Mr. GoodTower Service Center

Similar documents
MAINTENANCE INSTRUCTIONS

Bulletin 241B. Mark owned by the Cooling Technology Institute

Efficient, Long Lasting Evaporative Condensers

Since its founding in 1976, EVAPCO,

How about Savings in Time, Money, Energy and Longer Life?

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

Closed Circuit Coolers Technology for the Future, Available Today

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

Bulletin 241-E Metric C E R T I F I E D E N I S O Mr. GoodTower

Mr. GoodTower THERMAL PERFORMANCE 156 TO 1348 NOMINAL TONS. Mark Owned by the Cooling Technology Institute.

Bulletin 220-E Metric

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

C E R T I F I E D E N I S O

215 till kw nominal capacity

SECTION COOLING TOWERS

Evaporative Cooling products

Operation and Maintenance Instructions

BECAUSE TEMPERATURE MATTERS: MAINTAINING COOLING TOWERS

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

ENERGY SAVING, EASY TO INSTALL AND MAINTAIN FORCED DRAFT, AXIAL FAN CONDENSERS

Available in Capacities from 208 to 2,050 Ammonia Tons!

AT, MT & ES Series Super Low Sound Fan

Un-Used Series CXV Evaporative Condenser

Bulletin 242-E Metric C E R T I F I E D E N I S O Mark owned by the Cooling Technology Institute

Improving Condenser Safety In Cold Chain Facilities

Series V VCA Evaporative Condenser

SECTION COOLING TOWERS

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Reliable products with long-term, low cost of ownership

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Evapco Europe Company Presentation

RCF Closed Circuit Cooling Tower RCC Evaporative Condenser OPERATION & MAINTENANCE MANUAL

Compass Series Open Cooling Towers

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

XLP2 Evaporative Condensers

QuadraFlow Cooling Tower

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Baltimore Aircoil Company VX equipment has. Operating and Maintenance Instructions

Forced Draft, Axial Fan Models Available in Capacities from 124 to 1,408 Ammonia Tons!

What is a Closed circuit Cooling Tower (CCT)?

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

INVITATION TO BID FAILURE TO SIGN WILL DISQUALIFY BID Bid No.: #GK-MECH-YARD ADDENDUM NO. 1

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

FXV - CXV. Operating and Maintenance Instructions. Series 1500 Evaporative Fluid Coolers and Evaporative Condensers

PCT Cooling Towers OPERATION & MAINTENANCE MANUAL

Baltimore Aircoil Company Series VL equipment

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Baltimore Aircoil Company VX equipment

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Bulletin 313B. Mark owned by the Cooling Technology Institute

Series 1500 Cooling Tower Specification

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

Operation & Maintenance of Cooling Tower

What is Cooling S.Sen

Compass Series Cooling Towers OPERATION & MAINTENANCE MANUAL

STAINLESS STEEL EVAPORATIVE CONDENSER

Operation and Maintenance Instructions

INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE

Evaporative Condensers

/ Aquatower Fiberglass Cooling Tower /

Operation and Maintenance Instructions

Closed Circuit Cooling Towers

INFO. Stainless Steel Evaporative Cooler. The New Choice In Evaporative Cooling

COOLING TOWERS. AT UT USS Advanced Technology (AT) Series

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

Aquatower User Manual

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Cooling Tower Designs

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

Product Introduction...D9. Benefits...D11. Construction Details...D13. Custom Features & Options...D15. Accessories...D18. Engineering Data...

