Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Similar documents
User Manual AF-30-VT

1850 Series TRIPLE TREAT Operation Manual

What to expect from your water softener

Water Softener Installation Guide Effective for all Softeners from our Range

Owner s Manual / 5600 Econominder

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

NOT EVERYTHING IN LIFE IS COMPLICATED.

7000 Meter Initiated Valve

Installation, Commissioning, Programming & User Information For Water Softener Models: SF 10 Litre Timed & SF 12 Litre Metered

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

O P E R A T I N G M A N U A L

2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL

Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models

Installation and Operations Manual

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

MP-MBA-45T-1/60T-1 / 75T-1

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

AC40 & AC40BAutomatic Water Softener Operation and Recharging

Plumbline 1000 Series Timered Softeners Owners Manual Water Softener Models

Autotrol Performa FA Valve

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

Econoflo SXT Automatic Meter Initiated Water Softener

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

6700XTR Valve Downflow

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

NovoSoft 465 Series SIM Water Softener Operation Manual

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION

Water Softener. Operating Manual

ProFlo SXT Valve Downflow / Upflow

Installation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

FULLY AUTOMATIC WATER SOFTENER

High Flow 7000 SXT Series Water Softeners

CONTENTS. Page. Contents. Introduction, features and benefits. PART ONE Overview of the water softening process 4-5

Fully Automatic Water Softeners

High Flow 7000 SXT Water Softener

Owner's Manual. WS Series. Water Softener

Water Softener VSOFT 15. Fitting and operating instructions. Changes of technical details are reserved. VSOFT / BWT UK Limited F R E E H O M E

Metermatic Water Softener. Operation Manual

Fleck 2510 Softener Installation & Start Up Guide

WS1 Softener Installation & Start-Up Guide

RIVERSOFT Water Softener System

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

EVOLIO-560 Water Softener System

SHOWER SOFTENER-CEASA 1

Fleck 2510 SXT Catalox Installation & Start Up Guide

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

BWT WS Range Water Softener

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

Installation and Operation Manual

565 TLC Softener & Tannins Reduction System

Evolve Series. Water Softeners and Conditioners. For Models: EV1 EV2 EVR EVRC EVRS EVRCS. For Cabinet Models: EVC EVCS

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Autotrol Performa Ultra. Electronic Control System Operation and Maintenance Manual

IMPORTANT SAFETY INFORMATION READ ALL...

Installation & Service Manual

Autotrol Performa Valve

FLECK 5600 WATER SOFTENER INSTALLATION

Autotrol Performa Valve

The WateRx Plant. Features/Benefits. Applications (for municipal water usage) Great water throughout the home or office. Automatic weekly backwash

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,

5900S Softener Installation & Start-Up Guide

INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS

OptiSoft Softeners Simple Install Steps 1-17

Why Do I Need a Water Softener?

AC39 Manual Water Softener Operation and Recharging

Tel: Fax:

Clean Water Made Easy

Fully Automatic Water Softeners

Autotrol 255 Valve / 400 Series Controls

2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit

Technical Manual WATER SOFTENER. Models: PF-SOF1-SIM PF-SOF1-ALT PF-SOF1-PRL PF-SOF1,5-SIM PF-SOF1,5-ALT PF-SOF1,5-PRL PF-BTA

Autotrol Brand 255 Valve / 400 Series Controls

HD / HDL Valves & Systems Service Manual

WS1 Greensand Installation & Start Up Guide

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

TotalCare, CareSoft Elite CareSoft Pro. and. Series. Water Softeners and Conditioners. For Models: TC1 TC2 CSE CSERC CSP CSPRC

Installation Instructions and Owner s Manual. FSN Series. Nitrate Removal Water Softening System

Installation Instructions & Owner's Manual. IM & INT Series

FLECK XT OWNER S MANUAL

Autotrol Brand Performa Valve / 400 Series Controls

WATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

SIGNATURE SERIES. Signature Series Duplex Softener Manual. Installation / Operation Manual

OWNER S MANUAL & INSTALLATION GUIDE

Water Softener Installation / Operation Manual

User and Installer Handbook

Technical Manual WATER SOFTENER. Models: PF-SOF1-SIM PF-SOF1-ALT PF-SOF1-PRL PF-SOF1,5-SIM PF-SOF1,5-ALT PF-SOF1,5-PRL PF-BTA

165 Series Iron Filter Valve Manual

AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual

DUPLEX COMPACT. 11. CONNECTIONS (1/2",3/4, 1") BRINE VALVE 5. (floater)

This product was manufactured in an ISO 9001:2000 certified facility.

