (vertical or horizontal mounting) White Approx. 1. kg Communication specifications (only AUR30C) Item Communication level RS- compliant Transmission line connection Multipoint (up to 1 slave stations for 1 master station) Communication method Half-duplex Synchronization method Start-stop Transmission control Polling-selecting method (CPL communications format) Maximum cable length 00m Transmission line 3-wire system Transmission speed error 0.1% Terminating resistor Built in. Do not attach an external resistor. Transmission speed 00, 00, 900, 1900bps Data length bits Stop bits 1 or Parity bit Even parity or no parity Model selection table Basic No. AUR300C AUR30C Function Flame response Power supply Additional processing 1 Advanced ultraviolet burner controller Nominal 1. s (max. s) 3 Nominal 3 s (max. s) 1 0 V ac 00 V ac Advanced ultraviolet burner controller with communication function 00 No additional processing D0 T0 DT Inspection certificate provided Tropicalization treatment applied Tropicalization treatment applied and inspection certification provided

AUR300C part names Mounting holes : locations Install the product with M screws. Indicators Details on indicators Name Color POWER Green Lit when power supply is ON SHUTTER Green Lit when shutter is closed START CHECK Green Synchronous with K1 relay (start check) FLAME Green Synchronous with K relay (flame detection) 1 1 SHUTTER (G) 1 1 UV SENSOR (F) 11 11 0-V 9 9 Terminals for connecting an AUD300C or AUD00C Advanced Ultraviolet Flame Detector : Connect an AUD300C or AUD00C. Use M screws. K3 K1 K 7 7 3 3 Input/output terminals : Connect the power and various output signals. Use M screws. 1 1 Chassis ground connection : This is also used as a mounting hole. The coating has been removed to provide a good connection. Terminal assignments Terminal No. Electrical rating 1 AUD300C/00C Shutter (white) DCV 10mA *1 AUD300C/00C Shutter (white) 1 AUD300C/00C G-terminal (yellow) 11 AUD300C/00C F-terminal (blue) Flame voltage output (-) DC0~V * 9 Flame voltage output (+) Combustion lamp output (K3) 3A 0V 7 Combustion lamp output (K3) (cosφ=1) *3 Flame output (K1, K) A 0V (cosφ=1) Common output contact K relay (N.C. flame relay ) A 0V(cosφ=1) 3 Start input Power supply (R) high-voltage side AC0/00V 1 Power supply (S) ground side 0/0Hz *1 : Shutter does not have polarity. * : Use a measuring instrument with an input impedance of 0 KΩ min. To connect this device, use IV lead wires of 0.7 mm no longer than m. *3 : Operation is the same as for the K relay. (However, since a start-checking function is not provided, do not use for combustion control, but only for combustion monitoring.) 3

AUR30C part names Mounting holes : locations Install the product with M screws. Details on indicators Name Color POWER Green Lit when power supply is ON SHUTTER Green Lit when shutter is closed Indicators and communication terminal START CHECK Green Red Synchronous with K1 relay (start check) Blinks when an event occurs. 1 SHUTTER (G) 1 UV SENSOR (F) 11 1 1 11 Terminals for connecting an AUD300C or AUD00C Advanced Ultraviolet Flame Detector : Connect an AUD300C or AUD00C. Use M screws. FLAME Green Orange Red Synchronous with K relay (flame detection) The color depends on the flame voltage. Green :. V min. Orange : 1. to. V Red : Less than 1. V Off when the K relay is off. 0-V 9 9 K3 K1 K 7 7 3 3 Input/output terminals : Connect the power and various output signals. Use M screws. 1 1 Chassis ground connection : This is also used as a mounting hole. The coating has been removed to provide a good connection. Terminal assignments Terminal No. Electrical rating 1 AUD300C/00C Shutter (white) DCV 10mA *1 AUD300C/00C Shutter (white) 1 AUD300C/00C G-terminal (yellow) 11 AUD300C/00C F-terminal (blue) Flame voltage output (-) DC0~V * 9 Flame voltage output (+) Combustion lamp output (K3) *3 3A 0V(cosφ=1) *1 : Shutter does not have polarity. * : Use a measuring instrument with an input impedance of 0 KΩ min. To connect this device, use IV lead wires of 0.7 mm no longer than m. *3 : For the K3 relay, various outputs upon the occurrence of an abnormal state can be specified using the loader. With the default settings, the K3 relay turns on when an event occurs (specifically, when K turns off because of false discharge). 7 Combustion lamp output (K3) *3 Flame output (K1, K) A 0V(cosφ=1) Common output contact K relay (N.C. flame relay) A 0V(cosφ=1) 3 Start input Power supply (R) high-voltage side AC0/00V 1 Power supply (S) ground side 0/0Hz

