Ventilation Trainer B500

Similar documents
Vapour Jet Refrigerator / Heat Pump R853

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Mechanical Heat Pump R515

Refrigeration Cycle Demonstration Unit R634

Refrigeration Cycle Demonstration Unit R633

Air & Water Heat Pump R832

A660 Air Conditioning Laboratory Unit

Bench Top Cooling Tower H893

Heat Transfer Service Unit H112

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

INSTALLATION DO S AND DON TS

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Glass Canopy Wall-Mount Hood

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

TESTING, ADJUSTING AND BALANCING

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Ducted Propeller. Airflow Volume

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

LAB EQUIPMENT DETAILS

Performance Rating of Commercial and Industrial Humidifiers

SECTION DUCTWORK

Centrifugal Fan Teaching Trainer HVCB. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

Modular Supply Make-Up Air Unit

How to Take Basic Readings to Show Energy Efficiency

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Advance Release September 2009

Installation and Maintenance Manual IM 1102

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Duct Design and Installation

Residential HVAC System Design

OIL TREATMENT ARRAS MAXEI

DIVISION 15 MECHANICAL

PureLine D. Technical Specification

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION TESTING, ADJUSTING AND BALANCING

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

GIVE A FAN A CHANCE Installation Dos & Don ts

INSTALLATION INSTRUCTIONS

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

SKYPAK II, 3 Ton Series, gives you a

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

City of Duluth Festival Center 04/25

Instructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods

BFM Balanced flue commercial water heater

Product Line Introduction. Karl Zhang Technical support engineer

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

OIL TREATMENT ARRAS MAXEI

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

1.1 This section applies to air handling units for HVAC Systems.

SECTION DUCTWORK

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Frequently Asked Questions

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

SECTION AIR DUCT ACCESSORIES

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Are you Getting Your Fan Flows Right?

EHH SERIES DRAW THROUGH FAN COILS CFM

Indirect Gas-Fired Make-Up Air

HEATING & COOLING COIL PRODUCTS

Problems Air and Water Distribution Systems

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

PRODUCT CATALOG BLOWER COILS.

FCC Fan-Coil Units High-Performance, Vertical

250mm dia straight pipe length SP4 SP3. Air volume

Compensating Installation Instructions Manual

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

ORC93XA ORC94XBA. Wall Canopy Rangehoods

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Closed Circuit Cooling Towers

INSTALLATION INSTRUCTIONS

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

VERTICAL FAN COIL UNITS

E U R O V E N T CERTIFIED PERFORMANCE

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

DUCTING FOR HRV SYSTEMS The distribution of airflows

TopMaster Air Handling unit. Technical data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Thorough Examination and Test of Local Exhaust Ventilation Systems to Regulation 9 of the COSHH Regulations 2002 (as amended)

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Transcription:

Ventilation Trainer B500 Safe and Suitable For Unsupervised Student Operation. Responds Rapidly to Control Changes. Negligible Operating and Maintenance Costs. Two year Warranty. Page 1 of 5

Introduction The use of full air conditioning systems for controlling the environmental conditions within buildings is increasing rapidly. In order to ensure economical and efficient operation of such plant, the use of more complex controls, including computers, has become necessary. However, even the most complex and technologically advanced control system will be of little use if the air distribution system of the building has not been commissioned to the design specification. Air dampers and fan controls have to be adjusted in order to ensure that the correct amount of conditioned air is distributed to all areas within the building structure. Understanding the commissioning procedures is extremely difficult and unfortunately in the past most building services engineers have had their first experience when in employment actually carrying out the process on site. The Hilton Ventilation Trainer B500 has been designed to provide training establishments with a flexible, realistically scaled system that students can assemble in a variety of combinations and then commission to achieve a set of Design Conditions. The unit utilises the fabrication and assembly techniques used in commercial air handling equipment and this helps familiarise students with the types of components they will meet in industry. The unit is applicable for the teaching of students in: Building Services Refrigeration and Air Conditioning Mechanical Engineering Plant Engineering Marine Engineering Experimental Capabilities The standard package B500 enables the following training exercises to be undertaken: Examination of typical components, fabrication, installation and assembly techniques used in air handling systems. Investigation of pressure losses in bends, branches, changes of section and over straight lengths of duct, together with the variation in pressure drop with velocity. Determination of the K factor for the pressure loss of the above components in each particular configuration. Investigation of the fan pressure and volume flow characteristics at various supply voltages. Examination of standard types of panel and bag filters and their pressure drop against face velocity. Measurement of air flow rate using pitot-static traverse, orifice pressure differential and anemometer methods. Balancing of air flow distribution in a series or two branch parallel distribution system using either main damper or fan speed flow control. Addition of the B500B (see diagram) allows an additional parallel branch and two diffusers to be investigated. Addition of the B500C (see diagram) allows an additional tee branch and two diffusers to be investigated. Addition of the B500D Ductwork Leakage Test Set allows students to carry out commissioning leak testing on all of the above components Page 2 of 5