Commandomatic Ezysoft WATER SOFTENER SYSTEM

GROWMAX WATER Perfect Water for Plants and Gardens

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual

Transcription:

Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4. Installation Instructions p.5 5. Valve Initial Set-up p.6 6. End User Instructions p.8 7. Troubleshooting p.9 8. Cautions p.11 9. Technical Information p.12

1. Description & Equipment Adjustments Installation Number Nominal Capacity m 3 th Valve Serial Number Inlet Water Hardness th Tank Size Treated Water Volume litres Resin Type Outlet Water Hardness th Resin Volume litres Salt Quantity per Regeneration kg Regeneration Mode Volumetric m 3 Regeneration Type Down Flow Brining 1) Backwash min 2) Brining & Rinse min 3) Rapid Rinse min 4) Brine Tank Refill min Electrical Supply Low Voltage DC Transformer 2

2. Components, Features & Functions Component Features Functions Automatic Control Valve FDA approved Noryl plastic Strong corrosion resistance Innovative design 24 hours control and monitoring with a timer; automatically regenerates the media bed at the system s set time of regeneration according to the set regeneration frequency. Cycle Process: In service: Once the water is supplied with correct pressure and flow, the cations contained in hard water will be replaced by Na + in regenerants, then the softening system will supply softened water through its outlet. Backwash: When the ion exchange resin has been exhausted, the resin bed needs to be regenerated. Before the regeneration of the resin bed, a backwash step is necessary for two main purposes; removing the residue in the resin bed and loosening the impacted resin bed for better regeneration efficiency. Rinse: Rinse the resin bed to remove the residual regenerant (salt) after the brining step until the water from outlet contains no regenerant; rinse could also compact the resin bed for a better softening effect. Refill: Refill the brine tank with water to dissolve salt for the next regeneration. Valve Operation Mode Softener: Standard water softener operation Regeneration Mode Volumetric Water Hardness can be adjusted User can adjust the mixing valve to get desired water hardness Display Format Metric format Media High-grade Anion exchange resin (food grade 2 resin) Pressure Vessel NSF 44 tested and certified Polyethene material manufactured for the Food & Beverage industries Light, high pressure resistance Strong corrosion resistance Pressure vessel holds the resin and a distribution system Riser Tube & Distribution System A riser tube and distribution system disperse water evenly through the resin bed Brine Valve & Tank High pressure resistance Prevents the brine tank from overflowing Water and salt mix in the brine tank. Salt will dissolve continuously until the water is saturated by salts 3

3. Valve User Interface Bypass Regeneration Indicator Flow Rate Indicator Parameter Display Cycle Nº Time Display Next Button ( ) Regeneration Button ( R ) Up Button ( ) Down Button ( ) Blending Valve Drain Line Brine Line Outlet Inlet 4

4. Installation Instructions The softener needs to be installed on the mains water. It has an integrated bypass. Piping has to comply with the regulations of the country where it is installed. Do not plug in the electrical feed before the installation. Ensure the stopcock 5 is closed. The piping of the inlet and outlet are ¾ BSP. The water needs to have a pressure between 2-8 bar and 4-42 degrees. The softener has to be installed on a flat dry surface. Electrical mains powered 220-240V AC 50Hz for plug model. Water Pressure Electrical Supply Existing Plumbing Softener Location Bypass Valves 2-8 bar Uninterrupted AC Free of any deposits or build-ups inside pipes Locate close to drain & connect according to plumbing codes Always provide external bypass valve The soldering on the pipework has to be done before connecting the water softener as heating could damage the water softener. For residential purposes, it is essential to ensure that at least one drinking water tap is not connected to the softener. Softened water has a high Sodium content which is to be avoided for people on low sodium or salt diets, babies on infant formulas. 4.1. Connecting 1. Rotate the valve so that the electronic display faces the flip top lid on the softening system. (Fig.A) 2. Insert white brine tube inside the push fit valve connector. (Fig.B) 3. Close the stop cock. 5 4. Connect the drain Line to the the outside drain of the premises. It is necessary to fit an air gap device.the drain piping should be as short as possible avoiding height of over 1.5 metres higher than the softener as well as lengths of over 5 metres. 5. Connect the inlet and outlets to the fitted plumbing. 6. Close the bypass valves. 4 Open the stopcock 5 and open the water at the feed tap. This will allow any particles to be removed from the system before operation. Let water run out of the tap until it is clear. Once done, close both the outlet tap 6 and the stopcock 5 to pursue further steps of the installation. Fig. A Fig.B 7. Manually fill the brine tank with water between 5 and 10 cm. 8. Open the bypasses 4 as well as the stop cock. You will hear the water flowing into the resin pressure vessel. When there is no more water flowing in, open a cold water tap 6 so that the excess air will purge out of the system. Once the air is removed, close the tap. 6 9. You can now switch on the valve electrical power. 10. Press the R button for 5 seconds twice to allow a regeneration. It will last between 30 minutes and 1 hour. Mains Out 6 Power Supply 1 Bypass Valve Inlet Tee Incorporating Check Valve Pressure Reducing Valve (if required) 4 Internal Bypass Outlet Valve Inlet 2 3 Valve Main Water Tap For Drinking Drain Hose In Out To Drain Overflow To Outside 5 Mains Stopcock Water Softener Main Water Supply 5