Switch layout and function The AUR30C has a station address setting switch for communications, and also reset switches. These switches are located behind the protective plate of the AUR30C display. To set a station address or to reset events or values, pull the upper part of the plate toward you to remove it from the peg, and slide the plate upward. Switch layout S: Reset selection switch This DIP switch is used to select what to reset. S3: Reset switch This switch is used in combination with the S reset selection switches to clear the current maintenance cycle settings (operation time, combustion time, or combustion count basis for cycles) and to reset events. S1: Rotary switch for setting a station address A station address for RS- communication can be selected from 0 to F (1 addresses). Loader jack RS- communication connector Events or current values are reset by pressing the S3 switch. What is reset depends on on/off state of the S DIP switches. S 1 3 Events What is reset by pressing the S3 switch The current value of the item specified in maintenance cycle setting 1 The current value of the item specified in maintenance cycle setting The current value of the item specified in maintenance cycle setting 3 The current value of the item specified in maintenance cycle setting : ON : OFF Multiple S switches can be ON at the same time. For example, if the S3 reset switch is pressed with S-1 and S-3 set to ON, the current value of the items specified for maintenance cycles 1 and 3 will be cleared. All S switches are set to OFF at the factory.

Wiring Monitoring of burner flame Manual ignition (intermittent pilot) AUR300C, AUR30C AUR300C, AUR30C Advanced UV detector AUD300C/00C Measuring instrument DC0~V 1 1(G) 11(F) 9 Shutter driving circuit Flame amplifying circuit Flame voltage output circuit K3-1 SHUTTER LED K driving circuit K Microprocessor RS- communication LOADER SG DB DA * FLAME LED START CHECK LED Advanced UV detector AUD300C/00C Measuring instrument DC0~V 1 1(G) 11(F) 9 Shutter driving circuit Flame amplifying circuit Flame voltage output circuit K3-1 SHUTTER LED K driving circuit K Microprocessor RS- communication LOADER SG DB DA * FLAME LED START CHECK LED Combustion lamp output (K3) Combustion lamp output (K3) Flame output Common output contact 7 K1-3 K- Main valve Start switch SW 7 K1-3 K- High-voltage side (H) Power supply (G) Ligh-voltage side KNC Start contact 3 (R) 1(S) Start check circuit K1- K1 K-1 K1-1 POWER LED Power circuit High-voltage side (H) Power supply (G) Ligh-voltage side Ignition transformer Pilot valve Limit Stop switch Start check circuit K1- K1 3 (R) 1(S) K-1 K1-1 POWER LED Power circuit * : Only AUR30C Handling Precautions If the power supply circuit has a high potential side (H) and low potential side (G), connect the high potential side (H) to terminal (R) and the low potential side (G) to terminal 1 (S). If necessary, connect a device for overload protection to the power supply.

Dimensions AUR300 AUR30 (Unit : mm) 9.1 0 37 0 37 -R -R Free terminal screw M SHUTTER 1 1 SHUTTER 1 1 (G) 1 UV SENSOR (F) 11 1 11 3 9 1 (G) 1 UV SENSOR (F) 11 1 11 3 9 1 0-V + 9 9 0-V + 9 9 K3 K3 7 7 7 7 K1 K1 K K 3 3 3 3 1 1 1 1 1. 1. 7. 1. 7. 1. Chassis ground (commonly used as mounting screw) 7

Cautions (1) Do not install the flame relay in the following locations: Near the following chemicals or where their vapors are present: ammonia, sulfur, chlorine, ethylene compounds, acid, or any other corrosive gases. Locations subject to water spray Locations subject to continuous vibration () Before wiring, be sure to turn the power off. Touching terminals by mistake while the power is on may damage the device or result malfunction, or electrical shock. (3) After completing wiring, be sure to check all wiring connections. Incorrect wiring may damage the device or result in malfunction. In particular, as the flame detector (11(F)-1(G) terminals) has polarity, a reversed connection of F and G will result in the malfunction of the detector tube unit. () Use a dedicated packing case when transporting or storing this detector. () Do not bundle the power leads together with the flame detector signal lead wires, nor place them in the same conduit. Use independent cables. () Do not short-circuit the start input (terminals and 3) to operate the device by turning the power supply on or off. This interferes with the device s start-checking function. (7) This device must be grounded with a resistance less than 0Ω according to the technical standards for electrical facilities. Be sure to ground the device. () Make sure that the ignition transformer high-voltage cables are properly connected in order to prevent faulty contacts. If there is a poor contact, radio frequency waves may be generated, resulting in errors from radio interference. Install the ignition transformer directly onto a metal part electrically connected to the burner. (9) Protection against induced lightning surge is not provided in this device. When adding surge protection, connect the protection device between terminal No.1 and the ground. Recommended surge absorber: Part No. 39019-001. () Turning the power supply on and off quickly may result in malfunction. Wait an interval of approx. 3 s before turning the device on or off again. (11) Electricity may remain in No.11 (F) terminal even after the power supply is turned off. Touching the terminal within 1 min after the power has been turned off might result in electric shock. Do not touch the No.11 (F) terminal soon after the power has been turned off. Please read Terms and Conditions from the following URL before ordering and use. http://www.azbil.com/products/factory/order.html Specifications are subject to change without notice. 1-1- Kawana, Fujisawa Kanagawa 1- Japan http://www.azbil.com/ () 1st edition: Jun. 00 7th edition: Nov. 017 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.