SECTION C2: OUTFALL CONSTRUCTION AND DESIGN

Similar documents
C.1 Operational Information Requirements

Environmental Protection

St Marys Bay and Masefield Beach Improvement Project Overview

JIWET technical report. 8. Rotary Screen


Severn River Sub-Watershed: BMP 09-Retrofit

STORMWATER - GENERAL NOTES

Sewer & Storm Drain Systems

PS12 CITY OF TERRE HAUTE VIGO COUNTY, INDIANA DRAWING NO. EXISTING AND NEW STRUCTURE DATA TABLE JW, CM. No. DATE DESCRIPTION REVISED BY JLH ACS

MWRA COMPLETED CSO PROJECTS Updated November 2, 2011

Aberdeen Harbour Expansion Project. Construction Environmental Management Document

STORM DRAINAGE CONSTRUCTION NOTES LENGTH RUN * See Note 2., Above or greater 500

A. Regional Detention Requirements

EMD - Rotary Drum Screens

LIMITED ENVIRONMENTAL REVIEW

Appendix K. Stormwater Management Plan

Impact of Storm Drains on Urbanized Alluvial Fan Flooding in Ventura County, California

VERSA Rotary Drum Screens

Checklists. Project Name: Location: File Number: Date of Submittal: Reviewer: Date: Applicant: Contact Name: Phone Number:

3.2 EXISTING LAND USE. Landscape & Urban Design Framework

Open Charter Magnet School Water Retention System OPERATION, MAINTENANCE & INSPECTION SUPPLEMENT October 20, 2007 Richard Haimann, P.E.

Joseph Florio, Commissioner of Pub. Works Tel

DRAFT POOLBEG PLANNING SCHEME

There is an ongoing regulatory concern that

NYC Green Infrastructure Program

Public Information Centre # 2 Coronation Park Drainage Improvements Town of Oakville Municipal Class Environmental Assessment

FOR THE PERIOD JANUARY 1, TO DECEMBER 31, GENERAL INFORMATION

CHAPTER 9 STORM DRAINAGE. Minimum Requirements for New Development and Redevelopment

STORMWATER MANAGEMENT PLAN: ERAND GARDENS X70

A LARGE MULTI-FUNCTIONAL BIORETENTION DEVICE

Village of Sloan Smoke Testing September 2017

Content. 1 Basics. 2 Detailed Information on different types of Vacuum technologies. Vacuum sanitary installations. Vacuum sewer systems

New York City, 17 th c.

Regional Stormwater Management Program

1 LIST OF POTENTIAL PCB SOURCES

Brigitte A. Berger, Director of Engineering

DEPARTMENT OF PUBLIC WORKS & UTILITIES

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

City of Dade City AMEC Project No Dade City Stormwater Master Plan September 2012 Page 32

CITY HALL HOBOKEN. NEW JERSEY

30% Design Technical Report

Design & Access Statement

Tentatively Selected Plan within Harlem River, East River and Western Long Island Sound Planning Region. First Level Costs. Federal Non-Federal Total

Polluted Surface Water Outfalls -what s the problem?

STAFFORD TRACT NORTH OF US90A 1.0 INTRODUCTION 1.1 OBJECTIVE

EXECUTIVE SUMMARY Greater Milwaukee Watersheds Stormwater Report. Background and Significance

Feet. Overland. Drainage Area Boundary. To Swale. Swale. To Catch Basin. Culvert Pipe. To Drain Outfall. NRCS Soil Area Boundary

Case 1:85-cv RGS Document 1769 Filed 06/15/12 Page 1 of 13. UNITED STATES DISTRICT COURT for the DISTRICT OF MASSACHUSETTS

RESILIENCY, ADAPTATION, & SUSTAINABILITY AT THE CITY OF ST. AUGUSTINE

Bilfinger Water Technologies GmbH. Coarse and Fine Screening NOGGERATH Rotary Drum Screen NSA & NSA-Plus

Figure 1 Cypress Street Study Area Location Map

To Compliance and Beyond. Valley Chrome Plating s Journey to Zero Discharge

TOPS K-8. Teacher Guide. CONTENTS Stormwater in the Schoolyard Lesson 3

6.5 Lakewood Gulch. Basin Snapshot

Rainwater - Management for the environment and nature protection

WATER DIVISION INSPECTION REPORT

Roediger Vacuum GmbH Kinzigheimer Weg Hanau, Germany Phone: Telefax:

Project Output Indicators for Federal Gas Tax Investments

October 7, City of Thornton 9500 Civic Center Drive Thornton, CO (303) RE: Maverik Thornton, CO - Drainage Report