5. Valve Initial Set-Up 5.1. Programming The capacity of your softener will depend on the hardness of your water. First of all, check Chart 1 to the right, depending on your softener model 13, 18 or 25 L The volume given in Chart 1 will be the volume of soft water produced between 2 regenerations in m 3. As an example, if you have a 18L softener with a hardness of 360ppm, your capacity will be 2.5m 3. This is the value you should set in the program. Chart 2: Regeneration Cycle Chart Cycle Settings Softener Model 13 18 25 Cycle 1 5 6 7 Cycle 2 21 25 30 Cycle 3 4 4 5 Cycle 4 4 6 8.5 5.2. Setting up the regeneration program 1. Push the DOWN / button until the time displayed is 23:45. 2. Push the NEXT / button for 8 seconds until r (VALUE) is displayed. 3. Push the UP / button until r-3 is displayed. 4. Press the NEXT / button until t-df is displayed. 5. Press the NEXT / button until F-(VALUE) is displayed. 6. Press the UP/ or DOWN / button until F-05 is displayed. 7. Press the NEXT / button until 1F-(VALUE) is displayed. 8. Press the UP / or DOWN / until reaching the value determined in chart 1. (i.e. an 18l softener with 200ppm = 4.5) 9. Press the NEXT / button until 1-(VALUE) is displayed. 10. Press the UP / or DOWN / button until you reach the value determined in the regeneration cycle setting chart for cycle 1 for your specific softener. 11. Press the NEXT / button until 2-(VALUE) is displayed. 12. Press UP / or DOWN / until you reach the valued etermined in the cycle setting chart for cycle 2 for your specific softener. 13. Press the NEXT / button until 3-(VALUE) is displayed. 14. Press the UP / or DOWN / button until you reach the value determined in the cycle setting chart for cycle 3 15. Press the NEXT / button until 4-(VALUE) is displayed 16. Press the UP / or DOWN / button until you reach the value determined in the cycle setting chart for cycle 4 17. Press the NEXT / button until the regeneration time is displayed (VALUE).H1 18. Using the UP / or DOWN / buttons set the time to a convenient one, when you are less likely to use water i.e. 3.H1 = 3AM 19. Press NEXT / button of:h2 will be displayed 20. Press NEXT / button of:h3 will be displayed 21. Press NEXT / button of:h4 will be displayed 22. Press the NEXT / button so that a time will be displayed. 23. Adjust to the correct rime of day using UP / or DOWN / then your softener is ready to work. Chart 1: Softener Water Capacity Chart Hardness Settings Hardnes Level in ppm CaCO 3 Resin Volume (L) 13 18 25 100 6.5 9.0 12.5 120 5.4 7.5 10.4 140 4.6 6.4 8.9 160 4.1 5.6 7.8 180 3.6 5.0 6.9 200 3.3 4.5 6.3 220 3.0 4.1 5.7 240 2.7 3.8 5.2 260 2.5 3.5 4.8 280 2.3 3.2 4.5 300 2.2 3.0 4.2 320 2.0 2.8 3.9 340 1.9 2.6 3.7 360 1.8 2.5 3.5 380 1.7 2.4 3.3 400 1.6 2.3 3.1 420 1.5 2.1 3.0 440 1.5 2.0 2.8 460 1.4 2.0 2.7 480 1.4 1.9 2.6 500 1.3 1.8 2.5 600 1.1 1.5 2.1 6

