NEMA Manual. Starters. NEMA Manual Starters Contents

Similar documents
BULLETIN 600 SINGLE PHASE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

SECTION ENCLOSED CONTROLLERS

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Bulletin 609 Single And Three Phase

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Powers TM Controls ET 134 Line Voltage Room Thermostats

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

Modular Multi-position Air Handler

SECTION ROTARY-SCREW WATER CHILLERS

Powers Controls Low Temperature Detection Thermostat

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

MICRO SWITCH BAF/DTF Series

Description. Construction

Powers Controls ET 134 Low Temperature Detection Thermostat

CR1 Series Triton Corrosion Resistant Washdown Heaters

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

KUH. Horizontal Unit Heater. Applications. Description

Table of Contents. Protective Relays

Thermostat KPU. Data sheet

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Vibratone Horns. Models 350 and 450

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch..

PART GENERAL 1.01 SECTION INCLUDES

Electronic Control Pushbutton

EJB Custom-Built Control Panels

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

MaxGard. Interconnection Systems. Durability. Performance. Safety

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Instruction Manual Model A

FTA200-A REMOTE ALARM PANEL

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

a thriving company in a dynamic industry

Brasch Hazardous Location Unit Heaters

Two-Position Electric Duplex Room Thermostats

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Product Specifications 480 VAC, 70A Main Power Distribution Panel

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

INSTALLATION INSTRUCTIONS

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

HLA Series Hazardous Location Fan Forced Unit Heater

Copy Right By: Thomas T.S. Wan

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION EXTERIOR LIGHTING

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Thermostats and Accessories

ENERVEX RSV CHIMNEY FAN

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Comfort. Description. Applications

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

T4398A,B Precision Electric Heating Thermostat

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

A11 Series Low Temperature Cutout Controls

FDJ SERIES Jockey Pump Controllers Features

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Temperature, Mechanical

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

BEHIND THE PANEL AML s simple, cost effective design provides many behind-panel benefits for the designer and installer/user.

SECTION LOW VOLTAGE LIGHTING CONTROLS

CP CP

Tubular Industrial Process

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

HLA Series Hazardous Location Fan Forced Unit Heater

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Installation and Maintenance Manual Please retain this manual for future reference.

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Product Specifications 480 VAC, 175A Main Power Distribution Panel

INSTALLATION INSTRUCTIONS

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Sprecher + Schuh Motor Control and Protection Products

AIR TO AIR HEAT EXCHANGERS

Analog Room Pressure Monitor RPC Series

T P A 120 S 4 S N 1 Y

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Cooling/Heat Pump Convertible Air Handlers

FT60 Reduced Voltage - Autotransformer

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Construction Electrical

Transcription:

- February 007 NEMA Manual Starters Contents Page Types B0, B0, Switches.................................... - MS Series, Single-Phase Starters................................ -4 Type B00, Single- and Three-Phase Starters...................... -6 Type 944, Reversing Drum Switches............................ -0 CA08000E

- Types B0, B0, Switches February 007 Contents Product Features Manual Switches Page Product....... - Application.... - Features................ - Instructional Leaflet....... - Standards and Certifications........... - Wiring Diagrams......... - Dimensions............. - Product Selection........ - Manual Switches are available in two- or three-pole configurations rated at 0A. Optional NEMA aluminum enclosure is supplied with a padlock guard for locking in the OFF or STOP position. Application Manual Switches provide manual control of single- and three-phase motors where overload protection is not required or provided separately. Applications include: Fans Blowers Pumps Wood Working Equipment Machine Tools Compact size Easy installation Simple operation Padlockable NEMA enclosure available Instructional Leaflet Pub7 Standards and Certifications UL File No. E4664, Category NLRV CSA File No. LR7088, Class -0 Wiring Diagrams -Pole B0BN -Pole B0AN B0AN L L T T -Ph. B0BN L L T T T T -Ph. B0AN L L L T T T T T T -Ph. Dimensions Figure -. Wiring Diagrams.0 (.0). (8.). (8.4). (7.).06 (.).44 (6.6) 4.06.8 (0.) (8.). (60.).7 (7.7).78.8. (96.0) (60.) 4 #6- Tap.7 (69.9) #6- Tapped Holes for Wall Plate B0AN Ship. Wt. 4 oz. (. kg).0 (.) Dia. Mtg. Holes s B0BN and B0AN Ship. Wt. 6 oz. (.7 kg).0 (8.).0 (.) Holes. (.) Dia. 0.68 (7.) 4.7 (9.9).7.44 (69.9) (6.0).9 (.).4 (6.) Front View. (.7) Knockouts Holes.7 (6.9) Dia. Back View s B0AG, B0BG, B0AG Ship. Wt. 4 oz. (.40 kg) Figure -. Approximate Dimensions in Inches (mm) and Shipping Weights. (.7) x.7 (9.) Knockout Each End End View CA08000E