13 Landscape and Visual

BUILT FOR THE PERFECT STORM

URBANIZED STREAM CORRIDOR: COMMUNITY APPROACH TO ADDRESS EROSION

Water Conservation Technologies, Larc 380 Semester Assignment

TECHNOLOGIES AND EQUIPMENT FOR WASTEWATER TREATMENT RAKE BAR SCREEN

Best Environmental Management Practices

Modernizing your Sewer Flow Monitoring Technology

Let s Go to the Beach Evaluation and Modeling of a Coastal Community s Storm Drain System and Outfalls. Jeff Riling GHD November 2016

URBAN FLOOD MANAGEMENT IN CYPRUS CASE STUDY IN NICOSIA URBAN AREA

Installation, Operation, and Maintenance Manual. ASP HDPE Package Sewage Treatment Plants

The use of low head weirs to. perennial streams with their floodplains:

88MLV Series Open Channel Modular UV Systems

Pollutant Removal Benefits

Ashbridges Bay Erosion and Sediment Control Project

Custodian: The Corporation of the District of Saanich, Underground Services Division

Stormwater Retrofitting: The Art of Opportunity. Presented by the Center for Watershed Protection

HUBER Grit Separation Systems

The Island s Largest Independent Estate Agency

Practical Solutions for Combined Sewer Overflow Control. Engineering Healthy Waterways

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

Torquay Town Centre Community Partnership and Town Centre Focus Group

Sewer Flooding Alleviation in the Counters Creek Catchment

Inspection Report: Cave City WWTP - Cypress Ln Lift Station, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

David Clark, P.E. RW Armstrong & Associates, Inc. June 20, 2012

2016 WORKSHOP LVR Field Trip

HOW TO MODEL IMP FACILITIES USING BAHM. By Douglas Beyerlein, P.E., Clear Creek Solutions, Inc. Introduction

MANUAL OF DESIGN, INSTALLATION, AND MAINTENANCE REQUIREMENTS FOR STORMWATER MANAGEMENT PLANS

Guidelines for the Sanitary Sewer Evaluation Survey (SSES) Report PLAN A

Hazen and Sawyer 545 Mainstream Drive, Suite 320 Nashville, TN

15.0 EFFECT ON THE ENVIRONMENT: Sunlight

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

Home owner s manual Pressure sewerage system

ENGINEERING SERVICES COMPANY PROFILE

STORM SEWER OUTFALLS AND CONNECTING OUTFALL CHANNELS. General Submission Requirements

Iona Island Wastewater Treatment Plant Project. Welcome to Community Workshop 1 January 9, 2019

XSW11, Plumstead Portal worksites, Interim Statement for NLBH. 1 Introduction Site Methodology and fieldwork objectives...4

4. TECHNOLOGY AND DESIGN CRITERIA

FEB 2016 COUNTY MAP NTS

Victor Shapilsky and Adison Ang

RainHarvesting Systems Brochure 2011

Transcription:

Tramore Sewerage Scheme WWDL Application SECTION C2: OUTFALL CONSTRUCTION AND DESIGN Table of Attachments Item Title Map/Photo No. 1 Stormwater Overflow Manholes Drg. No. 3 2 Plan and Longitudinal Section of Sea Outfall from Drg. No. 4 Tramore WWTP 3 Details of Diffuser at Primary Point and Drg. No. 5 Outfall Manhole OF 6 4 Details of Cove SWO Chamber Drg. No. 6 The primary discharge point from Tramore Wastewater Treatment Plant was constructed in 2005 in accordance with Drg. Nos. 4 and 5 of this attachment. SW1: Primary Point The final effluent from the Treatment Plant is discharged to an 800 mm PE100 SDR 17.6 polyethylene pipe, which outfalls to Tramore Bay at the location shown on Drawing No. 4 of this attachment. (Also refer to the drawings and photographs in Attachment No. B3). A multi-port diffuser has been constructed at the discharge point in accordance with Drg. No. 5 of this attachment. The invert level at the point of discharge is -16.17 mod (Malin Head). 800 mm diameter outfall pipe from Waste Water Treatment Works, with multi-port diffuser at discharge point (SW1) 259370E, 98984N (SW1) For inspection purposes only. MCW0498 69 Rev. A01