5. Valve Initial Set-Up 5.3. Operation in service mode Once your softener is running, you can view the time of day. By pressing NEXT / for a few seconds, you will be able to see the remaining capacity of soft water left. Once the capacity is expired, a flashing (CIRCLE) will be displayed on the screen, indicating a regeneration will be programmed at the time determined in the program. Regeneration will cause the machine motor to run, creating a mechanical noise, this is normal. 5.4. Adjust the Time of Day Push the UP / and DOWN / buttons to set the correct time. NB. The display of a valve using a low voltage transformer will blink during power failure. This blinking will end once the programming has been restored. 5.5. Displaying the Remaining Volume of Water to be Treated (Metered System Only) Push the NEXT / button to switch between the time of day and the remaining volume display. 5.6. Initiate a Regeneration Push the regeneration / R button for one second to initiate regeneration (the system will regenerate immediately for a valve in immediate regeneration mode or at the next pre-set time for a valve in delayed regeneration mode ). Push the REGENERATION / R button for 5 seconds to initiate regeneration immediately for a valve that is programmed in chronometric or volumetric mode. This is to be used to flush the system after a long time such as returning from holidays. 5.7. In Service The display will show the time of day during normal operation and will turn off after 3 minutes to conserve battery life for battery operated models. The remaining volume of water to be treated can be displayed by pushing the NEXT button. 7

6. End User Instructions Once the softener has been installed and setup by a professional, there are some useful functions to be aware of. Salt replenishment: when the softener runs out of salt, it will not produce any more soft water. It is therefore important to keep it topped-up, this is done via the lid of the top of the softener. Salt should always be visible over the line of water in the cabinet but the total volume of salt and water should not exceed the overflow level. NOTE: ONLY USE GRANULATED OR TABLET SALT DEDICATED TO WATER SOFTENERS Overflow Bypass: The Bypass is a function which makes the water softener offline. This is useful when soft water is not required (e.g. using a hosepipe) Lid In the service position, the softener will produce soft water. In the Bypass position, the water will not go through the resin tank and remain as hard water. Blending Valve: This can be used optionally when some applications require a certain level of hardness. When the blending valve is closed (Fully turned anticlockwise), you will get 100% soft water. The more you open it (turning clockwise), the harder the water will get. Display: In service, the valve will go in power saving mode and will not display information. Press regeneration / R button and the display will be active again, displaying the time of day. By pressing NEXT / you will display the amount of water left before the next regeneration is planned. If the symbol (Little circle with an arrow) is flashing, it indicates that your softener will regenerate at the programmed time. Regeneration is a standard process required to recharge the resin contained inside the softener. The regeneration will happen at the time set in the program. A motor noise can be heard when the softener is in regeneration mode, this is normal. 13 Litre Flo System. Service position shown. Moving the red lever upwards to a horizontal position will put the valve into the Bypass position. The screen will display the various cycles of the regeneration and will then go back to service mode. Backwashing Brining Rinse Refill Front view shows display/controls. Power Cuts: Your softener will keep its parameters in memory for up to 48 hours. After that, reprogramming may be necessary. Please refer to the programming sheet in the installer part of the manual. Downtime: After holidays, or a long period without using water over a week, it is recommended to initiate a manual regeneration in order to flush the resin tank. Press the regeneration / R button to bring up the display, press regeneration / R again for 5 seconds in order to program a delayed display (little circle flashing) and press a third time 5 seconds to start immediately. The cycle will finish after approximatively one hour. 8

7. Troubleshooting 7.1. FLO System Problem Possible Cause Possible Solution A. Controller does not work 1. Power off 2. Transformer is not plugged in 3. Defective power cord 4. Defective transformer 1. Switch on power 2. Connect to constant power source 3. Replace cord 4. Replace the transformer B. Incorrect time of regeneration 1. Power outage causes inaccurate timing 1. Reset the timer C. Leaking 1. Loose connections 1. Tighten joints D. Noisy 1. Air pressure in the system 1. Re-backwash the system to vent air E. Milk-white water 1. Air exists in the system 1. Turn on the tap to vent air F. Unsatisfied water hardness G. Softener fails to use salt 1. Poor raw water quality 2. Time of regeneration is too long 3. Resin disabled 1. Water pressure is too low 2. Brine line blocked 3. Injector is blocked 4. Internal control leak 1. Contact your supplier for assistance 2. Reset time of regeneration 3. Re-regeneration or use new resin 1. Line pressure must be at least 20 psi 2. Clean brine line 3. Clean or replace injector & screen 4. Check piston, seals and spacers H. Brine container overflow 1. Refill time too long 1. Contact your supplier for assistance I. Water hardness remains 1. Fail to regenerate automatically 2. Brine concentration is poor 3. Injector is plugged 1. Check power of controller 2. Keep brine tank full of salt 3. Disassemble the injector and clear it by washing with water K. Untreated water leakage during service 1. Improper regeneration 2. Leaking of bypass valve 3. O-ring around riser tube damaged 4. Incorrect regeneration cycle setting 1. Repeat regeneration making certain that the correct salt dosage is set 2. & 3. Replace O-ring 4. Reset regeneration cycle 9