February 007 Types B0, B0, Switches - Product Selection When Ordering Specify of Manual Switch -Pole B0AN -Pole B0AN -Pole NEMA Enclosure B0BG Table -. Manual Switches without Overload Maximum Horsepower Ratings Open 0V 40V 480V 600V -Pole Manual Switches 0 -Pole Manual Switches B0AN B0BND NEMA Enclosed B0AG B0BGD 7-/ 0 B0AND B0AGD Discount Symbol...................... CD-C CA08000E

-4 MS Series, Single-Phase Starters February 007 Contents Manual Starters Page Product....... -4 Application.... -4 Features................ -4 Instructional Leaflet....... -4 Standards and Certifications........... -4 Accessories............. -4 Dimensions............. -4 Product Selection........ - Modular Toggle Operated Starter Product The MS Starter is a compact, versatile unit featuring heavy sliding contacts as well as quick-make and quick-break mechanism Dimensions Standard with large pressure type terminals, straight-through wiring and a trip-free handle mechanism The plug-in heater element is keyed to ensure proper positioning and an adjustable knob allows a setting of plus or minus ten percent of the nominal heater rating Application The MS Manual Starter provides manual control and overload protection to single-phase motors. By utilizing the interchangeable heater elements, the starter can protect motors ranging from.40 amps up to 6.0 amps. Ideal for HVAC applications. Features Compact size Trip-free handle mechanism Keyed heater elements to ensure proper installation Starters available with red pilot light The operating handle of the enclosed units can be locked in the OFF position Enclosures are offered in NEMA,, 4 and Hazardous locations cast aluminum enclosures are available rated for Type 7, Class I, Group D (vapors) and Type 9, Class II, Groups E, F an G (dust). Instructional Leaflet IL987G Standards and Certifications UL File No. E9, Category NLRV CSA File No. LR940-6, Class -0 Accessories Table -. MS Accessories Pilot Light Kit (NEMA Enclosure and Flush Plates) Box, Unit (NEMA Enclosure) Cover, Unit (NEMA Enclosure) Flush Plate, Unit (Steel) Flush Plate, Unit (Stainless Steel) Handle Guard (Padlockable for NEMA Enclosure and Flush Plates) MSPT MSBN MSCN MSFN MSDN MSLG.6 (9.) Dia..6 (4.).7 (69.).06 (.). (.8) Height of Handle.9 (4.8)..8 (7.9) (8.) 0 Typ..7 (9.).8 (96.8).8 (40.).9 (48.).7 (8.).70 (4.). (.8). (7.9). (.6).9 (0.).64 (4.7). (60.).4- Tap MS Starter Toggle Operated Open Units Figure -. Approximate Dimensions in Inches (mm). (.) 4. (4.).7 (69.9) Mounting Purposes () Holes.06 (6.9).8.66 (8.) (6.8).64 (4.7) Handle Guard. (.6). (7.). Indicating Light (7.9) Unit Flush Plates Unit. (60.).4.6 (0.4) (9.6) 4.6 (0.7). (4.0) Indicating Light Handle.06 Guard (77.7).0 (.) Diameter () Mounting Hole Type Enclosures (Boxes and Covers). (.6).64 (4.7).78 (9.8).4 (8.6). (.9).8 (8.).8 (7.9). (64.8).47 (6.7). (.6).97 (0).7 (9.) Pipe Tap.6 (9.).7 (9.).9 (7.9).7 (9.) Pipe Tap Watertight (Cast Aluminum).94 (00.).8 (0.6).0 (7.6) Dia. Lockout Hole. (88.9).6 (66.8).4 (8.6) Dia. () Mounting Holes Hazardous Location (Cast Aluminum).8 (47.6). (0.) 6.7 (70.7).88 (49.4).44 (.) Discount Symbol...................... CD-C CA08000E