Description A glass reinforced plastic control console is mounted on top of the steel fan stand. The fan unit has a delivery of between 0.1 and 0.3 3/s dependent upon the ductwork resistance and supply voltage. The console contains a variable transformer for fan speed control, together with a voltmeter and ammeter for measurement of supply voltage and current. The unit has a combined switch and overload circuit breaker and a separate 30mA residual current circuit breaker for added safety. A square to round fan intake transition also accepts standard 600mm x 600mm filters. The rectangular to round fan discharge transition connects to the 200mm diameter ductwork using standard push fittings. All ductwork and connections are manufactured from heavy gauge galvanised steel and may be connected in the forms indicated in the diagrams. The ductwork is supported from standard air distribution isolation mounts hung on galvanised steel pedestals that are rigidly linked together. Components may be readily assembled into either of the two standard configurations and the additional optional branches added. Two types of air supply diffuser units are supplied and these, together with the manometer, pitot-static tube and hand held anemometer supplied, allow investigation of discharge velocity patterns. The optional B500D ductwork leakage tester is a complete test apparatus used by commissioning engineers for leak testing ductwork on site. The leak rates for unsealed or poorly assembled joints, as well as open inspection holes, may be investigated. This provides students with valuable experience of commissioning procedure which is becoming increasingly important with the introduction of more stringent fire regulations. B500 shown with Optional Extra B500B fitted Page 3 of 5

Page 4 of 5

Specification B500 Ventilation Trainer General A realistically scaled ventilation training unit capable of enabling students to study both basic airflow and fluid mechanics as well as the more complex process of commissioning and balancing a multi-ducted air distribution system. The unit consists of a foreword curved variable speed centrifugal fan and integral control console together with a rectangular air intake and filter holder. The fan has a supply pressure of up to 350Nm-2 and a flow rate of approximately 1400m3h-1 depending upon the blockage factor. The fan discharges directly into a 200mm dia. galvanised steel duct and this connects directly to the distribution ductwork. Sufficient components are supplied with the unit to enable parallel branch and line balancing experiments to be undertaken. A minimum of 6 air supply points are provided that may be balanced on the assembled unit to supply a range of airflows. A portable manometer, pitot static tube and hand held anemometer allow a large range of experiments to be undertaken. B500B (Optional Extra) The optional extra duct configuration B500B allows the addition of a third parallel branch and two air supply units. B500C (Optional Extra) The optional extra duct configuration B500C allows the addition of a 6m branch and two air supply units. B500D (Optional Extra) Optional Extra B500D Ductwork leakage tester allows investigation of the structural integrity of the ductwork Dimensions Height: 2000mm Depth: 3000-9000mm (approx.) (larger dimension only if B500C included) Length: 1000-11000mm (approx.) (depending upon configuration) Weight: 320kg. (nominal) Services Required Electrical: A: 1.5kW Single Phase, 220-240 Volts, 50Hz (With earth/ground) or B: 1.5kW Single Phase, 110-120 Volts, 60Hz Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in either English, Spanish or French. Accessories and spares for 2 years normal operation. List available on request. Ordering Information Order as: B500 Ventilation Trainer Electrical Specification Electrical: A: 1.5kW Single Phase, 220-240 Volts, 50Hz B: 1.5kW Single Phase, 110-120 Volts, 60Hz Language Either: English, Spanish, French. Shipping Specifications Nett Weight: Gross Weight: Packing Case Size: Packing Case Volume: 320 kg 627 kg (approx) 4.089 x 0.838 x 1.43m (approx.) 4.9m 3 (approx.) Also Available On Request Further detailed specification. Additional copies of instruction manual. Recommended list of spares for 5 years operation. P.A.HILTON Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: National (01794) 388129 International +44 1794 388129 E-mail: Website: sales@p-a-hilton.co.uk www.p-a-hilton.co.uk Page 5 of 5