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Series 1500 Cooling Towers OPERATION & MAINTENANCE MANUAL

Bulletin 181-E Metric

COOLING TOWERS SERIES 3000 COOLING TOWERS CONDENSERS EVAPORATIVE CLOSED CIRCUIT COOLING THERMAL STORAGE

Aquatower STEEL COOLING TOWER. engineering data and specifications

Evaporative Condensers

12 Impeller Replacement

Closed Circuit Cooling Towers

Modular Supply Make-Up Air Unit

FRIGID COIL COPPER TUBE EVAPORATIVE CONDENSERS YEC Series

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Plenum Fans. Model HPA. Direct Drive

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

User Manual. Manual

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Dehumidification: Energy Efficiency Comparisons

EcoCooler Legionella Risk Assessment Information Pack

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

TOPAZ ADIABATIC COOLER

Transcription:

GTSC-E 0615 Mr. GoodTower Service Center Specialists in Replacement Parts and Maintenance of Evaporative Cooling Equipment

Call now for a free inspection on your Evaporative Cooling equipment to: Extend the life of your unit! Improve thermal performance! Identify potential problems! Reduce maintenance costs! The Evapco Group is committed to supporting their customers even in the difficult area of maintenance. The Evapco Mr. GoodTower Service Centers are your best answer for all your maintenance or service requirements. The Evapco Mr. GoodTower Service Centers offer high quality and professional service. The Evapco Mr. GoodTower Service Centers distribute official spare parts and components, approved and guaranteed by Evapco. The technicians of the Evapco Mr. GoodTower Service Centers have been trained at our manufacturing plants and they are therefore able to perform the maintenance operations according to the Evapco guidelines.

Professional service that ensures the full efficiency of the equipment and the proper performance over time. EXTEND THE LIFE OF YOUR UNIT Remove corrosion and install the exclusive EvapLiner protective membrane coating to all interior sheet metal surfaces. Replace old, corroded, worn panels. Reseal all sheet metal seams with new caulking to stop leaks. IMPROVE THERMAL PERFORMANCE Install new and more efficient wet deck and replace coil bundles for better thermal performance. Install new water distribution systems and recirculating pumps to provide better coverage over the wet deck or coils. Install new fan motors, sheaves, and fans to provide more airflow. Identify potential problems Replace old and worn shafts, bearings and wheels prior to failure. Emergency replacements can result in expensive repairs and unscheduled equipment down time. Install new winterization equipment such as sump heaters and pipe insulation. Replace noisy axial fan sections with new sections equipped with low sound fans or install silencers in the basin to reduce the noise of the water roar. Replace the drift eliminators to minimize the microbiological risk due to the Legionella pneumophila bacterium. REDUCE MAINTENANCE COSTS Install motor davits, ladders and platforms to reduce labor hours by providing easier access to high maintenance areas of the evaporative cooling unit. Install electric water level controls to eliminate the expenses associated with leaking mechanical make-up valves.

Maintenance Contracts Evapco evaporative cooling equipment is constructed with high quality materials and designed to ensure proper operation over time through a proper maintenance program. The units are oftentimes installed in a remote or distant location and recommended periodic inspections are often neglected. Why not delegate this important work to qualified personnel capable of ensuring the trouble-free operation of the equipment over time? The EVAPCO Mr. GoodTower Service Center are able to define a regular maintenance program and ensure its compliance. Maintenance programs will be established, by mutual agreement with the customer, in accordance with the criticality of the installation and the operating conditions. Proper equipment maintenance ensures trouble-free operation of the entire plant. Take care of your equipment! Rely on qualified technicians!

Maintenance Checklist 1. Clean pan strainer monthly or as needed 2. Clean and flush pan** quarterly or as needed PROCEDURE JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 3. Check bleed-off valve to make sure it is operative monthly 4. Check the pump and the pump motor - according to the manufacturer s instructions (Only for coil products) 5. Check operating level in pan and adjust float valve if necessary monthly 6. Check water distribution system and spray pattern monthly 7. Check drift eliminators quarterly 8. Check the fan blades for cracks, missing balancing weights, and vibrations - quarterly 9. Lubricate fan shaft bearing* - every 1000 hours of operation or every three months 10. Lubricate fan motor bearings see mfg s instructions. Typically for non-sealed bearings, every 2-3 years 11. Check belt tension and adjust - monthly 12. Sliding motor base Inspect and grease annually or as needed 13. Check fan screens, inlet louvers and fans. Remove any dirt or debris - monthly 14. Inspect and clean protective finish annually Galvanized: scrape and coat with ZRC Stainless: clean and polish with a stainless steel cleaner 15. Check water quality for biological contamination. Clean unit as needed and contact a water treatment company for recommended water treatment program** regularly * See maintenance manual for start-up instructions and lubrication recommendations ** Cooling Towers must be cleaned on a regular basis to prevent the growth of bacteria including Legionella Pneumophila