February 007 MS Series, Single-Phase Starters - Product Selection When Ordering Specify of Manual Starter Heater Pack selection Any required Accessories Heater Coil selection according to the motor full load current requirements Table -. Product Selection MS Series Starters of Poles Open Type /4 /4 /4 Flush Plate (No Enclosure Included) Horsepower Voltage 0/40V, 77V AC 0/40V DC V DC 0/40V, 77V AC 0/40V DC V DC Flush Plate Type General Switch Only Switch with Pilot Light Purpose Switch Only Switch with Pilot Light Stainless Steel Switch Only Switch with Pilot Light Switch Only Switch with Pilot Light Enclosed Types Enclosure Type General Switch Only Switch with Pilot Light Purpose Switch Only Type Switch with Pilot Light MST0 MST0 MST0FN MST0FNP MST0FN MST0FNP MST0DN MST0DNP MST0DN MST0DNP MST0SN MST0SNP MST0SN MST0SNP Waterproof Through Hub MST0AH Type, 4 & Through Hub MST0AH Hazardous Location Through Hub MST0EH Types 7D, 9E, 9F & 9G Through Hub MST0EH Does not include heater. Select heater from Table -4. Type 7D = Type 7, Class I, Group D; Type 9E, 9F and 9G = Type 9, Class II, Groups E, F and G. Switch and Pilot Light Mounted on Flush Plate Switch and Pilot Light Mounted in Type Enclosure Waterproof Type, 4 & Typical Heater Table -4. Heater Selection for MS Starters Full Load Current Full Load Current Heater Element Installation Full Load Current Hazardous Location Type 7D, 9E, 9F & 9G Full Load Current.4.4.44.48.49..4.8.9.64.6.7.7.78.79.87.88.9.96.0 MSH-A MSH-A MSH-6A MSH-67A MSH-74A MSH-8A MSH-89A MSH-98A MSH-A MSH-A.04..6.7.8..6...67.68.8.84.99.00..4.47.48.7 MSH-A MSH-4A MSH-6A MSH-7A MSH-9A MSH-A MSH-A MSH-A MSH-8A MSH-A.7.9.96.7.8.9.60.99 4.00 4.9 4.40 4.79 4.80.6.7.8.84 6.9 6.40 7.0 MSH-4A MSH-7A MSH4-A MSH4-A MSH-0A MSH-A MSH6-0A MSH6-6A MSH7-A MSH8-0A 7.04 7.74 7.7 8.46 8.47 9. 9.6 0.0 0...6.47.48.67.68.. 6.00 MSH8-8A MSH9-7A MSH0-6A MSH-7A MSH-9A MSH4-A MSH-6A MSH7-A MSH8-6A Discount Symbol...................... CD-C CA08000E