Tramore Sewerage Scheme WWDL Application The construction of the following overflows pre-dates the Urban Wastewater Treatment Directives, therefore the design of the chambers is not based on the following: dilution rates or capacity in relation to dry weather flow or a specified number of overflow events per year The National Urban Waste Water Study, Volume 2, Part C states that Irish national regulations dictate that both spill frequency and volume are restricted as regards the protection of bathing waters whilst screening to prevent the escape of visible debris also requires consideration. In recent years, 6 mm fine screens have been fitted to the existing chambers. These mechanically raked screens contain solids in the SWO chambers during period of overflow. SW2: Secondary Point There is an emergency overflow from the Promenade Pumphouse, which comes into operation when pump failure occurs and flow backs up in the system. The overflow chamber is located at Mh. 50, which is located upstream of the pumphouse. Overflow from this chamber is spilled to Mh. 60 in a 525 mm diameter overflow pipe. From Mh. 60 the flow is discharged to the beach via a 300 mm pipe running southwards from Mh. 60. Refer to the drawings and photographs in Attachment No. B4. Details of the overflow chamber, Mh. 50, are shown on Drg. No. 3 of this attachment. The invert level of the overflow pipe at the chamber is 0.83 mod (Malin Head). (Also refer to the drawings and photographs in Attachment No. B4). Overflow Weir in Mh. 50 (SWO1) Overflow discharged to beach via 300 mm diameter overflow pipe (SW2) 258990E, 101148N (SWO1) 258996E, 101067N (SW2) For inspection purposes only. SW3: Stormwater Overflow from Mh. 80 Mh. 80 is a stormwater overflow chamber situated towards the eastern end of the Promenade near the Lifeguard Station. Spill from this chamber is subjected to fine screening before being discharged to the 28 meters of 300 mm diameter overflow, which exits through the Promenade wall onto the beach. Details of the overflow chamber, Mh. 80, are shown on Drg. No. 3 of this attachment. The invert level at the point of discharge is 2.18 mod (Malin Head). (Also refer to the drawings and photographs in Attachment No. B5). Overflow Weir in Mh. 80 (SWO2) 300 mm diameter combined sewer overflow pipe (SW3) 258786E, 101130N (SWO2) 258772E, 101107N (SW3) MCW0498 70 Rev. A01

Tramore Sewerage Scheme WWDL Application SW4: Stormwater Overflow from Mh. 47 Mh. 47 is the largest of the Tramore SWOs in terms of spill volumes recorded. It is located on the Strand Road opposite the Arcade Amusement Centre. There is a 600mm overflow pipe from Mh. 47. This is 162 m in length with 2 no. manholes (45 and 46), and discharges to the beach through the Promenade wall adjacent to the slip at the end of Strand Street through a short length (14 m) of masonry culvert. Details of the overflow chamber, Mh. 47, are shown on Drg. No. 4 of this attachment. The invert level at the point of discharge is 3.76 mod (Malin Head). (Also refer to the drawings and photographs in Attachment No. B5). Overflow Weir in Mh. 47 (SWO3) Masonry culvert to beach outfall (SW4) 258330E, 101244N (SWO3) 258220E, 101099N (SW4) SW4: Stormwater Overflow from Mh. 14 There is an SWO chamber, Mh. 14, located on Strand Street at the side of O Shea s Hotel. There is a 600 mm overflow pipe from the chamber which discharges to Manhole 45 on the overflow from the Arcade SWO (Manhole 47), 14 m upstream of where the masonry culvert discharges to the beach through the Promenade wall. (Refer to the drawings and photographs in Attachment No. B5). Details of the overflow chamber, Mh. 14, are shown on Drg. No. 4 of this attachment. The invert level at the point of discharge is 3.76 mod (Malin Head). (Also refer to the drawings and photographs in Attachment No. B5). Overflow Weir in Mh. 14 (SWO4) Masonry culvert to beach outfall (SW4) 258211E, 101139N (SWO4) 258220E, 101099N (SW4) For inspection purposes only. SW5: Stormwater Overflow from Cove SWO Cove SWO chamber is located on The Cove, situated to the south west of Tramore Strand. It is immediately upstream on the adjacent Cove Pumping Station. Wastewater from this pumping station is pumped to Doneraile Walk, from where it gravitates to the Promenade Pumphouse. Overflow from Cove SWO occurs when the storage at the pumping station is insufficient and flow backs up to the SWO. A 300 mm diameter overflow from the SWO chamber carries the spill to a 450 mm diameter pipe which discharges to the sea on the eastern side of the harbour. Details of Cove SWO chamber are shown on Drg. No. 6 of this attachment. The invert level at the point of discharge is 4.47 mod (Malin Head). (Also refer to the drawings and photographs in Attachment No. B5). Overflow Weir at The Cove SWO Chamber (SWO5) 450 mm diameter combined sewer overflow pipe to beach outfall (SW5) 257560E, 100497N (SWO5) 257625E, 100507N (SW5) MCW0498 71 Rev. A01