Quality guaranteed by EVAPCO EVAPAK deckfill The patented EVAPAK fill was developed in EVAPCO s heat transfer laboratory through thousands of hours of thermal performance testing. EVAPAK s unique crossfluted, counterflow fill pattern is designed to induce highly turbulent mixing of the air and water to provide superior heat transfer. The structure of the EVAPAK deck fill is stronger than other deck fill bundles available on the market. Each EVAPAK bundle is branded, i.e. single bundles are marked with the EVAPCO name to ensure identification of replacement fill. EVAPAK fill is constructed of inert polyvinyl chloride (PVC). It will not rot or decay and is formulated to withstand water temperatures of 55 C. Higher temperature fill is available upon request. In tests conducted according to ASTM-E84-81A, the EVAPAK flame spread rating was 5. EVAPCO will custom design and manufacture PVC fill for all cooling towers regardless of the original manufacturer. EVAPCO s patented EVAPAK fill is guaranteed to fit your existing cooling tower. If required, Mr. GoodTower Service Centers can offer the replacement thru their qualified technicians. EDE-001 Drift eliminators The eliminators shall be constructed of inert polyvinyl chloride (PVC) that has been specially treated to resist UV degradation. The eliminators incorporate three changes in air direction to assure removal of entrained moisture from the discharge airstream. The maximum drift rate does not exceed 0.001% of the recirculated water rate. EVAPCO will custom design and manufacture PVC drift eliminators for all axial or centrifugal units regardless of the original manufacturer. EVAPCO PVC eliminators are guaranteed to fit your evaporative cooling equipment. EVAPCO drift eliminators are available without frame, with galvanized frame or with stainless steel frame depending on the existing unit structure. WST Air Inlet Louvers EVAPCO S WST Inlet Louvers keep water in and sunlight out of the basins of induced draft products. The unique non-planar design is made from lightweight PVC sections which easily fit together enabling easy basin access. Developed with computational fluid dynamics (CFD) software, the louver s air channels are optimized to maintain fluid dynamic and thermodynamic efficiency and block all line-of-sight paths into the basin eliminating splash-out, even when the fans are off. Additionally, algae growth is minimized by blocking all sunlight. The combination of easy basin access, no splash-out and minimized algae growth saves the end user money on maintenance hours, water consumption and water treatment costs

EVAPCO Spare Parts EVAPAK Deck Fill Components for axial and centrifugal fan groups Float valve & ball assemblies EDE 001 Drift Eliminators Pan strainers Unit sound attenuation WST Air Inlet Louvers Motors & Pumps Complete section replacement Threaded Nozzles Evapjet Nozzles ZM Nozzles Ladder & Platform Installation Exclusive EvapLiner treatment... and any other component.

Evapco Mr. GoodTower Service Center REPLACEMENT REPAIR RESTORATION EQUIPMENT UPGRADES SERVICE CONTRACTS Contact the local Mr. GoodTower Service Center: www.mrgoodtower.eu www.evapco.eu EVAPCO Europe Srl Via Ciro Menotti 10 20017 Passirana di Rho (MI), Italy Tel. +39 02 9399041 Fax +39 02 93500840 email: mrgoodtower@evapco.it EVAPCO Europe bvba Industrieterrein Oost 4010 3700 Tongeren, Belgium Phone: +32 12 395029 Fax: +32 12 238527 email: mrgoodtower@evapco.be.