-6 Type B00, Single- and Three-Phase Starters February 007 Contents Manual Starters Page Product....... -6 Application.... -6 Features................ -6 Instructional Leaflet....... -6 Standards and Certifications........... -6 Technical Data........... -6 Options................. -6 Accessories............. -6 Dimensions............. -7 Product Selection........ -8 Features Includes three-pole bimetallic overload relay Straight-through wiring Field mounted auxiliary contacts Available in NEMA, 4, 7, 9 and enclosures with toggle operation (NEMA enclosure for pushbutton operator) Standard with a lockout device to lock motor in the OFF position Technical Data Instructional Leaflet IL4890 Standards and Certifications UL File No. E9, Category NLRV CSA File No. LR940-6, Class -0 (Open Starters) CSA File No. LR47-, Class -0 (Closed Starters) Table -. Specifications NEMA Maximum hp for AC Ratings Maximum hp for DC Ratings Size 0V AC 08 40V AC 480 600V AC V DC 0V DC -Pole, Single-Phase M-0 M- -Pole, Three-Phase M-0 M- 7-/ 0 Ratings up to hp, -phase are suitable for group fusing. -/ -/ Options Accessories Pushbutton Operated Product The B00 Manual Starters can be used in single-phase applications rated hp at 40V AC or hp at 0V DC. The starter can also be rated for three-phase applications up to 0 hp at 600V AC. There are two methods of operation for the B00 Manual Starter. It can be ordered with a toggle switch operator or a START/STOP pushbutton operator. Table -6. Factory Modifications Suffix Adder Pushbutton operator A (open and NEMA only) Without lockoff X (open only) Add Suffix letter to starter Ex: B00MOCA. Table -7. Accessories Field Mounting Kits NO elect. auxiliary BA NC elect. auxiliary BB Red pilot light 0/60 LK- (NEMA Enc. Only) Red pilot light 08-40/6 LK- (NEMA Enc. Only) Red pilot light 480-600/60 LK-6 (NEMA Enc. Only) For Type 4 and Enclosures Only Red pilot light 0V Red pilot light 40V LK-4 LK-4 Application The B00 family of Manual Starters provides manual control, as well as overload protection, to both single-phase and three-phase motors. The starter protects motors up to.9 amp single-phase and 6.8 amp three-phase with the appropriate heater selection. Discount Symbol...................... CD-C CA08000E

February 007 Type B00, Single- and Three-Phase Starters -7 Dimensions 4.7 (9.9).6 (9.9).0 (6.7) 4.98 (6.).98 (0.).0 (.9).6 (6.0). (0.) (7) 7.9 (9.8) OFF.9 (.4) 9.9 (.4). (.6) Dia. 4 Mtg. Holes 6.0 (.4).6 (6.0). (8.6).9.6. (.4) (4.4) (.).0 / x /4 Conduit K.O. (76.) in Each Side.09 (.) 0.6 (8.) 8.8 (0.). (.8).0. (.9) (6.) Type Enclosed / x /4 Conduit K.O. in Bottom and in Top End /6- Mounting Screw.8 (4.).84 (48.).7 (4.) 6.0 (.4).0 (.).6 (6.0) Type 4 Enclosed 6.0 (.). (0.) 7. (8.).6 (90.4).9 (8.0) 4.9 (6.6) Open, Non-reversing Starter.6 (6.0). (0.) (7).7 (6.9).06 (06.) 0. (60.4) OFF ON 8. (.9) 4.9 (06.4) 9.9 (.4) 8.8 (0.) 9.4 (9.0) 4.06 (0.).4 (0.4) Slot Req'd. 8. (09.6). (.).0 (.4)-.0 NPSK Holes. (.) 6. (60.) 7.77 (97.4).97 (.6). (.7).88 (.4) 6.0 (.4) Type 7 & 9 Enclosed. (9.) 4.78 (.4) Type Enclosed Figure -4. Approximate Dimensions in Inches (mm) CA08000E

-8 Type B00, Single- and Three-Phase Starters February 007 Product Selection When Ordering Specify of Starter with application modifications Heater Pack selection A threephase starter requires three heaters, and a single-phase starter requires two heaters Any required Accessories Toggle Operated Type Enclosure Table -8. Product Selection Toggle and Pushbutton Operated Starters NEMA Size Open Type Toggle Handle Enclosed NEMA General Purpose Type B00 Non-reversing -Pole (For Single-Phase s and DC) M-0 M- B00M0B B00MB B00S0B B00SB Type B00 Non-reversing -Pole (For Polyphase s) M-0 M- B00M0C B00MC B00S0C B00SC NEMA 4 Watertight, Stainless Steel B00W0B B00WB B00W0C B00WC One -inch chrome hub supplied on each end. NEMA 7D = NEMA 7, Class I, Group D. NEMA 9E, 9F and 9G = NEMA 9, Class II, Groups E, F and G. Starter does not include heaters. Select s of heaters from Table -9. Tapped for -inch conduit on each end. NEMA 7D, 9E, 9F & 9G for Hazardous Locations B00U0B B00UB B00U0C B00UC NEMA Dust-Tight B00J0B B00JB B00J0C B00JC Discount Symbol...................... CD-C CA08000E