7. Troubleshooting 7.2. FLO Valve Problem Possible Cause Possible Solution A. The system will not regenerate 1. Used or defective batteries 2. Disrupted electric supply 3. Damaged meter cable 4. Water meter turbine blocked 5. Defective drive motor 6. Defective electronic board 1. Replace old batteries 2. Recover the power supply 3. Verify the connection & inspect cable 4. Clean or replace the turbine 5. Replace the drive motor 6. Replace the electronic board B. There is hard water coming from the outlet 1. No salt in the brine tank 2. System in bypass position 3. Internal leak in valve 4. Dirty breech 5. Low brine tank refill 6. See symptoms in A 1. Refill the brine tank 2. Return the system to service position 3. Change the internal seals 4. Clean the breech 5. Change the two breech seals 6. See resolution in A C. Decrease in pressure and flow 1. Iron build up in the water supply 2. Iron build up in the system 3. Levels of iron too high in the feed water 1. Clean or replace the supply line to the system 2. Clean the valve and the resin bed. 3. Increase backwash time to prevent fouling. Specifically install an additional filter to remove iron. D. High levels of brine present in the brine tank 1. Clogged drain line 2. Defective cycle time 1. Check and clean the drain line 2. Adjust the cycle times E. The outlet water tastes salty 1. Clogged injectors 2. Clogged drain line 3. Clogged brine valve 4. Defective cycle time 5. Damaged drain flow control 1. Clean the injectors 2. Check the drain line and flow control 3. Clean or replace the piston assembly 4. Adjust the cycle time 5. Change the flow control F. There is a constant leak during normal operation 1. Defective seal 2. Defective piston 3. Control valve blocked in regeneration 4. Defective power head 1. Change the seals 2. Change the piston 3. Change the piston and the seals and spacers 4. Change the power head G. Valve regenerates continuously 1. Defective power head 1. Change the power head 10

8. Cautions 1. Without reading and understanding the contents of this user manual, DO NOT perform any operations on the control valve. 2. Strictly prohibit a leaning position when shipping, installing and using this product as this could cause damage. 3. During the regeneration, water from the tap will NOT be softened. It is NOT recommended to use water during regeneration; otherwise a negative effect on the regeneration result will occur. 4. Initiate a regeneration cycle when the softener has been inactive for a long period of time and then turn on the tap for several minutes before resuming normal use. 5. Do not disconnect power during service to prevent timer distribution. 6. If water usage or hardness of raw water dramatically increases (compared to the normal usage), then the frequency of regeneration should increase. 7. Hot water could cause severe damage to the softener system, for water boiler and water heaters users, ensure the total-run of the piping between the softener and the boiler is not less than 3 metres. It is recommended to install a check valve between the filter and the boiler if unable to meet the required piping length. 8. The input water pressure must be between 2-8 bar. 9. No chemicals should be present at the inlet and outlet connecting sectors. 10. Besides the system, spare part connection materials are not included in the scope of the manufacturer s warranty. 11. The required environmental temperature for a softener is 1-42 C. Outside these parameters may cause the softener to malfunction. 12. Do not apply pressure to the softener. 13. Indoor installation is preferred. Avoid exposure to direct sunlight, radiation from other heating sources and avoid extreme weather conditions including rain and snow. 14. Use salt granules or tablets designed for softeners. 15. No tools should be used for connecting the plastic parts as over tightening or excessive force could result in damage. 16. If necessary use food grade silica sealant for lubricating rubber O-rings. 17. Only qualified personnel should adjust or remove the adaptor locking clips on the reverse of the valve, as this can tamper with the valve settings. Should this be required pressure must firstly be discharged from inside the water softener. 11

9. Technical Information Maximum Operating Temperature (ºC) 42 Minimum Operating Temperature (ºC) 1 Maximum Operating Pressure (bar) 8 Minimum Operating Pressure (bar) 2 Hydrostatic Test Pressure (bar) 20 Max Flow Rate (m 3 /hr) 4.5 Inlet / Outlet (") ¾ Pressure Tank Thread (") 2.5 Valve SPECTRUM 5 Power Requirements (V) 230 Salt Storage (kg) 10 14 21 Resin Volume (l) 13 18 25 Nominal Flow Rate (m 3 /hr) 0.5 0.6 1 Salt Consumption Per Regeneration (kg) 1.5 2 3 Water Consumption Per Regeneration (l) 78 90 133 Cabinet Width (mm) 330 Cabinet Depth (mm) 470 Cabinet Height (mm) 660 870 1100 12