February 007 Type B00, Single- and Three-Phase Starters -9 Table -9. Heater Selection Full Load Current Max. Fuse Amps Single-Phase Enclosed Starters.8.9.0..4.6.7.40.4.4.46.0..6.7.6.64.70.7.78.79.86.87.9.96.04.0.4...6.9.40.4..7.7.89.90.0....4..79.80.07.08.6.7.68.69 4.0 4.04 4.40 4.4 4.8 4.8.6.7.74.7 6.6 6.7 6.8 6.84 7.4 7.46 8. 8. 8.8 8.8 9.8 9.9 0.40 0.4.0.40.0.0.0.60 4.90.00 6.00 6.0 7.0 7.0 8.0 8.40 9.70 9.80.0.0.80.90 4.0 4.60 6.40 6.0 8.0 8.60 0.80 0.90.0.40 6.00 6.0.90 4 4 6 7 8 8 9 0 0 0 0 0 0 0 0 40 4 0 0 60 60 70 70 80 88 90 90 00 0 FH0 FH04 FH0 FH06 FH07 FH08 FH09 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH FH9 FH40 FH4 FH4 FH4 FH44 FH4 FH46 FH47 FH48 FH49 FH0 FH FH FH FH4 FH FH6 FH7 Full Load Current Single-Phase Starters require two overload heaters. Three-Phase Starters require three overload heaters. Max. Fuse Amps Three-Phase Enclosed Starters..6.7.9.0....6.9.40.44.4.49.0..6.6.6.68.69.7.78.8.84.9.9.00.0.0.....6.0..66.67.84.8.0.04..4.4.46.69.70.9.96..4..4.8.86 4. 4. 4.6 4.6.0.04.49.0.99 6.00 6. 6.4 7. 7. 7.7 7.74 8.40 8.4 9. 9. 9.89 9.90 0.70 0.80.80.90.00.0 4.00 4.0.00.0 6.0 6.0 7.0 7.40 8.60 8.70 0.00 0.0.0.60.0.0.00.0 6.80 4 4 6 7 7 8 9 0 0 0 0 0 0 0 0 40 4 0 0 0 60 60 70 70 80 80 90 FH0 FH04 FH0 FH06 FH07 FH08 FH09 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH FH9 FH40 FH4 FH4 FH4 FH44 FH4 FH46 FH47 FH48 FH49 FH0 FH FH FH FH4 Note: FH Series heaters are for Type B00 manual motor starters. Heater element selection is based on motor nameplate s listed full load amperes. Trip rating of this series of elements is % of minimum motor full load amperes listed for the element. When motor and overload relay are in the same ambient and the service factor of the motor is. to., select heaters from the heater selection table. If the service factor is.0 or less (including zero), or a maximum of % protection is desired, select a heater one size smaller than indicated for the amperage range required. Discount Symbol...................... CD-C CA08000E

-0 Type 944, Reversing Drum Switches February 007 Contents Application Operation Reversing Drum Switches Page Application.... -0 Features................ -0 Operation............... -0 Standards and Certifications........... -0 Wiring Diagrams......... -0 Dimensions............. - Product Selection........ - Type DB and DD These drum switches are designed primarily for use with single-phase and squirrel cage, single-speed reversible motors which may be connected directly across-the-line. Typical applications would be hoists and machine tools. Features Compact size Front mounting easily installed Terminals front accessible slanted 4 for extra convenience Captive pressure clamps on terminal screws back off with screw no prying with screwdriver necessary Choice of operators Large Knob Orientation of operator independent of legend 60 positioning in -/ increments pointer remains oriented to legend Field convertible from maintained to momentary operation Replaceable, large volume, silver plated contacts Oiltight machine cavity or surface mounting types Modern attractive appearance All of the operators may be rotated 60 in -/ increments without losing the indication of the drum position. A red-lined pointer is permanently orientated to the legend markings and clearly indicates the selected drum function regardless of the selected setting for the operator. This enables the user to offset the operator to afford the most comfortable operating position. This is accomplished simply by loosening and retightening one screw. Standards and Certifications UL File No. E76, Category NLRV CSA Guide No. 84-N-.A, Class Wiring Diagrams L S L A S Single-Phase s Single-Phase s Polyphase s F DC s L F F S T T4 L T L T L T L A Shunt Field 4 A 4 T8 T8 4 T8 4 T4 T 4 L A 4 S S S 6 A L 6 T L 6 T L 6 T L 6 T L 6 S Series Field A A A T T4 T T T4 TTT Arm Arm T T8 T T8 T8 T F S For Shunt Split- Split- M Add Jumper Universal Phase Capacitor -Wire 4-Wire Capacitor-Start -Phase -Wire Series, Compound, Shunt Repulsion-Start Induction, Repulsion, Repulsion-Induction Figure -. Wiring Diagrams CA08000E

February 007 Type 944, Reversing Drum Switches - Dimensions Table -0. Approximate Dimensions and Shipping Weights Size Surface Mounting DB & DB DD & DD Cavity Mounting DB & DB DD & DD Type of Operator Knob Knob Knob Knob Dimensions in Inches (mm) Wide A.0 (6.).0 (6.). (8.9). (8.9) 4.00 (0.6) 4.00 (0.6) 4.0 (4.) 4.0 (4.) High B.88 (49.4). (6.7) 6.88 (74.8) 6. (8.8) 4.7 (0.7) 4.0 (4.).7 (46.). (0.) Deep C 4. (.).00 (76.) 4.7 (0.7).6 (9.).00 (7.0) 4.0 (4.). (.4) 4.6 (7.6) Mounting D.00 (0.8).00 (0.8).6 (66.8).6 (66.8).0 (88.9).0 (88.9) 4.00 (0.6) 4.00 (0.6) E. (7.). (7.).7 (69.9).7 (69.9) 4.00 (0.6) 4.00 (0.6) 4.0 (4.) 4.0 (4.) F.88 (47.8). (.).00 (0.8). (.).88 (47.8). (.).00 (0.8). (.) Shipping Weights Lbs. (kg).0 (.4).0 (.4) 4.0 (.8) 4.0 (.8).0 (.4).0 (.4) 4.0 (.8) 4.0 (.8) E F B E B.0 (88.9) Size DB and DB.88 (98.6) Size DD and DD D A C D A F C.00 (76.) Size DB and DB. (8.6) Size DD and DD Figure -6. Approximate Dimensions Surface Mounting Product Selection When Ordering Supply Figure -7. Approximate Dimensions Cavity Mounting Figure -8. Approximate Dimensions Panel Cutout Cavity Mount Type DB Flush Mount Standard Type DB and DD Surface Mounting Standard Type DB Flush Mount Knob Operator Type DB and DD Surface Mounting Knob Operator Table -. Reversing Drum Type without Overload Relay Maximum Horsepower Size Type of Operation -Phase Single- Phase DC Surface Mounting General Purpose NEMA Operator Flush or Cavity Mounting (Oiltight Mounting on Sizes DB and DD) These devices are field convertible from maintained both positions to momentary both positions. These devices are field convertible from maintained FORWARD and momentary REVERSE to momentary FORWARD and maintained REVERSE. Knob Operator 00 0V 0 7V V 0V V 0V -Pole -/ DB Maintained 944H68 944H69 944H74 944H7 Maintained and 944H7 944H7 944H76 944H77 Momentary -/ DB Maintained 944H 944H4 944H47 944H48 Maintained and 944H6 944H7 944H49 944H0 Momentary 7-/ -/ DD Maintained 944H84 944H8 944H8 944H87 7-/ 0 DD Maintained 944H6 944H6 944H6 944H64 Knob Discount Symbol...................... CD-C CA08000E

- February 007 CA08000E